FLOTIDE SB Series Swimming Pool Pump Installation Guide

June 11, 2024
FLOTIDE

FLOTIDE SB Series Swimming Pool Pump

Product Information

The FLOTIDE pump is an electrically powered pump suitable for various applications such as swimming pools, fountains, and aquariums. The pump must be installed by a qualified electrician or contractor and wired to the main power supply with the correct rating. The pump mount must be solid, level, rigid, and free from vibration. It must also allow the use of short, direct suction pipes, have flowgates in suction and discharge piping, adequate floor drainage, and protection from excess moisture. The pump suction and discharge connections have moulded-in thread stops, and users should not attempt to screw the pipe beyond these stops. Running the pump dry may damage seals, causing leakage and flooding. Therefore, users should fill the pump with water before starting the motor. Routine maintenance of the pump is necessary to ensure its optimal performance. If the pump experiences any issues, users should refer to the troubleshooting section of the manual. For service and repair parts, users should contact their local agent or dealer and provide unit nameplate data or serial number on the label and a description of the part.

Product Usage

To use the FLOTIDE pump:

  1. Ensure that only a qualified electrician or contractor installs the pump and wiring.
  2. Ensure that the pump mount is solid, level, rigid, and free from vibration.
  3. Ensure that the pump suction and discharge connections do not exceed the moulded-in thread stops.
  4. Fill the pump with water before starting the motor to prevent damage to seals.
  5. Stop the pump before removing the lid and close gate valves in suction and discharge pipes. Release all pressure from the pump and piping system before tightening or loosening screws.
  6. Avoid blocking the pump suction to prevent severe or fatal injury. Children using the pool must always have close adult supervision.
  7. Maintain the pump regularly for optimal performance.

INSTALLATION

Only qualified, licensed electrician or contractors should install pump and wiring.

IMPORTANT NOTICE
All FLOTIDE pumps must be wired to the main power supply with correct rating and by a certified electrician. Installation of electrical items must comply with Local Rules and Ordinances. Below information are for reference only:

  • Local Rules (UK): According to BS7671
  • Local Rules (NL): According to NEN1010
  • Local Rules (Be ): According to ARE 50

Pump Mount Must:

  • Be solid, level, rigid and free from vibration.
  • Allow use of short, direct suction pipe. (To reduce friction losses & do not install the pump at more than 3M geometrical height from water level)
  • Flowgates should be used in suction and discharge piping.
  • Have adequate floor drainage to prevent flooding.
  • Be protected from excess moisture.
  • All adequate access for pump and piping servicing.

NOTICE:
Pump suction and discharge connections have moulded in thread stops, DO NOT try to screw pipe in beyond these stops.

OPERATION

CAUTION
Hazardous suction. Can trap hair or body part, causing severe injury or death. Do not block suction.

  • NEVER run pump dry! Running pump dry may damage seals, causing leakage and flooding! Fill pump with water before starting motor.

  • Before removing lid:
    STOP PUMP before proceeding. CLOSE GATE VALVES in suction and discharge pipes. RELEASE ALL PRESSURE from pump and piping system. NEVER tighten or loosen screws while pump is operation.

  • Do not block pump suction! To do so with bod mav cause severe or fatal injury. Children using pool must ALWAYS have close adult Supervision!

Priming Pump:

  • Release all air from filter and piping system: see filter owner manual.
  • In a flooded suction system (water source higher than pump), pump will prime itself when suction and discharge valves are opened.
  • If pump is not in a flooded suction system, unscrew and remove trap cover; fill trap and pump with water.
  • Clean and inspect Ring; re-install on trap cover.
  • Replace trap cover on trap; turn clockwise to tighten cover.

NOTICE : Tighten trap cover by hand only. Pump should prime now. Priming time will depend on vertical length of suction lift and horizontal length of suction piping.

Routine Maintenance

The only routine maintenance needed is inspection/cleaning of trap basket. Debris or trash that collects in basket, will choke off water flow through the pump. Follow instructions below to clean trap:

  1. Stop pump, close gate valve in suction and discharge, and release all pressure from system before proceeding.
  2. Unscrew trap lid (turn counterclockwise).
  3. Remove strainer basket and clean. Be sure all holes in basket are clear, flush basket with water and replace in trap with large opening at pipe connection port (between ribs provided). If basket is replaced backwards cover will not fit on trap body.
  4. Clean and inspect lid Ring; reinstall on trap cover.
  5. Clean Ring groove on trap body and Replace lid. To help keep lid from sticking, tighten hand tight only.
  6. Prime pump (see priming instructions above)

SERVICE & REPAIR PARTS

Refer all service to your local agent or dealer as his knowledge of your equipment makes him the vest qualified source of information. Order all repair parts through your dealer. Give the following information when ordering repair parts:

