WARNING
(Risk of fire)

| This appliance contains R290 propane gas. This appliance uses a flammable refrigerant gas. If the refrigerant gas leaks and comes into contact with a source of heat or ignition, it generates harmful gases and can cause a fire.
| Strictly follow the instructions in this manual regarding operation and maintenance.
| Before using the appliance, carefully read the whole instruction manual.
| Do not install, operate, or store the appliance in a space smaller than 4 m2.

SAFETY INSTRUCTIONS

Please read these instructions carefully before using the appliance for the first time and keep them for future reference.

  • Use that does not comply with the instructions releases FLAMA from all responsibilities.
  • After transport or cleaning and maintenance, let the unit rest for 12 hours before connecting the unit to the power supply.
  • Check that the power supply voltage of the installation corresponds to that stated on the rating plate of the appliance.
  • This appliance must be connected to an earthed socket.
  • This appliance is intended to be used by specialists or trained shop users. In light industry and on farms, or for commercial use by lay people.
  • Do not install this appliance near sources of heat, water, windows or doors leading to the outside.
  • This appliance is designed to dehumidify areas with excess moisture.
  • As with any appliance, its use by children must be properly supervised.
  • This appliance can be used by children aged 8 years and over and by persons with limited physical, sensory or mental capabilities or lack of experience and knowledge, if they are supervised or have received instructions concerning use of the appliance in a safe way and understand the risks involved.
  • Children must not play with the appliance.
  • Cleaning and user maintenance must not be carried out by children without supervision.
  • The appliance must be installed in compliance with national installation regulations.
  • Do not use the appliance in a potentially explosive environment containing combustible liquids, gases or dust. Do not use paint, cleaning sprays, anti-insect sprays or the like near the appliance.
  • Do not pull the plug out of the socket by pulling the power cord.
  • Avoid using “T” sockets or extension cords.
  • Disconnect the appliance from the power supply after each use.
  • Unplug the appliance from the electrical socket whenever cleaning or maintenance is carried out.
  • When switching off the appliance, always wait at least 3 minutes before switching it on again.
  • Clean the air filter at least once a week.
  • This appliance must be transported in an upright position. Always empty the water tank before transporting.
  • It is important to leave a surrounding space of approximately 50 cm for good air circulation, away from combustible objects.
  • Do not use the appliance if it is not working properly or if it is damaged in any way.
  • Any intervention other than cleaning must be carried out at an Authorized Flama Technical Assistance Service.
  • Do not attempt to replace the power cord or plug, as this is a dangerous operation. If the power cord is damaged, it must be replaced by Authorized Flama Technical
  • Assistance Service or similarly qualified personnel.
  • The weighted sound pressure level is less than 70 dB.

This product complies with the Electromagnetic Compatibility and Low Voltage Directives.
This instruction manual is also available in PDF format atwww.flama.pt.

SAFETY ADVICE REGARDING THE R290 REFRIGERANT

  • Carefully read all warnings.
  • This appliance contains 45 g of R290 refrigerant gas.
  • R290 is a gas that is in compliance with
  • European environmental directives. Do not puncture any of the refrigeration circuit components.
  • For the defrosting process and to clean the appliance, do not use any instruments other than those recommended in this manual (“Cleaning and maintenance”).
  • The appliance must be placed in an environment free from continuously operating sources of ignition (for example: open flames, gas or electric devices in operation).
  • Do not puncture and do not burn the appliance.
  • The refrigerant gases may be odorless.
  • The appliance should be installed, used, and stored in an environment larger than 4 m2.
  • If the appliance is installed, used, or stored in an unventilated space, prevent the pooling of any possible refrigerant leaks, as this carries a danger of fire or explosion if the refrigerant is ignited by electric heaters, ovens or other sources of ignition.
  • The appliance should be stored in a way that avoids mechanical damage.
  • Technicians who perform work on refrigeration circuits should hold appropriate certification, issued by a credentialed authority, attesting to their competence in handling refrigerants in accordance with a specific standard recognized by the trade associations.
  • Repair services should be performed based on the recommendations of the appliance manufacturer.
  • Maintenance and repair services requiring assistance from multiple qualified technicians should be done under the supervision of the person specialized in handling flammable refrigerants.

