ARISTA CCA-ETM-Q4 Edge Threat Management Appliance User Guide

June 11, 2024
ARISTA

ARISTA CCA-ETM-Q4 Edge Threat Management Appliance

Product Information

The CCA-ETM-Q4 Appliance is a threat management device manufactured by Arista Networks. It is designed to protect networks from external threats and unauthorized access. The appliance comes with a user manual that provides instructions on installation, configuration, and usage.

Product Usage Instructions

Preparation

Before installing the CCA-ETM-Q4 Appliance, read the safety information provided by Arista Networks. Then follow the steps below:

  • Site Selection: Choose a suitable location for installing the appliance. Ensure that there is enough space around the appliance for proper ventilation.
  • Electrostatic Discharge (ESD) Precautions: Take necessary precautions to prevent ESD damage to the appliance.
  • Tools and Parts Required for Installation: Assemble all the required tools and parts before starting the installation process.

Mounting the Appliance

Follow the steps below to mount the CCA-ETM-Q4 Appliance:

  • Desktop Installation: Place the appliance on a flat surface and secure it using the provided screws.
  • Cabling the Appliance: Connect the appliance to the power source and network using the provided cables.
Configuring the Appliance

After mounting and cabling the appliance, follow the steps below to configure it:

  1. Access the appliance using a web browser.
  2. Enter the default login credentials provided in the user manual.
  3. Configure the appliance according to your network requirements.

For more information on using and maintaining the CCA-ETM-Q4 Appliance, refer to the user manual provided by Arista Networks.

Overview

Scope

  • This guide is intended for properly trained service personnel and technicians who need to install the following Arista appliances:
  • This guide is covering the CCA-ETM-Q4 appliance.

_ Important: _Only qualified personnel should install, service, or replace this equipment.

Receiving and Inspecting the Equipment

  • Upon receiving the appliance, inspect the shipping boxes and record any external damage. Retain packing materials if you suspect that part of the shipment is damaged; the carrier may need to inspect them.
  • If the boxes were not damaged in transit, unpack them carefully. Ensure that you do not discard any accessories that may be packaged in the same box as the main unit.
  • Inspect the packing list and confirm that you received all listed items. Compare the packing list with your purchase order. Parts List provides a list of components included with the appliance.

Installation Process

The following tasks are required to install and use the CCA-ETM-Q4 Appliance:

  1. Select and prepare the installation site (Site Selection).
  2. Assemble the tools and parts needed (Tools and Parts Required for Installation).
  3. Mount the appliance (Mounting the Appliance).
  4. Connect the appliance to the power source and network (Cabling the Appliance).
  5. Configure the appliance (Configuring the Appliance).

Safety Information

Refer to the Arista Networks document Safety Information and Translated Safety Warnings available at: https://www.arista.com/en/support/product- documentation.

Obtaining Technical Assistance

Any customer, partner, reseller or distributor holding a valid Arista Service Contract can obtain technical support in any of the following ways:

_ Important: _No user serviceable parts inside. Refer all servicing to qualified service personnel.

Specifications

This section lists the specifications of the CCA-ETM-Q4.

Table 1: Appliance Specifications (Dimensions and Weights)

Appliance Size (W x D x H) Weight
CCA-ETM-Q4 180mm (W) x 158mm (D) x 33mm (H) 1 kg

Table 2: Appliance Specifications (Operational and Storage)

Appliance| Operating Temperature| Storage Temperature| Operating Altitude| Relative Humidity
---|---|---|---|---
CCA-ETM-Q4| 0°- 40° C

(32°-104° F)

| -10° – 70° C (14°

– 158°F)

| 10% – 90% RH| 5% – 95% RH @

55° C

Table 3: Appliance Specifications (Power Input)

Power Source Ratings
12V/36W power adapter 100 to 240V,1.2A,50-60Hz

Preparation

Site Selection

The following criteria should be considered when selecting a site to install the appliance.

  • Temperature and Ventilation: For proper ventilation, install the appliance where there is ample airflow to the front and back of the appliance. The ambient temperature should not go below 0° or exceed 40°C.

_ Important: _To prevent the appliance from overheating, do not operate it in an area where the ambient temperature exceeds 40°C (104°F).

  • Other Requirements: Select a site where liquids or objects cannot fall onto the equipment and foreign objects are not drawn into the ventilation holes. Verify these guidelines are met:
    • Clearance areas to the front and rear panels allow for unrestricted cabling.
    • All front and rear panel indicators can be easily read.
    • Power cords can reach from the power outlet to the connector on the rear panel.

_ Important: _All power connections must be removed to de-energize the unit.

Electrostatic Discharge (ESD) Precautions

Observe these guidelines to avoid ESD damage when installing or servicing the appliance.

  • Assemble or disassemble equipment only in a static-free work area.
  • Use a conductive work surface (such as an anti-static mat) to dissipate static charge.
  • Wear a conductive wrist strap to dissipate static charge accumulation.
  • Minimize handling of assemblies and components.
  • Keep replacement parts in their original static-free packaging.
  • Remove all plastic, foam, vinyl, paper, and other static-generating materials from the work area.
  • Use tools that do not create ESD.

Tools and Parts Required for Installation

  • 1- CCA- ETM- Q4 appliance.
  • 4 – Rubber stick-on feet.
  • 1 – Power adapter.

Mounting the Appliance

Desktop Installation To install the CCA-EMT-Q4 on a desktop, complete the following steps.

  1. Attach the rubber feet to the bottom corners of the Q4 appliance.
  2. Attach the cables according to Cabling the Appliance.

Cabling the Appliance

Complete the following for the CCA-ETM-Q4 installation process.

  1. Connect an Ethernet cable from your Internet modem or router to the designated WAN port.
  2. Connect an Ethernet cable from your management computer or LAN switch to port 1.
  3. Plug in the power adapter to a power source and connect it to the power input on the rear panel.

The power adapter screws into the appliance, securing the cord.

Configuring the Appliance

You can manage your appliance using the Edge Threat Management Dashboard or from the local network.

From Edge Threat Management Dashboard

  1. Navigate your web browser to http://edge.arista.com/cmd.
  2. Log in with your Edge Threat Management Dashboard account, or click Create Account to set up an account.
  3. Navigate to the Appliances screen and click Add.
  4. Enter the serial number located on the bottom of your appliance.
  5. Click Add to confirm the new appliance.
  6. Complete the initial setup to begin managing your appliance.

From the Local Network

  1. Connect an Ethernet cable from your management computer or LAN switch to the LAN port.
  2. From your management computer, check the network status of your system and confirm that you receive an IPv4 address in the subnet of 192.168.2.0/24 (example: 192.168.2.100).
  3. In a browser, navigate to http://192.168.2.1.
  4. Follow the steps in your browser to complete the setup.

Status Indicators

The following are the Status Indicators’ locations and their functions for the front of the CCA-EMT-Q4 appliance.

A.1 Front Indicators

  1. Speed status
  2. Internet port
  3. LAN ports
  4. Hard disk
  5. Power
  6. Connection status

Parts List

Each appliance provides an accessory kit that contains parts that are required to install the appliance. This section lists the installation parts contained in the appliance accessory kit.

The CCA-ETM-Q4 package includes:

  1. 12V power supply
  2. Power cable
  3. DB9 serial to RJ49 adapter
  4. Rubber feet

Rear Panel

This section shows the rear panel of the CCA-ETM-Q4.

  1. 12V 3.3A plug-in power adapter port
  2. Factory reset
  3. Reset
  4. USB ports
  5. Internet and LAN ports
  6. RJ45 console

Regulatory Model Numbers

This appendix lists the Regulatory Model Numbers (RMNs), where applicable, for the product models for the appliances described in this document.

Table 4: Regulatory Model Numbers and Product Numbers

Regulatory Model Number (RMN) Product Number(s)
AN2209 CCA-ETM-Q4

Taiwan RoHS Information

Contact

Headquarters

Support

Sales

www.arista.com

© Copyright 2022 Arista Networks, Inc. All rights reserved. The information contained herein is subject to change without notice. The trademarks, logos and service marks (“Marks”) displayed in this documentation are the property of Arista Networks in the United States and other countries. Use of the Marks are subject to Arista Network Term of Use Policy, available at http://www.arista.com/en/terms-of-use. Use of marks belonging to other parties is for informational purposes only.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>