RAK M310, M320 4G and 5G Radios User Manual

June 9, 2024
RAK

RAK M310, M320 4G and 5G Radios

M310, M320 4G and 5G Radios

Simple configuration guide for developers, private LTE&5G and some other usage
NOTE: This is a beta version document, contact us for more details.

Installation

Attention: Good GPS signal is required to activate and run 4G&5G radios.

  • Take out device from package, assemble device with pedestal.
    M310, M320 4G and 5G Radios

  • Put device close to window.
    Installation

  • Connect GPS antenna to the device, and put out the antenna outside the window to get a good GPS signal.
    Installation

  • Connect the PoE power source to the WAN/PoE port on the device to power it up.

Hardware specifications

  M310 M320
Network LTE
5G NR  
LoRaWAN®
Wi-Fi 6  
FCC ID 2AF6B-M310 2AF6B-M320
Contain FCC ID 2ABCB-RPICM4 2ABCB-RPICM4
Frequency band B48

(3550 to 3700 MHz)

| B48, n48, n78 (3550 to 3700 MHz)
4G/5G Core| ✓| ✓
PoE (802.3bt)| ✓| ✓
Computing| Quad core Cortex-A72 (ARM v8)| Quad core Cortex-A72 (ARM v8)
RAM| 4GB| 4GB
eMMC| 32G| 32G
Ethernet| 2.5G| 2.5G
Tx power| 2 x 24 dBm/port| 2 x 24 dBm/port
Power consumption| 30W (MAX)| 55W (MAX)
USB| Type-C USB3.0
Button| One pairing button
LED| Tricolor LED (top side)
Antenna| LTE| Internal antenna
5G NR| Internal antenna
LoRaWAN®| Internal antenna (supporting switch to external antenna)
GPS| Internal antenna (supporting switch to external antenna)
Dimension| 300 mm x 311.5 mm x 79 mm
Ingress protection| IP30
Enclosure material| Plastics
Weight| 4.2 kg
Operating temperature| -5°C to 45˚C
Storage temperature| -10°C to 50°C
Humidity| 5% to 95% RH
Atmospheric pressure| 70 kPa to 106 kPa

Configuration

There’s 4 major scenario you can use RAK M310/M320 device for, customers are required to configure the device according to their usage.

  • Take RAK M310/M320 as a pure 4G and/or 5G radio, connect to external customer’s own EPC/5GC. Please refer to chapter Configuration with External EPC/5GC
    Configuration

  • Take RAK M310/M320 as an All in One device, running with RAK’s open source Magma AGW inside. Please refer to chapter Configuration with Magma inside
    Configuration

  • Take RAK M310/M320 as an All in One device, runing with RAK’s open source Open5GS inside. Please refer to chapter Configuration with Open5GS inside
    Configuration

  • Take RAK M310/M320 as an All in One device, with customers own EPC/5GC on open hardware CM4. Please refer to chapter Configuration with  Customer’s EPC/5GC inside
    Configuration

Configuration with External EPC/5GC

This chapter will describe basic configuration to connect eNodeB and/or gNodeB to customer’s own EPC and/or 5GC, after these configuration, the eNodeB and/or gNodeB start serving. For more configuration details, please refer to MNTD. 5G LTE Configuration Guide and MNTD. 5G NR Configuration Guide

Here’s the basic steps configuring RAK M310/M320 with customer’s own EPC/5GC:

  • Step 1: Prepare your PC or laptop’s network to access to RAK M310/M320’s
    local web

  • Step 2: Login to eNodeB and/or gNodeB’s local web

  • Step 3: Configure eNodeB’s S1 and/or gNodeB’s N2 interface network
    according to your requirement

  • Step 4: Configure eNodeB and/or gNodeB’s PLMN, TAC, Cell ID, MME and/or AMF IP address, etc

  • Step 5: Configure NTP server for eNodeB and/or gNodeB.

  • Step 6: Reboot eNodeB and/or gNodeB to use new configuration

Please plan parameters below before configuration:

I te m Parameter Description
IP Address OAM IP OAM uses a separate IP address to access to local web,

192.168.150.123/24, etc.
 | Core IP| MME IP for 4G eNodeB, AMF IP for 5G gNodeB, planned by the customer.
Cell Parameters| PLMN| Planned by the customer.
 | TAC| Planned by the customer.
 | Cell ID| Planned by the customer.
NTP Server| NTP Server Address| Planned by the customer. NOTE: NTP is required to activate and run 4G eNodeB and 5G gNodeB.