GENERAL INFORMATION

  • For optimal performance of your dehumidifier:
  • Place the dehumidifier on a solid and level surface in an area with at least 50 cm (20 in) of open space on all sides to allow for adequate air flow.
  • Do not place near a radiator or any other heat source.
  • Ensure that all windows are closed for maximum efficiency.
  • Ensure that the filter is kept clean. This prevents excess electricity consumption and ensures optimal efficiency.
  • To prevent noise and/or vibration, do not place the appliance on a soft or irregular surface while in operation.
  • To prevent damage, never insert any kind of rod or other soft or hard object into the structure of the appliance.
  • The capacity of the dehumidifier depends on the temperature and the humidity of the room.
  • At lower temperatures, less humidity will be removed.
  • If there is an interruption to the power supply, the dehumidifier will restart after 3 minutes (depending on the model).
  • This automatic interval period protects the compressor.

ATTENTION:
The dehumidifi er must be placed in a vertical position for at least 12 hours before use.
Do not attempt to replace the power cord or plug, as this is a dangerous operation.
Have them replaced immediately by a Flama-authorized technical assistance service or by similarly qualified technicians to prevent danger.

DESCRIPTION

  1. Control panel
  2. Indicator light
  3. Water tank
  4. Filter
  5. Plug for conti nuous drainage
  6. Handle
  7. Wheels
  8. STANDBY button (ON/OFF)
  9. MODE button
  10. TIMER button
  11. Humidity and ti mer control buttons
  12. Display
  13. LOCK button
  14. Filter REST/RESET button
  15. Fan control button

OPERATING INSTRUCTIONS

TURNING THE APPLIANCE ON AND OFF

Ensure that the water tank is in the correct position (after turning on the appliance for the first time, if the full tank indicator turns on, remove the tank and put it back in the correct position).
Make sure that the appliance is plugged into the wall outlet.
Turn off the appliance, unplugging it from the wall outlet.

INDICATOR LIGHT (2)

Ambient humidity <45% – blue light.
45≤ ambient humidity ≤65% – green light.
Ambient humidity >65% – red light.
If the display shows E0, E2, CL, CH, LO or HI, the light will turn red.

CONTROL PANEL

STANDBY button
Press the STANDBY button and the dehumidifier will begin to operate with an initial humidity setting of 60%, standard automatic mode and high fan mode.
Press the POWER butt on again and the dehumidifier will cease operation.

MODE button
Press the MODE button once to alternate between automatic mode and clothes drying mode; the corresponding indicator will light up.

Automatic mode
When the ambient humidity ≥ + 3% of the defined humidity, the fan will start and the compressor will start after 3 seconds.
When the ambient humidity is ≤ -3% of the defined humidity, the compressor will stop working and the fan will stop working after a delay of 30 seconds.
The fan speed and humidity settings can be adjusted in automatic mode.

Clothes drying mode
In this mode, the dehumidifier will optimize the fan speed and dehumidifying capacity to accelerate clothes drying. The standard humidity setting is 20% and the fan speed and humidity settings cannot be adjusted.

TIMER button
Press this button to define the timer function from 0-24 hours. The increments are of 1 hour. Each time the button is pressed, the time will increase by 1 hour and the corresponding time will be displayed on the screen. The default value of “00” cancels the timer function. The indicator will turn off.
After the timer is defined and concluded, the timer LED will stay lit during that period of time. After the time is up, the timer LED will turn off automatically.
While operating, set the time for the dehumidifier to turn off.
In rest mode, set the time for the humidifier to turn on.

Humidity and timer control buttons
Press these buttons to adjust (increase or decrease) the humidity and time.
To adjust the humidity, press once to increase or decrease by 5%.
To adjust the time, press once to increase or decrease by 1 hour.

LOCK button
Press the button for 3 seconds to activate the child lock function. The child lock indicator light will turn on. All buttons will be locked and non- operational.
Press the button again and the indicator light will turn off and the button will be deactivated.
Turning off the dehumidifier will automatically cancel the child lock function.

Filter REST/RESET button
Press the rest mode button and the indicator will light up and activate rest mode. Press the button again to turn off the function.
In rest mode, the fan speed will automatically change to low and, if no operation occurs within 10 seconds, except for the rest mode indicator light turning on, all the lights will turn off.
When the room humidity is ≤ 57%, the compressor will stop working and the fan will stop working 30 seconds later. When the ambient humidity is ≥ 63%, the fan will start and the compressor will start 3 seconds later. In this mode, the fan speed and humidity adjustment functions cannot be set.
In rest mode, the alarm will not sound when the water tank is full, but the full tank indicator light will turn on (red) as a reminder that the water tank is full and needs to be emptied.

Restarting the air filter
Press and hold the rest button for 3 seconds to restart the air filter. Once the dehumidifier has been in operation for 600 hours, the air filter indicator light will turn on as a reminder to clean the air filter and the dehumidifier will not work.
Proceed to clean the filter.
Press and hold the button for some time to restart the air filter.

Fan control button
The fan speed can only be adjusted in automatic mode.
Press this button to alternate between high and low fan speed. The corresponding fan speed indicator will turn on.

EMPTYING THE WATER TANK

When the water tank is full, the dehumidifier will emit an alert sound and the “full tank” light will turn on.
Press the STANDBY button to turn off the dehumidifier.
Pull on the water tank and simply slide it out of the body of the humidifier.
Empty the water down a drain or outside.
Clean the interior and exterior of the water tank.
Return the empty water tank to dehumidifier.
Press the POWER button to resume operation.
If the “full tank” button does not turn off, make sure that the water tank and float are correctly positioned.

Notice
Do not discard the water tank magnets and plastic rivets. Otherwise, the dehumidifier will not automatically stop working when the water tank is full, and the condensed water will overflow and damage the floor of the room it is in.
Make sure to clean the condensed water in the water tank before restarting operation of the dehumidifier.
If the water tank is dirty, rinse it with clean water. Avoid using detergents, chemical dust removers, diesel oil, benzene, thinners or other solvents. These will damage the water tank and cause leaks.
Return the empty water tank to dehumidifier.
Otherwise, the full tank indicator will remain red and the dehumidifier cannot restart.

CONTINUOUS DRAINAGE

For continuous operation or automatic dehumidification, connect the drain hose to the dehumidifier. The condensed water can automatically flow to a bucket or drain by gravity.
Straighten the drainage tube.
Insert one end of the hose into the cistern orifice and connect the other end to the bathtub, outdoors, a bucket-like recipient, or to a designated drainage area.

How to correctly place the drainage hose
In continuous drainage mode, the hose should be placed below the drainage orifice. Avoid uneven surfaces and do not bend the hose.

WARNING
Do not block the drain or drainage tube.
Do not bend the drainage tube. The height of the drain should be lower than the outlet.
The drainage tube should be safely connected to the outlet.

CLEANING AND MAINTENANCE

For safety reasons, ensure that the dehumidifier is turned off before cleaning or repairing it.

Cleaning the exterior of the dehumidifier
Clean the exterior with a clean and dry cloth.
If the dehumidifier is very dirty, clean it with a neutral detergent and then remove the detergent with a damp cloth.
Do not wash the appliance with a hose as this will cause energy leaks and risk of electric shock.

