OptConnect mylo dura Fully Managed Wireless User Guide

June 11, 2024
OptConnect

OptConnect mylo dura Fully Managed Wireless

Welcome to mylo dura
mylo dura is a compact 4G/5G Category M1 multi-carrier cellular router perfectly suited for industrial applications that require slower speed connectivity and the peace of mind of redundant carrier connections.mylo dura’s small size allows it to fit almost anywhere.
Every mylo dura comes with OptConnect managed wireless services and a lifetime license to Summit – the management system designed for your phone, tablet, or computer.
mylo dura also includes Glimpse™, and on board API that responds to requests from your equipment’s software and tells your equipment how the cellular connection is performing. Only OptConnect has Glimpse™.

Follow steps 1 through 11 for a successful installation.

Simple steps to Place, Plug & Play

  1. Identify mylo dura and its included accessories
  2. Position the antenna and place mylo dura
  3. Connect AC/DC power converter
  4. Maximize signal strength and quality
  5. Configure your equipment for DHCP
  6. Configure your equipment for Static IP
  7. Connect ethernet cable and test
  8. Identify remote access IP address
  9. Identify remote access port
  10. Use the OptConnect Private Network for remote access
  11. Manage your OptConnect Device
Identify mylo dura and its accessories

IMPORTANT

  • Use only the included AC 18-24V, DC 8-40V power supply to maintain warranty coverage.
  • The identifiers on the bottom of mylo are important.
  • Your equipment’s IP settings are critical. See the steps on the next pages.
Position the antenna, and place mylo dura
  • Avoid placing the antenna inside equipment constructed entirely or mostly of metal
  • Position the antenna on a metal surface 3-5 inches from any edge – location on a metal surface can improve signal strength
  • Orient the antenna
    1. Point vertically upward (best)
    2. Point vertically downward, routing antenna cable away from antenna shaft (next best)
    3. Point horizontally (least preferred)
  • Place mylo dura in your equipment with included DIN rail bracket or adhesive
  • When attaching the mounting plate, leave device serial numbers facing outward for easy access
  • Route antenna lead to mylo dura
  • Connect the antenna lead to mylo dura and fully tighten

This part can be used to convert and regulate AC and DC voltages down to 5VDC as required by OptConnect Routers. The two red wires with exposed contacts should be connected to the source power supply. For AC installations, the polarity of the wires does not matter. For DC installations, the polarity is marked on the bottom right of the enclosure.

Connect AC/DC power converter

This part can be used to convert and regulate AC and DC voltages down to 5VDC as required by OptConnect Routers. The two red wires with exposed contacts should be connected to the source power supply. For AC installations, the polarity of the wires does not matter. For DC installations, the polarity is marked on the bottom right of the enclosure.

  • Connect power cord to mylo dura – ensure the green LED next to the power port glows
  • After 10-60 seconds, ensure the middle green LED glows or flashes

IMPORTANT – when mylo dura powers on the first time it may download a software update. This is indicated by a rapidly flashing middle green LED light for 1-2 minutes followed by the LED going dark while mylo dura reboots. You must allow this process to complete.

Maximize signal strength and quality

mylo dura may work well at this point. However, this step is strongly recommended to avoid potential future issues.

  1. Log in to the OptConnect Summit portal at
  2. Click Total Devices link
  3. Locate serial number on mylo dura and scroll to find it or type it in Search/Filter box and press Enter
  4. Click mylo dura’s link to view Signal Strength in On Demand Info section
  5. Adjust antenna position by an inch or two
  6. Click Refresh on Demand Info button – Important: mylo dura can take 15 seconds to update
  7. Repeat steps 5-6 until signal strength is maximized and signal quality is maximize
  8. If it is not possible to maximize both signal strength and quality, maximize quality
  9. Recommended: enter your device’s identified and description

Configure your equipment for DHCP
If you wish to initiate a remote connection to your equipment from your host, do not use DHCP. Got to Step 6 to set up a Static IP.

