DH Lifelabs Aaira Surface Multi-Purpose Cleaning and Disinfecting System Instruction Manual

June 10, 2024
DH Lifelabs

DH Lifelabs Aaira Surface Multi-Purpose Cleaning and Disinfecting
System Aaira Surface
INSTRUCTION MANUAL
Created by nature*
Engineered by science.

Thank you for your purchase.
Now you can clean easy.
The Aaira Surface starts with a solution of tap water, salt (non- iodized), and 5% white vinegar and through the use of electrolysis to generates hypochlorous acid (HOCl).
All the things you need to know are here.

Your safety is important to us

Read all safety instructions before you use the device.
WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY PLEASE ADHERE TO THE FOLLOWING:

  1. Use only as described in the Instruction Manual. Do not carry out any maintenance other than that shown in this guide or as advised by customer support. Any other use not recommended by the manufacturer may cause fire, electric shock or injury.

  2. When moving the machine, hold it by the base. DO NOT MOVE THE MACHINE WITH WATER IN THE PITCHER.

  3. THIS MACHINE IS NOT INTENDED FOR USE BY CHILDREN. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by  children. This appliance can be used by children 8 years and above if supervised.

  4. This machine is not intended for use by persons with reduced physical, sensory or reasoning capabilities or lack of experience or knowledge unless they have been given  supervision or instruction concerning the use of the machine by a person responsible for their safety.

  5. Do not use it on wet surfaces or outdoors. Do not use in bathrooms. Never operate the machine where it may fall in the bath or other water container.
    Do not use or store it where it may get wet or in the immediate surroundings of a bath, shower or swimming pool.

  6. Do not pour water into any openings except for the pitcher. When refilling, only do so as described in this guide.
    DO NOT USE HOT WATER.

  7. Do not handle any part of the plug with wet hands.

  8. Do not use the machine with a damaged cord or plug. If the cord is damaged it must be replaced.

  9. If the machine is not working properly, has received a sharp blow, has been dropped or damaged, do not use the machine and contact customer support for repair.

  10. ALWAYS PLACE MACHINE ON A FIRM, FLAT, LEVEL SURFACE.

  11. Turn off all controls before unplugging.
    Always unplug machine when not in use.

  12. READ AND SAVE THESE INSTRUCTIONS.

  13. THIS MACHINE IS INTENDED FOR HOUSEHOLD AND INDOOR USE ONLY.

Read all safety instructions in the quick start guide, instruction manual, and on the device.

Product Overview

DH Lifelabs Aaira Surface Multi-Purpose Cleaning and Disinfecting System -
Overview

  1. Pitcher

  2. Cap/Vinegar
    Measuring Cup

  3. Salt Bottle with
    1 Gram Scoop

  4. Base

  5. Power Supply

  6. Stirring Stick

  7. Green Spray Bottle (Used to fill with low concentration disinfectant)

  8. Blue Spray Bottle (Used to fill with high concentration disinfectant)

How It Works
Aaira Surface can produce two different concentrations of HOCl disinfectant: High Concentration
The high-concentration HOCl disinfectant has 200 mg/L (200 PPM) of free effective chlorine.
Low Concentration
The low-concentration HOCl disinfectant has 100 mg/L (100 PPM) of free effective chlorine.
Aaira Surface starts with a solution of water, salt (non-iodized), and 5% white vinegar.
Through the use of electrolysis it generates hypochlorous acid (HOCl). This acidic water can be used for cleaning and disinfecting a wide range of surfaces. It neutralizes  99.9% of germs on surfaces.

Unpacking and Setup

  1. Remove the unit from the box and check that all the items shown in the product overview are included. It is a good idea to keep the packaging for storage or in the  event it must be shipped back for service.
  2. Locate the unit on a flat, stable surface in proximity to an AC electrical outlet.
  3. Connect the power supply to the unit and route the power cord to the outlet, but do not plug it in yet. Make sure that the power supply is out of the way and does not pose a tripping hazard. Keep it out of reach of children and pets.
  4. To begin using the unit you will need non-iodized salt.
  5. You will need 5% white vinegar.
  6. Finally, you will need ordinary water.

Getting Started

  1. Fill to max water line with tap water and add non-iodized salt:
    • 2 scoops (2 grams) for low concentration (100 PPM).
    • 4 scoops (4 grams) for high concentration (200 PPM).

  2. Stir the salt for 10 seconds with the provided stirring stick. Use the vinegar measuring cup to add 4ml/0.14oz. of 5% white vinegar.

  3. 3A Press the left button to make low concentration (100 PPM) HOCl disinfectant. Wait 9 minutes until process is complete.

  4. 3B Press the right button to make high concentration (200 PPM) HOCl disinfectant. Wait 12 minutes until process is complete.

  5. When the disinfectant is ready.
    Pour into coordinating spray bottle.
    Remove safety clip before use.
    DH Lifelabs Aaira Surface Multi-Purpose Cleaning and Disinfecting System -
safetyUse the green bottle for low concentration disinfectant (100 PPM).
    Use the blue bottle for high concentration disinfectant (200 PPM).
    DH Lifelabs Aaira Surface Multi-Purpose Cleaning and Disinfecting System -
disinfectant

Operating Procedures

  1. Place the pitcher on the base.

  2. Add 1000ml/33.81 oz. of tap water.

  3.  Add salt:
    • 2 scoops of non-iodized salt for low concentration HOCl disinfectant
    • 4 scoops of non-iodized salt for high concentration HOCl disinfectant

  4. Add 4ml/0.14oz. of 5% white vinegar. Use the cap of the salt bottle as a measuring cup.

  5. Using the stirring stick, vigorously stir the water for 10 seconds to fully dissolve the salt. NOTE: If you do not adequately stir the water, salt may accumulate on
    the electrolysis pad.

