GE APPLIANCES AHD06 Energy Star 6,200 Btu Ultra Quiet Window Air Conditioner Owner’s Manual
- June 10, 2024
- GE Appliances
Table of Contents
- AHD06 Energy Star 6,200 Btu Ultra Quiet Window Air Conditioner
- IMPORTANT SAFETY INFORMATION
- USING THE AIR CONDITIONER
- CARE AND CLEANING
- Installation Instructions
- Troubleshooting Tips… Before you call for service
- LIMITED WARRANTY
- Consumer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AHD06 Energy Star 6,200 Btu Ultra Quiet Window Air Conditioner
OWNER’S
MANUAL
AHD06, AHD08
AHD06 Energy Star 6,200 Btu Ultra Quiet Window Air Conditioner
Write the model and serial numbers here:
Model #
Serial #
You can find the rating label on the side of the air conditioner.
GE is a trademark of the General Electric Company. Manufactured under
trademark license.
THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.
Whether you grew up with GE Appliances, or this is your first, we’re happy to
have you in the family.
We take pride in the craftsmanship, innovation and design that goes into every
GE Appliances product, and we think you will too. Among other things,
registration of your appliance ensures that we can deliver important product
information and warranty details when you need them.
Register your GE appliance now online. Helpful websites and phone numbers are
available in the Consumer Support section of this Owner’s Manual. You may also
mail in the pre-printed registration card included in the packing material.
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
WARNING For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
- Use the appliance only for its intended purpose described in this Owner’s Manual.
- This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.
- Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
- Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
- Turn the unit OFF and unplug your air conditioner before cleaning.
- For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
- If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.
- Turn the unit OFF and unplug your air conditioner before cleaning.
- For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
- If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.
WARNING
Risk of Fire or Explosion. This unit contains flammable refrigerant.
Additional safety precautions must be followed.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater.
- Do not pierce or burn refrigerant tubing. Be aware that refrigerants may not contain an odor.
- Keep ventilation openings clear of obstruction.
- When handling, installing, and operating the appliance, care should be taken to avoid damage to the refrigerant tubing.
- Do not drill holes in the unit.
- Maintenance, cleaning, and service should only be performed by technicians properly trained and qualified in the use of flammable refrigerants.
- GE Appliances does not support any servicing of the air conditioner.
- Dispose of air conditioner in accordance with Federal and Local Regulations. Flammable refrigerants require special disposal procedures. Contact your local authorities for the environmentally safe disposal of your air conditioner.
WARNING
USE OF EXTENSION CORDS RISK OF FIRE.
Could cause serious injury or death.
- DO NOT use an extension cord with this Window Air Conditioner.
- DO NOT use surge protectors or multi-outlet adaptors with this Window Air Conditioner.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from
the power cord. For personal safety, this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong (grounding) plug
which mates with a standard 3-prong (grounding) wall outlet to minimize the
possibility of electric shock hazard from this appliance.
Power cord includes a current interrupter device. A test and reset button is
provided on the plug case. The device should be tested on a periodic basis by
first pressing the TEST button and then the RESET button while plugged into
the outlet. If the TEST button does not trip or if the RESET button will not
stay engaged, discontinue use of the air conditioner and contact a qualified
service technician.
Have the wall outlet and circuit checked by a qualified electrician to make
sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility
and obligation to have it replaced with a properly grounded 3-prong wall
outlet.
The air conditioner should always be plugged into its own individual
electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring
circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for
specific electrical connection requirements.
USING THE AIR CONDITIONER
Controls
Features and appearance will vary.
This section explains how to operate this air conditioner.
IMPORTANT:
When you turn off the air conditioner, either at the control panel or with the
remote control, wait at least 3 minutes before turning it back on. This
prevents the compressor from overloading. This 3 minute delay also applies
when switching from cool mode to fan and back.
