HEATSCOPE Smartbox Somfy NEXT Design Carbon Heaters Instruction Manual
- June 11, 2024
- HEATSCOPE
Table of Contents
- Saltbox Comfy NEXT Design Carbon Heaters
- UNPACKING THE UNIT / PACKAGING
- Scope of Delivery
- Optionally Available
- OPENING THE LID OF THE UNIT
- ELECTRICAL CONNECTION HEATSCOPE® SMARTBOX
- OPERATION, INSTALLATION INSTRUCTIONS AND MIN. DISTANCES
- INSTALLATION INSTRUCTIONS
- SMARTBOX CONTROL VIA INFRARED REMOTE
- SMARTBOX CONTROL VIA SOMFY® I/O
- AUTO-OFF FEATURE
- CARE, MAINTENANCE AND SERVICE
- REMOVAL FROM SERVICE / DISPOSAL
- GUARANTEE AND WARRANTY
- PROCESSING OF GUARANTEE CLAIMS
- WARRANTY EXCLUSIONS
- CONTACT PARTNERS IN YOUR AREA
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Saltbox Sofie NEXT Design Carbon Heaters
Instruction Manual
Saltbox Comfy NEXT Design Carbon Heaters
SMARTBOX for HEATSCOPE® PURE, PURE+ and NEXT design carbon heaters
The HEATSCOPE® SMARTBOX is a remote control device for all external
controllable HEATSCOPE® infrared heaters. The SMARTBOX must be used
exclusively in combination with HEATSCOPE® models PURE, + PURE and NEXT. The
SMARTBOX will not work with heaters made by other brands!
Additionally to the information in this manual, all instructions and
guidelines of the original HEATSCOPE® heater manual are mandatory, which you
have received with your HEATSCOPE® infrared heater.
Before installing the unit, please read this instruction manual carefully.
Follow the information given to avoid endangering yourself, your family, your
friends and your acquaintances. If you have any questions, contact the vendor
or manufacturer.
Please keep this instruction manual in a safe place. Pass on the manual to any
subsequent owner of the HEATSCOPE® unit and ensure that any supplements
received are included along with it. This manual is also available online:
www.heatscope.com
Prior to installation, ensure that the operating voltage matches the one
specified on the rating plate of the HEATSCOPE® unit!
UNPACKING THE UNIT / PACKAGING
Unpack the unit and the accessories carefully. When opening the packaging, do
not use sharp objects that could damage the unit.
This product comes supplied in environmentally friendly packaging. All
HEATSCOPE® packaging that comes into circulation either directly or via the
trade is certified in accordance with §6 of the German Packaging Directive. As
a result, all HEATSCOPE® packaging can be disposed of in an environmentally
friendly manner in collection containers for packaging materials. All legal
regulations must be observed here. Further information is available from the
manufacturer.
Important care information! Clean the unit with a damp cloth before using it
for the first time. Do not use cleaning products containing alkaline
substances such as sodium hydroxide or soap, surfactants or solvents/alcohol.
TECHNICAL DATA HEAT Scope® SMARTBOX
Voltage | 220-240 V AC ~, 50/60 Hz |
---|---|
IP rating class | IP 65 |
Remote control | ON/OFF + 100%, 50% |
Measurements | 100 x 170 x 35.5 mm |
Weight | 0.35 kg / 0.51 kg incl. Mounting panel |
Scope of Delivery
HEATSCOPE® SMARTBOX| MOUNTING PANEL| HEATSCOPE REMOTE CONTROL UNIT
2 BATTERIES AAA
---|---|---
Optionally Available
MOUNTING PANEL FOR SEPARATE INSTALLATION (cf. extra installation manual)
PLEASE CONTACT YOUR HEATSCOPE® PARTNER WHEN NEEDED
Small SMARTBOX Mounting Panel: MHS-SBOXMP
OPENING THE LID OF THE UNIT
ELECTRICAL CONNECTION HEATSCOPE® SMARTBOX
FOR INSTALLATION WITH PURE MOUNTING BRACKET.
FOR CONCEALED INSTALLATION WITH WALL OPENING.
ONLY POSSIBLE FOR INSTALLATION WITHOUT PURE MOUNTING BRACKET.
PLEASE NOTE: YOU WILL NEED A SEPARATE SMALL MOUNTING PANEL FOR THIS SPECIAL
INSTALLATION. PLEASE CONTACT YOUR HEATSCOPE® PARTNER.
ONLY FOR ADDITIONAL UNITS (E.G. MOTION SENSORS).
CLOSING THE LID OF THE HEATSCOPE® SMARTBOX
INSTALLING WITH MOUNTING EQUIPMENT OF THE HEATSCOPE® PURE
BOLT PURE MOUNTING BRACKET WITH MOUNTING PANEL ON DESIRED INSTALLATION SITE.