  6. Place the lid on the pitcher.

  7. Plug the power supply into the unit. You will hear a power up chime sound and the LED in the base will light up. After three seconds, the LED will go out indicating  that the unit is in standby mode.

  8. Press the Function Button on either the low concentration (left) side or the high concentration (right) side to begin the HOCl generation process.

  9. The LED in the base will illuminate (green for low concentration or blue for high concentration) and then slowly pulse, indicating that the HOCl generation process is  underway.
    NOTE: If you wish to cancel the process at any time, press and hold any part of the function button for two seconds and the unit will return to standby mode.

  10. The electrolysis process will take 9 minutes for low concentration HOCl and 12 minutes for high concentration HOCl. When the process is complete, you will hear the  shutdown chime sound and the base LED will go out.

  11. Your HOCl disinfectant is now ready for use. You can fill the spray bottle with the HOCl disinfectant, remove the safety clip and begin using it for cleaning, deodorizing, or disinfecting. Do not overfill or underfill the spray bottle for best effectiveness.
    NOTE: The HOCl disinfectant will lose effectiveness over time. You should discard it after 1-2 days and process a new batch.

Control Panel

| Low Concentration
HOCl Disinfectant (100 PPM)
---|---
| High Concentration
HOCl Disinfectant (200 PPM)

Where to Use
Remove heavy deposits from surfaces before using the HOCl disinfectant. Be sure to test HOCl in a small, inconspicuous area before using to ensure discoloration does not occur.

Everyday Use
Low Concentration (100 PPM)
Clean high-touch areas and surfaces including but not limited to countertops, tabletops, appliances, cabinets, doors and windows.
Disinfectant
High Concentration (200 PPM)
Heavy duty cleaning areas including but not limited to bathtubs, showers, toilets, floors, sinks and drains.

Troubleshooting

Symptom Probable Cause/Solution
Base LED does not illuminate Power problem. Check power cord and circuit

breaker.
Base LED illuminated, but no bubbles in pitcher during electrolysis| Pitcher is not securely mounted in base; make sure it is seated properly.
Base LED illuminated, but bubbles are sparse| Possibly using purified or distilled water; use ordinary tap water.
Unit does not operate| Make sure the amounts of salt and vinegar are correct for the concentration being produced.

Device Specifications

Model Number ASE-00WHO7
Power COrISUITIption 18 Watts
Input Voltage 120 VAC, 60Hz
Pitcher Capacity 1000mI/33.81 oz
Spray Bottle Capacity 150mI/5 07oz. *2

HOCI Recipe
(Low concentration 100ppm)| 2 scoops ( 2 grams) of non-iodized salt 1000mI/33.81 oz. of tap water: 4m1/0.14oz. of 5% white vinegar
HOCI Recipe
(High concentration 200ppm)| 4 scoops (4 grams) of non-iodized salt: 1000mI/33.81 oz. of tap water: 4mI/0.14oz. of 5% white vinegar
Material & Finish| ABS, White
Dimensions| 6.6x 6.8x 9 inches (167.4 x 171.7 x 229.7 mm)
Net Weight (without water)| 1.87Ibs (0.85kg)

Cleaning & Maintenance

We recommend not leaving disinfectant in pitcher or bottles for more than 48 hours.

How to clean:

  1. Fill the pitcher with 500ml/16.91oz. of water.
    Do not add any salt or vinegar.

  2. Press both buttons on the control panel.

  3. Wait 3 minutes.

  4. Empty pitcher.
    • Do not leave disinfectant in the bottle for an extended period of time (no more than 48 hours is recommended).
    • When the device won’t be used for an extended period of time store it in a cool dry place. Do not store the device where it might be exposed to excessive moisture or direct  sunlight. The device may not operate effectively in very low temperatures. The device can be damaged when exposed to sub-freezing temperatures.
    • Use a dry cloth to clean the exterior of the device. Do not use any chemicals or cleaners
    • Do not allow water to accumulate between the pitcher and the base. If the matting surface of the base is wet, immediately wipe dry with a clean, dry cloth and allow to thoroughly dry before use.
    • Do not remove the electrode from the bottom of the pitcher. Avoid any vigorous rubbing or cleaning of the electrodes. If you see white, scaly mineral deposits collecting on the electrode, add a small amount of vinegar to the pitcher and gently clean it to remove the scaling.

Product Warranty

This 2 year limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under  this warranty. DH Lifelabs IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF  MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above  limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction.  This warranty applies only to the original purchaser of this product from the original date of purchase.
At its option, D&HLifelabs will repair or replace this product if it is found to be defective in material or workmanship.
This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.

FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this  device must accept any interference received, including interference that may cause undesired operation.
Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the  equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to  provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to  radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the  following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

DH Lifelabs Aaira Surface Multi-Purpose Cleaning and Disinfecting System -
ce

EPA EST NO. 99117-CHN-1
MADE IN CHINA
*The Aaira Mini uses HOCl Technology that takes ingredients found in nature (water and non-iodized salt) and uses science (electrolysis) to create a powerful disinfectant.