Step 1 Prepare Network to Access to Local Web

RAK M310&M320’s 4G eNodeB configured with a static IP address 192.168.150.1/24 to serve for local web access.
RAK M320’s 5G gNodeB configured with a static IP address 192.168.150.7/24 to serve for local web access.
Customers are require to configure their PC or laptop’s ethernet port to subnet 192.168.150.0/24 to access eNodeB or gNodeB’s local web managment, bridged by a router/switch or connected directly. The network connection may looks like this:
Configuration with External EPC/5GC

Step 2 Login to Local Web

RAK M310&M320’s eNodeB local web serving URL is: https://192.168.150.1 with default user name admin and default password admin.
RAK M320’s gNodeB local web serving URL is http://192.168.150.7 with default user name new_user and default password gNB@2014 Here we recommend using Chrome browser to achieve the best effect.
Configuration with External EPC/5GC

Step 3 Configure eNodeB’s S1 and or gNodeB’s N2 Interface

Mostly the eNodeB‘s S1 and/or gNodeB’s N2 interface are required to have a static IP addresse to connect to customer’s EPC and/or 5GC. Dynamic IP address allocated by DHCP is also supported, all depend on customers network requirement.

  • Configure eNodeB’s S1 Interface with Static IP
    Login to eNodeB’s local web via https://192.168.150.1, navigate to Network > WAN/LAN page, click the edit button, and select Static IP in IP Access Mode, after that edit the static IP address, netmask and gateway for the eNodeB’s S1 port. Then click OK and Save button to save the configuration.Configuration
with External EPC/5GC

  • Configure eNodeB’s S1 Interface with Dynamic IP
    Login to eNodeB’s local web via https://192.168.150.1, navigate to Network > WAN/LAN page, click the edit button, and select DHCP in IP Access Mode to enable DHCP client on the eNodeB’s WAN port. Then click OK and Save button to save the configuration.
    Configuration with External EPC/5GC

  • Configure gNodeB’s N2 Interface with Static IP
    Login to gNodeB’s local web via http://192.168.150.7, navigate to Network > WAN/LAN page, lick Open button to expand the configuration table, then click the edit button, and select Static IP in Addressing Mode field, Ng in Port Type field, after that edit the static IP address, netmask and gateway for the gNodeB’s N2 port. Then click OK and Save button to save the configuration.
    Configuration with External EPC/5GC

  • Configure gNodeB’s N2 Interface with Dynamic IP
    Login to gNodeB’s local web via http://192.168.150.7, navigate to Network > WAN/LAN page, click Open button to expand the configuration table, then click Edit button to pop up edit window, and select DHCP in Addressing Type field, Ng in Port Type field, then click OK and Save button to save configuration.
    Configuration with External EPC/5GC
    Step 4 Configure PLMN, TAC, Cell ID and Core Address, etc
    Customers are required to configure eNodeB and/or gNodeB with planned TAC,
    PLMN, MME and/or AMF IP address to connect to customers own EPC/5GC. These parameters are depend on customer’s network requiremens.

  • Configure eNodeB’s PLMN, TAC, Cell ID and MME IP, etc.
    Login to eNodeB’s local web via https://192.168.150.1, navigate to Quick Setting page, configure the PLMN, TAC, Cell ID, Country code and MME IP, and turn on the RF, and then click Save button to save the configuration.
    Configuration with External EPC/5GC
    Configuration with External EPC/5GC

  • Configure gNodeB’s PLMN, TAC and Cell ID, etc
    Login to gNodeB’s local web via http://192.168.150.7, navigate to NR Setting > PLMN page, click Edit button to edit Cell ID and TAC, and then the PLMN list will show up, click the PLMN List’s Edit button to edit the PLMN.
    Configuration with External EPC/5GC

  • Configure gNodeB’s AMF IP Address
    Login to gNodeB’s local web via http://192.168.150.7, navigate to NR Setting > Advanced page, click + CU to expand CU tables, scroll down to the AMF IP table, click + button to add AMF IP for PLMN, then click OK and Save button to save configuration.
    Configuration with External EPC/5GC
    Step 5 Configure NTP Server
    NTP is required to activate and run 4G eNodeB and 5G gNodeB. Without any reachable NTP servers. the eNodeB and/or gNodeB cannot activated successful.

  • Configure eNodeB’s NTP server address
    Login to eNodeB’s local web via https://192.168.150.1, navigate to System > NTP page, turn on the NTP Servers button and edit the NTP servers IP addresses and Port, then click Save button to save configuration.
    Configuration with External EPC/5GC

  • Configure gNodeB’s NTP server address
    Login to gNodeB’s local web via http://192.168.150.7, navigate to System > NTP page, select ON in Enable field and edit the NTP servers IP addresses, then click Save button to save configuration.
    Configuration with External EPC/5GC
    Step 5 Reboot eNodeB and/or gNodeB to use new configuration

