CROWN EC-6TW-L Self Generating Steam Jacketed Counter Tilting Kettle User Manual
- June 11, 2024
- CROWN
Table of Contents
- CROWN EC-6TW-L Self Generating Steam Jacketed Counter Tilting Kettle
- Product Information: Self-Generating Steam Jacketed Counter Tilting
- Specifications
- Safety Precautions
- Installation and Operation
- Service Connections
- Introduction
- Installation
- Operating Instructions
- Cleaning
- Troubleshooting
- Safety Valve Maintenance and Testing
- IDENTIFICATION
- 2400, 215 – 2ND STREET S.W.
- HAZARDS IDENTIFICATION
- COMPOSITION/INFORMATION ON INGREDIENTS
- FIRST AID MEASURES
- FIREFIGHTING MEASURES
- ACCIDENTAL RELEASE MEASURES
- HANDLING AND STORAGE
- EXPOSURE CONTROLS/PERSONAL PROTECTION
- PHYSICAL AND CHEMICAL PROPERTIES
- STABILITY AND REACTIVITY
- TOXICOLOGICAL INFORMATION
- ECOLOGICAL INFORMATION
- DISPOSAL CONSIDERATIONS
- TRANSPORT INFORMATION
- REGULATORY INFORMATION
- OTHER INFORMATION
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CROWN EC-6TW-L Self Generating Steam Jacketed Counter Tilting Kettle
Product Information: Self-Generating Steam Jacketed Counter Tilting
Kettle
The Self-Generating Steam Jacketed Counter Tilting Kettle is a commercial kitchen equipment manufactured by Crown Food Service Equipment, a Middleby Company. The product comes in three different models: EC-6TW-L, EC-10TW-L, and EC-12TW-L. This kettle is designed to generate steam to cook food items with ease.
Specifications
- Model: EC-6TW-L
- Serial #: ___
- Date Purchased: _____
- Manufacturer: Crown Food Service Equipment
- Power Source: Self-Generating Steam
- Tilting Function: Yes
- Capacity: 6 Gallons
Safety Precautions
Before installing and operating the Self-Generating Steam Jacketed Counter Tilting Kettle, it is important to follow the safety precautions mentioned in the manual. The symbols found throughout the manual alert you to potentially dangerous conditions to the operator, service personnel, or to the equipment. The following are the symbols used in the manual:
- DANGER: This symbol warns of immediate hazards that will result in severe injury or death.
- WARNING: This symbol refers to a potential hazard or unsafe practice that could result in injury or death.
- CAUTION: This symbol refers to a potential hazard or unsafe practice that could result in injury, product damage, or property damage.
- NOTICE: This symbol refers to information that needs special attention or must be fully understood, even though not dangerous.
Installation and Operation
It is important to read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. Follow the safety precautions mentioned in the manual to avoid any accidents or problems. The following are some important notes for installation and operation:
- Ensure that everyone involved in the operation of the kettle is fully trained and aware of precautions.
- Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
- Keep the appliance area free and clear from combustibles. Do not obstruct the flow of combustion and ventilation air. Adequate clearances must be maintained for servicing and proper operation.
- Do not attempt to operate this unit in the event of a power failure.
- Contact the factory, the factory representative, or local service company to perform maintenance and repairs.
- This product is intended for commercial use only. NOT FOR HOUSEHOLD USE.
- This manual should be retained for future reference.
It is recommended that you read the manual thoroughly and follow all instructions carefully to ensure proper installation and operation of the Self-Generating Steam Jacketed Counter Tilting Kettle.
WARNING
Improper installation, adjustment, alteration, service or maintenance can
cause property damage, injury or death. Read the installation, operating and
maintenance instructions thoroughly before installing or servicing this
equipment.
CROWN FOOD SERVICE EQUIPMENT 70 Oakdale Road, Downsview (Toronto)
Ontario, Canada, M3N 1V9
Telephone: 919-762-1000
www.crownsteamgroup.com
SAFETY PRECAUTIONS
Before installing and operating this equipment, be sure everyone involved
in its operation is fully trained and aware of precautions. Accidents and
problems can be caused by failure to follow fundamental rules and precautions.
