COLUMBIA VAC KLC9050 Portable Air Conditioner User Manual

June 4, 2024
COLUMBIA VAC

COLUMBIA VAC KLC9050 Portable Air Conditioner

ATTENTION:

  • Appliance is filed with flammable gas R290.
  • Before using the appliance, read the mannual.
  • Before installing the appliance, read  the installation mannual.
  • Any repairs you need, contact the nearest authorized Service Centre and ctrictly follow manufacturer’s instruction only.
    The figures in this Instructions Manual might slightly differ from those actually displayed on the device. Note the actual figures.

SAFETY INSTRUCTIONS

PRECAUTIONS

  • Carefully read the Instructions Manual, and familiarise yourself with the warnings on the device before installing and commissioning. The Instructions Manual contains the correct installation and operation principles of the air conditioner. Non-observance of the principles can lead to voiding the warranty.
  • This device can be used by children of at least 8 years of age; by persons with reduced physical and mental abilities; and by persons with no experience or knowledge of the equipment, if supervised or instructed on its safe use so that the risks associated with it are understood. Children should not play with the device. Unattended children should not be allowed to perform the cleaning and maintenance of the device.
  • Unintended use of the air conditioner can lead to voiding the warranty.
  • The device should not be operated by persons who have no knowledge of the equipment or have not read the Instructions Manual. This particularly applies to children.
  • The device is intended for use only with R-290 (propane) gas as the refrigerant. R290 is a gaseous coolant which meets EU Environmental Directives.

Information on equipment using R290 gaseous refrigerant

  • Read all warnings carefully.
  • Do not pour the refrigerant into the atmosphere.
  • R-290 (propane) is flammable and heavier than air.
  • It first accumulates at the lower levels, but can be distributed by air movement (e.g., by fans).
  • If propane is present, or its presence is even just suspected, it is forbidden to allow unqualified personnel to try to find the cause.
  • The R-290 (propane) used in the device is odourless.
  • No odour does not mean that no gas is escaping.
  • In the event of leak detection, evacuate all persons from the room, ventilate the room, and contact the local fire service in order to report the propane leak.
  • Do not allow anyone into the room until a qualified service technician arrives and affirms that entering the room is safe.
  • Do not use tools other than those recommended by the manufacturer during defrosting and cleaning.
  • The device should be placed in the area free of fixed ignition sources (e.g., an open fire, or operating gas or electric equipment).
  • The device‘s components are specially designed for the use of propane, and have no ignition or sparking properties. Replace the components only with identical spare parts.
  • Do not allow the housing to be punctured. Do not burn the device.
  • The unit must be installed, operated, and stored in a room bigger than 9 m2.
  • If the unit is installed, operated, or stored in a room without ventilation, measures should be implemented preventing the accumulation of leaking coolant, the causing of a fire, or an explosion hazard due to the ignition of the coolant caused by an electric heater, stove, or other ignition sources.
  •  Store the device in a way which avoids mechanical damage.
  • Persons operating or modifying the cooling circuit must hold the appropriate authorisations from an accredited organisation to guarantee the professional handling of the refrigerant, which must be confirmed by reputable industry organisations.
  • All repairs should be performed according to the manufacturer’s recommendations. Maintenance and repairs requiring the employment of experts in other fields should be carried out under the supervision of a person authorised to use flammable refrigerants.
  • This device is intended for home use only, as described in this Instructions Manual. Do not use the device for purposes other than those specified in this Instructions Manual.
  • Installing the air conditioner does not require special knowledge, and may be performed by the user in accordance with the guidelines and figures contained in the Instructions Manual. Improper installation can result in water leakage, or electrocution, or irreparable damage to the unit. Eldom Sp. z o. o. shall not be liable for any potential losses due to the improper use of the device.
  • The unit must be installed in accordance with the national regulations for electrical systems. Before connecting the device to the mains, check that the mains current parameters (voltage) correspond to the parameters indicated on the device. The device’s outlet plug should be completely plugged into the power socket. Do not use extension cords or multi-outlet adapters to connect the device’s power cord. Remove the outlet plug from the socket if the device is not to be used for an extended period. If the unit has not been used for a long time, check that the air inlets and outlets are unobstructed before starting the device.
  • Connect the device only to an earthed power socket.
  • Keep the device at least 50 cm away from flammable material and substances (e.g., alcohol, etc) or pressurised containers (e.g., aerosols).
  • The power cord and plug are intended for the final disconnection of the device from the power supply, which is why they must be easily accessible at all times.
  • Switch off the air conditioner and disconnect it from the power supply during a storm.
  • Do not insert hands or objects into the air outlets.
  • Do not put any objects on the device.
  • Do not step or sit on the device.
  • Do not insert fingers or other objects into the air outlet.
  • Do not touch the air inlet or the aluminium fins of the unit.
  • Before cleaning, repair, maintenance, or inspection, switch the air conditioner off and disconnect it from the power supply.
  • Clean the device with a dry, soft, cloth. If the unit’s housing is heavily soiled, you may use a cloth soaked in a household cleaning agent. Do not wipe or clean the air conditioner with chemical solvents such as petrol and alcohol.
  • Do not immerse or expose this unit to precipitation, moisture, or other liquids.
  • Do not operate with wet hands. Avoid water spillages on the unit.
  • Do not immerse or expose this unit to precipitation, moisture, or other liquids.
  •  Do not leave the device unattended when it is running. Do not tilt or overturn the device.
  • Place and operate the unit away from splashes of water or oil.
  • If during the device’s operation, the user detects any irregularities, such as a strange odour or sound, smoke, steam, fire, over heating of housing or outlet plug, fuse failure, or interruptions to the operation of other devices, immediately switch the device off, disconnect from the power supply, and contact an authorised service centre.
  • Do not use if the power cord is damaged, or if the unit has been dropped or otherwise damaged. The repair of the device should be entrusted to an authorised service centre; see information on the warranty card and on the website www.eldom.eu.
  • All modifications, and the use of spare parts or device elements other than the original ones, are prohibited, and can pose a hazard to the safety of use.
  • Under the risk of voiding the warranty, the user may not perform any repairs, modifications, or disassembly, of the device’s housing.
  • There are no user-serviceable parts inside the unit.
  • All modifications, and the use of spare parts or device elements other than the original ones, are prohibited, and can pose a hazard to the safety of use.

