Product Information

The product is a lighting system with the model number 2022/04-1 A3+ / 329x483mm. The brand of the product is Kanlux and the website for the brand is www.kanlux.com. The lighting system has the following features:

  • The product has FLINI IP44 certification.

  • The product comes with P1, P2, P3, P4, P7, HLDR-GX5.3, and
    BR-GZ10.

  • The lighting system operates at 12V and has a maximum power of
    10W MR16 LED Gx5,3.

  • The system also supports max 10W PAR16 LED GU10/GZ10.

  • The product is IP44 and IP20 rated.

Product Usage Instructions

Follow the below instructions to use the product:

  1. Ensure that the product is installed in a suitable location with appropriate wiring and fittings.
  2. Check that the voltage of the power supply matches the voltage range supported by the product (220-240V~).
  3. Choose the appropriate P1, P2, P3, P4, P7, HLDR-GX5.3 or BR-GZ10 as per your requirement.
  4. Insert max 10W MR16 LED Gx5,3 or max 10W PAR16 LED GU10/GZ10 in the lighting system.
  5. Make sure that the product is connected to a SELV power source of 12V.
  6. Ensure that the product is switched off before installation, maintenance or replacement of the light source.
  7. Do not use the product near water or in damp conditions unless the product has an IP44 rating.
  8. Do not use the product if it has any visible damage or defects.

INTENDED USE / APPLICATION
Decorative ring – component of the lighting fixture. Product designed to be used in the home and for other similar general applications.

MOUNTING
Technical changes reserved. Read the manual before mounting. Mounting should be performed by an appropriately qualified person. Any activities to be done with disconnected power supply. Mounting diagram: see pictures. Kanlux FLINI
IP44 Ring For Spotlight Fittings 5 Kanlux FLINI IP44 Ring For Spotlight Fittings 6 Kanlux FLINI IP44 Ring For Spotlight Fittings 7 Kanlux FLINI IP44 Ring For Spotlight Fittings 8 Kanlux FLINI IP44 Ring For Spotlight Fittings 9 Kanlux FLINI IP44 Ring For Spotlight Fittings 10 Kanlux FLINI IP44 Ring For Spotlight Fittings 11 Kanlux FLINI IP44 Ring For Spotlight Fittings 12 Kanlux FLINI IP44 Ring For Spotlight Fittings 13

Check for proper mechanical fastening and connection to electrical power prior to first use. Terminals need to be placed in a way that will disable their contact with the product parts that become heated. A single component is not a complete lighting fixture. Use only the listed types of frames, as per the drawing. The components used must be compliant with the applicable technical requirements in terms of safety. The type of components used must be selected to match the mains voltage and the expected operating conditions.

FUNCTIONAL CHARACTERISTICS
Product for indoor use.

USAGE GUIDELINES / MAINTENANCE

Any maintenance work must be done when the product is disconnected from power supply. Clean only with soft and dry cloths. Do not use chemical detergents. Ensure free air access. Product can only be supplied by rated voltage or voltage within the range provided. Light sources with parameters provided in the manual must be used in the product. The light source becomes heated to a high temperature. Product may heat up to a higher temperature. Do not cover the product. Place all the leads and elements mating with the fixture ensuring no contact with the parts of the lighting system that become heated. Adjustment of lighting direction and/or replacement of the light source must be done when the product has cooled down. Replacement of light source to be performed after the product cools down: see pictures. Product must not be used in unfavourable environment, e.g. dust, moisture,water, vibrations, etc. The inspection of all connections and
elements of the lighting system is recommended.

EXPLANATIONS OF SYMBOLS USED

Kanlux FLINI IP44 Ring For Spotlight Fittings 1 Kanlux FLINI IP44 Ring For Spotlight Fittings 2

Kanlux FLINI IP44 Ring For Spotlight Fittings 3

P1 : Rated voltage.
P2 : Maximum power of the light source.
P3 : LED lamp.
P4 : Base/holder.
P5 : Product meets the requirements of EU directives.
P6 : The product not suitable for covering with heat-insulating material.
P7 : Class III A product in which protection against electric shock is provided by feeding it with very low safe voltage (SELV) with no risk of creating higher than safe voltage.
P8 : Use only indoors.
P9 : Protection against solid foreign objects bigger than 1,0mm provided. Protection against splashing water provided.
P10 : Protection against solid foreign objects bigger than 12mm provided.
P11 : Class II. A product in which protection against electric shock is provided not only through basic insulation, but also double or reinforced insulation.
P12 : The symbol describes the minimal distance of a light fixture (its light source) from the spots and objects that it’s illuminating.
P13 : The chipped globe, screen or protective shield must be replaced immediately. Immediately stop using the product if the outer bulb is cracked or broken. The product can only be used in a lighting fixture with protective glass.
P14 : The product is compliant with all relevant United Kingdom regulations.
P15 : The product meets the requirements of technical regulations applicable in Ukraine.

ENVIRONMENTAL PROTECTION
Keep your environment clean. Segregation of post-packaging waste is recommended.

COMMENTS / GUIDELINES
Failure to follow these instructions may result in e.g. fire, burns, electrical shock, physical injury and other material and non-material damage. For more information about Kanlux products visit www.kanlux.com. Kanlux S.A. shall not be responsible for any damage resulting from the failure to follow these instructions. Kanlux SA reserves the right to make changes in the manual – the current version can be downloaded at www.kanlux.com.