QUBINO Luxy Smart Switch ZMNKAD1 Manual
- June 8, 2024
- QUBINO
Table of Contents
- QUBINO
- Luxy Smart Switch
- SKU: ZMNKAD1
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Parameter no. 1Relay contact type
- Parameter 10: Parameter no. 10.auto on timer
- Parameter 11: Parameter no. 11.auto off timer
- Parameter 12: Parameter no. 12.auto on timer relay
- Parameter 13: Parameter no. 13.auto off timer relay
- Parameter 3: Parameter no 3.turning off alarming
- Parameter 30: Parameter no. 30.restore state on power failure
- Parameter 31: Parameter no. 31.restore relay state on power failure
- Parameter 40: Parameter no. 40Watt Power Consumption Reporting Threshold
- Parameter 42: Parameter no. 42Watt Power Consumption Reporting Time
- Parameter 60: Parameter no. 60Lock touch for relay only
- Parameter 70: Parameter no. 70 – Overload safety switch
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
QUBINO
Luxy Smart Switch
SKU: ZMNKAD1
Quickstart
This is a
secure
Color Switch
for
.
To run this device please connect it to your mains power supply.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Luxy Smart Switch is an innovative light source that gently illuminates in more than 16 million colors and easily fits into places of your light switch or socket. It can be used standalone, as ambient light, or as a smart home device. With an additional output, it can simply replace your existing light switch or can be used for powering IR panels, fans, water heaters, etc.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 1| Supports following commands:COMMAND_CLASS_DEVICE_RESET_LOCALLY,
DEVICE_RESET_LOCALLY_NOTIFICATION – triggered upon reset,
COMMAND_CLASS_SWITCH_MULTILEVEL_V4, SWITCH_MULTILEVEL_REPORT_V4 – triggered
upon change of brightness, COMMAND_CLASS_SWITCH_COLOR_V3,
SWITCH_COLOR_REPORT_V3 – triggered upon change of color,
COMMAND_CLASS_NOTIFICATION_V8, NOTIFICATION_REPORT_V8 – triggered upon change
of alarm detection state or upon current overload detection,
COMMAND_CLASS_SWITCH_BINARY, SWITCH_BINARY_REPORT – is triggered when a change
of output state of relay occurs. COMMAND_CLASS_METER, METER_REPORT – triggered
upon energy consumption change according to configuration parameters 40 and
42.CONFIGURATION_REPORTtriggered upon a local change of the working mode of
the four capacitive buttons (see chapter 5.4)Reserved for communication with
the primarygateway/hub. Used to report unsolicited messages to the controller.
---|---|---
2| 5| Supports the following command:COMMAND_CLASS_BASIC_V2, BASIC_SET_V2 – is
triggered when a change of output state occurs; LEDs are on/off.
3| 5| Supports the following command:COMMAND_CLASS_SWITCH_MULTILEVEL_V4,
SWITCH_MULTILEVEL_SET_V4 – is triggered when a change of output state occurs;
brightness changes.
4| 5| Supports the following command:COMMAND_CLASS_SWITCH_COLOR_V3,
SWITCH_COLOR_SET_V3 – is triggered when a change of output state occurs;
colour changes.
5| 5| Supports the following command:COMMAND_CLASS_BASIC_V2, BASIC_SET_V2 – is
triggered when a change of output state of relay occurs.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Parameter no. 1Relay contact type
Defines the contact type when open/closed contact.Values (size is 1-byte
dec): Default value 0 0 – NO (normally open) output type 1 – NC (normally
close) output type
Size: 1 Byte, Default Value: 0
SettingDescription
0 | NO (normally open) output type |
---|---|
1 | NC (normally close) output type |
Parameter 10: Parameter no. 10.auto on timer
Defines the time after which the device is turned to last known state.Values
(size is 1-byte dec): Default value 0 0disabled 3032535 = 3032535 seconds
after which the device turns on
Size: 2 Byte, Default Value: 0
SettingDescription
0 | disabled |
---|---|
30 – 32525 | 3032535 seconds after which the device turns on |
Parameter 11: Parameter no. 11.auto off timer
Values (size is 2-byte dec):Defines the time after which the device is
turned to last known state. Default value 0 0disabled 3032535 = 3032535
seconds after which the device turns off
Size: 2 Byte, Default Value: 30
SettingDescription
0 | disabled |
---|---|
30 – 32525 | 3032535 seconds after which the device turns off |
Parameter 12: Parameter no. 12.auto on timer relay
Defines the time after which the device’s relay is turned to last known
state.Values (size is 2-byte dec): Default value 0 0disabled 3032535 = 3032535
seconds after which the device turns on
Size: 2 Byte, Default Value: 30
SettingDescription
0 | disabled |
---|---|
30 – 32525 | 3032535 seconds after which the device turns on |
Parameter 13: Parameter no. 13.auto off timer relay
Defines the time after which the device’s relay is turned to last known
state.Values (size is 2-byte dec): Default value 0 0disabled 3032535 = 3032535
seconds after which the device turns off
Size: 2 Byte, Default Value: 30
SettingDescription
0 | disabled |
---|---|
30 – 32525 | 3032535 seconds after which the device turns off |
Parameter 3: Parameter no 3.turning off alarming
Values (size is 1-byte dec): Default value 1 0only by z-wave command (basic
set, switch multilevel set, switch multilevel start/stoplevel change, switch
color set, switch color start/stop level change, notification reportidle)
1capacitive input (up, down, left, right) or z-wave command (basic set,
switchmultilevel set, switch multilevel start/stop level change, , switch
color set, switch color start/stop level change, notification report idle)
Size: 1 Byte, Default Value: 1
SettingDescription
0| only by z-wave command (basic set, switch multilevel set, switch multilevel