ATTENTION

  • Persons operating or modifying the cooling circuit must hold  the appropriate authorisations from an accredited organisation to  guarantee the professional handling of the refrigerant, which must be confirmed by reputable industry organisations.
  • All repairs should be performed according to the manufacturer’s  recommendations. Maintenance and repairs requiring the employment  of experts in other fields should be carried out under the supervision of  a person authorised to use flammable refrigerants.
  • If there is any lack of understanding of any information, or help is  needed, contact the dealer’s service centre
  • BEFORE THE FIRST USE OF THE DEVICE, MAKE SURE THAT IT HAS BEEN PLACED IN THE VERTICAL POSITION FOR 24 HOURS; OTHERWISE, THE DEHUMIDIFIER COMPRESSOR CAN BE DAMAGED.

SAFETY WARNINGS FOR SERVICING
Observe all these warnings when performing the following works while servicing the dehumidifier with R290.

  1. Area inspections
    Before performing any works on circuits containing flammable refrigerants, it is necessary to perform safety inspections of the area to make sure that the risk of ignition is minimised. When repairing the cooling system, the following precautions must be implemented before working on the system.

  2. Working procedure
    Tasks should be carried out under the controlled procedure so that the risk of the presence of flammable gas or vapours is minimised when work is being carried out.

  3. General workplace
    All maintenance personnel and others working in the place should be instructed in the nature of the work. Avoid working indoors. The area around the workplace must be isolated. Make sure that conditions in the area have been secured by control flammable materials.

  4. Refrigerant-presence inspection
    Before and during performing work, check the area with a suitable refrigerant detector to ensure that the technician is aware of potentially flammable atmospheres. Make sure that the leak-detection equipment used is suitable for use with flammable refrigerants, i.e., does not cause sparking, is properly sealed, and is intrinsically safe.

  5. Fire-extinguishing accessibility
    If any hot operations are to be carried out on the cooling equipment or any associated parts, suitable fire-extinguishing equipment should be available. Dry powder or CO2 fire extinguisher should be placed adjacent to the charging area.

  6. No ignition sources
    No persons performing work on cooling systems, which consists of uncovering pipes containing flammable refrigerant may use any ignition sources in a manner creating a risk of fire or explosion. All possible sources of ignition, including cigarette smoking, should be kept at a suitable distance from the place of installation, repair, removal, and disposal, during which the flammable refrigerant can be released into the environment. Before starting work, examine the area around the equipment to ensure that there is no fire or ignition hazard. Place “No smoking” signs.

  7. Ventilated area
    Make sure that the area is outside or properly ventilated before performing any repair or maintenance works on the system or hot operations. A certain degree of ventilation should be maintained during the work-performing period. Ventilation should safely disperse the released refrigerant, and preferably release it outside into the atmosphere.

  8. Cooling equipment inspections
    In the event of the replacement of electrical components, they should be appropriate for the purpose, and compliant with the relevant specifications. The manufacturer’s guidelines for maintenance and servicing must be observed at all times. If any doubts, contact the technical department of the manufacturer.
    The following inspections should be performed concerning the systems using flammable refrigerants:

    • The size of the load is compliant with the room size in which components containing refrigerant are installed;
    • Ventilation units and outlets are working properly, and are not clogged up;
    • When using an intermediate cooling circuit, check for the refrigerant;
    • The marking of the device is still visible and legible. Markings and signs which are illegible must be corrected;
    •  Cooling pipes or components should be installed in a place where there is a low likelihood
      of their coming into contact with any substance which can cause corrosion of components containing refrigerant, unless these components are made of materials inherently resistant to corrosion, or adequately protected against corrosion.
  9. Electrical-equipment inspections
    Repairs and maintenance of the electric components include preliminary safety inspections and component-control procedures. In the instance of a fault which could risk safety, do not connect the power supply to the circuit until it has been satisfactorily rectified. If the fault cannot be rectified immediately, but further action is necessary, an appropriate temporary solution must be implemented. This should be reported to the device owner so that all parties are informed. Preliminary safety inspections include

    • condenser discharge: should be done in a safe way to avoid the possibility of sparking;
    • no covering of live electrical components or wiring when charging, recovering, or cleaning the system;
    • earthing continuity

SPECIAL RECOMMENDATIONS:

  • Ambient temperature range for the device is 5°C -35°C.
  • Install the portable air dryer on a flat location with a large space, without obstacles. Leave a 30cm minimum space between the unit and the wall.
  • The device must be installed in accordance with national installation regulations.
  • The plug shall be always accessible after its installation.
  • Always place the appliance in a vertical position, in order to maintain the compressor in good working condition.
  • Do not tilt the device in any direction as spilled water can damage the device.
  • Do not use the appliance near gas or other inflammable liquids.
  • Do not block the air outlet and inlet ventilation. Do not place heavy objects on the device.
  • Do not use spray (insecticides, painting) or any other inflammable products near the appliance as the plastic case may be deformed. The unit may sustain electrical damage.

POWER SOURCES

  • The plug has to be well fixed and should not be damaged.
  • Do not plug in the appliance with an adaptor.
  • Plug into the wall socket before switching on the appliance then press on the ON/OFF button.

GENERAL DESCRIPTION

COLUMBIA VAC KLC9050 Portable Air Conditioner-fig2

Front:

1.          Control panel

2.          Top cover

3.          Louvres

4.          Handles

| ****

5.     Front cover

6.     Rear cover

7.     Base

8.     Wheels

---|---
Rear:

9.     Filter I

10.  Water drain – continuous

11.  Warm-air outlet

| ****

12.        Place for the plug

13.        Filter II

14.        Water drain – manual

Additional accessories:

15.       Remote control

16.       Outlet pipe

| ****

17.       Connection adaptor

18.       Mounting panel (2 parts)

INTENDED USE

The KLC9050 air conditioner is designed to improve thermal comfort in living spaces. The air can be cooled or dehumidified with it. It will also work as a standard fan. The device can be controlled from a smartphone by means of the installed application (download from www.eldom.eu)

TIPS

  • In order to reach the target temperature as soon as possible during the cooling process, the doors and windows in the air-conditioned room should be closed, and the use of heat emitting devices should be kept to a minimum.
  • Do not expose yourself to cold air for long periods of time, as this is harmful to your health.

INSTALLATION

  • Choosing the place for installation – drawing 2.

    • The device must be placed vertically on a flat surface, in a dry and spacious place. Leave at least 50 cm of free space round the unit.
    • The unit must be installed in accordance with the national regulations for electrical installations. Before connecting to the mains, make sure that the mains-current (voltage) parameters correspond to those specified on the device.
    • The mains plug of the device should be fully plugged into the mains socket.
    • Do not use extension cords or splitters to connect the mains cable of the device.
    • If the device will not be used for an extended period of time, unplug the power cord from the wall outlet.
    • If the unit has not been used for a long time, check that the air inlets and outlets are not blocked before restarting the unit.
  • Installation of the outlet pipe

    • Attach the connector (17) to one end of the outlet pipe and attach the other end of the pipe to the outlet (11) – drawing 3.
    • The connector (17) can be mounted on the mounting panel (18) and then placed in the window – drawing 4.
    • The length of the panel (18) is adjustable.

COLUMBIA VAC KLC9050 Portable Air Conditioner-fig5

  • Incorrect installation
    • The outlet pipe (16) should not be excessively bent – drawing 5.
    • Improper installation can result in the improper operation of the device.
    • There must be no sharp bends in the outlet pipe (16).
    • The air leaving the unit must flow freely.
      NOTE
      The length of the outlet pipe is designed in accordance with the air conditioner’s specifications. Do not replace the outlet pipe with other hoses, or extend it, as this can cause malfunction of the unit. The maximum length of the straightened outlet pipe is 1500 mm. Use the shortest pipe length possible. It is most recommended to install the outlet pipe horizontally.
A TIMER – used to start and stop the automatic operation of the device
B, O, P fan speed selection (low, high)
C, E buttons for setting the temperature (cooling) and time (TIMER)
D switching the device on/off
F, S, T, W selecting the operating mode **(cooling, dehumidification,

fan)
G| lock
H| operation mode indicator – fan
I| operation mode indicator – dehumidification
J| operation mode indicator – cooling
K| display
L| wi-fi indicator
M| fan indicator – high speed
N| fan indicator – low speed
R| switching on the night mode
X**| change of temperature units: °C, °F

THE OPERATION OF THE APPLIANCE

  • All changes in the settings are confirmed with a sound signal.
    • The air flow from the air conditioner should not be directed directly at people.
    • The cold air flow can be controlled by means of the louvres (3).
  • In the event of a power loss and a change in operating mode, there is a 3-minute delay until the compressor restarts to protect the compressor.
    • Cooling
    • Turn on the device by pressing the „D” button.
    • Press the „F” key until the „J” indicator lights up.
    • Use buttons „C” and „E” to set the temperature in the range from 16°C to 32°C.
    • The fan speed is set using button „B”.
    • The current room temperature is shown on the display „K”.
    • The air-conditioner will turn off when the room temperature drops below the set temperature.
    • When using cooling mode, the exhaust air pipe must be connected to the unit.
    • Fan
    • In this mode, only the unit’s fan operates.
    • Switch on the appliance using button „D”.
    • Press the „F” button until the „H” indicator is illuminated.
    • The fan speed (low, high) is set using button „B”.
    • To switch off, press the „F” button (change mode) or the „D” button (switch off the device).
    • Dehumidification
    • Turn on the device by pressing the „D” button.
    • Press the „F” key until the „I” indicator lights up.
    • The dehumidifier runs continuously – the humidity level cannot be set.
    • The fan only runs at low speed.
    • When using dehumidify mode, the exhaust air pipe must be connected to the unit to allow moisture to escape.
    • Connect the hose to the condensate drain on the bottom of the unit. Place the end of the hose in a suitable container or in the water drain of the room.
    • Night mode
    • The night mode only works in conjunction with the cooling mode.
    • The night mode is activated by pressing the „R” button on the remote control.
    • The fan only runs at low speed.
    • After 1 hour from starting the mode, the set temperature is increased by 1°C, after another hour the set temperature will be increased by 1°C again.
    • The temperature is then held constant for 10 hours.
    • And all indicators are dimmed.
    • To disable the mode, press the „R” button on the remote control once again.
    • Start delay
    • The device must be switched off but connected to the power supply.
    • Press button „A” – digits will start flashing on the display „K”.
    • Use buttons „C” and „E” to select a time from 1 to 24 hours.
    • After selecting the time, wait for the digits on the display to stop flashing.
    • Select the required operating mode of the device (information above).
    • To disable the function, press the „A” button and use the „C” and „E” buttons to set the numbers „00” on the display.
    • Timer
    • Turn on the device by pressing the „D” button.
    • Select the required operating mode of the device (information above).
    • Press button „A” – digits will start flashing on the display „K”.
    • Use buttons „C” and „E” to select a time from 1 to 24 hours.
    • After selecting the time, wait for the digits on the display to stop flashing.
    • To disable the function, press the „A” button and use the „C” and „E” buttons to set the numbers „00” on the display.
    • Changing the operating mode is possible when the „TIMER” function is active.
    • Button lock
    • To activate the button lock, press and hold the “G” button for a few seconds.
    • Function activation is indicated by the indicator light.
    • When the lock is active, you cannot change the appliance settings or turn it off.
    • To deactivate the lock, press and hold the dimmed “G” button for a few seconds.

WATER DISCHARGE

  • The unit is equipped with an evaporation system. Liquefied water is used to cool the condenser, which increases the cooling efficiency and reduces energy consumption.
  • If the water level in the system reaches the maximum level, the letters (FT) will appear on the display „K” and the compressor will stop running.
  • **Manual removal of water – drawing 6.

**

  * Switch off the device and move it to a place where water can be drained from it.
  * Remove the plug from the hole „14” and carefully drain the water.
  * Insert the plug into the hole „14”.
  * Turn the device on again.
  • **Constant water drainage – drawing 7.

**

  * Turn the appliance off.
  * Remove the plug from the hole „10”.
  * Mount the rubber tube (not included) and place its other end in a container, e.g. a bucket.

MAINTENANCE

Note: Turn off the unit and unplug it before any maintenance or repair begins to avoid electric shock.

  • Cleaning
    • Unplug the unit before any cleaning.
    •  Clean the housing with a soft moisture cloth. Do not use chemical solvent (such as benzene, alcohol, gasoline). The surface may be damaged or even the whole case may be deformed.
    • Do not sprinkle water on the unit.
  • **Air filter – drawing 8.

**

  * Clean the air filter every 2 weeks. If the air filter is blocked with dust, the efficiency will reduce.
  * Open the air filter cover upwards, and then take out the air filter.
  * Wash the air filter by immersing it gently into warm (about 40oC) water with a neutral detergent, rinse it and dry it thoroughly in a shaded place.
  • End of season
    • Please drain the water.
    •  Keep the unit running in Fan mode for two hours until the inside of the unit is dry.
    • Turn off the unit and unplug it.
    • Clean the air filter and after dry it thoroughly, reinstall it.
    • Remove the exhaust pipes and keep them carefully.
    • Wrap the unit with the plastic bag and keep it in a dry place.

TROUBLE SHOOTING

Before contacting professional service, check it first yourself referring to the followings

Problem Cause Solution

The air conditioner does not

function.

| No power supply.| Connect to power supply outlet and switch on
“FT” flashes on the display screen| Drain water
Timer-off is running.| You can turn on the unit three minutes later..

The air conditioner restart

frequently

| In direct sunlight| Close curtains.
Windows or doors open many people or a heat source in the room.| Close doors and windows remove the heat source
Dirty filter| Clean or replace the filter(s).
Air inlet or air outlet blocked| Remove the blockage
The unit is too noisy| Unit stands uneven.| Place on an even, solid surface (less vibration).
No work of compressor.|

Self protect of compressor

| Wait for 3 minute and restart again after the descend of temperature

Cautions: Switch off the unit and unplug it immediately if anything abnormal happens. Then contact a qualified electrician. Above data without advance notice for product improvement.

TECHNICAL DATA

The full technical specification can be found on the rating plate located on the device.

Power supply 220-240V ~50Hz
Cooling medium R290/170g
Cooling efficiency 9000Btu/h (2.637kW)
Power consumption 1005W
Air flow 290m³/h

Fuse parameters of the machine

  • Type: T
  • Voltage: 250V
  • Current: 3.15 A

SIMPLIFIED EU DECLARATION OF CONFORMITY

Hereby, Eldom Sp. z o.o., ul. Pawła Chromika 5a, 40-238 Katowice declares that the radio equipment type PORTABLE AIR CONDITIONER KLC9050 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.eldom.eu/deklaracje

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

COLUMBIA VAC User Manuals

Related Manuals