DH Lifelabs Aaira + humidifier Instruction Manual
- June 10, 2024
- DH Lifelabs
Table of Contents
Aaira + humidifier
Aaira + Humidifier
INSTRUCTION MANUAL
Thank you for your purchase.
Now you can breathe easy.
The Aaira + Humidifier is a
comprehensive device used to
remove the bacteria and viruses from
the air you breathe. It generates
hypochlorous acid (HOCl) to sterilize
the air while incorporating a cold
evaporation filter (CEF).
Your safety is important to us.
Read all safety instructions before
you use the device.
WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR INJURY PLEASE ADHERE TO THE
FOLLOWING:
! Use only as described in the
instruction manual. Do not carry out
any maintenance other than that
shown in this guide or as advised by
customer support. Any other use not
recommended by the manufacturer may
cause fire, electric shock or injury.
! Ensure the machine is fully assembled
in accordance with the instructions
before use.
! Do not move the machine while it
is plugged in or powered on. Make
sure the machine is powered off and
unplugged before moving.
! When moving the machine, hold it by
the base of the water tank and please
take care to avoid spilling the water
inside the machine. If water is spilled
while moving, wipe the machine dry
with a clean cloth before use. If water is
spilled inside the machine while moving,
do not use and allow the water in the
machine to dry completely before.
! THIS MACHINE IS NOT INTENDED
FOR USE BY CHILDREN. Children shall
not play with the appliance. Cleaning
and user maintenance shall not be made
by children. This appliance can be used
by children 8 years and above
if supervised.
! This machine is not intended for use
by persons with reduced physical,
sensory or reasoning capabilities or
lack of experience or knowledge unless
they have been given supervision or
instruction concerning the use of the
machine by a person responsible for
their safety.
! Do not use the machine on wet surfaces
or outdoors. Do not use in bathrooms.
Never operate the machine where it may
fall in the bath or other water container.
Do not use or store it where it may get
wet or in the immediate surroundings of
a bath, shower or swimming pool.
! Do not pour water into any openings except
for the water tank. When refilling, only do
so as described in this guide. DO NOT USE
HOT WATER.
! DO NOT LOCATE DIRECTLY BELOW A
MAIN ELECTRICITY SUPPLY SOCKET.
! This machine may have hot parts inside.
Do not use in areas where fuel, paint
or flammable liquids are present. Keep
combustible materials away from the
machine.
DO NOT USE NEAR FURNACES,
FIREPLACES, STOVES OR OTHER HIGHTEMPERATURE
HEAT SURFACES.
! To reduce the risk of electric shock, this
machine has a polarized plug. If the plug
does not fit fully in the outlet, reverse the
plug. If it still does not fit, contact a qualified
electrician to install the proper outlet.
Do not change the plug in any way. (Not
applicable in UK).
! Always plug directly into a wall socket.
Never use the machine with an extension
cord as overloading may result in the cord
overheating or catching fire.
! Do not unplug by pulling the cord from
the socket. To unplug, grasp the plug, not
the cord.
! Do not handle any part of the plug with
wet hands.
! Do not use the machine with a damaged
cord or plug. If the cord is damaged it must
be replaced.
! Do not allow the area around the machine to
become damp or wet. If dampness occurs,
turn the output of the humidifier down or
use intermittently. Do not allow absorbent
materials, such as carpeting, curtains,
drapes, or tablecloths, to become damp.
! If the machine is not working properly, has
received a sharp blow, has been dropped
or damaged, do not use the machine and
contact customer support for repair.
! Do not use the machine on a soft or unstable
surface. ALWAYS PLACE THE MACHINE ON
A FIRM, FLAT, LEVEL SURFACE.
! DO NOT COVER THE MACHINE WHILE
IN USE.
! Never leave water in the reservoir when not
in use. Empty and clean before storage.
Clean before next use.
! When removing the cold evaporation filter,
take care to keep your fingers clear from
in between the filter and the machine base.
! Turn off all controls before unplugging.
Always unplug the machine if not in use
and while filling or cleaning.
! For best performance, place the machine
on the floor at least 3 feet from any wall
or appliances.
! READ AND SAVE THESE INSTRUCTIONS.
! THIS MACHINE IS INTENDED FOR
HOUSEHOLD AND INDOOR USE ONLY.
! Warning: Micro-organisms that may be
present in the water or in the environment
where the appliance is used or stored, can
grow in the water reservoir and be blown in
the air causing very serious health risks when
the water is not renewed and the tank is not
cleaned properly every 3 days.
Read all safety instructions in the quick start guide, instruction manual and on device.
Product Overview
1. Water Tank
2. Cold Evaporation Filter (CEF)
3. Cold Evaporation Filter Lid (CEF Lid)
4. Top Cover
5. Salt Bottle with 1 Gram Scoop
6. Power Cord
7. Pre-Filter
How It Works
The Aaira + Humidifier has a two-stage cleaning system to disinfect the air. A fan draws air in through the pre-filter at the bottom of the purifier. Inside, the air passes through the Cold Evaporation Filter and exits through the top cover. The two stages to the air purifier are:
STAGE 1: Pre-filter.
The pre-filter has a screen that captures large airborne particles.
STAGE 2: Cold Evaporation Filter (CEF).
The CEF absorbs the HOCl water generated in the water tank. The HOCl water is evaporated as air passes through the CEF. This disperses the HOCl molecules throughout the airspace in the room allowing it to destroy a variety of bacteria and viruses.
Unpacking and Setup
-
Remove the air purifier from the box and check that all the items are included. It is a
good idea to keep the packaging for storage or in the event it must be shipped back
for service. -
Remove the top cover and make sure the CEF and CEF lid are securely in place.
-
Place the Aaira + Humidifier on a flat, solid surface in proximity to an AC electrical
outlet. -
Connect the power cord to the Sterilizer, and route the power cord to the outlet, but
do not plug it in yet. Make sure that the power cord is out of the way and does not
pose a tripping hazard, and is out of reach of children and pets.
Getting Started
1 Make sure the Cold Evaporation
Filter (CEF) is secure and the CEF
lid is locked in place.
2 Fill salt bottle with non-iodized salt and place
3 scoops (3 grams) on top sides of the lid.
Skip this step for humidification only.
3 Close the top cover
4 Fill water to MAX line,
washing all salt off the
CEF lid.
5 Press the power button to
turn on and select fan and
sterilize function.
Control Panel
(SOLID)
Low Salt Alert
Solid salt level indicator
Solid blue light
Sound alert
What to do:
1. Power off device
2. Add 3 scoops (3 grams)
of non-iodized salt
3. Fill water to MAX line
(FLASHING)
High Salt Alert
Flashing salt level indicator
Flashing blue light
Sound alert
What to do:
1. Power off device
2. Empty water tank
3. Rinse the CEF
4. Add 3 scoops (3 grams) of non-iodized salt
5. Fill water to MAX line
(SOLID)
Low Water Alert
Solid water level indicator
Flashing blue light
Sound alert
What to do:
1. Power off device
2. Fill water to MAX line
Copyright © 2022 Dernier & Hamlyn Inc. All rights reserved. Revised 2022/06/23
Operating Procedures
1. Press the On/Off button to turn the air purifier on. A start-up sound will
play and
all the indicators on the control panel will turn on for 3 seconds.
2. The On/Off button will be illuminated white, indicating that the purifier
is in
standby mode.
3. Press the On/Off button again to begin operation. The blue light in the
water
tank will turn on, the fan speed will default to level 2, and the Sterilize
button will
illuminate, indicating that the sterilizer is actively disinfecting the air in
the room.
4. Press the fan speed button to toggle the fan speed between sleep, 2, and 3
speeds. When sleep mode is selected, fan speed is reduced and the blue light
inside the water tank will turn off.
5. Press the power On/Off button again to turn the purifier off.
Timer Operation
Press the timer button to toggle through the options (2H-4H-8H-None). Once
selected,
an internal timer controls operation of the purifier for the selected
duration. Once the
timer expires the purifier enters standby mode.
NOTE: Do not use this option if you want the sterilizer to run continuously.
Humidifier Operation
1. Fill the water tank with clean water. DO NOT add salt to the tank.
2. Press the Sterilize button to toggle the Sterilize function off. This will
stop
the disinfection function.