NOTE: There is a built in 3 minute delay. You may notice the compressor
might not start right away. This was designated to protect the unit.
Do not operate your air conditioner in the Cool Mode when the outside
temperature is below 61° F (16° C). This inside evaporator coil will freeze
up, and the air conditioner will not operate properly.
NOTE: When the air conditioner is first plugged in, the LED display will
show “88” for 3 seconds. After the air conditioner is turned on for the first
time, the display will show the temperature 72° F and the fan will
automatically set the Quiet speed and the Mode indicator will show ENERGY
SAVE.
NOTE: To switch the temperature display between Fahrenheit (°F) and
Celsius (°C), the air conditioner must be plugged in and turned on. On the
control panel on the at the same time and hold for 3 seconds. Press F/C button
on remote control to switch between Fahrenheit (°F) and Celsius (°C).
NOTE: Each time this ENERGY STAR qualified air conditioner is turned on,
it will operate in energy save mode per the EPA requirements. You can select
any other mode
to satisfy your needs.
Controls
1. MODE
- Press MODE until you see the indicator light come on next to the desired setting.
- Choose Fan, Cool, Energy Save, or Dehum.
Fan – Only the fan runs. Press SPEED to select High, Med or Quiet fan speed.
The display shows the current room temperature. NOTE: in fan mode, the
temperature cannot be set.
Energy Save – In this this mode the fan runs only when cooling is needed. The
fan will run for 3 minutes after the compressor shuts off. The fan then cycles
on for 2 minutes at 10 minute intervals until the temperature in the room is
above the set temperature. The compressor then turns back on.
Cool – Cools the room. Press SPEED to select High, Med, Quiet or Auto Cool fan
speed. Press the TEMP/ TIME + or – button to adjust the temperature. The fan
will run continuously in cool mode.
Dehum – Aids in removing humidity from the room.
Dehum mode cannot be used to cool room.
NOTE: In Dehum mode, when the set temperature is close to ambient
temperature, the compressor may stop and the fan will run in Quiet speed only.
2. SPEED
- Press SPEED until you see the indicator light come on next to the desired setting.
- Choose High, Med, Quiet, or Auto Cool
HIGH – For maximum cooling.
MED – For normal cooling.
QUIET – For minimum cooling and noise.
AUTO COOL – Adjusts the fan speed automatically to provide ideal cooling based on the room temperature.
3. TIMER OFF
To set the air conditioner to turn off between 1 hour and 24 hours (the air
conditioner must be ON to set).
- Press TIMER button until Timer Off indicator light illuminates. The display will show the remaining hours before the air conditioner will turn off.
- Press the TEMP/TIME + or – button to change the delay time from 1 hour to 24 hours..
- Timer Off indicator light will remain on. The display will show the remaining time to Timer Off.
4. TIMER ON
To set the air conditioner to turn on between 1 hour and 24 hours.
- Press TIMER button until Timer On indicator light illuminates. The display will show the remaining hours before the air conditioner will turn on.
- Press the TEMP/TIME + or – button to change the delay time from 1 hour to 24 hours..
- Timer On indicator light will remain on. The display will show the remaining time to Timer On.
To clear TIMER Program:
NOTE: Air conditioner can be either on or off.
Press TIMER until Timer indicator light turns off.
To view or change the remaining time (in hours):
TIMER OFF –
- Press the TEMP/TIME + or – button to increase or decrease the time.
- The display will show the remaining time to Timer OFF.
TIMER ON –
- The display will show the remaining time.
- Press the Temp Time + or – button to increase or decrease the time.
- The display will show the remaining time to Timer ON.
NOTE: In TIMER and SLEEP mode, temperature cannot be adjusted.
5. SLEEP
- Press the TIMER button to choose Sleep mode. The indicator light will turn on.
- The temperature will increase by 2° F one hour after the mode is chosen. The temperature then increases another 2° F after one hour. The unit will hold this temperature for six hours then stop.
