Overview
Features
- Multi-function single unit battery charger or power supply operation modes selectable
- Output voltage and current adjustable via potentiometer
- 3-stage charging curve for charging mode
- -30N+700c
- wide operating temperature
- Multiple protections: Short circuit / Over load / Over voltage / Over temperature
- Thermal controlled DC fan for noise reduction
- Remote ON-OFF control
- Comply with 62368-1+60335-1 /-2-29 dual certification
- Suitable for lead-acid (Pb) batteries
Applications
- Radio system backup solution
- Electric scooter charger
- Camping car Buses Heavy duty truck Specialty vehicles
- Surveillance system
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
GTIN CODE
- MW Search: https://www.meanwell.com/serviceGTlN.aspx
Description
NPP-450 is a miniaturized dual-purpose charger and power supply. In addition to being used as a three- stage charger for lead-acid batteries, it can also be used as a constant voltage output power supply to drive general load. The operating mode can be quickly switched by plugging or unplugging a connector on the front panel. Other features include: ultra-wide voltage output, adjustable voltage via VR on the panel (10.5N21V, 21 N42V, 42N80V, 54N100V), adjustable charging current (50N100%), built-in intelligent fan with variable speed based on temperature to reduce noise and extend fan lifetime, 30N+700 C wide operating temperature, suitability for use in different environments, built-in remote ON/OFF control, compliance to IEC/EN/UL62368-1 and household EN60335-1/-2-29 dual safety, multiple built-in protections, and 3-year warranty. The NPP-450 is truly an intelligent, safe, and reliable universal dual-purpose charger and power supply with outstanding cost performance.
Model Encoding
SPECIFICATION
SPECIFICATION for Battery Charger mode (Default)
MODEL | NPP-450-12 | NPP-450-24 | NPP-450-48 | NPP-450-72 |
---|
OUTPUT
| BOOST CHARGE VOLTAGE(Vboost)(default)| 14.4V| 28.8V| 57.6V| 72V
FLOAT CHARGE VOLTAGE(Vfloat)(default)| 13.8V| 27.6V| 55.2V| 69V
VOLTAGE ADJUSTABLE RANGE
| 10.5 ~ 21V| 21 ~ 42V| 42 ~ 80V| 54 ~ 100V
By built-in potentionmeter
MAX. OUTPUT CURRENT(CC)| 25A| 13.5A| 6.8A| 5.5A
CURRENT ADJUSTABLE RANGE
Note.3
| 12.5 ~ 25A| 6.75 ~ 13.5A| 3.4 ~ 6.8A| 2.75 ~ 5.5A
By built-in potentionmeter
MAX. POWER| 420W| 453.6W| 456.96W| 462W
RECOMMENDED BATTERY CAPACITY (AMP HOURS) Note.4| 90 ~ 300AH| 45 ~
155AH| 24 ~ 80AH| 19 ~ 64AH
INPUT
| VOLTAGE RANGE Note.5| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.98/115VAC, PF>0.95/230VAC at full load
EFFICIENCY (Typ.) Note.6| 92%| 93%| 93%| 93%
AC CURRENT (Typ.)| 4.5A/115VAC 2.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 50A at 230VAC
PROTECTION
| SHORT CIRCUIT Note.7| Protection type: Constant current limiting, charger will shutdown after 5 sec, re-power on to recover
OVER VOLTAGE
| 21.5 ~ 26V| 43 ~ 52V| 82 ~ 100V| 102 ~ 120V
Protection type: Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down O/P voltage, recovers automatically after
temperature goes down
FUNCTION
| CHARGING STAGE| 3 stage only
CHARGER OK SIGNAL| The TTL signal out, Charger OK = H(4.5 ~ 5.5V) ;
Charger failure or protection status =L( -0.5 ~ +0.5V)
BATTERY FULL SIGNAL| The TTL signal out, Battery full = H(4.5 ~ 5.5V );
Charging = L(-0.5 ~ +0.5V)
REMOTE CONTROL| Open : Charger stop charging Short : Charger
normal work
FAN SPEED CONTROL| Depends on internal temperature
ENVIRONMENT
| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
(Note 8)
| SAFETY STANDARDS| CB IEC62368-1,IEC60335-1/2-29, Dekra BS
EN/EN62368-1,BS EN/EN60335-1/2-29, UL62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Radiated| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY
| BS EN/EN61000-6-2
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2, 3V/m
EFT / Burst| BS EN/EN61000-4-4| Level 2, 1KV
Surge| BS EN/EN61000-4-5| Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 2, 3Vrms
Magnetic Field| BS EN/EN61000-4-8| Level 1, 1A/m
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,
95% interruptions 250 periods
OTHERS
| MTBF| 1056.9K hrs min. Telcordia SR-332 (Bellcore) ;
118.5K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 20513555mm (LWH)
PACKING| 1.02Kg; 8pcs/ 10Kg / 1.71CUFT
NOTE
|
- Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- Float charge voltage(Vfloat) adjustable via potentiometer in battery charger mode.
