Heatscope Heaters Pure+ 3000W Electric Radiant Heater Instruction Manual

June 11, 2024
Heatscope Heaters

Heatscope logo

Heaters Pure+ 3000W Electric Radiant Heater

Heatscope Heaters Pure 3000W Electric Radiant Heater ORIGINAL INSTALLATION AND
INSTRUCTION MANUAL
Electric design carbon radiant heater for indoor and outdoor areas

SAFETY INFORMATION

HEATSCOPE® infrared heaters must be installed and executed only by an authorized expert / professional electrician.
All relevant local building and fire safety regulations must be observed.
wARNING: This unit is not equipped with an application to regulate the room temperature.
The heater must not be used in small rooms inhabited by people who cannot leave the room unaided, unless constant supervision is ensured.
Be careful when operating the unit. Children younger than 3 years must be kept away, unless they are overseen all the time. Children older than 3 years and younger than 8  years are allowed to switch on and off the unit, if they are overseen, or if they were instructed how to use the unit safely and have received instructions how to operate/use  the unit, assumed the unit is installed properly.
CAUTION: Some parts of the unit get very hot and may cause burns! high cautiousness is imperative, if children or persons with reduced physical, sensory or mental abilities  or lack of experience and/or knowledge. are present in the room.
Children older than 3 years and younger than 8 years are not allowed to connect the plug, to control the unit, to clean the unit and/or to maintain the unit.
Children older than 8 years and persons with reduced physical, sensory or mental abilities or lack of experience and/or knowledge can use this unit, if they are overseen, or if  they were instructed how to use the unit safely and have received instructions how to operate/ use the unit and which endangerments may result during the use of the unit.  Children must not be playing with the unit. Cleaning and maintenance must not be done by children, unless they are supervised by a person responsible for their safety.
The unit must never be used unattended. Children must be supervised at all times to ensure that they do not play with the unit, switch it on unintentionally or adjust it.

  1. Please check that your HEATSCOPE® radiant heater and accessories are com plete and not damaged. If the housing or reflector is deformed/damaged or the heating element is broken, do not use the HEATSCOPE® unit. Please contact the vendor or the manufacturer. The cable must not be crushed, squeezed or damaged. If the unit or accessories show signs of defects, cracking, breakage or other damage or if the industrial glass ceramics screen is damaged, discontinue use and have them repaired. In this case, disconnect the unit from the power supply, return it to the manufacturer or dispose of it. The unit should be labelled accordingly to prevent it being reconnected.

  2. For installation use only the supplied accessories or original accessories approved by the manufacturer. The power cable or other components of the HEATSCOPE® radiant heater may only be replaced by a professional servicing company enlisted by the manufacturer.
    The supply cable must be connected generally in a commercially available wet room distribution box with IP65 protection class acc. to IEC or UL / CSA (not within the  scope of supply).

  3. The HEATSCOPE ® is protected against splashing water. It has an IP65 protection class for the PURE and IP25 for the NEXT and PURE+.

  4. As soon as the unit is connected to a power source and switched on using an „ON/OFF“ switch or other operating component, it takes a maximum of 15-30 seconds until it reaches its operating temperature.

  5. CAUTION: Risk of burns! The front screen (approx. 300°C) and protective fin front (approx. 400°C) gets very hot when the unit is operating. Do not cover either part of the front or the entire front of the radiant heater. Do not touch any part of the HEATSCOPE ® during operation and up to 30 minutes after switching it off.

  6. For your own safety, never dry textiles or other materials using the HEATSCOPE ® . Covering the radiant heater may result in a fire! Always maintain a distance from the heating surface of the HEATSCOPE ® of at least 150 cm from textiles, cloth and other easy inflamma- ble soft materials.

  7. Ensure that cables, furniture, flammable materials or other objects do not come into contact with the surface of the radiant heater and never cover the unit. Under no circumstances should the unit be covered or enclosed with insulating or similar materials. Adequate ventilation surrounding the heater must be ensured at any time. Ledgers, beams and rafters must not be cut into or grooved to install the infrared heater. When installing the HEATSCOPE ® radiant heater, ensure that the lower edge of the unit is at least 180 cm from the ground and the safety clearances from the wall and ceiling set out in this manual are maintained.

  8. Disconnect the radiant heater from the power supply by loosening and pulling off the plug of the devices’ power cord before cleaning, changing the angle of the corridor or changing the frontless/front grid. Wait until the heating elements stop glowing and the housing noticeably cooled down.

  9. The HEATSCOPE ® features an omni polar „ON/OFF“ switch. The unit can be controlled manually using an selector switch on the unit itself. The unit must be connected to a residual current circuit breaker and a fuse on the installation side.