- To turn off Sleep mode, press the TIMER button until the indicator light is off.
6. TEMP/TIME
- Press the TEMP/TIME + button to raise the temperature. Each time you press the TEMP/TIME + button, the temperature will go up by 1° F until it reaches 86° F (30°C).
- Press the TEMP/TIME – arrow button to lower the temperature. Each time you press the TEMP/ TIME – button, the temperature will go down by 1° F until it reaches 61° F (16° C).
NOTE: Under Fan mode, the display will show the current temperature.
Under Energy Save, Cool or Dehum mode, the display will show the set
temperature.
7. FILTER RESET
This feature automatically notifies you that the air filter must be cleaned.
The indicator light will come on after 250 hours of operation. Clean the air
filter (refer to Care and Cleaning section), place it back in the front panel,
and press the Filter Reset button. The light will turn off.
Using the Remote Control
Remote Control may differ in appearance from the image show.
NOTE: Please remove the back of the controller and insert two AAA
batteries. Replace batteries after 6 months of use or when remote control
starts to lose power. The remote control signal has a range of up to 20 feet.
NOTE: DO NOT mix old and new batteries.
1. POWER
Press the power button to turn on the air conditioner.
When you first press the power button, the air conditioner will operate in
Energy Save mode, Quiet fan speed and temperature of 72°F. You can select any
other mode to
satisfy your needs .
2. SPEED
High – Press HIGH button to choose high fan speed.
Med – Press MED button to choose medium fan speed.
Quiet – Press QUIET button to choose quiet fan speed.
Auto Cool – Press AUTO button to choose auto cool fan speed.
3. MODE
Fan- Press the FAN button to activate fan mode.
Cool – Press the COOL button to activate cool mode.
Energy Save – Press the ENERGY SAVE button to activate fan mode.
Dehum – Press the DEHUM button to activate dehum mode.
4. TIMER
To set the air conditioner to turn off after a set amount of time between 1
hour and 24 hours (unit must be ON):
- Press TIMER ON/OFF button on the remote control to select the time off function.
- Press the TIMER UP or TIMER DOWN arrow button to change the delay time from 1 hour to 24 hours. Timer OFF indicator light on the air conditioner panel will illuminate.
- The buzzer beeps twice after 5 seconds, then Timer OFF countdown will initiate.
To clear TIMER Program:
NOTE: Air conditioner can be either on or off. Press TIMER ON/OFF button
until Timer indicator light turns off.
5. TEMP UP/TEMP DOWN
- Press the TEMP UP button to raise the temperature. Each time you press the TEMP UP button, the temperature will go up 1° F until it reaches 86°F (30°C).
- Press the TEMP DOWN button to lower the temperature. Each time you press the TEMP DOWN button, the temperature will go down 1° F until it reaches 61°F (16°C).
6. SLEEP
- Press SLEEP button on the remote control to choose Sleep mode. This display will show (08) and the indicator light will turn on.
- The temperature will increase by 2° F one hour after the mode is chosen The temperature then increases another 2° F after one hour. The until will hold this temperature for six hours then stop.
- To turn off Sleep mode, press the SLEEP button until the indicator light is off.
7. FAHRENHEIT/CELSIUS
- Press the F/C button to choose between Fahrenheit and Celsius.
8. LOCK
- Press the LOCK button on the remote control to disable button functionality. Press the LOCK button again to activate the remote control functionality.
9. LIGHT
- When you press the LIGHT button, the display on the unit will turn off, but the unit is still operating normally. When you press the LIGHT button again or press any button on the remote control, the display will be illuminated again.
10. RESET
- Press the RESET button to reset the unit to factory settings.
Air Direction
COOL MIN:
To reduce cooling capacity, point air directional louvers up.
![GE APPLIANCES AHD06 Energy Star 6,200 Btu Ultra Quiet Window Air Conditioner
- Air Direction 1](https://manuals.plus/wp-content/uploads/2023/04/GE-
APPLIANCES-AHD06-Energy-Star-6200-Btu-Ultra-Quiet-Window-Air-Conditioner-Air-
Direction-1.png) COOL MAX:
To maximize cooling capacity, point air directional louvers down.
![GE APPLIANCES AHD06 Energy Star 6,200 Btu Ultra Quiet Window Air Conditioner - Air Direction 2](https://manuals.plus/wp-content/uploads/2023/04/GE-
APPLIANCES-AHD06-Energy-Star-6200-Btu-Ultra-Quiet-Window-Air-Conditioner-Air-
Direction-2.png) Changing the Air Direction
4-Way Air Flow: The air directional louvers let you control the direction of the airflow. The airflow can be directed up-down and left to right.
CARE AND CLEANING
Cleaning the Air Filter
The air filter is removable for easy cleaning. A clean air filter helps remove
dust, lint and particles from the air for optimal cooling operating
efficiency. The Filter Reset light will turn on to notify you that the air
filter must be cleaned. The light goes on after the air conditioner has been
operating for 250 hours.
- Turn off the air conditioner and unplug the power supply cord from the outlet.
- Remove the air filter by opening the front panel and removing the air filter. Some models may have a filter that slides out instead and does not require opening of the front panel.
- Use a vacuum cleaner with the hose attachment to clean the air filter. If the air filter is very dirty, wash it in warm water with mild detergent. Do not wash the air filter in a dishwasher or clothes washer, or use any chemical cleaners. Do not use a cloth dryer or microwave oven to dry it. Air dry the air filter completely before placing it back in the unit.
- Place the air filter back in the air conditioner.
- Close the front panel.
- Plug the power supply cord into the outlet, turn on the air conditioner and press the filter reset button to turn off the indicator light.
NOTE: Do not operate the air conditioner without the filter in place.
Cleaning the Front Panel
- Turn off the air conditioner and unplug the power supply cord from the outlet.
- Clean the front panel with a soft cloth. Do not use chemical cleaners, especially spray cleaners, sharp instruments, or flammable fluids. These products can damage the surface of your air conditioner.
- Air-dry the front panel completely.
- Plug the power supply cord in the outlet and turn on the air conditioner.
Installation Instructions
Questions? Visit our Website at: GEAppliances.com
BEFORE YOU BEGIN
Read these instructions completely and carefully.
- IMPORTANT – Save these instructions for local inspector’s use.
- IMPORTANT – Observe all governing codes and ordinances.
- Note to Installer – Be sure to leave these instructions with the Consumer.
- Note to Consumer – Keep these instructions for future reference.
- Skill level – Installation of this appliance requires basic mechanical skills.
- Completion time – Approximately 1 hour
- We recommend that two people install this product.
- Proper installation is the responsibility of the installer.
- Product failure due to improper installation is not covered under the Warranty.
- You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.
UNPACKING THE AIR CONDITIONER
WARNING
EXCESSIVE WEIGHT HAZARD – When moving or lifting the air conditioner, use
two or more people. Wear gloves when handling the air conditioner to protect
against possible sharp edges and metal fins.
Remove Packaging Materials
-
Remove packaging materials. Save the carton and the foam packaging for storing the unit when not in use.
NOTE: There is NO internal packing material inside the air conditioner to remove – DO NOT open the cabinet. -
Handle the air conditioner gently.
-
Keep the air conditioner upright and level. Do not set the air conditioner on its side, front, back or upside down.
-
The air conditioner must be standing upright for 2 hours prior to installation and operation.
ELECTRICAL REQUIREMENTS
These models require a 115/120-volt AC, 60-Hz grounded outlet protected with a
15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard.
If the wall outlet you plan to use is only a 2-prong outlet, it is your
responsibility to have it replaced with a properly grounded 3-prong wall
outlet.
