feyree Level 2 EV Charger User Manual
- June 17, 2024
- feyree
Table of Contents
EV Charging Station
Manual
Itis recommended to read the instructions before use
Safety instructions
Warning : Do not place flammable or explosive materials, chemicals,
combustible gas or other hazardous materials near the charging station
Warning – Keep the charging gun head clean and dry, if dirty, please wipe
it with a clean and dry cloth, it s strictly forbidden to touch the charging
gun core by hand when itis charging
Warning: Itis strictly forbidden to use the charging post when the
charging gun or charging cable is defective, cracked, worn, broken or when the
charging cable is exposed
Warning : Do not attempt to disassemble, repair or modify the charging
post. If you have a need for repair or modification, please contact the staff,
improper operation may cause damage to the equipment, such as water leakage
and electricity leakage, etc
Warning : In case of thunderstorm, please charge carefully
Warning : Children should not approach or use the charging station during
the charging process to avoid injury
Warning – During the charging process, the vehicle is prohibited from
driving and charging is only possible when it is stationary. For hybrid trams,
please turn off the engine before charging
Warning – In case of emergency during the operation of the product, press
the emergency stop button immediately to cut off all input and output power
Warning : The use of the charging post is prohibited in the following
cases and the manufacturer should be contacted immediately:
- Bad charging pile shell
- Defects, cracks, wear and tear, ruptures, exposed charging cables on charging guns or charging cables
- Lightning strikes charging post
- Accidents or fires near charging stations
- Water in the charging pile
- The length of the charging pile gun cable is not long enough to connect to the vehicle, an extension cable needs to be installed
Product Overview
Brief description :
This product is used for electric vehicle AC charging, whose design is highly
simple, including Type2, Type1, GB/T 20234 three kinds of specifications. Itis
equipped with RFID card, plug and play charging methods and multiple safety
protection functions. NEMA4 (IP66) protection rating provides safe and
reliable indoor and outdoor usage in any climate with excellent dustproof and
waterproof grade
Type 1 Parameter introduction
Type 1 SAEJ1772
Power Rating | 7.6KW | 9.6KW |
---|---|---|
APP | ||
RFID Card | ||
Type ARCD | ||
Power supply system | Single Phase | Single Phase |
Rated voltage | 85V-264V | 85V-264V |
Adjustable current | 8-10-13-16-25-32A | 13-16-25-32-40A |
Input Frequency | 47H2~63Hz | 47Hz~63Hz |
Protection level | NEMA 4 (IP66) | NEMA 4 (iP66) |
Working temperature | -22°F ~131°F | -22°F ~131F |
Storage temperature | -40°F ~176°F | -40°F ~ 176°F |
Standby power | <3w | <3W |
Working humidity | 5% ~ 95% non-condensation | 5% ~ 95% non-condensation |
L°W*H | 17,6°13.5°7.64 in | 17.6°13.5°7.64 in |
CableSpecification | UL EVE 3°10 AWG+1″°18 AWG | UL EVE 2°8 AWG+10 AWG+1°18 AWG |
Control box function : | Product Ferformance : | |
--- | --- | |
1.Earth leakage protection (restart recovery) | 1.Charging plug according to |
SAE J1772 standard
2.0vervoltage and undervoltage protection (self-test recovery)| 2.Charging
control box in accordance with IEC 61851 control principle
3.Lightning protection| 3.Insulation resistance: >1000Q
4.0vercurrent protection| 4.Terminal temperature rise: <50K
5.0verheat protection| 5.Mechanical life: no-load plugging and unplugging
times > 10000 times
6.Grounding protection| 6.External impact: can withstand a 1-meter drop and 2
tons of vehicle crushing
7.RFID card function (optional and can be set according to user needs)|
7.Altitude: £2000m
8.Appointment Time| 8.With emergency stop function
9.Connectivity : WIFI, Bluetooth|
Type 2 Parameterintroduction
Power Rating | 7.6KW | 11KW | 22KW |
---|---|---|---|
Load balancing | / | / | |
APP | / | ||
RFID Card | / | ||
Type ARCD | / | ||
/ | / | ||
Type B RCD | / | / | |
Power supply system | Single Phase | Three Phase | Three Phase |
Rated voltage | 85V-264V | 380V+20% | 380V420% |
Adjustable current | 8-10-13-16-25-32A | 8-10-13-16A | 8-10-13-16-25-32A |
Input Frequency | 47Hz~63Hz | 47Hz~63Hz | 47Hz~63Hz |
Protection level | NEMA 4 (IP66) | NEMA 4 (IP66) | NEMA 4 (IP66) |
