INSTILLATION INSTRUCTION

MODEL| ROTOR| VANE KIT| RING| INLET PLATE| COVER END CAR KIT| COVER END F3 CART KIT
---|---|---|---|---|---|---
3520V*2| 402690| 02-136720| 388683| 584383| 02-102506| 02-102512
3520V*5| 333624| 02-102515| 02-102513
333625| 02-102508| 02-102514
3520V
11| 403539| 02-136721| 3333626| 584384| 02-102509| 02-102515
3520V12| 353901| 02-102510| 02-102516
3520
14| 353902| 02-102511| 02-102517

Product Overview

• Included in shaft end cartridge kit
■  Included in cover end cartridge kit
Included in seal kit 922859 F3 equivalent seal kit 919304
Included in foot bracket kit FB—C-10 Assemble seal with spring loaded sealing member towards bearing. Seals to be completely wetted with oil prior to assembly.
Install 419674 sealing ring into body, then install cartridge kit.

MODEL RING SHAFT END KIT SHAFT END F3 CART KIT
3520V25 576210 02-102552 02-102560
3520V30 576212 02-102553 02-102561
3520V35 576214 02-102554 02-102562
3520V38 575476 02-102555 02-102563

Product Overview

MODEL COVER HOUSING BODY S/A
35020V**A 250824
252504 250818 942355
3520V**E 942355
3520VM**A 478510 478506 02-136921
3520VM**AM 02-136922
SHAFT TYPE KEY
--- --- ---
258249 (1) Keyed 88678
258250 (11)splined
394517 (86) keyed 393536
860097 (192N) Keyed 472287

Product Overview

NOTE:
For satisfactory service life of these components in industrial applications, use full flow filtration to provide fluid which meets ISO cleanliness code 16/13 or cleaner. OFP, OFR, and OFRS series filters are recommended.

Model Code

Symbols

  1. Special Seals

  2. Series designation
    Displacements cm³ (in³/r)
    Model Shaft end  Cover end
    3520V 81 — 121 18 — 45
    (4.94-7.37)   (1.1 — 2.22)

  3. Pilot designation
    M — Metric per ISO 3019/2 100A2HW Om It — Standard pilot

  4. Geometric displacement
    Shaft end pump (Rated capacity (USgpm) at 1200 rpm, 6.9 bar (100 psl)

Frame size Code Cm/r In/r
3520v 25 81 4.94
30 91 5.91
35 112 6.83
38 121 7.73
  1. Port connection
    A- SAE 4 bolt Flange
    Part Connections
    Note: Standard right hand shaft rotation cartridges shown reverse for left hand rotation.

  2. Port Connection modifier
    M — Metric port connection (4 bolt flange)
    Omit — Inch thread port connection (4 bolt flange)

  3. Geometric displacement
    Cover end pump
    (Rated capacity (USgpm) at 1200 rpm, 6.9 bar (100 psi)

Frame size Code Cm/r In/r
3520v 2 6.5 0.40
5 18 1.10
8 27 1.67
11 36 2.22
12 40 2.47
14 45 2.78
  1. Mounting
    F-Foot mounting

  2. Shaft
    1- Straight Keyed
    11 -Splined
    86-heavy duty straight Keyed
    192N- Staight Keyed (M pilot only)

  3. Port orientation
    (Viewed from cover end of pump)
    With no. 1 outlet opposite inlet
    AA – No. 2 outlet 135° CCW from inlet
    AB – No. 2 outlet 45° CCW from inlet
    AC – No. 2 outlet 45° CW from inlet
    AD – No. 2 outlet 135° CW from inlet
    With no. 1 outlet 90° CCW from inlet
    BA – No. 2 outlet 135° CCW from inlet
    BB – No. 2 outlet 45° CCW from inlet
    BC – No. 2 outlet 45° CW from inlet
    BD – No. 2 outlet 135° CW from inlet
    With no. 1 outlet inline with inlet
    CA – No. 2 outlet 135° CCW from inlet
    CB – No. 2 outlet 45° CCW from inlet
    CC – No. 2 outlet 45° CW from inlet
    CD – No. 2 outlet 135° CW from inlet
    With no. 1 outlet 90° CW from inlet
    DA – No. 2 outlet 135° CCW from inlet
    DB – No. 2 outlet 45° CCW from inlet
    DC – No. 2 outlet 45° CW from inlet
    DD – No. 2 outlet 135° CW from inlet

  4. Design

  5. Rotation
    (Viewed from shaft end of pump)
    L — Left hand for counterclockwise
    R — Right hand for clockwise

NOTE
To reverse cartridge kit rotation, remove the two screws and reverse the location of the inlet support plate and the outlet support plate. Reinstall the two screws hand tight. Use pump cover to align all sections of the cartridge. Carefully remove the cover and tighten the screws.

When ordering spare cartridge parts, it is recommended they be obtained in cartridge kits. Kits are assembled and tested for either right or left hand rotation. If left hand rotation is required, it should be specified on parts order by adding suffix “12 to cartridge kit number.

Products we offer

  • Cartridge valves
  • DCV directional control valves
  • Electric converters
  • Electric machines
  • Electric motors
  • Gear motors
  • Gear pumps
  • Hydraulic integrated circuits (HICs)
  • Hydrostatic motors
  • Hydrostatic pumps
  • Orbital motors
  • PLUS+1′ controllers
  • PLUS+1′ displays
  • PLUS+1′ joysticks and pedals PLUS+1′ operator interfaces
  • PLUS+1′ sensors
  • PLUS+1′ software PLUS+1′ software services, support and training Position controls and sensors
  • PVG proportional valves
  • Steering components and systems
  • Telematics

Danfoss Power Solutions:

is a global manufacturer and supplier of high-quality hydraulic and electric components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off highway market as well as the marine sector. Building on our extensive applications expertise, we work closely with you to ensure exceptional performance for a broad range of applications. We help you andother customers around the world speed up system development, reduce costs and bring vehicles and vessels to market faster. Danfoss Power Solutions – your strongest partner in mobile hydraulics and mobile electrification.

Go to www.danfoss.com for further product information.:

We offer you expert worldwide support for ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide you with comprehensive global service for all of our components

.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals