VULCAN C36IRB Salamander Broilers Instruction Manual
- June 4, 2024
- Vulcan
Table of Contents
VULCAN C36IRB Salamander Broilers
IMPORTANT FOR YOUR SAFETY
THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS
EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF
THE EQUIPMENT COVERED BY THIS MANUAL.
POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE
SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS
SUPPLIER.
IMPORTANT
IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND
CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
WARNING : IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
IN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO OPERATE THIS DEVICE.
INSTALLATION, OPERATION, AND CARE OF SALAMANDER BROILERS GENERAL
Salamander Broilers are produced with quality workmanship and material. Proper
installation, usage, and maintenance of your broiler will result in many years
of satisfactory performance.
It is suggested that you thoroughly read this entire manual and carefully
follow all of the instructions provided.
Accessories are sold separately for the Salamander Broiler:
Radiant Altitude Kits
Accessory Number| Description
ALTISR-N01| KIT, RB ALTITUDE NG SEA-1999FT
ALTISR-P02| KIT, RB ALTITUDE LP SEA-1999FT
ALTISR-N03| KIT, RB ALTITUDE NG 2000-3999FT
ALTISR-P04| KIT, RB ALTITUDE LP 2000-3999FT
ALTISR-N05| KIT, RB ALTITUDE NG 4000-6999FT
ALTISR-P06| KIT, RB ALTITUDE LP 4000-6999FT
ALTISR-N07| KIT, RB ALTITUDE NG 7000-8999FT
ALTISR-P08| KIT, RB ALTITUDE LP 7000-8999FT
ALTISR-N09| KIT, RB ALTITUDE NG 9000-10000FT
ALTISR-P10| KIT, RB ALTITUDE LP 9000-10000FT
Common Accessories
Accessory Number| Description
WALLMNT-CHRBKR| SST WALL MOUNT BRACKETS
COUNTER-ADJLEG| SET OF (4) 6” ADJUSTABLE LEGS
CONNECT-CHALL| KIT, SALAMANDER INTERPLUMBING
Infrared Altitude Kits
Accessory Number| Description
ALTISI-N01| KIT, RB ALTITUDE NG SEA-1999FT
ALTISI-P02| KIT, RB ALTITUDE LP SEA-1999FT
ALTISI-N03| KIT, RB ALTITUDE NG 2000-3999FT
ALTISI-P04| KIT, RB ALTITUDE LP 2000-3999FT
ALTISI-N05| KIT, RB ALTITUDE NG 4000-6999FT
ALTISI-P06| KIT, RB ALTITUDE LP 4000-6999FT
ALTISI-N07| KIT, RB ALTITUDE NG 7000-8999FT
ALTISI-P08| KIT, RB ALTITUDE LP 7000-8999FT
ALTISI-N09| KIT, RB ALTITUDE NG 9000-10000FT
ALTISI-P10| KIT, RB ALTITUDE LP 9000-10000FT
INSTALLATION
Before installing, verify that the type of gas supply (natural or propane) agrees with the specifications on the rating plate located underneath the broiler rack drip tray. If the supply and equipment requirements do not agree, do not proceed with the installation. Contact your dealer immediately.
UNPACKING
- Immediately after unpacking, check for possible shipping damage. If the broiler is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.
- Before installing, verify that the type of gas (natural or propane) and the clearance dimensions (see below) agree with the specifications on the rating plate which is located under the crumb tray on the right side.
LOCATION
The equipment area must be kept free and clear of combustible substances.
Minimum Clearance /Combustible Construction/ Non-Combustible Construction
- Rear /0”/ 0”
- Sides (Infrared) 36IRB & C36IRB/ 2”/ 0”
- Sides (Radiant) 36RB & C36RB/ 6”/ 0”
- Bottom /4” with legs/ 0
The installation location must allow adequate clearances for servicing and
proper operation. A minimum front clearance of 24″ is required.
Do not obstruct the flow of combustion and ventilation air. Adequate clearance
for air openings into the combustion chamber must be provided. Make sure there
is an adequate supply of air in the room to replace air taken out by the
ventilating system. Do not permit fans to blow directly at the broiler. Avoid
wall-type fans which create air cross currents within the room. Avoid open
windows next to the broiler. Allow for maximum clearance between the flue and
hood ventilation system as per NFPA 96 requirements. Minimum 18” clearance is
recommended for proper operation and for compliance with local building and
fire codes.
INSTALLATION CODES AND STANDARDS
The broiler must be installed in accordance with:
In the United States of America:
In the United States of America:
-
State and local codes.
-
National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained from The American Gas Association Accredited Standards Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-7471
NOTE : In the Commonwealth of Massachusetts All gas appliances vented through a ventilation hood or exhaust system equipped with a damper or with a power means of exhaust shall comply with 248 CMR. -
NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. In Canada:
- Local codes.
- CAN/CSA-B149.1 Natural Gas Installation (latest edition)
- CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3
GAS CONNECTIONS
CAUTION : All gas supply connections and any pipe joint compound used
must be resistant to the action of propane gases.
Codes require that a gas shutoff valve be installed in the gas line ahead of
the broiler.
NATURAL GAS: Standard orifices are set at 5″ W.C. (Water Column). A
pressure regulator is supplied and must be installed when the broiler is
connected to the gas supply.
PROPANE GAS: Standard orifices are set at 10″ W.C. (Water Column). A
pressure regulator is supplied and must be installed when the broiler is
connected to the gas supply.
The gas supply line must be ¾” or larger. If flexible or semi-rigid
connections are used, the inside diameter must be the equivalent of ¾” iron
pipe or larger. All connections of the flexible and semi-rigid type must
comply with all local and national requirements. Make sure gas piping is clean
and free of dirt, piping compound, and obstructions.
WARNING : PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR
LEAKS. USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME. After piping has
been checked for leaks, all piping receiving gas should be fully purged to
remove air.
GAS PRESSURE REGULATOR INSTALLATION
Gas regulator pressure is preset at 5” Water Column (W.C.) for natural gas,
and 10” W.C. for propane gas. Minor adjustments may be required based on site
specific gas pressure.
Install the regulator as close to the broiler on the gas supply line as
possible. Make sure that the arrow on the underside of the regulator is
oriented in the direction of gas flow to the broiler (Fig. 1) and the
regulator is positioned with the vent plug and adjustment screw upright (Fig.
2). A recommended plumbing schematic is listed below only for Salamander units
as a guide to the installer and ITW Cooking Equipment or Hobart is in no way
liable for plumbing installation (Fig. 3).
The minimum supply pressure (upstream of the regulator) should be 7-9” W.C. for natural gas and 11-12” W.C. for propane gas. At no time should the regulator be connected to supply pressure greater than ½ psig (3.45 kPa) or 14” W.C.
FLUE CONNECTIONS
- DO NOT obstruct the flow of flue gases from the flue located on the rear of the broiler. It is recommended that the flue gases be ventilated to the outside of the building through a ventilation system installed by qualified personnel.
- Information on the construction and installation of ventilating hoods may be obtained from the standard for “Vapor Removal from Cooking Equipment,” NFPA No. 96 (latest edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
ASSEMBLY
- Salamander Broiler Mounted on a Wall (Fig. 4).
The separate wall mounting bracket accessory (WALLMNT-CHRBKR) will be needed to wall mount the unit.
- Follow the combustible/non-combustible clearance guidelines that are listed in the “Installation” section in this manual.
- Make sure brackets are level and properly spaced so that bracket holes will align with the threaded holes on the bottom of the unit to be mounted. The short leg of the bracket with the holes that are nearest the elbow bend is to be placed against the wall. (Fig. 5)
- Secure brackets to the wall by means of lag screws or bolts. (Fig. 5)
- Mount the brackets only in the upside-down “L” position as shown. (Fig. 5)
- Make sure the lag bolts or screws engage wall studs. Ensure that the wall construction is of the type that will support the salamander weight.
- Place the salamander into position on the brackets, making sure that the unit’s bottom threaded attachment points are aligned with the holes in the brackets.(Fig. 6)
- Secure the unit into position with 3/8” bolts at the bottom of the unit. Thread the bolts through the holes in the brackets and into the threaded attachment points on the bottom of the unit. (Fig. 6)
Radiant & Infrared Salamander shown on WALLMNT-CHRBKR Accessory
Assembly over a Gas Range (Fig. 7)
If the broiler is to be mounted over a gas range, a reinforced shelf and
special mounting brackets are required.
