SMARTBOX for HEATSCOPE® PURE, PURE+ and NEXT design carbon heaters
The HEATSCOPE® SMARTBOX is a remote control device for all external controllable HEATSCOPE® infrared heaters. The SMARTBOX must be used exclusively in combination with HEATSCOPE® models PURE, + PURE and NEXT. The SMARTBOX will not work with heaters made by other brands!
Additionally to the information in this manual, all instructions and guidelines of the original HEATSCOPE® heater manual are mandatory, which you have received with your HEATSCOPE® infrared heater.
Before installing the unit, please read this instruction manual carefully. Follow the information given to avoid endangering yourself, your family, your friends and your  acquaintances. If you have any questions, contact the vendor or manufacturer.
Please keep this instruction manual in a safe place. Pass on the manual to any subsequent owner of the HEATSCOPE® unit and ensure that any supplements received are  included along with it. This manual is also available online: www.heatscope.com
Prior to installation, ensure that the operating voltage matches the one specified on the rating plate of the HEATSCOPE® unit!

UNPACKING THE UNIT / PACKAGING

Unpack the unit and the accessories carefully. When opening the packaging, do not use sharp objects that could damage the unit.
This product comes supplied in environmentally friendly packaging. All HEATSCOPE® packaging that comes into circulation either directly or via the trade is certified in accordance with §6 of the German Packaging Directive. As a result, all HEATSCOPE® packaging can be disposed of in an environmentally friendly manner in collection containers for packaging materials. All legal regulations must be observed here. Further information is available from the manufacturer.
Important care information! Clean the unit with a damp cloth before using it for the first time. Do not use cleaning products containing alkaline substances such as sodium  hydroxide or soap, surfactants or solvents/alcohol.

TECHNICAL DATA HEAT Scope® SMARTBOX

Voltage  220-240 V AC ~, 50/60 Hz
IP rating class  IP 65
Remote control  ON/OFF + 100%, 50%
Measurements  100 x 170 x 35.5 mm
Weight  0.35 kg / 0.51 kg incl. Mounting panel

Scope of Delivery

HEATSCOPE® SMARTBOX| MOUNTING PANEL| HEATSCOPE REMOTE CONTROL UNIT
2 BATTERIES AAA
---|---|---
HEATSCOPE Smartbox Somfy NEXT Design Carbon Heaters -
fig

Optionally Available

MOUNTING PANEL FOR SEPARATE INSTALLATION (cf. extra installation manual)
PLEASE CONTACT YOUR HEATSCOPE® PARTNER WHEN NEEDED

Small SMARTBOX Mounting Panel: MHS-SBOXMP

OPENING THE LID OF THE UNIT

HEATSCOPE Smartbox Somfy NEXT Design Carbon Heaters - fig
2HEATSCOPE Smartbox Somfy NEXT Design
Carbon Heaters - fig 3

ELECTRICAL CONNECTION HEATSCOPE® SMARTBOX

HEATSCOPE Smartbox Somfy NEXT Design Carbon Heaters - fig
4

FOR INSTALLATION WITH PURE MOUNTING BRACKET.
FOR CONCEALED INSTALLATION WITH WALL OPENING.
ONLY POSSIBLE FOR INSTALLATION WITHOUT PURE MOUNTING BRACKET.
PLEASE NOTE: YOU WILL NEED A SEPARATE SMALL MOUNTING PANEL FOR THIS SPECIAL INSTALLATION. PLEASE CONTACT YOUR  HEATSCOPE® PARTNER.
ONLY FOR ADDITIONAL UNITS (E.G. MOTION SENSORS).

HEATSCOPE Smartbox Somfy NEXT Design Carbon Heaters - fig
5

CLOSING THE LID OF THE HEATSCOPE® SMARTBOX

HEATSCOPE Smartbox Somfy NEXT Design Carbon Heaters - fig
6HEATSCOPE Smartbox Somfy NEXT Design
Carbon Heaters - fig 7

INSTALLING WITH MOUNTING EQUIPMENT OF THE HEATSCOPE® PURE

HEATSCOPE Smartbox Somfy NEXT Design Carbon Heaters - fig
8

BOLT PURE MOUNTING BRACKET WITH MOUNTING PANEL ON DESIRED INSTALLATION SITE.