The following symbols, found throughout this manual, alert you to potentially
dangerous conditions to the operator, service personnel, or to the equipment.
-
DANGER
This symbol warns of immediate hazards that will result in severe injury or death. -
WARNING
This symbol refers to a potential hazard or unsafe practice that could result in injury or death. -
CAUTION
This symbol refers to a potential hazard or unsafe practice that could result in injury, product damage, or property damage. -
NOTICE
This symbol refers to information that needs special attention or must be fully understood, even though not dangerous.
IMPORTANT NOTES FOR INSTALLATION AND OPERATION
WARNING
- This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
- Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment.
FOR YOUR SAFETY:
Do not store or use gasoline or other flammable vapors or liquid s in the
vicinity of this or any other appliance.
NOTICE
- Keep the appliance area free and clear from combustibles.
- Do not obstruct the flow of combustion and ventilation air.
- Adequate clearances must be maintained for servicing and proper operation.
NOTICE
- Do not attempt to operate this unit in the event of a power failure.
- Contact the factory, the factory representative or local service company to perform maintenance and repairs.
- This product is intended for commercial use only. NOT FOR HOUSEHOLD USE.
- This manual should be retained for future reference.
It is recommended that this manual be read thoroughly and that all instructions be followed carefully.
Service Connections
As continued product improvement is a policy of Crown, specifications are subject to change without notice.
Introduction
Description
Models EC-6TW-L (6 gallon capacity) and EC-10TW-L (10 gallon capacity) and EC-
12TW-L (12 gallon capacity) electrically powered, self-contained, countertop,
tilting kettles. Each model has a jacket of double-wall construction forming a
sealed reservoir around the lower two-thirds of the kettle. The reservoir is
charged with distilled water. Kettles are equipped with a removable electric
heating element and controls, including a low water cutoff device for
protection of the heating element. All models are of identical construction,
except for kettle size and element heating capacity.
Basic Function
Self-contained kettles operate by generating steam in the kettle reservoir.
The sequence of operation is as follows:
-
Operator turns the power switch to the ON position and sets the temperature control dial to the desired temperature setting.
-
Control circuit is normally completed to the temperature controller if the following conditions exist:
a) Water level in the kettle reservoir is adequate to prevent circuit interruption by the low water cut-off device. An activated cut-off is indicated by the amber low water light turning on, and the heating element shutoff.
b) Kettle is in vertical position with circuit completed through the tilt interlock switch. -
Thermostat control contacts close to energize contactor coils.
-
Power is supplied to the elements through closed power contactors.
-
As the temperature of water rises in the kettle reservoir, increase in steam pressure is indicated on the pressure gauge.
-
When the temperature of steam in the reservoir reaches the setting of the temperature control dial, the temperature controller opens to break the contacts and shuts off the heating element. On/off cycles will occur as required to maintain temperature setting.
Installation
UNPACKING
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
Immediately after unpacking the steamer, check for possible shipping damage.
If the steamer is found to be damaged, save the packaging material and contact
the carrier within 15 days of delivery.
Installation Instructions
-
The kettle must be installed in accordance with:
a) State and/or local codes.
b) In the USA, the National Electrical Code, ANSI/NFPA-70 (latest edition). In Canada, the Canadian Electrical Code, Part 1, CSA Standard C22.1 (latest edition). -
Position appliance on counter allowing sufficient rear clearance from wall to tilt freely and completely without obstruction.
-
Mark four corner locations of appliance base.
-
Remove appliance from counter and locate position of 4 holes as per Figure 1. Drill four 7/16” diameter holes.
-
Apply a continuous bead of Silastic or other equivalent sealant along the complete perimeter edge of the appliance base.
-
Use 5/16-18 Hex Cap Screws with suitable flat washers to bolt down. Screw length must be 1-1/4 long plus counter top thickness.
-
Wipe off excess sealant.
-
A Control Box with power supply equivalent to Electrical Rating of appliance should be located conveniently nearby.
WARNING
ELECTRICAL GROUNDING INSTRUCTIONS
Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.
WARNING
Disconnect electrical power supply and place a tag at the disconnect switch to indicate you are on the circuit. -
A waterproof electrical connection from power supply to console housing must be provided.
-
Ground appliance to terminal provided inside console housing.
-
Turn power ON and check for proper operation.
Operating Instructions
-
Ensure that the external electrical shut-off to the kettle is on.
-
Check pressure gauge for correct cold kettle reading. Reading should be in the green vacuum zone. If reading is not in the vacuum zone, follow VENTING INSTRUCTION prior to using the kettle.
-
Place power switch in ON position.
-
Preheat the kettle by placing thermostat knob at maximum and wait until TEMPERATURE light goes off.
NOTICE
Preheating should not be used when cooking milk and egg food products which adhere to hot cooking surfaces.
These foods should be placed into kettle before heating is begun. -
Add food to be cooked into the kettle.
-
Place thermostat knob at required temperature setting with a temperature range from roughly 165 °F to 289 °F (74 °C to 143 °C, jacket temperature.)
-
When cooking is finished set thermostat knob and power switch to the OFF position.
-
Pour finished product from kettle using tilt handle. Be careful to avoid splashing.
-
Add water to kettle for cleaning purposes.
-
Wash kettle thoroughly. See CLEANING procedure.
Tilting Instructions
Your kettle has the standard “Clean Lock” feature and may not be tilted
without disengaging the tilt knob located on the console at the top right.
This feature locks the kettle in the upright position and also allows the
operator to lock the kettle at 105 degrees for ease of cleaning. To tilt the
kettle the full distance, the tilt lock knob must be disengaged from the
cleaning position by pulling out the tilt lock knob and tilting the kettle
forward the full distance. Follow these steps to tilt kettle:
- Pull out the tilt knob near top right of console.
- Using kettle tilt handle pull kettle forward to desired angle of pour or until kettle locks at 105 degrees. The tilt knob can be released after the kettle has been tilted approximately 10°.
- Kettle will lock in position at 105 degrees and may be tilted further by pulling the tilt lock knob a second time allowing the kettle to tilt the full distance.
- To return the kettle to the upright position, pull out the tilt lock knob and tilt the kettle upward until it locks in the upright position. The kettle should not move in either direction once in the upright position.
Cleaning
WARNING
- Disconnect the power supply to the appliance before cleaning or servicing.
- Never spray water into electric controls or components!
CAUTION
- The equipment and its parts are hot. Use care when operating, cleaning and servicing.
- Do not use cleaning agents that are corrosive.
The kettle interior and exterior should be thoroughly washed after each use in preparation of a different food.
-
Add water and mild detergent to the kettle immediately after use.
-
Scrub kettle interior with nylon brush.
NOTICE
Never scrape the inside of the kettle with metal tools, steel scouring pads, or abrasive cleaners. Scratches will result which will spoil the kettle’s general appearance and make it harder to clean and maintain a sanitary condition -
Loosen food which is stuck to kettle by allowing it to soak at a low temperature setting.
-
Rinse with clear water and dry.
WARNING
Do not hose down appliance under any condition. Failure to comply will void warranty. -
Wipe down exterior, rinse and dry.
WARNING
It is NOT RECOMMENDED to use cleaning agents that are corrosive.
Use of cleaning agents that contain chloride, acids or salts are corrosive and
may cause pitting and corrosion when used over a period of time; this will
reduce the life of the appliance.
Should pitting or corrosion occur this is not covered by warranty.
Follow the recommended cleaning instructions. Use a mild detergent, warm water
and rinse thoroughly.
Troubleshooting
General Maintenance
No general maintenance is required other than adhering to the Cleaning
Procedure Instructions.
Low Water Level
Proper water level must be maintained within the jacket for the kettle to
operate. Depletion of water may occur from excessive opening of, or leakage
through the safety relief valve.
If water is below required operating level, either initially at start-up or
during use, the kettle will automatically shut off, and the LOW WATER signal
light will come on.