- Use Instructions from RSHELF Accessory kit to install reinforced shelf over a range.
- Using the four bolts provided, install mounting brackets on both top corners of the reinforced shelf.
- Place and align the broiler on top of brackets with the back of the unit flush with the rear of the shelf.
- Install 3/8-16 Bolts through the underside of the RSHELF.
Radiant & Infrared Salamander shown on RSHELF Accessory
OPERATION
WARNING : THE BROILER AND ITS PARTS ARE HOT. BE CAREFUL WHEN OPERATING, CLEANING, OR SERVICING THE BROILER.
CONTROLS
- Dual Zone Controls — Controls cooking areas in the left and right-hand side of the cavity allowing for flexibility and premium cooking performance.
- Angled Handle — elevates or lowers the broiling grid to different positions. Grasp the handle and pull towards the broiler cavity. This releases the mechanism and allows the lifting handle to move into the desired position.
- Burner Valve — regulates the flow of gas to the burners. Gas flow is increased by turning the valve counterclockwise.
- Drip Tray — Collects grease and waste which is diverted by the tilt of the drip shield. DO NOT allow the drip tray to overflow. Empty the drip tray when three-quarters full to reduce the possibility of spillage.
- Rack Handle — glides the grid forward for easy loading and unloading. To operate, pull straight out.
LIGHTING, RELIGHTING AND SHUTDOWN INSTRUCTIONS
- Turn burner valve to the OFF position and wait 5 minutes.
- Light the pilot adjacent to the main burner. Adjust the pilot valve screw until the pilot flame has a slight yellow tip. There are two pilots to light, on each end of the cooking chamber.
- After the pilot has been established, turn the burner valve to the ON position. The burner flames may be adjusted, using the air shutters located behind the manifold cover in the front of the range. There are no shutters on the IRB models.
- If the burners fail to light, turn off all valves, wait 5 minutes and repeat steps 1-3.
- To shut down, turn the burner valves to the OFF position.
RACK POSITION AND GAS SETTING
Each operator will find the optimum rack position and gas setting for various products; however, it is recommended that gas input be reduced first when lower rack temperatures are desired. Further reduction in rack temperatures, if necessary, can then be obtained by lowering the rack position. Infrared Models must use the full gas setting. Max and minimum temperatures can be achieved at the following settings:
- 2 Burners On, rack at the highest position, valves set to High – 800°F
- 1 Burner On, rack at the lowest position, valves set to Low – 250°F
CLEANING
- Allow the broiler to cool.
- To remove broiler rack for cleaning, adjust broiler rack to the center position.
- Position left and right hands simultaneously on the edges of the broiler rack and raise both rack stops.
- Slide broiler rack and drip tray forward past rack stop, (which must be pivoted out of the way) holding the tray up against racks.
- Remove broiler rack and drip tray from broiler.
- Let the back of tray drop-down to vertical to allow front hooks to disengage.
- Remove drip pan from broiler rack and clean as you would any normal utensil, using care not to damage the front hooks
- To replace, hook the drip tray to the broiler rack while the tray is in a vertical position.
- Replace broiler rack and drip tray in side channels while holding the tray up close to rack.
- Clean bottom pan. Slide pan out and wash with soap and water. Rinse thoroughly and wipe dry with a soft clean cloth.
- Clean stainless steel surfaces with a mild detergent and water, using a damp cloth, or with a commercial stainless steel cleaner. Rinse thoroughly and wipe dry with a soft clean cloth.
- Burner ports and throats should be thoroughly cleaned. Venturi must be free from grease and lint. DO NOT insert pick in burner port holes.
MAINTENANCE
WARNING : THE BROILER AND ITS PARTS ARE HOT. BE CAREFUL WHEN OPERATING, CLEANING, OR SERVICING THE BROILER.
LUBRICATION
Burner valve stems must be lubricated. Upon sticking, a burner valve stem should receive maintenance from your local authorized servicer.
PILOT LIGHTS
Pilot lights are to be kept clean and adjusted at the proper flame height.
VENT
Annually, when the broiler is cool, check the flue and clear any obstructions.
SERVICE AND PARTS INFORMATION
Contact your local Service Agency to obtain service and parts information.
MODELS
- 36RB
- 36IRB
- www.vulcanequipment.com
MODELS
- C36RB
- C36IRB
- www.wolfequipment.com