  • Set your equipment to obtain an IP address through DHCP

Optionally Configure your equipment for Static IP
Skip to step 7 if you do not need to initiate a connection from your host to your equipment through mylo dura

  • Set your equipment as follows:
    • IP address
    • Subnet mask
    • Gateway
    • DNS server 1
    • DNS server 2
    • 192.168.1.11
    • 255.255.255.0
    • 192.168.1.90
    • 192.168.1.90
    • 8.8.8.8
  • If you have a second piece of equipment to which you need to initiate a connection from your host, configure it as above with an IP address of 192.168.1.12

Connect ethernet cable and test

  • Connect the ethernet cable to your equipment and to mylo dura – ensure the amber LED next to the ethernet port glows or flashes
  • Restart your equipment or cause it to refresh its network environment
  • Perform a test with your equipment
  • If the test fails
    • Restart your equipment
    • Confirm your equipment’s IP configuration (see Step 5 or Step 6)
    • If your equipment is using a DHCP IP address, confirm it has been issued one by mylo dura, ex. 192.168.1.115
    • Repeat test
    • Contact our OptConnect Customer Care Center at 877.678.3343 x3

Identify remote access IP address
Skip to step 11 if you do not need to initiate a connection from your host to your equipment through mylo dura

  • Look up the IP address of your mylo dura in Summit or contact our Customer Care Center at 877.678.3343
  • Ensure your equipment is configured for a static IP address (see Step 6)

Identify remote access ports numbers
Skip to Step 11 if you do not need to initiate a connection from your host to your equipment through mylo dura.

  • mylo dura is configured for common remote access protocols such as https, RDP, vnc, ssh, GoToMyPC, etc. for two clients
  • Learn your preferred protocol’s TCP/IP port number from a manual or published resources, ex. https is port 443
  • Prepend a digit to the protocol’s port number to reach your equipment according to the table below where xxx is the port number on which your equipment will respond:
    • To reach your equip on port xxx    Contact port
    • 192.168.1.11………………………………  xxx
    • 192.168.1.12……………………………… 2xxx
  • Ex: directing your browser to : 2443 establishes an https session on port 443 with your equipment at IP address 192.168.1.12, the 2nd device in the table above
  • mylo dura is pre-configured for remote access to two static IP clients as per the table above. Contact our Customer Care Center at 877.678.3343 for custom configurations.

Use the OptConnect Private Network for remote access
Skip to Step 11 if you do not need to initiate a connection from your host to your equipment through mylo dura.
OptConnect cellular products, including mylo dura, operate on a private network to protect them an your equipment from attempted malicious access originating from the Internet.

Your computer, host system, or company’s office network must use VPN credentials to be granted access to our private network and to remotely access your equipment.
If this mylo dura is your first OptConnect device, contact our Customer Care Center at 877.678.3343 to install our free software VPN client or to discuss other options.
If this mylo dura is part of a larger portfolio of OptConnect devices, your company is already using credentials to remotely access your equipment. You do not need to take any additional steps for remote access.

Manage your OptConnect Device
mylo dura includes a lifetime license to Summit to help you manage your cellular devices.
Log in at summit.optconnect.com or contact our Customer Care Center at 877.678.3343.

FAQ

How do I log in to mylo dura?
There is no log in for mylo dura. OptConnect manages all aspects of mylo dura as part of our Managed Wireless Services.

How do I change mylo dura’s IP address, firewall settings, etc.?
Each mylo dura you receive is configured to your specifications before it arrives. mylo dura does not need to be configured on site unless your equipment/application requirements have changed. Contact our Customer Care Center at 877.678.3343 to adjust mylo dura’s configuration.

How do I know if mylo dura is online?
The middle green LED will flash or glow steadily when mylo dura is communicating with the cellular network. For more detailed performance and historical information see Summit at summit.optconnect.com or add Glimpse™ support to your equipment’s software.

How do I get support?
Contact our Customer Care Center at 877.678.3343

Let us show you why thousands of customers have made OptConnect the leading IoT managed services provider for headache-free cellular connectivity with award-winning products and top-rated customer service.
OptConnect.com
877.678.3343

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

OptConnect User Manuals

Related Manuals