Working temperature | -22°F ~131°F | -22°F ~131F | -22°F ~131F |
Storage temperature | -40°F ~176°F | -40°F ~176°F | -40°F ~176°F |
Standby power | <3W | <3W | <3W |
Working humidity | 5% ~ 95% non-condensation | 5% ~ 95% non-condensation | 5% ~ |
95% _ non-condensation
L°WH| 17.6°13.5°7.64 in| 17.6°13.5°7.64 in| 17.6°13.5°7.64 in
Cable Specification| 3G 6mm?+ 10.5mm?| 5G 2.5mm?+ 10.5mm?| 5G 6mm?+ 1*0.5mm2
Control box function :| Product Performance :
---|---
1.Earth leakage protection (restart recovery)| 1.Charging plug according to
IEC 62196-2 standard
2.0vervoltage and undervoltage protection (self-test recovery)| 2.Charging
control box in accordance with IEC 61851 control principle
3.Lightning protection| 3.Insulation resistance: >10000
4.0vercurrent protection| 4.Terminal temperature rise: <50K
5.0verheat protection| 5.Mechanical life: no-load plugging and unplugging
times > 10000 times,
6.Grounding protection| 6.External impact: can withstand a 1-meter drop and 2
tons of vehicle crushing
7.RFID card function (optional and can be set according to user needs)|
7.Altitude: £2000m
8.Appointment Time| 8.With emergency stop function
9.Connectivity : WIFI, Bluetooth| 1
GB/T 20234 Parameterintroduction
GB/T 20234
Power Rating | 7.6KW | 11KW | 22KW |
---|---|---|---|
Load balancing | / | / | |
APP | / | ||
RFID Card | / | ||
Type ARCD | / | ||
Type 8 RCD | / | / | |
/ | |||
Posysien | Single Phase | Three Phase | Three Phase |
Rated voltage | 85V-264V | 380V+20% | 380V420% |
Adjustable current | 8-10-13-16-25-32A | 8-10-13-16A | 8-10-13-16-25-32A |
Input Frequency | 47Hz~63Hz | 47Hz~63Hz | 47Hz~63Hz |
Protection level | NEMA 4 (IP66) | NEMA 4 (IP66) | NEMA 4 (IP66) |
Working temperatere | -22°F ~131°F | -22°F ~131F | -22°F ~131F |
Storage tempardture | -40°F ~176°F | -40°F ~176°F | -40°F ~176°F |
Standby power | <3W | <3W | <3W |
Working humidity | 5% ~ 95% non-condensation | 5% ~ 95% non-condensation | 5% ~ |
95% _ non-condensation
LWH| 17.6°13.5°7.64 in| 17.6°13.5°7.64 in| 17.6°13.5°7.64 in
Cable Specifizstion| 3G 6mm?+ 10.5mm?| 5G 2.5mm?+ 10.5mm?| 5G 6mm?+ 1*0.5mm2
Control box function :| Product Performance :
---|---
1.Earth leakage protection (restart recovery)| 1.Charging plug according to
GB/T 20234 standard
2.0vervoltage and undervoltage protection (self-test recovery)| 2.Charging
control box in accordance with GB/T 18487 control principle
3.Lightning protection| 3.Insulation resistance: >10000
4.0vercurrent protection| 4.Terminal temperature rise: <50K
5.0verheat protection| 5.Mechanical life: no-load plugging and unplugging
times > 10000 times,
6.Grounding protection| 6.External impact: can withstand a 1-meter drop and 2
tons of vehicle crushing
7.RFID card function (optional and can be set according to user needs)|
7.Altitude: £2000m
8.Appointment Time| 8.With emergency stop function
9.Connectivity : WIFI, Bluetooth|
Operating Instructions
Pre-use preparation :
- Ensure that there are no open flames around the equipment and that the surrounding space is not blocked
- Ensure that the equipment casing and charging gun cable are not damaged
- Ensure proper maintenance of equipment
- Make sure the emergency stop button is popped up, if it has been pressed, turn the knob in the direction of the knob arrow to return to the popped up state
Charging steps :
(1) Standby status
- When the charging pile is in standby mode, the interface shows that the device is ready for charging, as shown in the figure below:
- The indicator light on the case (for Wi-Fi function only) is green and always on;
(2) Waiting for card swipe status
-
After parking the electric vehicle into the station, take the charging gun from the gun holder of the charging post (optional) and insert it into the connector of the electric vehicle.Please make sure thatitis inserted in place and the connection is safe and reliable. When the charging gun monitors that the charging gun is inserted correctly It will enter the status of identity verification, as shown in the following figure :
-
The indicator light on the screen (for Wi-Fi function only) is flashing green;
-
Start-up device
-
Swipe RFID card to authorize the use of charging posts
(4) Startcharging
- The device starts charging and the interface displays the charging status and information parameters as shown in the following figure .