  10. The unit must only be used with an approved isolating system, which must be built in the existing electrical installation acc. to the facility regulations. The heater comes as standard with a separate open-ended cable for connection purposes.

  11. The power cable or buried cable with omni polar switch may only be replaced by a professional specialist electrical company enlisted or approved by the manufacturer. Heating elements, other components or parts of the housing (exception: change of frontless/ front grid) may only be replaced by a service organization enlisted by the manufacturer. If you yourself or someone enlisted by you carries out repairs, they will not be covered by the guarantee. Improper repairs and incorrect installation or operation shall invalidate the guarantee immediately.

  12. If the heater was installed inappropriately or was connected homogeneously with the local electrical supply cable, high transfer resistances may occur, which lead to overheating of the device. If overheating of a carbon heating element occur due to interlinkage of mounting and installation mistakes, the carbon filaments inside of the quarz tubes will fuse and safely disconnect the current flow. Even after a mechanical break of the quartz tubes, the carbon heating spirals will not work any longer. Besides the glass ceramic, high temperature resistant front screen of the heaters provide best protection of the installed carbon heating elements. If a system malfunction inside the device causes the shut down, the heater must be repaired by a professional technician; please contact your dealer immediately. If a wrong cable connection causes the shut down, this has to be checked and fixed through a professional electrician on the spot. Installation and connecting regulations with tested and approved luster terminals are part of the delivered equipment.

  13. The radiant heater must not be installed directly below a power source/socket. The sides of the unit must be at least 20 cm from the nearest power source. Sockets/power sources must be freely accessible at all times and comply with the following specifications: 220–240 V AC ~, 50/60 Hz, 16 A fuse. No other loads may be connected to this power source.

  14. The radiant heater must not be installed in or in close vicinity to bathtubs, showers or pools, nor in rooms where there is permanent high humidity (DIN VDE 0100-701). The distance to the bathtub or shower must be at least 100 cm and the distance to the pool at least 200 cm. A person standing in the bathtub, shower or pool should never reach the switch or controller of the heater. If the HEATSCOPE ® is installed in such an environment with high humidity, the switches or other operating components must be positioned in such a way that they cannot be touched by persons who are in direct contact with water. When a radiant heater is installed in a bathroom, the CE standard requires that at least one heating element visibly „glows“ as soon as the unit is switched on.

  15. The heater must not be installed nor operated in environments containing chlorine (like inside pool areas) or salt (like near the coast).

  16. Disconnecting the HEATSCOPE ® from the power source by loosening and taking off the plug from the device is obligatory before cleaning or changing the front grid/frontless. Wait until the heating elements stopped glowing and the housing noticeably cooled down. Wait at least 30 minutes after the last use before you take any action.
    The surfaces can be cleaned with a damp cloth only. Never use cleaning products containing alkaline substances such as sodium hydroxide or soap, surfactants or  solvents such as alcohol. Use only a very soft cloth or a brush for the reflector or the heating elements.

  17. Always remember to switch off the unit after use.

ELECTRICAL CONNECTION

Heatscope Heaters Pure 3000W Electric Radiant Heater -
fig

MANUAL CONTROL

MOUNTING

Heatscope Heaters Pure 3000W Electric Radiant Heater - fig
3Heatscope Heaters Pure 3000W
Electric Radiant Heater - fig 4Heatscope Heaters Pure 3000W Electric Radiant Heater - fig
5

MINIMUM DISTANCES

Heatscope Heaters Pure 3000W Electric Radiant Heater - fig
6Heatscope Heaters Pure 3000W
Electric Radiant Heater - fig 7Heatscope Heaters Pure 3000W Electric Radiant Heater - fig
8

MINIMUM DISTANCES [GLASS]

Heatscope Heaters Pure 3000W Electric Radiant Heater - fig
9

Heatscope Heaters Pure 3000W Electric Radiant Heater - fig
10Heatscope Heaters Pure 3000W
Electric Radiant Heater - fig 11

HEATSCOPE® infrared heaters are producing high energy efficient heat based on IR fast midwave up to efficient IR longwave technology.
Eye, skin and organism harming IR short waves are not produced by HEATSCOPE® carbon heating elements in any way. Designed for private and commercial use for wall  and ceiling mounting in indoor and outdoor areas, HEATSCOPE® carbon radiant heaters produce heat within seconds wherever it is needed.
The infrared radiant heater allows you to transport heat over a distance of up to 3 metres, ideally in a specific direction.
Before installing the unit, please read this instruction manual carefully. Follow the information given to avoid endangering yourself, your family, your friends and your  acquaintances. If you have any questions, contact the vendor or manufacturer.
Please keep this instruction manual in a safe place. Pass on the manual to any subsequent owner of the HEATSCOPE® unit and ensure that any supplements received are  included along with it.
This manual is also available online: www.heatscope.com
(https://www.heatscope.com/wp-content/uploads/ HEATSCOPE-PURE-NEXT-Manual- Heater-INT.pdf) Prior to installation, ensure that the operating voltage matches  the one specified on the rating plate of the HEATSCOPE® unit!
This instruction manual is intended solely for the standard products available. The technical data, installation requirements and dimensions of custom made, special versions may differ.