  1. Unit nameplate data or serial number on label.
  2. Description of part.

TROUBLE SHOOTING

MOTOR DOES NOT START

  1. Disconnect switch or circuit breaker in off position
  2. Fuses blown or thermal overload open
  3. Locked motor shaft
  4. Motor windings burned out
  5. Defective starting switch inside sing| phase motor
  6. Disconnected or defective wiring
  7. Low voltage

PUMP DOES NOT REACH FULL SPEED

  1. Low voltage
  2. Pump connected for wrong voltage

MOTOR OVERHEATS (protector trips)

  1. Low voltage
  2. Motor windings connected for wrong voltage on dual voltage model
  3. Inadequate ventilation

PUMP DELIVERS NO WATER

  1. Pump is not primed
  2. Closed valve in suction or discharge line
  3. Leakage or air into suction system
  4. Impeller clogged

LEAKAGE OF WATER AT SHAFT
Shaft seal requires replacement

LOW PUMP CAPACITY

  1. Valve in suction or discharge line partly closed
  2. Suction or discharge line partly plugged
  3. Suction or discharge line too small
  4. Plugged basket in skimmer or hair and lint strainer
  5. Dirty filter
  6. Impeller clogged

HIGH PUMP PRESSURE

  1. Discharge valve or inlet fittings closed too much
  2. Return lines too small
  3. Dirty filters

NOISY PUMP AND MOTOR

  1. Plugged basket in skimmer or hair in lint strainer
  2. Worn motor bearings
  3. Valve in suction line partly closed
  4. Suction line partly plugged
  5. Vacuum hose plugged or too small
  6. Pump not supported properly

AIR BUBBLES AT INLET FITTINGS

  1. Leakage of air into suction line at connections or valve stem
  2. Cover gasket of hair and lint strainer needs cleaning
  3. Low water level in pool

NOTE : If the recommendations in the trouble shooting portion of this manual do not solve your particular problem(s), please contact your local dealer for service.

PARTS OF PUMP

Key NO.| Part NO.| Product Description| QTY| Key NO.| Part NO.| Product Description| QTY
---|---|---|---|---|---|---|---
1| 01021008| Nut for lid| 1| 17| 01021013| SB Pump Flange| 1
2| 01041022| Transparent Lid| 1| 18| 03011080| M6×15 Hexagonal Bolt| 16
3| 02011085| O-Ring for lid| 1| 19| 02011099| Motor Slinger for SB10;SB15| 1
4| 01111030| Basket| 1| 02011101| Motor Slinger for SB20;SB30| 1
5| 89021305| Pre-filter body| 1|

20

| 89021301| Motor SB10(230V/50HZ)| 1
6| 89280103| 2.0″Union| 2| 89021302| Motor SB15(230V/50HZ)| 1
7| 89021307| Drain Plug With O-ring| 1| 89021303| Motor SB20(230V/50HZ)| 1
8| 02011115| Square gasket| 1| 89021304| Motor SB30(230V/50HZ)| 1
9| 03011083| M630 Screw for pump body| 4| 89021601| Motor SB10(400V/50HZ)| 1
10| 89021308| SB Pump body| 1| 89021602| Motor SB15(400V/50HZ)| 1
11| 89021309| Screw for impeller with O-ring| 1| 89021603| Motor SB20(400V/50HZ)| 1
12| 02011108| O-Ring for diffuser| 1| 89021604| Motor SB30(400V/50HZ)| 1
13| 01111015| Diffuser| 1| 21| 89021310| M8
20 Bolt for motor with washer| 4

14

| 01311004| Impeller SB10(230V/50HZ)| 1| 22| 01021021| Opening key| 1
01311005| Impeller SB15(230V/50HZ)| 1| 23| 01111032| Base with nut & washer for SB10;SB15| 1
01311003| Impeller SB20(230V/50HZ)| 1| 01111031| Base with nut & washer for SB20;SB30| 1
01311006| Impeller SB30(230V/50HZ)| 1| 24| 89021312| Cable Box for SB Pump 230V/50HZ;400V/50HZ.| 1
01311004| Impeller SB10(400V/50HZ)| 1| 25| 01031008| Fan Cover for SB20,SB30 Pump| 1
01311005| Impeller SB15(400V/50HZ)| 1| 01031009| Fan Cover for SB10,SB15 Pump| 1
01311003| Impeller SB20(400V/50HZ)| 1| 26| 01031007| Cooling fan for SB10,SB15 Pump| 1
01311006| Impeller SB30(400V/50HZ)| 1| 01031006| Cooling fan for SB20,SB30 Pump| 1
15| 04015001| 3/4″Mechanical seal| 1|

27

| 04016014| Capacitor for SB10,SB15 Pump| 1
16| 02011093| O-Ring for flange| 1| 04016015| Capacitor for SB20 Pump| 1
04016016| Capacitor for SB30 Pump| 1

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals