TELE E3ZI20 Timers – Asymmetric Flasher Instruction Manual

June 4, 2024
TELE

TELE E3ZI20 Timers – Asymmetric Flasher

Timers – Asymmetric flasher

  • series ENYA
  • 2-time multifunction
  • 7 time ranges
  • Wide input voltage range
  • 2 change-over contacts
  • Width 35mm
  • Installation design

Technical data

Functions
The function has to be set before connecting the relay to the supply voltage.

  • Ip Asymmetric flasher pause first
  • Ii Asymmetric flasher pulse first
  • ER ON delay and OFF delay with control contact
  • EWu ON delay single shot leading edge voltage controlled
  • EWs ON delay single shot leading edge with control contact
  • WsWa Single shot leading and single shot trailling edge with control contact
  • Wt Pulse sequence monitoring

Time ranges

  • Time range Adjustment range
  • 1s 50ms 1s
  • 10s 500ms 10s
  • 1min 3s 1min
  • 10min 30s 10min
  • 1h 3min 1h
  • 10h 30min 10h
  • 100h 5h 100h

Indicators

  • Green LED U/t ON: indication of supply voltage
  • Green LED U/t slow flashing: indication of time period t1
  • Green LED U/t fast flashing: indication of time period t2
  • Yellow LED ON/OFF: indication of relay output

Mechanical design

Self-extinguishing plastic housing, IP rating IP40 Mouted on DIN-Rail TS 35 according to EN 60715 Mounting position: anyShockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 Tightening torque: max. 1Nm Terminal capacity:

  • 1 x 0.5 to 2.5mm² with/without multicore cable end
  • 1 x 4mm² without multicore cable end
  • 2 x 0.5 to 1.5mm² with/without multicore cable end
  • 2 x 2.5mm² flexible without multicore cable end

Input circuit

  • Supply voltage: 12 to 240V a.c./d.c.
  • Terminals: A1(+)- A2
  • Tolerance: -10% to +10%
  • Rated frequency: 48 to 63Hz
  • Rated consumption: 6VA (2W)
  • Duration of operation: 100%
  • Reset time: 100ms
  • Residual ripple of d.c.:
  • Drop-out voltage : >30% of supply voltage
  • Overvoltage category : III (in accordance with IEC 60664-1)
  • Rated surge voltage: 4kV

Output circuit

2 potential free change over contacts

  • Rated voltage: 250V a.c.
  • Switching capacity: 2000VA (8A / 250V)
  • Fusing: 8A fast acting
  • Mechanical life: 20 x 106 operations
  • Electrical life: 2 x 105 operations at 1000VA resistive load
  • Switching frequency: max. 6/min at 1000VA resistive load (in accordance with IEC 60947-5-1)
  • Overvoltage category: III (in accordance with IEC 60664-1)
  • Rated surge voltage: 4kV

Control input

  • Input not potential free: terminals A1-B1
  • Loadable: yes
  • Max. line length: 10m
  • Trigger level (sensitivity): automatic adaption to supply voltage
  • Max. control pulse length : d.c. 50ms / a.c. 100ms

Accuracy

  • Base accuracy: ±1% of maximum scale value
  • Adjusting accuracy: ≤5% of maximum scale value
  • Repetition accuracy: <0.5% or ±5ms
  • Voltage influence:
  • Temperature influence: ≤0.01% / °C

Ambient conditions

  • Ambient temperature : -25 to +55°C
  • Storage temperature: -25 to +70°C
  • Transport temperature: -25 to +70°C
  • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3)
  • Pollution degree: 2 (in accordance with IEC 60664-1)

Weight

  • Single packing: 106g

Functions

Asymmetric flasher pause first (lp)
When the supply voltage U is applied, the set interval t1 begins (green LED U/t flashes slowly). After the interval t1 has expired, the output relay R switches into on-position (yellow LED illuminated) and the set interval t2 begins (green LED U/t flashes fast). After the interval t2 has expired, the output relay switches into off-position (yellow LED not illuminated). The output relay is triggered at the ratio of t1:t2 until the supply voltage is interrupted.TELE-E3ZI20-Timers-Asymmetric-Flasherc-
fig-1

Asymmetric flasher pulse first (li)
When the supply voltage U is applied, the output relay R switches into on- position (yellow LED illuminated) and the set interval t1 begins (green LED U/t flashes slowly). After the interval t1 has expired, the output relay switches into off-position (yellow LED not illuminated) and the set interval t2 begins (green LED U/t flashes fast). After the interval t2 has expired, the output relay switches into on-position (yellow LED illuminated). The output relay is triggered at the ratio of t1:t2 until the supply voltage is interrupted.TELE-E3ZI20-Timers-Asymmetric-Flasherc-
fig-2

ON delay and OFF delay with control contact (ER)
The supply voltage U must be constantly applied to the device (green LED U/t illuminated). When the control contact S is closed, the set interval t1 begins (green LED U/t flashes slowly). After the interval t1 has expired, the output relay R switches into on-position (yellow LED illuminated). If the control contact is opened, the set interval t2 begins (green LED U/t flashes fast). After the interval t2 has expired, the output relay Switches into off-position (yellow LED not illuminated). If the control contact is opened before the interval t1 has expired, the interval already expired is erased and is restarted with the next cycle.TELE-E3ZI20-Timers-Asymmetric-Flasherc-
fig-3

ON delay and single shot leading edge voltage controlled (EWu)
When the supply voltage U is applied, the set interval t1 begins (green LED U/t flashes slowly). After the interval t1 has expired, the output relay R switches into on-position (yellow LED illuminated) and the set interval t2 begins (green LED U/t flashes fast). After the interval t2 has expired, the output relay switches into off-position (yellow LED not illuminated). If the supply voltage is interrupted before the interval t1+t2 has expired, the interval already expired is erased and is restarted when the supply voltage is next applied.TELE-E3ZI20-Timers-Asymmetric-Flasherc-
fig-4

ON delay and single shot leading edge with control contact (EWs)
The supply voltage U must be constantly applied to the device (green LED U/t illuminated). When the control contact S is closed, the set interval t1 begins (green LED U/t flashes slowly). After the interval t1 has expired, the output relay R switches into on-position (yellow LED illuminated) and the set interval t2 begins (green LED U/t flashes fast). After the interval t2 has expired, the output relay switches into off-position (yellow LED not illuminated). During the interval, the control contact can be operated any number of times. A further cycle can only be started when the cycle run has been completed.TELE-E3ZI20-Timers-Asymmetric-Flasherc-
fig-5

Single shot leading and single shot trailing edge with control contact (WsWa)
The supply voltage U must be constantly applied to the device (green LED U/t illuminated). When the control contact S is closed, the output relay R switches into on-position (yellow LED illuminated) and the set interval t1 begins (green LED U/t flashes slowly). After the interval t1 has expired, the output relay R switches into off-position (yellow LED not illuminated). If the control contact is opened, the output relay again switches into on-position (yellow LED illuminated) and the set interval t2 begins (green LED U/t flashes fast). After the interval t2 has expired the output relay switches into off- position (yellow LED not illuminated). During the interval, the control contact can be operated any number of times.TELE-E3ZI20-Timers-Asymmetric-
Flasherc-fig-6

Pulse sequence monitoring (Wt)
When the supply voltage U is applied, the set interval t1 begins (green LED U/t flashes slowly) and the output relay R switches into on-position (yellow LED illuminated). After the interval t1 has expired, the set interval t2 begins (green LED U/t flashes fast). So that the output relay R remains in on- position, the control contact S must be closed and opened again within the set interval t2. If this does not happen, the output relay R switches into off- position (yellow LED not illuminated) and all further pulses at the control contact are ignored. To restart the function the supply voltage must be interrupted and reapplied.TELE-E3ZI20-Timers-Asymmetric-Flasherc-
fig-7

Connections

Dimensions

Ordering information

Type Functions Supply voltage Part. No. (PQ 1)
E3ZI20 12-240V a.c./d.c. lp, li, ER, EWu, WsWa, Wt 12-240V a.c./d.c. 111101

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals