SOYAL AR-PB-323 Don’t Disturb Switch User Guide
- June 9, 2024
- SOYAL
Table of Contents
AR-PB-321/AR-PB-323
Don’t Disturb Switch (outdoor/indoor)
Contents
Installation
Turning back the housing, prying two tenons open as marked in circle. Please take off B. carefully to prevent cables broken by forced pull.
Loosening connector from socket of A. And then, screwing cables.
Using a screwdriver, screw the B. to the wall.
Connect cable back and push Part A. to Part B..
Specification
AR-PB-321
Input| V+| 9-16VDC
V-| OV
DO NOT Disturb LED| Low Active / 20mA Max
Clean up LED| Low Active / 20mA Max
Output| Bell Relay| Form A Clean Contact
30VDC/7A, 250VA/7A
AR-PB-323
Input| V+| 9-16VDC
V-| OV
DO NOT Disturb LED| Touch Panel
Clean up LED| Touch Panel
Output| DO Not Disturb| LED Driver| Open Collect 12VDC/50mA Max
Relay| Form A Clean Contact 24VDC/2A, 125VAC/1A
Clean up| LED Driver| Open Collect 12VDC/50mA Max
Relay| Form A Clean Contact 24VDC/2A, 125VAC/1A
Connector Setting
AR-PB-321 | AR-PB-323 |
---|---|
GND | 1 |
VCC | 2 |
COM | 3 |
Relay
NC1| 4| N.C. of Door Bell Relay| NO2| 4| N.O. of Clean up Relay
NO1| 5| N.O. of Door Bell Relay| NO1| 5| N.O. of DO NOT Disturb Relay
LED1| 6| LED signal of Clean up| LED1| 6| LED signal of Clean up
LEDO| 7| LED signal of DO NOT Disturb| LEDO| 7| LED signal of DO NOT Disturb
AR-PB-323 Jumper Setting
DO NOT Disturb
| Remain Clean up fuction after “DO NOT Disturb”.
| Disable clean up fuction after pressed “DO NOT Disturb”.
Wiring Diagram
The sensitivity of button will be affected by environment, and touch IC has
function of auto-proofread sensitivity.
If you have a bad contacting on button, please release the power and connect
it again.
Read User Manual Online (PDF format)