In order for the kettle to operate, the following procedure must be
followed:
- Trip the safety relief valve lever to relieve all pressure from the kettle jacket.
- At exterior rear of kettle jacket remove nut from Air Vent.
- Insert funnel into Air Vent opening and slowly add the indicated amount of distilled water for:
Model| Amount of Distilled Watter
---|---
EC-6TW-L| Add 50 oz. (1.5 litres)
EC-10TW-L and EC-12TW-L| Add 100 oz. (3 litres) - Replace Air Vent nut.
- Follow Air Venting Instructions below.
- Continue normal Operating Procedure of kettle.
Venting Instruction
Check pressure gauge when kettle is cold. Gauge should be in the green vacuum
zone. If not, air is present which must be vented (removed) for proper
heating. Use the following procedures to vent air.
- With an empty kettle, place power switch to the ON position.
- Set temperature control thermostat to maximum. Heat kettle until heat indicator light goes off.
- Using a 7/16” wrench, open bleed vent one full turn for 10 seconds and then close.
- Cool kettle. Check for proper vacuum in the green vacuum zone. If reading is not low enough, repeat entire procedure, steps 1 to 3.
Safety Valve Maintenance and Testing
CAUTION
- Under normal operating conditions a “try lever test” should be performed every two months. Under severe service conditions, or if corrosion and/or deposits are noticed within the valve body, testing must be performed more often. A “try lever test” should also be performed at the end of any non-service period.
- Hot, high pressure fluid may be discharged from body drain and vent during “try lever” test. Care must be taken to avoid any bodily contact.
- High sound levels may be experienced during “try lever” test. Wear proper safety equipment and exercise extreme care! Test at, or near, half of the operating pressure by holding the test lever fully open for at least two seconds to flush the valve seat free of sediment and debris. Then release lever and permit the valve to snap shut.
- If lift lever does not activate, or there is no evidence of discharge, turn off equipment immediately and contact a licensed contractor or qualified service personnel.
Material Safety Data Sheets
Appendix ‘A’ ****
SAFETY DATA SHEET DOW CHEMICAL CANADA ULC
Product name: DOWFROSTTM HD Heat Transfer Fluid, Dyed
Issue Date: 01/19/2017 Print Date : 01/23/2017
DOW CHEMICA CANADA ULC encourages and expects you to read and understand the
entire (M)SDS, as there is important information throughout the document. We
expect you to follow the precautions identified in this document unless your
use conditions would necessitate other appropriate methods or actions.
IDENTIFICATION
Product name: DOWFROSTTM HD Heat Transfer Fluid, Dyed
Recommended use of the chemical and restrictions on use Identified uses:
Intended as a heat transfer fluid for closed-loop systems. We recommend that
you use this product in a manner consistent with the listed use. If your
intended use is not consistent with the stated use, please contact your sales
or technical service representative.
COMPANY IDENTIFICATION
DOW CHEMICAL CANADA ULC
2400, 215 – 2ND STREET S.W.
CALGARY AB T2P 1
CANADA
Information Number : 800-258-2436
SDSQuestion@dow.com
EMERGENCY TELEPHONE NUMBER
24-Hour Emergency Contact:
1-888-226-8832
Local ETErgency Contact:
613-996-6666
HAZARDS IDENTIFICATION
Hazard classification
This product is not hazardous under the criteria of the Hazardous Products
Regulation (HPR) as implemented under the Workplace Hazardous Materials
Information System (WHMIS 2015).
Other hazards
No data available
COMPOSITION/INFORMATION ON INGREDIENTS
This product is a mixture.
FIRST AID MEASURES
Description of first aid measures
- General advice: If potential for exposure exists refer to Section 8 for specific persona protective equipment.
- Inhalation : Move person to fresh air; if effects occur, consult a physician.
- Skin contact: Wash Off with plenty Of water.
- Eye contact: Flush eyes thoroughly with water for several minutes. Remove contact lenses after the initial 1-2 minutes and continue flushing for several additional minutes. If effects occur, consult a physician, preferably an ophtha mologist.
- Ingestion: NO emergency medical treatment necessary.
- Most important symptoms and effects, both acute and delayed: Aside from the information found under Description of first aid measures (above) and Indication of immediate medical attention and special treatment needed (below), any additional important symptoms and effects are described in Section 11: Toxicology Information,
- Indication of any immediate medical attention and special treatment needed Notes to physician : No specific antidote. Treatment of exposure should be directed at the control of symptoms and the clinical condition of the patient.
FIREFIGHTING MEASURES
- Suitable extinguishing media: Water fog or fine spray. Dry chemical fire extinguishers. Carbon dioxide fire extinguishers. Foam. Alcohol resistant foams (ATC type) are preferred. General purpose synthetic foams (including AFFF) or protein foams may function, but will be less effective.
- Unsuitable extinguishing media : Do not use direct water stream. May spread fire.
- Special hazards arising from the substance or mixture Hazardous combustion products: During a fire, smoke may contain the original material in addition to combustion products of varying composition which may be toxic and/or irritating. Combustion products may include and are not limited to: Carbon monoxide. Carbon dioxide.
- Unusual Fire and Explosion Hazards : Container may rupture from gas generation in a fire situation. Violent steam generation or eruption may occur upon application Of direct water stream to hot liquids.
Advice for firefighters
- Fire Fighting Procedures : Keep people away. Isolate fire and deny unnecessary entry. Use water spray to cool fire exposed containers and fire affected zone until fire is out and danger of reignition has passed. Fight fire from protected location or safe distance. Consider the use Of unmanned hose holders or monitor nozzles. Immediately withdraw all personnel from the area in case of rising sound from venting safety device or discoloration of the container. Burning liquids may be extinguished by dilution with water. Do not use direct water stream. May spread fire. Move container from fire area if this is possible without hazard. Burning liquids may be moved by flushing with water to protect personnel and minimize property damage.
- Special protective equipment for firefighters: Wear positive-pressure self-contained breathing apparatus (SCBA) and protective fire fighting clothing (includes fire fighting helmet, coat, trousers, boots, and gloves). If protective equipment is not available or not used, fight fire from a protected location or safe distance.
ACCIDENTAL RELEASE MEASURES
- Personal precautions, and emergency procedures: Keep unnecessary and unprotected personnel from entering the area Use appropriate safety equipment. For additional information, refer to Section 8, Exp)sure Controls and Personal Protection.
- Environmental precautions: Prevent from entering into soil, ditches, sewers, waterways and/or groundwater. See 12, Ecologica Information.
- Methods and materials for containment and cleaning up: Small spills: Absorb with materials such as: Cat litter. Sawdust. Vermiculite. Zorb-all@. Collect in suitable and progErly latEled containers. Large spills: Dike area to contain spill. See Section 13, Disgsal Considerations, for additional information.
HANDLING AND STORAGE
- Precautions for safe handling: Conditions for safe storage: DO not store in: Galvanized steel, Opened or unlabeled containers. Store in the following material(s): Carbon steel. Stainless steel. Store in original unopened container. See Section 10 for more specific information. Additional storage and handling information on this product may be obtained by calling your sales or customer service contact.
EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure limits are listed below, if they exist.
Consult local authorities for recommended exposure limits.
Exposure controls
Engineering controls: Use local exhaust ventilation, or other engineering
controls to maintain airborne levels below exposure limit requirements or
guidelines. If there are no applicable exposure limit requirements or
guidelines, general ventilation should be sufficient for most operations.
Local exhaust ventilation may be necessary for some operations.
Individual protection measures
- Eye/face protection: Use safety glasses (with side shields).
- Skin protection
- Hand protection: Use gloves chemically resistant to this material when prolonged or frequently repeated contact could occur. Examples of preferred glove barrier materials include: Butyl rubber. Natural rubber (“latex”). Neoprene. Nitrile/butadiene rubber (“nitrile” or “NBR”). Polyethylene. Ethyl vinyl alcohol laminate (“EVAL’). Polyvinyl alcohol (“PVA”). Polyvinyl chloride (‘PVC’ or ‘Vinyl”). NOTICE: The selection of a specific glove for a particular application and duration of use in a workplace should also take into account all relevant workplace factors such as, but not limited to: Other chemicals which may be handled, physical requirements (cut/puncture protection, dexterity, thermal protection), potential body reactions to glove materials, as well as the instructions/specifications provided by the glove supplier.
- Other protection: Wear clean, body-covering clothing
- Respiratory protection: Respiratory protection should be worn when there is a potential to exceed the exposure limit requirements or guidelines. If there are no applicable exposure limit requirements or guidelines, wear respiratory protection when adverse effects, such as respiratory irritation or discomfort have been experienced, or where indicated by your risk assessment process. In misty atmospheres, use an approved particulate respirator. The following should be effective types Of air-purifying respirators: Organic vapor cartridge with a particulate pre-filter.
PHYSICAL AND CHEMICAL PROPERTIES
Appearance
- Physical state Liquid
- Color Yellow to green
- Odor Characteristic
- Odor Threshold No test data available
- pH 9.5 50% Literature
- Melting point]range Not applicable to liquids
- Freezing point supercools
- Boiling point (760 mmHg) 152 oc Literature
- Flash point closed cup 104 oc Pensky-Martens Closed Cup ASTM D 93 Propylene glycol., (based on major component)
- Evaporation Rate (Butyl Acetate < O, 5 Estimated.
- Flammability (solid, gas) Not applicable to liquids
- Lower explosion limit 2.6 % VOI Literature Propylene glycol.
- Upper explosion limit 12.5 % VOI Literature Propylene glycol.
- Vapor Pressure 2.2 mmHg Literature
- Relative Vapor Density (air= 1) >1 .0 Literature
- Relative Density (water = 1) 1.06 at 20 °c / 20 °c Literature
- Water solubility 100 % Literature
- Partition coefficient: noctanol/ water No data available
- Auto-ignition temperature 371 °c Literature Propylene glycol.
- Decomposition temperature No test data available
- Kinematic Viscosity 43.4 est at 20 °c Literature
- Explosive properties No data available
- Oxidizing properties No data available
- Molecular weight No data available
NOTE: The physical data presented above are typical values and should not be construed as a specification.
STABILITY AND REACTIVITY
- Reactivity: No data available
- Chemical stability: Stable under recommended storage conditions. See Storage, Section 7. Hygroscopic
- Possibility of hazardous reactions: Polymerization will not occur.
- Conditions to avoid: Exposure to elevated temperatures can cause product to decompose. Generation of gas during decomposition can cause pressure in closed systems. Avoid direct sunlight or ultraviolet sources.
- Incompatible materials: Avoid contact with: Strong acids. Strong bases. Strong oxidizers.
- Hazardous decomposition products: Decomposition products depend upon temperature, air supply and the presence of other materials. Decomposition products can include and are not limited to: Aldehydes. Alcohols. Ethers. Organic acids.
TOXICOLOGICAL INFORMATION
Toxicological information appears in this section when such data is available.
Acute toxicity
-
Acute oral toxicity
Very low toxicity if swallowed Harmful effects not anticipated from swallowing small amounts.
For the major component(s): Propylene glycol. LD50, Rat, > 20,000 mg/kg -
Acute dermal toxicity
Prolonged skin contact is unlikely to result in absorption of harmful amounts.
For the major component(s): Propylene glycol.
LD50, Rabbit, > 20,000 mg/kg -
Acute inhalation toxicity
At room temperature, exposure to vapor is minimal due to low volatility. Mist may cause irritation of upper respiratory tract (nose and throat). -
For the major component(s):
LC50, Rat, 4 Hour, vapour, 6.15 mg/I No deaths occurred following exposure to a saturated atmosphere.
Skin corrosion/irritation
- Prolonged contact is essentially nonirritating to skin.
- Repeated contact may cause flaking and softening of skin.
Serious eye damage/eye irritation
- May cause slight temporary eye irritation.
- Corneal injury is unlikely.
Sensitization
- For the major component(s):
- Did not cause allergic skin reactions when tested in humans.
For respiratory sensitization :
- No relevant data found.
Specific Target Organ Systemic Toxicity (Single Exposure)
- Evaluation of available data suggests that this material is not an STOT-SE toxicant.
Specific Target Organ Systemic Toxicity (Repeated Exposure)
- In rare cases, repeated excessive exposure to propylene glycol may cause central nervous system effects.
Carcinogenicity
- Similar formulations did not cause cancer in laboratory animals.
Teratogenicity
- For the major component(s): Did not cause birth defects or any other fetal effects in laboratory animals.
Reproductive toxicity
- For the major component(s): In animal studies, did not interfere with reproduction. In animal studies, did not interfere with fertility.
Mutagenicity
- In vitro genetic toxicity studies were negative. For the major component(s) : Animal genetic toxicity studies were negative.
Aspiration Hazard
- Based on physical properties, not likely to be an aspiration hazard.
ECOLOGICAL INFORMATION
Ecotoxicological information appears in this section when such data is
available.
Toxicity
-
Propylene glycol
-
Acute toxicity to fish
Material is practically non-toxic to aquatic organisms on an acute basis (LC50/EC50/EL50/LL50 >100 mg/Lin the most sensitive species tested). LC50, Oncorhynchus mykiss (rainbow trout), static test, 96 Hour, 40,613 mg/I, OECD Test Guideline 203 -
Acute toxicity to aquatic invertebrates
LC50, Ceriodaphnia dubia (water flea) , static test, 48 Hour, 18,340 mg/I, OECD Test Guideline 202 -
Acute toxicity to algae/aquatic plants
ErC50, Pseudokirchneriella subcapitata (green algae), 96 Hour, Growth rate inhibition, 19,000 mg/I, OECD Test Guideline 201 -
Toxicity to bacteria
NOEC, Pseudomonas putida, 18 Hour, > 20,000 mg/I -
Chronic toxicity to aquatic invertebrates
NOEC, Ceriodaphnia dubia (water flea) , semi-static test, 7 d, number of offspring, 13,020 mg/I
-
-
Dipotassium hydrogen phosphate
Acute toxicity to fish
Material is practically non-toxic to aquatic organisms on an acute basis (LC50/EC50/EL50/LL50 >100 mg/L in the most sensitive species tested). LC50, Leuciscus idus (Golden orfe), static test, 48 Hour, > 900 mg/I, Method Not Specified.
Persistence and degradability
-
Propylene glycol
-
Biodegradability: Material is readily biodegradable. Passes OECD test(s) for ready biodegradability. Biodegradation may occur under anaerobic conditions (in the absence of oxygen).
10-day Window : Pass -
Biodegradation: 81 %
-
Exposure time : 28 d
-
Method: OECD Test Guideline 301F or Equivalent
10-day Window : Not applicable -
Biodegradation: 96 %
-
Exposure time: 64 d
-
Method: OECD Test Guideline 306 or Equivalent
-
Theoretical Oxygen Demand : 1.68 mg/mg
-
Chemical Oxygen Demand : 1.53 mg/mg
-
Biological oxygen demand (BOD)
Photodegradation
Atmospheric half-life: 10 Hour
Method: Estimated.
Dipotassium hydrogen phosphate
Biodegradability: Biodegradation is not applicable.
Bioaccumulative potential
Propylene glycol
- Bioaccumulation: Bioconcentration potential is low (BCF < 100 or Log Pow < 3).
- Partition coefficient: n-octanol/water(log Pow): -1. 07 Measured
- Bioconcentration factor (BCF): 0.09 Estimated.
Dipotassium hydrogen phosphate
- Bioaccumulation: No bioconcentration is expected because of the relatively high water solubility.
Mobility in soil
Propylene glycol
- Given its very low Henry’s constant, volatilization from natural bodies of water or moist soil is not expected to be an important fate process.