HEATSCOPE Smartbox Somfy NEXT Design Carbon Heaters - fig
9

OPERATION, INSTALLATION INSTRUCTIONS AND MIN. DISTANCES

HEATSCOPE® features two omnipolar ,ON/OFF“ switches.
To make sure that you can control the heater via the SMARTBOX, both switches must be in the ON position.
The unit must be connected to a residual current circuit breaker!
All cables must be positioned so that they cannot come into contact with the surface of the radiant heater at any time.

INSTALLATION INSTRUCTIONS

HEATSCOPE® infrared heaters as well as all connecting units must be installed only by an authorized expert / professional electrician.
The different options for installing the HEATSCOPE® SMARTBOX together with a HEATSCOPE® heater are shown in the diagrams of this manual.
Ensure that the SMARTBOX and the heater are fixed securely to the installation surface. Please refer to the original installation manual of the PURE / PURE* / NEXT,  which you have received with the heater itself.

HEATSCOPE Smartbox Somfy NEXT Design Carbon Heaters - fig
10

WALL MOUNTING OF THE HEATSCOPE® SMARTBOX WITH HEATSCOPE® PURE

HEATSCOPE Smartbox Somfy NEXT Design Carbon Heaters - fig
11

HEATSCOPE Smartbox Somfy NEXT Design Carbon Heaters - fig
12HEATSCOPE Smartbox Somfy NEXT Design
Carbon Heaters - fig 13HEATSCOPE
Smartbox Somfy NEXT Design Carbon Heaters - fig 14

CEILING MOUNTING OF THE HEATSCOPE® SMARTBOX

HEATSCOPE Smartbox Somfy NEXT Design Carbon Heaters - fig
15

CEILING MOUNTING OF THE HEATSCOPE® SMARTBOX ON RAFTERS

HEATSCOPE Smartbox Somfy NEXT Design Carbon Heaters - fig
16

SMARTBOX CONTROL VIA INFRARED REMOTE

The HEATSCOPE® SMARTBOX standard version can be controlled via enclosed infrared remote control.
To make this work properly you have to switch on both switches on the heater itself.
Included in the scope of delivery is a HEATSCOPE® remote control unit (batteries included). With this remote you can switch the heater ON/OFF as well as switch it  down to 50% and back again to 100% power.

HEATSCOPE Smartbox Somfy NEXT Design Carbon Heaters - fig
17

SMARTBOX control via infrared remote
The remote control via infrared will only work if the SMARTBOX is not covered by the heater; you have to ensure an unobstructed view between the two devices. If  necessary please change your position to make sure, you can control the heater via remote.

HEATSCOPE Smartbox Somfy NEXT Design Carbon Heaters - fig
18

SMARTBOX CONTROL VIA SOMFY® I/O

Additionally to the standard version of the SmartBox-xxxx there is also a comfy® I/O unit available.
You can control the HEATSCOPE® via the somfy® I/O SMARTBOX (ON/OFF, 50%, 100% power) straightaway with your somfy® remote (not included in the scope of delivery). You have to make sure again, that both switches on the heater has been switched on.
Functionality and connection of your somfy® I/O Satu remote control:
Choose the favored channel on your somfy® remote on which you want to program the heater. After this press the PROGRAM button.
To interconnect your somfy® remote please disconnect the power supply for 3 seconds from the heater and the SMARTBOX, connect them again for 8 seconds and disconnect them finally for 3 seconds. After this you can switch on the power supply regularly.
This is the standard procedure to integrate new somfy* modules. The SMARTBOX will now turn on for 3 to 5 seconds (both LED on the SMARTBOX will light up red)  and after max. 5 seconds it will turn off again.
Now the SMARTBOX was recognized from the Satu I/O remote control and it can be switched as follows:

  • Choose the programmed channel of the heater.
  • Press UP button shortly: the heater will power up at 100%.
  • Press DOWN button for long: the heater will switch down to 50%.
  • Press UP button for long: the heater will switch up again to 100%.
  • Press DOWN button shortly: the heater will switch off.

AUTO-OFF FEATURE

The SMARTBOX is equipped with an Auto-OFF feature (not available with somfy® I/O control unit).
This additional feature switches off the heater after a specific period of time.
As soon as the HEATSCOPE® heater is regulated via SMARTBOX and IR control unit (50% — 100%, 100% — 50%), the preprogrammed Auto-OFF feature resets to  zero. Now the timer function starts again.
Standard: Auto-OFF activated (4h)
To change the standard setting, click the DOWN button of the remote 5x with max. 1 sec. interval right after connecting the HEATSCOPE® and SMARTBOX with the  power supply.
After recognizing this command the blue LED will switch off and the two red LED will start blinking 3x slowly (1sec on, isec. off). After this the SMARTBOX is in setup  mode. The two red LED will show the actual setup of the Auto-Off feature. The blue LED will not light!
With the help of the UP/DOWN buttons of the remote you can change the setup easily.
To save the desired new setup, just press the ON/OFF button finally.