OPERATION, INSTALLATION INSTRUCTIONS AND MIN. DISTANCES
HEATSCOPE® features two omnipolar ,ON/OFF“ switches.
To make sure that you can control the heater via the SMARTBOX, both switches
must be in the ON position.
The unit must be connected to a residual current circuit breaker!
All cables must be positioned so that they cannot come into contact with the
surface of the radiant heater at any time.
INSTALLATION INSTRUCTIONS
HEATSCOPE® infrared heaters as well as all connecting units must be installed
only by an authorized expert / professional electrician.
The different options for installing the HEATSCOPE® SMARTBOX together with a
HEATSCOPE® heater are shown in the diagrams of this manual.
Ensure that the SMARTBOX and the heater are fixed securely to the installation
surface. Please refer to the original installation manual of the PURE / PURE*
/ NEXT, which you have received with the heater itself.
WALL MOUNTING OF THE HEATSCOPE® SMARTBOX WITH HEATSCOPE® PURE
CEILING MOUNTING OF THE HEATSCOPE® SMARTBOX
CEILING MOUNTING OF THE HEATSCOPE® SMARTBOX ON RAFTERS
SMARTBOX CONTROL VIA INFRARED REMOTE
The HEATSCOPE® SMARTBOX standard version can be controlled via enclosed
infrared remote control.
To make this work properly you have to switch on both switches on the heater
itself.
Included in the scope of delivery is a HEATSCOPE® remote control unit
(batteries included). With this remote you can switch the heater ON/OFF as
well as switch it down to 50% and back again to 100% power.
SMARTBOX control via infrared remote
The remote control via infrared will only work if the SMARTBOX is not
covered by the heater; you have to ensure an unobstructed view between the two
devices. If necessary please change your position to make sure, you can
control the heater via remote.
SMARTBOX CONTROL VIA SOMFY® I/O
Additionally to the standard version of the SmartBox-xxxx there is also a
comfy® I/O unit available.
You can control the HEATSCOPE® via the somfy® I/O SMARTBOX (ON/OFF, 50%, 100%
power) straightaway with your somfy® remote (not included in the scope of
delivery). You have to make sure again, that both switches on the heater has
been switched on.
Functionality and connection of your somfy® I/O Satu remote control:
Choose the favored channel on your somfy® remote on which you want to program
the heater. After this press the PROGRAM button.
To interconnect your somfy® remote please disconnect the power supply for 3
seconds from the heater and the SMARTBOX, connect them again for 8 seconds and
disconnect them finally for 3 seconds. After this you can switch on the power
supply regularly.
This is the standard procedure to integrate new somfy* modules. The SMARTBOX
will now turn on for 3 to 5 seconds (both LED on the SMARTBOX will light up
red) and after max. 5 seconds it will turn off again.
Now the SMARTBOX was recognized from the Satu I/O remote control and it can be
switched as follows:
- Choose the programmed channel of the heater.
- Press UP button shortly: the heater will power up at 100%.
- Press DOWN button for long: the heater will switch down to 50%.
- Press UP button for long: the heater will switch up again to 100%.
- Press DOWN button shortly: the heater will switch off.
AUTO-OFF FEATURE
The SMARTBOX is equipped with an Auto-OFF feature (not available with somfy®
I/O control unit).
This additional feature switches off the heater after a specific period of
time.
As soon as the HEATSCOPE® heater is regulated via SMARTBOX and IR control unit
(50% — 100%, 100% — 50%), the preprogrammed Auto-OFF feature resets to zero.
Now the timer function starts again.
Standard: Auto-OFF activated (4h)
To change the standard setting, click the DOWN button of the remote 5x with
max. 1 sec. interval right after connecting the HEATSCOPE® and SMARTBOX with
the power supply.
After recognizing this command the blue LED will switch off and the two red
LED will start blinking 3x slowly (1sec on, isec. off). After this the
SMARTBOX is in setup mode. The two red LED will show the actual setup of the
Auto-Off feature. The blue LED will not light!
With the help of the UP/DOWN buttons of the remote you can change the setup
easily.
To save the desired new setup, just press the ON/OFF button finally.
Upper LED | Lower LED | Auto-oFF feature |
---|---|---|
off | off | deactivated |
off | on | 4 hours |
on | off | 6 hours |
on | on | 8 hours |
If no button is pressed for more than 1 minute in the setup mode, the setup
will be closed without any changes.
The setup mode can be reached only after connecting the HEATSCOPE® and the
SMARTBOX with a power supply! After switching on the heater via remote, the
setup mode is only reachable after disconnecting the unit from the main power
supply.
CARE, MAINTENANCE AND SERVICE
Before cleaning and maintaining your HEATSCOPE® SMARTBOX disconnect it from
the power supply or, if buried cables are used, switch it off via the omni
polar switches. All surfaces should be cleaned using a damp cloth only.