- The indicator light on the screen (for Wi-Fi function only) is green breathing .
(5) Stop charging
- When the vehicle is fully charged, the charging post will automatically stop charging; in case of emergency, you can manually press the Emergency stop button to cut off power.
- RFID card can also be used to stop the charging
- When charging is complete, the end screen has the following two displays:
- The indicator light on the screen (for Wi-Fi function only) is green flashing or always on
Key Operation Instructions :
-
How to set the charging current ?
Touch the panel to adjust the charging current,
and then insert the charging gun into the vehicle and swipe the RFID card to start charging. The device will output the corresponding output current. Different models come with different range of adjustable current. -
How to set time delay charging ?
Touch the panel icon area to set the delayed charging time, which can be set from 110 15 hours. Each press adds one hour. Insert the charging gun into the vehicle and swipe the RFID card. Then the device will start charging after “X” hours. -
How to set automatic charging duration ?
You can set the charge duration before plugging in the charging connector as below. After the connector plugged in and the RFID card swiped, the device will charge for “X”hours according to the timing time and auto-stop time’s up. The automatic charging duration can be set from 1 to 15 hours.Each touch will increase 1 hour. -
How to access the menu homepage ?
1. Press and hold the touch pad icon area for 5 seconds in any case to access the setting page -
Menu page basic key operation
1. Touch the icon area to move up, move down, enter, exit and increase or decrease the parameters of the menu
Note: When the gun is plugged in, it is not possible to enter the charging plan and load balance setting function.Need to pull out the gun first -
Charging plan page
Set current:Set charging current
Delay on:Turn on delayed charging
Delay off:Turn off delayed charging
RFID:Turn on or off the card swipe function
Entering the RFID setting will prompt the need to swipe the card first for identity verification.Within 10s to complete the card swipe operation, the card swipe function would be turned on or off. -
Load Balancing PageRated current:Setting the home circuit current rating
Load balancing function description
1. Introduction:
By connecting the meter to the home circuit circuit, the current level of the home circuitis collected in real time, and the collected data information is transmitted remotely to the charging device through 485 communication. The current in real time by comparing the collected data with the rated current of the home circuit set by the user, and when the available current is less than 6A, the device will enter the load balancing protection state.When the available current is greater than 10A, the device will resume charging.
2. Prerequisites for the load balancing function to work properly:
(1) 485 communication is correctly and reliably connected
(2) The charging pile is not on the same circuit as the meter and the meter is on the same circuit as other household appliances
(3) The rated current of the home circuit set on the charging post matches the actual
3. Set the home rated current level:
You need to follow the prompts for swipe operation before entering the modification to open the home rated current setting, setable range from 20A to 80A. -
Device Information Page
1. This page contains basic information about this device and additional charging information parameters, the icons are explained as follows: -
How to use the App (the device needs to have Wifi function, optional function)
1. Please download the ” Tuya Smart ” App on your cell phone, the icon is shown on the right :
2. After downloading, open the app, turn on your phone WiFi and Bluetooth, select Add Device, and follow the instructions to complete adding a new device, as shown below: -
Interface description (device should have Wifi or load balancing function, optional function)
7.6KW/9.6KW/interface as shown below
Installation and operation instructions
Step 1: according to the size of the steel pegboard hole using an electric drillin the wall suitable height to open the hole, then put in the expansion tube, and then use long screws to fix the steel pegboard (large) on the wall Step 2: Mount the steel pegboard (small) on the device using the short screw After the lower part, hang the equipment on the steel pegboard (large) and use long screws ornails to fix the steel pegboard (small) to the wall Step 3: Just below the equipment, install the charging connector holder,Recommended mounting height 31.5 inch from the floorStep 4: Turn on the power and confirm that the indicator lights (optional) and display are working properly
Common Troubleshooting
Fault name| Possible causes of fault phenomena|
Troubleshooting recommendations
---|---|---
AC
overvoltage| AC input voltage| 1.Ask an electrician to test the input voltage
of the switch
2.If the actual voltage exceeds 264VAC for a short time, wait for the network
to return to the normal voltage range on its own
3.If the actual voltage is greater than 264V AC for a long time, please
contact the power supply department
4.If the actual voltage is less than 264V AC, please contact us
AC
Undervoltage| AC input voltage is too low| 1.Ask an electrician to test the
input voltage of the switch
2.If the voltage is below 176V AC for a short time, wait for the voltage to
return to the normal range
3.If the actual voltage is less than 176V AC for a long time, please contact
the power supply department
4.If the actual voltage is greater than 176V AC, please contact us
AC
Overcurrent| AC input current is too high| 1.Immediately disconnect the power
distribution box leakage / overcurrent protection switch
2.Check whether there is a low impedance connection between the two lines of
the AC pile output line
3.After eliminating the above problems, reapply power, if the fault still
exists, please contact us
overheating| Internal temperature greater than| 1.Check the AC pile
installation environment, verify that there is no heat generating equipment or
devices next to it, and ensure that the ambient temperatureneeds to be below
60°.
2.If the fault cannot be eliminated, please contact us
Leakage current exceeds
the standard| Leakage current| 1.Immediately disconnect the power distribution
box leakage / overcurrent protection switch
2.Check whether the AC pile output line is broken or has a low impedance
connection to ground
3.After eliminating the above problems, and reset the leakage current
protector reset switch, reapply power, if the fault still exists, please
contact us
Leakage current sensor nomaly| Sensor for detecting leakage current|
1.Immediately disconnect the power distribution box leakage / overcurrent
protection switch
2.Check whether the AC pile output line is broken or has a low impedance
connection to ground
3.After eliminating the above problems, reapply power, if the fault still
exists, please contact us
Ground fault| Poor input/outputground or input L/N reversed| 1.Immediately
disconnect the power distribution box leakage / overcurrent protection switch
2.Check whether the AC pile input/output line grounding is normal, and whether
the input L/N is connected in normal order
3.After eliminating the above problems, reapply power, if the fault still
exists, please contact us
Charge gun onnection Abnormal| Charging gun CC/CP| 1.Check whether the
connection of the charging gun is correct and reliable
2.If the fault still exists, please contact us
Charging Status and Indicator Light
Serial number| charging| Green| Blue| Red|
Definition Description
---|---|---|---|---|---
1| Ready| On| Off| Off| Power-on self-test or reset
2| Connect| Flash| Off| Off| The voltage of detection point 1 is 9 + 0.8V,
3| Charging| Off| Breathe| Off| Detection point 1 voltage is 6±0.8V. the relay
is closed
4| Finish| Off| On| Off| Charging complete
5| Err:CP| Off| Off| ,
Fault (0.5s 1 1 time
,| Detection point 1 voltage of 9.8V<U<11.2V.
6.8V<U<8.2V; 12.8V<U or U<5.2V. Relay is disconnected
6| Under Voltage| Off| Off| Fault 10.5s1 2 time| 1 phase:voltage<85V;3
phase:voltage<147V
7| Over Voltage| Off| Off| Fault 0.5s 3 time| 1 phase:voltage>264V;3
phase:voltage>457V
8| Elec Leakage| Off| Off| Fault :0.5s j 4 time| The relay is disconnected,
and it needs to be re-powered after the fault is removed before the relay is
allowed to close
9| Over Current| Off| Off| Fault 0.5s 5 time| When the line current is
le12<1.- le 14, 60S, the relay is disconnected. and it will automatically
restart after 10S. Repeat three times for permanent disconnection. When I> le
I 4, the relay is disconnected, and the charging ends
10| Over Temp| Off| Off| Fault 0.5s I 6 time| Temperature>85 degrees,
disconnect the relay, wait for the temperature <65 degrees, then turn on
charging
11| Ungrounded| Off| Off| Fault 10.5s 1 7 time| The ground wire is not
connected, the relay is disconnected. and the relay is allowed to close after
the fault is removed
Read User Manual Online (PDF format)