CAUTION
Do not, under any circumstances, cut or remove the third (ground) prong from
the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems—consult a qualified
electrician.
Power cord includes a current interrupter device. A test and reset button is
provided on the plug case. The device should be tested on a periodic basis by
first pressing the TEST button and then the RESET button while plugged into
the outlet. If the TEST button does not trip or if the RESET button will not
stay engaged, discontinue use of the air conditioner and contact a qualified
service technician.
**TOOLS YOU WILL NEED
![GE APPLIANCES AHD06 Energy Star 6,200 Btu Ultra Quiet Window Air Conditioner
-
TOOLS](https://manuals.plus/wp-content/uploads/2023/04/GE-APPLIANCES-AHD06 -Energy-Star-6200-Btu-Ultra-Quiet-Window-Air-Conditioner-TOOLS.png) PARTS INCLUDED
(Appearance may vary 1. WINDOW REQUIREMENTS**- These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
- The air conditioner can be installed without the side curtain panels if needed to fit in a narrow window. See the window opening dimensions.
- All supporting parts must be secured to firm wood, masonry or metal.
- The electrical outlet must be within reach of the power cord.
- Follow the dimensions in the table and illustration for your model.
2. STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air conditioner to tilt toward the
outside, and will keep it from draining properly. To adjust for this, attach a
piece of wood to the sill.
WOOD PIECES WIDTH: 2
LENGTH : Long enough to fit inside the window frame.
THICKNESS: To determine the thickness, place a piece of wood on the sill
to make it 1/2″ higher than the top of the storm window frame or the vinyl
frame.
Attach securely with nails or screws provided by the installer.
![GE APPLIANCES AHD06 Energy Star 6,200 Btu Ultra Quiet Window Air Conditioner
- WINDOW REQUIREMENTS 1](https://manuals.plus/wp-content/uploads/2023/04/GE-
APPLIANCES-AHD06-Energy-Star-6200-Btu-Ultra-Quiet-Window-Air-Conditioner-
WINDOW-REQUIREMENTS-1.png) 3. PREPARE THE AIR CONDITIONER
A. Install the top mounting rail with 4 Type A screwsB. Slide the side curtain panels into the side panel rails. C. For model AHD06, cut and apply a weather strip to side of the curtain frame (one each side). D. Slide left and right side curtain frames into top and bottom rails. Make sure that side curtains snap into side of the frames.
4. INSTALL THE AIR CONDITIONER IN THE WINDOW
A. Measure the width of the window opening and mark the center line on the inside window sill.
![GE APPLIANCES AHD06 Energy Star 6,200 Btu Ultra Quiet Window Air Conditioner - frame 2](https://manuals.plus/wp-content/uploads/2023/04/GE-APPLIANCES-AHD06 -Energy-Star-6200-Btu-Ultra-Quiet-Window-Air-Conditioner-frame-2.png) For model AHD06:
![GE APPLIANCES AHD06 Energy Star 6,200 Btu Ultra Quiet Window Air Conditioner
- model](https://manuals.plus/wp-content/uploads/2023/04/GE-APPLIANCES-AHD06
-Energy-Star-6200-Btu-Ultra-Quiet-Window-Air-Conditioner-model.png) Place the
unit in the window. Lower the window sash to hold unit in place.
B. Set the air conditioner in the window so that is centered. Place the air conditioner so that front edge of the bottom mounting rail is against the back edge of the sill.
Make sure that the air conditioner is level or tilting slightly to the outside.C. Install the side bracket into the unit and into the window sill using two 1” wood screws provided. Repeat on other side. D. Extend the curtain panels until they fill the window. Mark the location of the holes in each corner of the curtain. Use the drill and 1/8″ drill bit to drill pilot holes. Use 4 type B screws to secure the side panels in place. 5. INSTALL WINDOW LOCKING BRACKET AND FOAM TOP WINDOW GASKET
bracket on top of the bottom window.