start/stop level change, switch color set, switch color start/stop level
change, notification report idle)
---|---
1| capacitive input (up, down, left, right) or z-wave command (basic set,
switch multilevel set, switch multilevel start/stop level change, , switch
color set, switch color start/stop level change, notification report idle)
Parameter 30: Parameter no. 30.restore state on power failure
Values (size is 1-byte dec): Default value 1 1enabled (the device will
restore state on power failure) 0disabled (the device will not restore state
on power failure and will remain off)
Size: 1 Byte, Default Value: 1
SettingDescription
1 | enabled (the device will restore state on power failure) |
---|---|
0 | disabled (the device will not restore state on power failure and will |
remain off)
Parameter 31: Parameter no. 31.restore relay state on power failure
Values (size is 1-byte dec): Default value 1 1enabled (the device will
restore state on power failure) 0disabled (the device will not restore state
on power failure and will remain off)
Size: 1 Byte, Default Value: 1
SettingDescription
1 | enabled (the device will restore state on power failure) |
---|---|
0 | disabled (the device will not restore state on power failure and will |
remain off)
Parameter 40: Parameter no. 40Watt Power Consumption Reporting Threshold
for Load
Choose by how much power consumption needs to increase or decrease to be
reported. Valuescorrespond to percentages so if 10 is set (by default), the
device will report any powerconsumption changes of 10 % or more compared to
the last reading.Values (size is 2-byte dec): Default value 10 0 – Power
consumption reporting disabled 1 – 100 = 1 % – 100 % Power consumption
reporting enabled. New value is reported onlywhen Wattage in real time changes
by more than the percentage value set in thisparameter compared to the
previous Wattage reading, starting at 1 % (the lowest valuepossible).NOTE:
Power consumption needs to increase or decrease by at least 1 Watt to be
reported,REGARDLESS of percentage set in this parameter.
Size: 2 Byte, Default Value: 10
SettingDescription
0 | Power consumption reporting disabled |
---|---|
1 – 100 | = 1 % – 100 % Power consumption reporting enabled. New value is |
reported only when Wattage in real time changes by more than the percentage value set in this parameter compared to the previous Wattage reading, starting at 1 % (the lowest value possible). NOTE: Power consumption needs to increase or decrease by at least 1 Watt to be reported, REGARDLESS of percentage set in this parameter.
Parameter 42: Parameter no. 42Watt Power Consumption Reporting Time
Threshold for Load
Set value refers to the time interval with which power consumption in Watts
is reported (0 32535 seconds). If 300 is entered (by default), energy
consumption reports will be sent to thegateway (hub) every 300 seconds (or 5
minutes).Values (size is 2-byte dec): Default value 0 0 – Power consumption
reporting disabled 30 – 32535 = 30 – 32535 seconds. Power consumption
reporting enabled. Report is sentaccording to time interval (value) set here.
Size: 2 Byte, Default Value: 0
SettingDescription
0 | Power consumption reporting disabled |
---|---|
30 – 32525 | 30 – 32535 seconds. Power consumption reporting enabled. Report is |
sent according to time interval (value) set here
Parameter 60: Parameter no. 60Lock touch for relay only
This parameter enables ONLY the touch functionality for closing/opening the
relay meant forswitching ON/OFF the connected light or any other connected
load. See chapter 5.4 foradditional information.Values (size is 1-byte dec):
Default value 0 0disabled 1enabled (the user can switch ON/OFF the connected
light or any other connectedload by touching ANY button. Other functionalities
(lighting mode, scenes, dimming andfull white, inclusion/exclusion and reset)
are unavailable until function disabled).
Size: 1 Byte, Default Value: 0
SettingDescription
0 | disabled |
---|---|
1 | enabled (the user can switch ON/OFF the connected light or any other |
connected load by touching ANY button. Other functionalities (lighting mode, scenes, dimming and full white, inclusion/exclusion and reset) are unavailable until function disabled).
Parameter 70: Parameter no. 70 – Overload safety switch
_The function allows for turning off the controlled device in case of
exceeding the defined powerfor more than 5 sec. Controlled device can be
turned back on by capacitive antenna/s or sendinga control frame.Values (size
is 2-byte dec): Default value 2300 0 = function not active 12300 = 1 W2300 W
NOTE: This functionality is not an overload safety protection, please check
chapterFunctionalities for more details.In case of overload the following
message will be send towards the controller:COMMAND_CLASS_NOTIFICATIONV5The
Alarm V1 type field set to 0x00Notification Type 0x08 and 0x08 (Overload
detected)
Size: 2 Byte, Default Value: 1
SettingDescription
0 | function not active |
---|---|
1 – 2300 | 1 W2300 W |
Technical Data
Hardware Platform | ZM5101 |
---|---|
Device Type | Color Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 20.00:20.00 |
Z-Wave Version | 6.82.01 |
Certification ID | ZC10-21017006 |
Z-Wave Product Id | 0x0159.0x0008.0x0052 |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info V3
- Association V2
- Basic V2
- Configuration
- Device Reset Locally
- Manufacturer Specific V2
- Meter V4
- Multi Channel Association V3
- Multi Channel V4
- Notification V8
- Powerlevel
- Security 2
- Supervision
- Switch Binary
- Switch Color V3
- Switch Multilevel V4
- Transport Service V2
- Version V2
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>