CEF Replacement
1. Remove the CEF lid.
2. Unscrew the CEF from the tank and discard. NOTE: Handle the new CEF by the
end
caps to avoid touching the element, this will prevent possible contamination
of the
filter element.
3. Remove the replacement CEF from packaging and screw it into the bottom of
the
water tank. Plug in the power cord.
4. Turn on the Sterilizer and press and hold the Sterilize button for three
seconds to reset
the filter life countdown.
If you replace the filter before the accumulated life time is reached, the
filter life timer
cannot be reset. To purchase replacement filters, please visit:
www.dhlifelabs.com
Troubleshooting
Symptom – Probable Cause/Solution
Low air flow – Check that Pre-Filter and the air inlet are free from
obstructions
and not blocked by dust, trash, etc. Clean as necessary.
Emits a chlorine (disinfection) smell – Chlorine smell is normal. You can change to sleep mode to minimize the smell in the room.
Air from the Sterilizer smells bad – Check that water tank and CEF are clean. Clean water tank regularly and replace CEF as necessary.
The Sterilizer has been tipped over or fallen – Immediately unplug the power cord. Lift up the Sterilizer and wipe off any water on the surface of the machine. Allow the Sterilizer to completely dry before resuming operation.
Water added to Water Tank, and water level indicator is still flashing – Please discard all water in the tank and check again. If it still does not work, contact Customer Assistance.
Salt Level indicator displayed even after salt has been added – It takes some time to dissolve the salt and monitor the actual concentration. If it still does not work after some time, discard salt water solution and mix a new batch per the instruction carefully.
Salt Level indicator flashing after salt has been added – Make sure
amount of salt added is correct. If necessary discard salt water solution and
mix a new batch per the instruction
carefully.
For any issues not covered here, contact Customer Assistance.
Device Specifications
Model Number AAE-50XX05
Power Consumption 22 Watts
Input Voltage US 120V, 60Hz / UK 220-240V~, 50/60Hz
Fan Speed 3 levels (Sleep/2/3)
Noise Max. 53 dB(A)
Timer 2H/4H/8H
Water Tank Capacity 2500ml/84.54oz.
HOCl Recipe 3 scoops of non-iodized salt: 2500ml/84.54oz.
of water
Material & Finish ABS, Glossy White & Silver belt
Recommended Room Size 538 ft2 (50 m2)
Reminder
– Filter Replacement Reminder: CEF
– Salt Level Reminder
– Water Level Reminder
Dimensions H13.6 x Dia10.6 inches (H347x Dia270 mm)
Net Weight (without water) 7.28 lbs (3.3 kg)
Product Warranty
This 2 year limited warranty applies to repair or replacement of product found
to be
defective in material or workmanship. This warranty does not apply to damage
resulting from commercial, abusive, unreasonable use or supplemental damage.
Defects that are the result of normal wear and tear will not be considered
manufacturing defects under this warranty.
DH Lifelabs IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED TO THE DURATION OF THIS WARRANTY.
Some jurisdictions do not allow the exclusion or limitation of incidental or
consequential
damages or limitations on how long an implied warranty lasts, so the above
limitations or
exclusions may not apply to you. This warranty gives you specific legal
rights, and you also may have other rights which vary from jurisdiction to
jurisdiction. This warranty applies only to the original purchaser of this
product from the original date of purchase.
At its option, D&HLifelabs will repair or replace this product if it is found
to be defective in material or workmanship.
This warranty does not cover damage resulting from any unauthorized attempts
to repair or
from any use not in accordance with the instruction manual.
This warranty does not cover the filter except for material or workmanship
defects.
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Caution: The user is cautioned that changes or modifications not expressly
approved
by the party responsible for compliance could void the user’s authority to
operate the
equipment. Note: This equipment has been tested and found to comply with the
limits for
a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed
to provide reasonable protection against harmful interference in a residential
installation.
This equipment generates uses and can radiate radio frequency energy and, if
not installed
and used in accordance with the instructions, may cause harmful interference
to radio
communications. However, there is no guarantee that interference will not
occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
MADE IN CHINA
- The Aaira + Humidifier uses HOCl Technology that takes ingredients found in nature (water and non-iodized salt) and uses science (electrolysis) to create a powerful disinfectant.