NOYAFA NF-567 Temperature Time Controller User Manual
- June 11, 2024
- NOYAFA
Table of Contents
- NOYAFA NF-567 Temperature Time Controller
- Overview
- The working principle
- Product buttons description
- Operating Instructions
- Description of the temperature control function of thetemperature Time
- Time control of Temperature Time Controller
- Product packing list
- Parameters of Description
- Matters needing attention
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NOYAFA NF-567 Temperature Time Controller
Overview
NF-567 is antemperature Time Controller. This product uses microcomputer control technology and microprocessor as the core to realize intelligent control output of temperature and time. The operation is convenient and simple. Users can set and control the work and stop of other equipment according to their own use. It is suitable for temperature and time control of breeding room, farm, incubator, cold and hot ventilator, electric heating equipment, water pump, boiler, and various household appliances.
The working principle
The instrument automatically samples the environment temperature through the temperature sensor and detects it. When the environment temperature is the same as the starting temperature set by the temperature controller, the control circuit of the temperature controller starts When the ambient temperature and the temperature controller set the same stop temperature, the temperature controller control circuit to stop running.
Product buttons description
Operating Instructions
The temperature setting range of the temperature Time Controller
The temperature setting range of the temperature controller is -9°C to
99°C. The red digital tube in the middle displays the actual temperature
detected by the sensor in the current environment, and the left and right
digital tubes display the stop and start temperatures set by the user.
Stop /start temperature
After 2 seconds of power-on display, the red in the middle shows the actual
temperature sensed by the sensor, and the white on the left and right show the
stop temperature and start temperature set by the user respectively.
High temperature start (Refrigeration control)
When “stop temperature” < “start temperature”, the temperature controller
is in the “high temperature start” state as shown in the figure. At this time,
the green light is on, and the socket is powered. It is mainly used for
cooling, such as turning on the air conditioner, exhaust fan, etc.
Low temperature start (heating control)
When “stop temperature” > “start temperature”, the temperature controller
is in the “low temperature start” state as shown in the figure. At this time,
the red light is on, and the socket is powered off. Mainly used for heating.
Local calibration function
Press the SET key for more than 3 seconds to enter the calibration menu,
use the up and down keys to calibrate between -5 and 5 degrees, and select 0
without correction.
Description of the temperature control function of thetemperature Time
Controller
-
Refrigeration control
When “stop temperature” < “start temperature”, the temperature controller is in the “high temperature start” state. At this time, the green light is on and the socket is powered. It is mainly used for cooling, such as turning on the air conditioner, exhaust fan, etc. -
Heating control
When “stop temperature” > “start temperature”, the thermostat is in the “low temperature start” state as shown in the figure. At this time, the red light is on, the socket is powered off, and it is mainly used for heating. -
Alarm Function
When the actual temperature value is higher than 90°C, the red and green indicator lights will flash and alarm at the same time. -
Power off memory
If there is a power failure during operation, all the parameters last set by the temperature sensor will be automatically saved, and it will automatically run according to the settings before the power failure after the power supply is restored.
Time control of Temperature Time Controller
Temperature controller time control mode: use the internal clock signal of the MCU.
Intermittent time control function
Press the middle setting button to display F1 as an intermittent time
control function, the left side of F1 corresponds to the stop time, and the
right side corresponds to the start time to realize the cycle. Press the up
and down keys (1-99 minutes) to set. For example, if the left side of F1 is
set to 10 and the right side is set to 20, it means that the red indicator
light is on when the control is stopped for 10 minutes; the green indicator
light is on when the control is running for 20 minutes. So cycle.
Countdown time control function
Press the middle setting key, displaying F2 is the countdown time control
function: the setting time range is between 0001 and 9999 minutes.
Corresponding time on the left: 1~99 settings. Corresponding time on the
right: 1~99 settings. The left corresponds to the thousands and hundreds of
the timing time, and the right corresponds to the tens and ones of the timing
time.
For example, the left digital tube display is set to 06, and the right
digital tube display is set to 00, then the timing time is 600 minutes (10
hours). After 10 hours, the temperature controller stops, the green indicator
light is off, and the red indicator light is on. charging etc.
Appointment time control function
Press the middle setting key, displaying F3 is the reservation time control
function: the setting range is between 0001-9999 minutes. The left and right
correspond to the time setting of 1-99. The left side corresponds to thousands
and hundreds of times of the timing time, and the right side corresponds to
the tens and ones of the timing time. For example, if the left side is set to
00 and the right side is set to 20, it means that after 20 minutes, the green
indicator light of the temperature controller will be on, and the temperature
controller is in the running state, which is suitable for scheduled start-up.
Product packing list
Name | Quantity |
---|---|
Temperature Time Controller | 1PCS |
Manual | 1PCS |
Certificate | 1PCS |
Parameters of Description
Product Name | Temperature Time Controller |
---|---|
Product Model | NF-567 |
Temperature Sensing probe | NTC10K-100cm |
Power Supply Voltage | 160-250V AC 50/60Hz |
Temperature Control Range | -9〜99℃ |
Max Power | 2200W |
Max Current | 10A |
Temperature control accuracy | ±1℃ |
Temperature sensing element | NTC |
Alarm Function | When the actual temperature is higher than 90°C, the traffic |
light flashing alarm.
Power off memory function| Yes
Calibration function| Yes
Temperature control function| Refrigeration control| Hot start
Heating Control| Cold start
Time control function| Intermittent time control function| Yes
Countdown function| Yes
Function when making an appointment| Yes
Working environment temperature| -10〜60℃
Working relative temperature| 20〜90%
Protection Level| IP20
Appearance size| 145X78X40 mm
Matters needing attention
- Make sure that the host and electrical appliances are installed out of the reach of children.
- When overhauling the electrical appliances, the output socket must be disconnected first, otherwise, the electrical appliances start at any time will cause personal injury.
- Electrical equipment needs to be tested regularly to ensure normal operation, and stop using it immediately before troubleshooting.
- For places involving temperature monitoring of important properties, multiple protection schemes should be adopted.
- Electrical appliances exceeding the load power must use an AC receiver and be installed by a professional electrician.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>