Never use cleaning products containing alkaline substances such as sodium
hydroxide or soap, surfactants or solvents such as alcohol. Use only a very
soft cloth or a brush for the reflector and the heating elements.
Changing the PCB is only permitted with original equipment and must only be
carried out by an authority delegated by the manufacturer. Damage or defects
caused by improper handling or operation as well as defects caused by using
nonoriginal parts or the use of accessories not recommended by the
manufacturer are not covered by the warranty.
REMOVAL FROM SERVICE / DISPOSAL
When the unit reaches the end of its life, it must be removed from service by
a specialist in accordance with the relevant regulations and steps must be
taken to ensure that it cannot be put into use again.
The unit must be disposed of professionally and in an environmentally friendly
manner. The relevant legal regulations must be observed.
GUARANTEE AND WARRANTY
All HEATSCOPE® devices are guaranteed for 24 months. The warranty period begins with the date on which the new unit was purchased. Expendable parts or defects that affect the usability of the unit only slightly are not covered by the guarantee. When making a guarantee claim, you must provide the original invoice showing the date of purchase and the unit model.
PROCESSING OF GUARANTEE CLAIMS
Please contact your dealer/distributor before returning the defective unit
along with valid proof of purchase and a detailed description of the fault.
Please note: Don‘t send in any devices to the manufacturer without any former
contact with your distributor or dealer. He will inform you about all
following steps. The manufacturer will only accept the unit, if it is
returned with adequate transport packaging which protects it securely during
transport.
The manufacturer will, at his own discretion, fulfil his warranty obligations
by either repairing or exchanging the faulty unit or individual parts of the
faulty unit. If a unit is replaced, the shape and colour of the new unit may
vary slightly from the original one. The guarantee period shall not be
extended if the unit was replaced or repaired by the manufacturer.
WARRANTY EXCLUSIONS
Damage or defects caused by improper handling or operation as well as defects
caused by using nonoriginal parts or the use of accessories not recommended by
the manufacturer are not covered by the warranty.
The warranty does not cover damages caused by external influences such as
fire, lightning or any transport damages. Liability for consequential damages
to persons or property is excluded.
If the serial number of the unit has been changed, removed or defaced, the
warranty will be invalid.
All warranty claims shall be forfeited if the unit is opened, altered,
modified, rebuilt or repaired by a person not authorized by the manufacturer.
The declaration of conformity (CE, WEEE, RoHS) is available upon request from
the manufacturer.
CONTACT PARTNERS IN YOUR AREA
THE NORTHERN COUNTRIES
Denmark, Sweden, Norway, Finland, Iceland
Monic GmbH
Kramergasse 32
D-82054 Sauerlach-Lochhofen
Tel.: +49 8104 647090
Fax: +49 8104 647099
heatscope@moonich.de
www.moonich.de
USA, CANADA, NORTH AMERICA
MAD Design USA
5875 Green Valley Circle, Suite 100
Culver City, CA 90230 USA
Tel.: + 1 (888) 590.3335
info@mad-usa.com
www.mad-usa.com
UK & Ireland
MAD Design UK Ltd
3rd Floor, 5 Lloyds Avenue
London EC3N 3AE UK
Tel.: +44 0333 444 0623
info@mad-uk.com
www.mad-uk.com
References
- Travel to Australia - Australian Tourism Information - Tourism Australia
- Ethanol Fireplaces, Fire Pits, Fire Tables, Radiant Heaters, Concrete Furniture, and Bioethanol Fuel - MAD
- UK.COM
- USA Location information - USA.com
- HOME ARCHIFLAME - www.archiflame.gr
- Home - BF Consult
- Delicaat
- ecoenergie srl - Riscaldamento ad infrarossi per esterno, lampade riscaldanti ad infrarossi, stufe a raggi infrarossi
- Profi-Partner Elektrotechnik für den B2B-Vertrieb, für Beratung + Entwicklung | Elka Krischke - Ihr Profi-Partner Elektrotechnik
- Design-Heizstrahler mit weniger Licht + mehr Wärme HEATSCOPE
- HEATSCOPE - německá designová infratopidla
- Promienniki ciepła - producent HEATSCOPE
- Heatscope Ibérica | Calor de diseño | Heatscope
- Kabe Žilina - čistiace stroje
- Ethanol Fireplaces, Fire Pits, Fire Tables, Radiant Heaters, Concrete Furniture, and Bioethanol Fuel - MAD
- Ethanol Fireplaces, Electric Fireplaces, Gas Fire Pits and Fire Tables, Radiant Heaters, Concrete Furniture, Bioethanol Fuel - MAD
- MOONICH - brands for atmosphere, Interior Design südlich von München
- Patio Exterior – .
- Ana Sayfa
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>