Upper LED Lower LED Auto-oFF feature
off off deactivated
off on 4 hours
on off 6 hours
on on 8 hours

If no button is pressed for more than 1 minute in the setup mode, the setup will be closed without any changes.
The setup mode can be reached only after connecting the HEATSCOPE® and the SMARTBOX with a power supply! After switching on the heater via remote, the setup  mode is only reachable after disconnecting the unit from the main power supply.

CARE, MAINTENANCE AND SERVICE

Before cleaning and maintaining your HEATSCOPE® SMARTBOX disconnect it from the power supply or, if buried cables are used, switch it off via the omni polar  switches. All surfaces should be cleaned using a damp cloth only.
Never use cleaning products containing alkaline substances such as sodium hydroxide or soap, surfactants or solvents such as alcohol. Use only a very soft cloth or a brush  for the reflector and the heating elements.
Changing the PCB is only permitted with original equipment and must only be carried out by an authority delegated by the manufacturer. Damage or defects caused by  improper handling or operation as well as defects caused by using nonoriginal parts or the use of accessories not recommended by the manufacturer are not covered by the warranty.

REMOVAL FROM SERVICE / DISPOSAL

When the unit reaches the end of its life, it must be removed from service by a specialist in accordance with the relevant regulations and steps must be taken to ensure that it  cannot be put into use again.
The unit must be disposed of professionally and in an environmentally friendly manner. The relevant legal regulations must be observed.

GUARANTEE AND WARRANTY

All HEATSCOPE® devices are guaranteed for 24 months. The warranty period begins with the date on which the new unit was purchased. Expendable parts or defects that  affect the usability of the unit only slightly are not covered by the guarantee. When making a guarantee claim, you must provide the original invoice showing the date of purchase and the unit model.

PROCESSING OF GUARANTEE CLAIMS

Please contact your dealer/distributor before returning the defective unit along with valid proof of purchase and a detailed description of the fault. Please note: Don‘t send in  any devices to the manufacturer without any former contact with your distributor or dealer. He will inform you about all following steps. The manufacturer will only accept  the unit, if it is returned with adequate transport packaging which protects it securely during transport.
The manufacturer will, at his own discretion, fulfil his warranty obligations by either repairing or exchanging the faulty unit or individual parts of the faulty unit. If a unit is  replaced, the shape and colour of the new unit may vary slightly from the original one. The guarantee period shall not be extended if the unit was replaced or repaired by the manufacturer.

WARRANTY EXCLUSIONS

Damage or defects caused by improper handling or operation as well as defects caused by using nonoriginal parts or the use of accessories not recommended by the manufacturer are not covered by the warranty.
The warranty does not cover damages caused by external influences such as fire, lightning or any transport damages. Liability for consequential damages to persons or  property is excluded.
If the serial number of the unit has been changed, removed or defaced, the warranty will be invalid.
All warranty claims shall be forfeited if the unit is opened, altered, modified, rebuilt or repaired by a person not authorized by the manufacturer.
The declaration of conformity (CE, WEEE, RoHS) is available upon request from the manufacturer.

CONTACT PARTNERS IN YOUR AREA

THE NORTHERN COUNTRIES
Denmark, Sweden, Norway, Finland, Iceland
Monic GmbH
Kramergasse 32
D-82054 Sauerlach-Lochhofen
Tel.: +49 8104 647090
Fax: +49 8104 647099
[email protected]
www.moonich.de
USA, CANADA, NORTH AMERICA
MAD Design USA
5875 Green Valley Circle, Suite 100
Culver City, CA 90230 USA
Tel.: + 1 (888) 590.3335
[email protected]
www.mad-usa.com

UK & Ireland
MAD Design UK Ltd
3rd Floor, 5 Lloyds Avenue
London EC3N 3AE UK
Tel.: +44 0333 444 0623
[email protected]
www.mad-uk.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HEATSCOPE User Manuals

Related Manuals