Potential for mobility in soil is very high (Koc between O and 50).
Partition coefficient (Koc): < 1 Estimated.
Dipotassium hydrogen phosphate
No relevant data found.
DISPOSAL CONSIDERATIONS
Disposal methods : DO NOT DUMP INTO ANY SEWERS, ON THE GROUND, OR INTO ANY BODY OF WATER. All disposal practices must be in compliance with all Federal, State/Provincial and local laws and regulations. Regulations may vary in different locations. Waste characterizations and compliance with applicable laws are the responsibility solely of the waste generator. AS YOUR SUPPLIER, WE HAVE NO CONTROL OVER THE MANAGEMENT PRACTICES OR MANUFACTURING PROCESSES OF PARTIES HANDLING OR USING THIS MATERIAL. THE INFORMATION PRESENTED HERE PERTAINS ONLY TO THE PRODUCT AS SHIPPED IN ITS INTENDED CONDITION AS DESCRIBED IN MSDS SECTION: Composition Information. FOR UNUSED & UNCONTAMINATED PRODUCT, the preferred options include sending to a licensed, permitted: Recycler. Reclaimer. Incinerator or other thermal destruction device.
TRANSPORT INFORMATION
-
TDG
Not regulated for transport -
Classification for SEA transport (IMO-IMDG):
Not regulated for transport
Transport in bulk Consult IMO regulations before transporting ocean bulk
according to Annex I or II
of MARPOL 73/78 and the
IBC or IGC Code -
Classification for AIR transport (IATA/ICAO):
Not regulated for transport
This information is not intended to convey all specific regulatory or operational requirements/information relating to this product. Transportation classifications may vary by container volume and may be influenced by regional or country variations in regulations. Additional transportation system information can be obtained through an authorized sales or customer service representative. It is the responsibility of the transporting organization to follow all applicable laws, regulations and rules relating to the transportation of the material.
REGULATORY INFORMATION
Canadian Domestic Substances List (DSL)
This product contains at least one substance which is not listed on the
Canadian Domestic Substances List (DSL).
OTHER INFORMATION
Hazard Rating System
NFPA
Revision
Identification Number : 101199333 / A208 / Issue Date: 01/19/2017 /
Version: 7.0
Most recent revision(s) are noted by the bold, double bars in left-hand margin
throughout this document.
Legend Information Source and References
This SOS is prepared by Product Regulatory Services and Hazard Communications
Groups from information supplied by internal references within our company.
DOW CHEMICAL CANADA ULC urges each customer or recipient of this (M)SDS to
study it carefully and consult appropriate expertise, as necessary or
appropriate, to become aware of and understand the data contained in this
(M)SDS and any hazards associated with the product The information herein is
provided in good faith and believed to be accurate as of the effective date
shown above. However, no warranty, express or implied, is given Regulatory
requirements are subject to change and may differ between various locations.
It is the buyer’s/user’s responsibility to ensure that his activities comply
with all federal, state, provincial or local laws. The information presented
here pertains only to the product as shipped. Since conditions for use of the
product are not under the control of the manufacturer, it is the
buyer’s/user’s duty to determine the conditions necessary for the safe use of
this product Due to the proliferation of sources for information such as
manufacturerspecific (M)SDSs, we are not and cannot be responsible for (M)SDSs
obtained from any source other than ourselves. If you have obtained an (M)SDS
from another source or if you are not sure that the (M)SDS you have is
current, please contact us for the most current version
EC-6TW-L, EC-10TW-L and EC-12TW-L
SELF-GENERATING
STEAM JACKETED
COUNTER TILTING KETTLES
A product with the Crown name incorporates the best in durability and low maintenance. We all recognize, however, that replacement parts and occasional professional service may be necessary to extend the useful life of this appliance. When service is needed, contact a Crown Authorized Service Agency, or your dealer. To avoid confusion, always refer to the model number, serial number, and type of your appliance
CROWN FOOD SERVICE EQUIPMENT
A Middleby Company
70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9
Telephone: 919-762-1000
www.crownsteamgroup.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>