  • Reboot eNodeB
    Configuration with External EPC/5GC

  • Reboot gNodeB
    Configuration with External EPC/5GC

Configuration with Magma inside

RAK M310/M320 has a built-in open source Magma AGW installation package inside, customers can login and install the package manually with following steps:

  • Step 1 Prepare network to access to M310/M320 CM4 module
  • Step 2 SSH login to M310/M320 CM4 module
  • Step 3 Install AGW with built-in pacakage
  • Step 4 Reboot to run AGW
Step 1 & Step 2

Please refer to Chapter Login to CM4 Module to prepare network and SSH login to CM4

Step 3 Install Built-in Magma AGW Package

Note: The package name would be with prefix “upgrade_agw”, the specific package name would be different for different release.

magma$ sudo /opt/magma/upgrade_agw_xxx

Step 4 Reboot the Device

After Magma AGW installed, the eNodeB and/or gNodeB start serving automatically with default parameters as below:

Parameter Value
PLMN 00101
TAC 1
Cell ID 1

Note the CM4’s static IP address will changed automatically to 192.168.151.100/24, use this IP address to SSH login to CM4 for more configurations.

For more Magma AGW configuration details, please refer to MNTD. Magma AGW Configuration Guide

Configuration with Open5GS inside

RAK M310/M320 has a built-in open source Open5GS installation package inside, customers can login and install the package manually with following steps:

  • Step 1 Prepare network to access to M310/M320 CM4 module
  • Step 2 SSH login to M310/M320 CM4 module
  • Step 3 Install Open5GS with built-in pacakage
  • Step 4 Reboot to run AGW
Step 1 & Step 2

Please refer to Chapter Login to CM4 Module to prepare network and SSH login to CM4

Step 3 Install Built-in Open5GS Package

Note: The package name would be with prefix “install_open5gs”, the specific package name would be different for different release.

magma$ sudo /opt/open5gs/install_open5gs_xxx

Step 4 Reboot the Device

After Open5GS installed, the eNodeB and/or gNodeB start serving automatically with default parameters as below:

Parameter Value
PLMN 00101
TAC 1
Cell ID 1

Note the CM4’s static IP address will changed automatically to 192.168.151.100/24, use this IP address to SSH login to CM4 for more configurations.

For more Open5GS configuration details, please refer to MNTD. Open5GS
Configuration Guide

Configuration with Customer’s EPC/5GC inside

For customers who want to install their own EPC or 5GC onto RAK M310/M320’s CM4 Module, please comfirm that the EPC or 5GC is compatible to Raspberry CM4.

There’s also 4 major steps to install customer’s EPC or 5GC onto RAK M310/M320’s CM4 Module:

  • Step 1 Prepare network to access to M310/M320 CM4 module
  • Step 2 SSH login to M310/M320 CM4 module
  • Step 3 Install with customer’s pre-built EPC or 5GC package
  • Step 4 Reboot to run AGW

Login to CM4 Module

RAK M310&M320 has an Raspberry CM4 that’s open to customers, you can login to the CM4 module to install built-in packages or your own application, depends on your requirements. To install packages on CM4, here’s some basic steps to operate:

  • Step 1 Prepare network to access to M310/M320 CM4 module
  • Step 2 SSH login to M310/M320 CM4 module
Step 1 Prepare Network to Access to CM4

RAK M310&M320’s CM4 module configured with a static IP address 192.168.150.100/24 to serve local SSH access.

Customers are require to configure their PC or laptop’s ethernet port to subnet 192.168.150.0/24 to SSH access to CM4 , bridged by a router/switch or connected directly. The network connection may looks like this:
Login to CM4 Module

NOTE: If the device had installed with the built-in Magma AGW or Open5GS, the CM4’s static IP address have changed to 192.168.151.100/24, then customers need to configure the PC or laptop’s IP to 192.168.151.0/24 to access to CM4.

Step 2 SSH login to CM4

RAK M310&M320’s AGW can be SSH to using commands as below with default password rakwireless:
customer$ ssh magma@192.168.150.100

Disable 4G on M320

RAK M320 integrated with a 4G eNodeB and a 5G gNodeB, for customers who wants 5G gNodeB only, please login to eNodeB’s local web via https://192.168.150.1, navigate to Quick Setting page, configure the RF field to Off, and then click Save button to save the configuration.
Disable 4G on M320

Mobile Phone Access to Network

For customers using thier own EPC or 5GC, you should insert SIM cards managed by youself to the mobile phones and other end devices, wether configure the phones or devices to access to network depends on your requirements.

For customers using RAK M310/M320’s built-in Magma AGW or Open5GS, before mobile phones or other devices acess to network, customers are required to insert the SIM cards provide by RAK into mobile phones or other end devices, and add a APN named with internet, and select the network 00101 at the first access.

FCC Compliance

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Warning:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Read User Manual Online (PDF format)