UNPACKING THE UNIT / PACKAGING
Unpack the unit and the accessories carefully. When opening the packaging, do not use sharp objects that could damage the unit.
This product comes supplied in environmentally friendly packaging. All HEATSCOPE® packaging that comes into circulation either directly or via the trade is certified in  accordance with §6 of the German Packaging Directive. As a result, all HEATSCOPE® packaging can be disposed of in an environmentally friendly manner in collection  containers for packaging materials. All legal regulations must be observed here. Further information is available from the manufacturer.
Care information! important! Clean the unit with a damp cloth before using it for the first time. Do not use cleaning products containing alkaline substances such as sodium  hydroxide or soap, surfactants or solvents/alcohol.
correct screws (supplied) for the surface.
Please bear in mind that you only need one fixing bracket to fix your unit safely. Please refer to the minimum installation dimensions for the unit (cf. ,spacings*).
Acc. to EU 2015/1188 ecodesign directive for energy-related products the application of a thermostat with a room sensor, weekday control system and window opening  detection is mandatory, when installation a heating unit indoors. This is possible with this HEATSCOPE® type. In combination with the optional available thermostat  Derive™ Smart this heater of this series fulfills the conformity of the eco-design directive.
HEATSCOPE® heaters are basically made for outdoor use – and in most cases they are used outdoors finally. Due to this they are factory-set delivered without any  thermostat control system acc. to EU 2015/1188 ecodesign directive. This is consequent, reasonable and will economies valuable resource’s. Many times a separate  temperature system / thermostat acc. to ecodesign directive is already installed and the heaters should be fit in this system. In this case the customer or the assigned installer is  responsible to accomplish the EU standards of the ecodesign directive.

OPERATION, INSTALLATION INSTRUCTIONS AND MIN. DISTANCES
Once you have installed the unit, you can use it for the first time.
The HEATSCOPE® features two omni polar ,ON/OFF* switches. You can control the radiant heater manually using these selector switches on the unit itself.
The unit must be connected to a residual current circuit breaker and a fuse! Install the unit in any indoor or outdoor areas. The HEATSCOPE? is protected against splashing  water and dust. It has an IP65 protection class for the PURE and IP25 for the NEXT and PURET.
CAUTION: The mounting of the heater on the wall and on the ceiling as well as in glass houses and conservatories has professionally to be accomplished solely according to  the mounting regulations. Specified safety distances given are min. values and may deviate from the local building and fire safety regulations. The safety distances as well as the  local building and fire safety regulations must be complied with at all times, leave improper stated installation settings undone at any time. Deviant installation settings require the technical approval of the manufacturer. In the case of a deviant installation setting without approval of the manufacturer danger for people and environment may  occur. Warranty and guarantee expires for all heaters, which are not installed according to this operation and installation manual!
Other protective spacings may need to be taken in accordance with local fire safety regulations, e.g. for installation on combustible surfaces.
All cables must be positioned so that they cannot come into contact with the surface of the radiant heater at any time. The radiant heater must not be installed directly below  a power socket. The sides of the HEATSCOPE® must be at least 20 cm from any power sockets.

REMOVAL FROM SERVICE / DISPOSAL

When the unit reaches the end of its life, it must be removed from service by a specialist in accordance with the relevant regulations and steps must be taken to ensure that it  cannot be put into use again.
The unit must be disposed of professionally and in an environmentally friendly manner. The relevant legal regulations must be observed.

GUARANTEE AND WARRANTY

The HEATSCOPE® is guaranteed for 24 months. The warranty period begins with the date on which the new unit was purchased. Expendable parts or defects that affect  the usability of the unit only slightly are not covered by the guarantee. When making a guarantee claim, you must provide the original invoice showing the date of purchase and the unit model.

PROCESSING OF GUARANTEE CLAIMS

Please contact your dealer/distributor before returning the defective unit along with valid proof of purchase and a detailed description of the fault. Please note: Don‘t send in  any devices to the manufacturer without any former contact with your distributor or dealer. He will inform you about all following steps. The manufacturer will only accept  the unit, if it is returned with adequate transport packaging which protects it securely during transport.
The manufacturer will, at his own discretion, fulfil his warranty obligations by either repairing or exchanging the faulty unit or individual parts of the faulty unit. If a unit is  replaced, the shape and colour of the new unit may vary slightly from the original one. The original date of purchase shall determine when the guarantee period begins. The  guarantee period shall not be extended if the unit was replaced or repaired by the manufacturer.

WARRANTY EXCLUSIONS

Damage or defects caused by improper handling or operation as well as defects caused by using nonoriginal parts or the use of accessories not recommended by the  manufacturer are not covered by the warranty.
The warranty does not cover damages caused by external influences such as fire, lightning or any transport damages. Liability for consequential damages to persons or property is excluded.

TECHNICAL DATA| Healthscope NEXT, PURE with grid| Healthscope PURE, PURE with glass
---|---|---
Operating voltage| 220-240 V AC -, 50/60 Hz| 220-240V AC -, 50/60 Hz
Power at 240 V AC-| 3200 W
Current| 13.33 A
Power Cord| 1.1 m / 4 x 1.5 mm2
Max. surface temperature / front| 400 °C| 300 °C
Max. housing temperature| 120 °C| 120 °C
Filament temperature| 1100-1300 °C
Heating impact in| 15 Sek.| 30 Sek.
Max. visible light| 600 lumen| 300-400 lumen
Installation height| min. 1.8 m / max. 3.0 m| min. 1.8 m / max. 2.7 m
IP protection class| IP 25| IP 65
Manual control| ON/OFF + 100%, 50%
Remote control (SMARTBOX)| ON/OFF + 100%, 50%
Measurements| 1044 x 166 x 87 mm
Weight| 6.5 kg| 7.5 kg

No action is needed to switch the device between 50Hz and 60Hz.
The product will adapt itself for both 50Hz and 60Hz.

Mandatory product information acc. to EU 2015/1188 ecodesign directive
The HEATSCOPE® heater (PE/NM/PH series) is switched and controlled only by the ecodesign certified thermostat Derive™ Smart, which is observing the room temperature (RT) and which is also able to note, if the windows are open or not.
Once activated the training mode will reach the programmed ambient temperature in the weekday routine at any set point of time.

Modell mhS-PE3000/mhS-Nm3000/mhS-Ph3000
HEAT OUTPUT
Rated heat output Pnom  in H 3200 (@ 240 V AC)
Rated heat output Pnom  in Kw 3.2
Min. heat output PMing  in kW 1.6
Max. cont. heat output Pmax,c  in kW 3.2

Auxiliary Power Consumption

At rated heat output elm ax  in Kw N.A.
At rated heat output elfin  in kW N.A.
At standby ells’  in kW N.A.

Specification

DEVIreg™ Smart

Type of heat Output / Rooms Temperature Control|
---|---
one step heat output, no room temperature control| No
tow or more manually adjustable steps, no room temperature control| No
room temperature control with mechanical thermostat| No
with electronical room temperature control| No
electronical room temperature control and daytime control system| No
electronical room temperature control and daytime control system| Yes

FURTHER CONTROL OPTIONS

room temperature control and attendance detection No
room temperature control with open window detection Yes
incl. remote control option Yes
incl. adaptive regulation of heating inception No
incl operating time limitation Yes
incl. black orb sensor No

Manufacturer:
BF-Consulting GmbH · Sudetenstr. 92 · D-82538 Geretsried/Germany info@bf- consult.de · www.bf-consult.de
licensed by:
MHS Munich Home Systems GmbH · Kramergasse 32 · D-82054 Auerbach/Germany [email protected] · www.heatscope.com
HEATSCOPE® heaters of the PE/NM/PH series fulfill the standards of the EU 2015/1188 ecodesign directive, when room temperature control is accomplished by the  optional available DeVere™ Smart thermostat.

Heatscope Heaters Pure 3000W Electric Radiant Heater - fig
13

ThE NORThERN COUNTRIES
Denmark, Sweden, Norway, Finland, Iceland
mOONICh Gmbh
Kramergasse 32
D-82054 Sauerlach-Lochhofen
Tel.: +49 8104 647090
Fax: +49 8104 647099
[email protected]
www.moonich.de

UK & Ireland
mAD Design UK Ltd
3rd Floor, 5 Lloyds Avenue
London EC3N 3AE UK
Tel.: +44 0333 444 0623
[email protected]
www.mad-uk.com

USA, CANADA, NORTh AmERICA
mAD Design USA
5875 Green Valley Circle, Suite 100
Culver City, CA 90230 USA
Tel.: + 1 (888) 590.3335
[email protected]
www.mad-usa.com

References

Read User Manual Online (PDF format)