- This is MEAN WELL’s suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
- Derating may be needed under low input voltages. Please check the derating curve for more details.
- The efficiency is measured at 16.8V charge voltage(12V model), 33.6V charge voltage(24V model), 67.2V charge voltage(48V model), 84V charge voltage(72V model).
- This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
- The charger is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
SPECIFICATION for Power Supply mode (Selectable via pin3 & 4 jumper of 14pins connector on panel)
MODEL | NPP-450-12 | NPP-450-24 | NPP-450-48 | NPP-450-72 |
---|
OUTPUT
| DC VOLTAGE| 14.4V| 28.8V| 57.6V| 72V
VOLTAGE ADJUSTABLE RANGE
| 10.5 ~ 21V| 21 ~ 42V| 42 ~ 80V| 54 ~ 100V
By built-in potentionmeter
CURRENT ADJUSTABLE RANGE| 12.5 ~ 25A| 6.75 ~ 13.5A| 3.4 ~ 6.8A| 2.75 ~
5.5A
RATED CURRENT| 25A| 13.5A| 6.8A| 5.5A
RATED POWER| 420W| 453.6W| 457W| 462W
RIPPLE & NOISE(max.)| 180mVp-p| 300mVp-p| 480mVp-p| 600mVp-p
VOLTAGE TOLERANCE| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1800ms, 60ms/230VAC at full load
HOLD UP TIME (Typ.)| 16ms/230VAC at 75% load 10ms/230VAC at full load
INPUT
| VOLTAGE RANGE Note.3| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.98/115VAC, PF>0.95/230VAC at full load
EFFICIENCY (Typ.)| 92%| 93%| 93%| 93%
AC CURRENT (Typ.)| 4.5A/115VAC 2.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 50A at 230VAC
PROTECTION
| ****
OVERLOAD
| 105 ~ 115% rated output power
Protection type : Constant current limiting, unit will shutdown after 5 sec,
re-power on to recover
SHORT CURRENT| Protection type : Constant current limiting, unit will
shutdown after 5 sec, re-power on to recover
OVER VOLTAGE
| 21.5 ~ 26V| 43 ~ 52V| 82 ~ 100V| 102 ~ 120V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down O/P voltage, recovers automatically after
temperature goes down
FUNCTION
| REMOTE CONTROL| Open : Power OFF Short : Power ON
DC OK| The TTL signal out, DC OK = H(4.5 ~ 5.5V) ; Power supply failure
or protection = L(-0.5 ~ +0.5V)
FAN SPEED CONTROL| Depends on internal temperature
ENVIRONMENT
| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
(Note 4)
| SAFETY STANDARDS| CB IEC62368-1,IEC60335-1/2-29, Dekra BS
EN/EN62368-1,BS EN/EN60335-1/2-29, UL62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Radiated| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY
| BS EN/EN61000-6-2
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2, 3V/m
EFT / Burst| BS EN/EN61000-4-4| Level 2, 1KV
Surge| BS EN/EN61000-4-5| Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 2, 3Vrms
Magnetic Field| BS EN/EN61000-4-8| Level 1, 1A/m
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,
95% interruptions 250 periods
OTHERS
| MTBF| 1056.9K hrs min. Telcordia SR-332 (Bellcore) ;
118.5K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 20513555mm (LWH)
PACKING| 1.02Kg; 8pcs/ 10Kg / 1.71CUFT
NOTE
|
- Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- Derating may be needed under low input voltages. Please check the derating curve for more details.
- The PSU is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
Derating Curve
Function Manual
Battery Charger or Power Supply Operation modes selectable via pin3 and pin4 jumper
Between pin3 and pin4 | Operation modes |
---|---|
Jumper connected | Power supply mode |
Jumper removed | Battery charger mode (Default) |
Charging Curve (Charging Mode)
- 3 stage charging curve
State | NPP-450-12 | NPP-450-24 | NPP-450-48 | NPP-450-72 |
---|---|---|---|---|
Constant Current |
25A
|
13.5A
|
6.8A
|
5.5A
Vboost| 14.4V| 28.8V| 57.6V| 72V
Vfloat| 13.8V| 27.6V| 55.2V| 69V
- Suitable for lead-acid batteries (flooded, Gel and AGM)
- VO x IO must be less than or equal to the rated power. Please refer to derating curve.
Charger OK / DC OK Signal
- Charger OK / DC OK signal is a TTL level signal.
- The maximum sourcing current is 10mA.
Charger OK / DC OK signal | Charger status |
---|---|
“High”: 4.5 ~ 5.5V | Work normally |
“Low” : -0.5 ~ 0.5V | Failure or protection function activated |
Remote ON-OFF Control
- The NPP-450 can be turned ON/OFF by using the “Remote Control” function.
Mechanical Specification
Connector Pin No. Assignment : HRS DF11-14DP-2DS or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1,2,11~14 | NC |
HRS DF11-14DS
or equivalent
|
HRS DF11-**SC
or equivalent
3,4| Battery Charger or
Power Supply mode selectable
5| Battery Full
6| Charger OK (Charger mode) or
DC OK (Power supply mode)
7| Remote ON-OFF
8| +12V-AUX
9,10| GND-AUX
LED Status Table
Charger (Default)
LED Indicator| Status
Green| Float stage (stage 3) or full charged
Red| Charging (stage 1 or stage 2)
No Light| Abnormal
Power supply mode
LED Indicator| Status
Green| Normal working
No Light| Abnormal
Control Pin No. Assignment: HRS DF11-14DP-2DS or equivalent
Mating Housing | HRS DF11-14DS or equivalent |
---|---|
Terminal | HRS DF11-**SC or equivalent |
Pin No. | Function | Description |
---|---|---|
1,2,11~14 | NC | —– |
3,4
| Battery charger / Power supply| Open: Battery charger, Color of LED loading indicator: Reference to battery charger. Short: Power supply, Color of LED loading indicator:Green.
5
|
Battery Full
| Battery Full Signal, referenced to GND-AUX(Pin 9 & 10).
The Signal is a TTL-level signal. The maximum sourcing current is 10mA and only for output.(Note.2) Low (-0.5 ~ 0.5V) : When the battery is charging.
High (4.5 ~ 5.5V) : When the battery is full.
6
|
Charger OK / DC OK
| Charger OK / DC OK Signal, referenced to GND-AUX(Pin 9 & 10).
The Signal is a TTL level signal. The maximum sourcing current is 10mA and only for output.(Note.2) Low (-0.5 ~ 0.5V) : When the charger fails or the protect function is activating.
High (4.5 ~ 5.5V) : When the charger is working properly.
7
|
Remote ON-OFF
| Remote charger ON/OFF Function.
The charger can turn the output ON/OFF by dry contact between Remote ON-OFF and +12V-AUX.(Note.2) Short (10.8 ~ 13.2V) : Charger ON ; Open(-0.5 ~ 0.5V) : Charger OFF ; The maximum input voltage is 13.2V.
8| +12V-AUX| It is controlled by the Remote ON-OFF control.
9,10| GND-AUX| The signal return is isolated from the output terminal. (+V &
-V)
Note
- Non-isolated signal, referenced to [GND(signal)].
- Isolated signal, referenced to GND-AUX
Accessory List
Battery Charger or Power Supply mode of pin 3 and pin 4 mating pin along with NPP-450 (Standard accessory)
Pin 3 and Pin 4 mating pin | Quantity |
---|---|
1 |
Carry handle (Optional accessory, battery charger and pull handle should be ordered seperately)
MW’s Order No. | Item | Quantity |
---|---|---|
DS-Carry Handle | 1 | Handle |
2 | Foot pad |
| 4
3| Screw
| 2
Handle
Footpad
INSTALLATION MANUAL