A. CAUTION
To prevent broken glass or damage to windows, on vinyl or other similarly
constructed windows, attach the window locking bracket to the window side jamb
with one
Type B screw.
![GE APPLIANCES AHD06 Energy Star 6,200 Btu Ultra Quiet Window Air Conditioner
- screw](https://manuals.plus/wp-content/uploads/2023/04/GE-APPLIANCES-AHD06
-Energy-Star-6200-Btu-Ultra-Quiet-Window-Air-Conditioner-screw.png)B. Cut the
foam top window gasket to the window width.
C. Stuff the foam between the glass and the window to prevent air and insects from getting into the room. NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.
D . For additional energy savings, on AHD06 only, measure and cut the adhesive backed foam sheets, and apply over the side curtains and frames to seal air leakage
Troubleshooting Tips… Before you call for service
Save time and money! Review the charts on the following pages first and you may not need to call for service.
Problem | Possible Cause | What To Do |
---|---|---|
Air conditioner does not start. | The unit is unplugged. | Make sure the air |
conditioner plug is pushed completely into the outlet.
The fuse is blown/circuit breaker is tripped.| Check the house fuse/circuit
breaker box and replace the fuse or reset the breaker.
Power Failure.| The unit will automatically restart in the setting last used
after the power is restored.
There is a protective time delay (approximately 3 minutes) to prevent tripping
of the compressor
overload. For this reason, the unit may not start normal cooling for 3 minutes
after it is turned back on.
The current interrupter device is tripped.| Press RESET button located on the
power cord plug.
If the RESET button will not stay engaged, discontinue use of the air
conditioner and contact a qualified service technician.
Remote control is not working| Batteries are dead.| Replace the batteries.
Batteries inserted wrong.| Make sure batteries are inserted in the correct
position.
Air conditioner does not cool as it should.| Indoor airflow is restricted.|
Make sure there are not curtains, blinds or furniture blocking the front of
the air conditioner.
The temp control may not be set properly.| Turn the temperature control to a
higher number.
The air filter is dirty.| Clean the filter at least every 30 days. See Care
and Cleaning section.
The room may have been hot.| When the air conditioner is first turned on, you
need to allow time for the room to cool down.
Cold air is escaping.| Check for open furnace registers and cold air returns.
Cooling coils have iced up.| See “Air conditioner freezing up” below.
Air conditioner freezing up| Ice blocks the air flow and stops the air
conditioner from cooling the room.| On models with control knobs, set the mode
control at High Fan or High Cool with the Temp at 1 or 2.
Water drips outside| Hot, humid weather.| This is normal.
Water drips inside| The air conditioner is not tilted to the outside.| For
proper disposal, make sure the air conditioner slants slightly from the case
front to the rear.
Water collects in base pan| Moisture removed from air and drain into base
pan.| This is normal for a short period in areas with little humidity; normal
for a longer period in very humid areas.
Normal Operating Sounds
- You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
- You may hear the thermostat click when the compressor cycles on and off.
- Water will collect in the base pan duringhigh humidity or on rainy days. The water may overflow and drip from the outdoor sideof the unit.
- The fan may run even when the compressor does not.
- Water droplets being thrown against the outside coils can make a pinging noise. This helps cool the condenser. You can reduce this noise by removing the subbase water plug.
![GE APPLIANCES AHD06 Energy Star 6,200 Btu Ultra Quiet Window Air Conditioner
- Water Plug](https://manuals.plus/wp-content/uploads/2023/04/GE-APPLIANCES- AHD06-Energy-Star-6200-Btu-Ultra-Quiet-Window-Air-Conditioner-Water-Plug.png)
To ensure maximum efficiency It is recommended to check to ensure the rubber
drain plug is properly inserted. This plug may be removed during operation to
minimize water in the back of the unit; however, removing it will lower the
efficiency of your unit.
NOTE: Do not drill hole in the base pan.
LIMITED WARRANTY
For The Period Of: | Will Replace: |
---|
One Year
From the date of the original purchase| Replacement, repair, or refund of the
original retail price for any product which fails due
to a defect in materials or workmanship. If the unit is exchanged, the
replacement unit
is warranted for the remainder of your product’s original one-year warranty
period. GE
Appliances will, at its sole discretion, replace the product with a product of
the same or
comparable functionality and quality or refund the original retail price.
In Order to Make a Warranty Claim During Your Retailer’s Allowable Return Period:
- Properly pack your unit. We recommend using the original carton and packing materials.
- Return the product to the retail location where it was purchased.
- Include in the package a copy of the sales receipt or other evidence of date of original purchase. Also print your name and address and a description of the defect.
In Order to Make a Warranty Claim During the Remainder of the One-Year Warranty:
- Locate your original sales receipt and make a note of your model and serial number.
- Call 866.907.1655 (in the united States)to initiate a warranty claim.
- You will be asked to provide your name, address, date of purchase, model and serial number.
- Warrant claims may require electronic or mailed-in evidence of purchase.
What Will Not Cover:
- Customer instruction. This owner’s manual provides information regarding operating instructions and user controls.
- Improper installation. If you have an installation problem, or if the product is of improper capacity, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
- Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
- Replacement of house fuses or resetting of circuit breakers.
- Failure due to corrosion.
- Damage to the product caused by improper power supply voltage, accident, fire, floods or acts of God.
- Incidental or consequential damage caused by possible defects with this product.
- Damage caused after delivery.
Staple your receipt here. Proof of the original purchase date is needed to
obtain service under the warranty.
EXCLUSION OF IMPLIED WARRANTIES – Your sole and exclusive remedy is
product repair as provided in this Limited Warranty. Any implied warranties,
including the implied warranties of merchantability or fitness for a
particular purpose, are limited to one year or the shortest period allowed by
law.
For US Customers: This limited warranty is extended to the original purchaser
and any succeeding owner for Appliances Authorized Servicer is not available,
you may be responsible for a trip charge or you may be required to bring the
product to an Authorized GE Appliances Service location for service. In
Alaska, the limited warranty excludes the cost of shipping or service calls to
your home.
Some states do not allow the exclusion or limitation of incidental or
consequential damages. This limited warranty gives you specific legal rights,
and you may also have other rights which vary from state to state. To know
what your legal rights are, consult your local or state consumer affairs
office or your state’s Attorney General.
Warrantor US:
GE Appliances, a Haier company
Louisville, KY 40225
Consumer Support
GE Appliances Website
Have a question or need assistance with your appliance? Try the GE Appliances
Website 24 hours a day, any day of the year! You can also shop for more great
GE Appliances products and take advantage of all our on-line support
GEAppliances.com
Register Your Appliance
Register your new appliance on-line at your convenience! Timely product
registration will allow for enhanced communication and prompt service under
the terms of your warranty, should the need arise. You may also mail in
GEAppliances.com/register
Parts and Accessories
Individuals qualified to service their own appliances can have parts or
accessories sent directly to their homes (VISA, MasterCard and Discover cards
are accepted). Order on-line today 24 hours every day.
In the US :GEApplianceparts.com or by
phone at 877.959.8688 during normal business hours. Instructions contained in
this manual cover procedures to be performed by any user. Other servicing
generally should be referred to qualified service personnel. Caution must be
exercised, since improper servicing may cause unsafe operation.
Contact Us
If you are not satisfied with the service you receive from GE Appliances,
contact us on our Website with all the details including your phone number, or
write to: GEAppliances.com/contact
References
- Appliance Parts, Accessories & Water Filters | GE Appliances
- Contact Us or Get Help with Questions | GE Appliances
- GEAppliances.com/register
- Horas Chuyên Trang Cung Cấp Thông Tin Ứng Dụng Telegram
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>