Cleaning the air filter (every 2 weeks)
Dust accumulates in the filter and restricts air flow. Restricted air flow reduces the efficiency of the system and, if blocked, can damage the dehumidifier.
The air filter requires regular cleaning. The air filter is removable to facilitate cleaning.
Do not plug in the dehumidifier without the air filter or it may become contaminated.
Remove the water tank from the body of the appliance and then remove the filter from the lower part of the rear lid.
Use a vacuum cleaner to gently suction the dust from the surface.
If the filter is very dirty, wash it with water and a mild detergent, then dry it very well.
Return the filter to place.

PRECAUTIONS AND WARNINGS

Empty the water tank when full or when the full tank indicator appears on the screen. After emptying the removable water tank, return it to its original position.
The appliance will resume operation.
Whenever the appliance stops, you should wait for at least 3 minutes before restarting it to prevent damage to the compressor.
If the appliance does not start or if it intermittently stops working for unknown reasons, check the power cord and plug.
If these are in normal working condition, unplug the appliance from the wall outlet and wait 10 minutes before restarting it.
If after 10 minutes the appliance does not restart, contact FLAMA (customer support line) or an authorized technical support service.
While the appliance is working, the compressor produces heat, which can raise the temperature of the room. This is normal and does not affect the operation of the appliance.

STORAGE

If you will not use the appliance for a long period of time, follow the following steps:
Remove the plug from the wall outlet and empty the water tank. Allow the water tank and dehumidifier to dry completely.
Clean the air filter.
Store the appliance vertically in a dust-free location, preferably covered with a plastic covering.

TROUBLESHOOTING

ANOMALY PROBABLE CAUSE SOLUTION
The appliance does not turn on. It is not connected to a power source. Plug

it into the wall outlet.
The water tank is full.| Empty the water tank.
The water tank is not correctly placed.| Reposition the water tank.
Temperature < 5°C or > 35°C.| Appliance protection.
Poor performance.| The air filter is clogged.| Clean the air filter.
The intake or outlet ducts are obstructed.| Remove the obstruction from the intake or outlet ducts.
Little dehumidifying capacity.| Dirty air filter.| Clean the filter.
Air intake or outlet blocked.| Unblock the air intake or outlet.
Noise.| The appliance is unstable.| Check that the appliance is in a stable position.
The air filter is clogged.| Clean the air filter.
E2|
Humidity sensor.| Contact technical assistance.
LO| Ambient humidity below 20%.| The dehumidifier turns off to protect itself.
Oi| Ambient humidity above 90%.
CI| Protection against low temperature.
Ch| Protection against high temperature.

REQUIRED INFORMATION

Power supply 220V-240V~, 50Hz
Dehumidification capacity (30°C/RH80%) 20L/day
Nominal input power 370W (30°C/80%)
Refrigerant / Load R290 / 0.058 kg
Operating temperature 5°C- 35°C
Tank capacity 6.5 L
Dimensions (L x D x H) mm 343x237x570 mm
Net weight 14 kg

ANOMALIES AND REPAIR

In case of malfunction, please take the appliance to an authorized Technical Assistance Service. Do not attempt to disassemble or repair the appliance, as this may be dangerous.

PROTECTING THE ENVIRONMENT

This symbol indicates the separate collection of electrical and electronic equipment.
The main objective of the separate collection of this waste is to reduce the quantity to be disposed of, promote reuse, recycling and other forms of recovery in order to reduce its negative effects on the environment.
When it is no longer in use, this appliance must not be disposed of together with other unsorted municipal waste.
The user is responsible for delivering it free of charge to the selective collection facilities available for that purpose.
Pieces of equipment that are no longer in use can also be taken back at points of sale, by purchasing new pieces of equipment that are equivalent and have the same functions.
For more detailed information on collection points, please contact your City Council or a point of sale for this equipment.

Fábrica de Louças e Electrodomésticos, S.A.
Rua Alto de Mirões, nº249
Zona Industrial de Cesar 3700-727 Cesar Portugal
t. +351 256 850 170