Autonics T3-T4 Series 1-Channel Digital Temperature Indicators Instruction Manual

June 10, 2024
Autonics

1-Channel Digital Temperature Indicators
T3 / T4 Series
INSTRUCTION MANUAL

T3-T4 Series 1-Channel Digital Temperature Indicators

Thank you for choosing our Autonics product.
Read and understand the instruction manual and manual thoroughly before using the product.
For your safety, read and follow the below safety considerations before using.
For your safety, read and follow the considerations written in the instruction manual, other manuals and Autonics website.
Keep this instruction manual in a place where you can find easily.
The specifications, dimensions, etc are subject to change without notice for product improvement Some models may be discontinued without notice.
Follow Autonics website for the latest information.

Safety Considerations

  • Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
  •  symbol indicates caution due to special circumstances in which hazards may occur.

Warning Failure to follow instructions may result in serious injury or death

  1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss.(e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) Failure to follow this instruction may result in personal injury, economic loss or fire.

  2. Do not use the unit in the place where flammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact or salinity may be present. Failure to follow this instruction may result in explosion or fire.

  3. Install on a device panel to use.
    Failure to follow this instruction may result in electric shock.

  4. Do not connect, repair, or inspect the unit while connected to a power source.
    Failure to follow this instruction may result in fire or electric shock.

  5. Check ‘Connections’ before wiring.
    Failure to follow this instruction may result in fire.

  6. Do not disassemble or modify the unit.
    Failure to follow this instruction may result in fire or electric shock.

Caution Failure to follow instructions may result in injury or product damage

  1. When connecting the power input and relay output, use AWG 20 (0.50 mm2) cable or over and tighten the terminal screw with a tightening torque of 1.0 N m.
    When connecting the sensor input and communication cable without dedicated cable, use AWG 28 to 16 cable and tighten the terminal screw with a tightening torque of 1.0 N m.
    Failure to follow this instruction may result in fire or malfunction due to contact failure.

  2. Use the unit within the rated specifications.
    Failure to follow this instruction may result in fire or product damage

  3. Use a dry cloth to clean the unit, and do not use water or organic solvent.
    Failure to follow this instruction may result in fire or electric shock.

  4. Keep the product away from metal chip, dust, and wire residue which flow into the unit.
    Failure to follow this instruction may result in fire or product damage.

Cautions during Use

  • Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected accidents.

  • Check the polarity of the terminals before wiring the temperature sensor. For RTD temperature sensor, wire it as 3-wire type, using cables in same thickness and length.
    For thermocouple (TC) temperature sensor, use the designated compensation wire for extending wire.

  • Keep away from high voltage lines or power lines to prevent inductive noise. In case installing power line and input signal line closely, use line filter or varistor at power line and shielded wire at input signal line. Do not use near the equipment which generates strong magnetic force or high frequency noise.

  • Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.

  • Do not use the unit for other purpose (e.g. voltmeter, ammeter), but temperature controller.

  • 12-24 VDC ****power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.

  • Make a required space around the unit for radiation of heat. For accurate temperature measurement, warm up the unit over 20 min after turning on the power.

  • Install a surge absorber at each end of inductive load coil when controlling high-capacity power relay or inductive load (e.g. magnet).

  • Make sure that power supply voltage reaches to the rated voltage within 2 sec after supplying power.

  • Do not wire to terminals which are not used.

  • This unit may be used in the following environments.
    – Indoors (in the environment condition rated in ‘Specifications’)
    – Altitude Max. 2,000 m
    – Pollution degree 2
    – Installation category II

Ordering Information

This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website .

Autonics T3 T4 Series 1 Channel Digital Temperature Indicators - Ordering
Information

  1. Digit
    3: 3 digit
    4: 4 digit

  2. Size
    N: DIN W 48 × H 24 mm
    Y: DIN W 72 × H 36 mm
    W: DIN W 96 × H 48 mm
    S: DIN W 48 × H 48 mm (8 pin plug type)
    M: DIN W 72 × H 72 mm
    H: DIN W 48 × H 96 mm
    L: DIN W 96 × H 96 mm

  3. Power supply
    X: 12-24 VDC
    4: 100-240 VAC
    50/60 Hz

  4. Input type and using range

PN| Input| Using range| T3NI| T4YI
T4WI| T3SI| T3HI| T4MI
T4LI
---|---|---|---|---|---|---|---
K2| Thermo
-couple| K(CA)| 0 to 200 °C| ◯| | –| –| –
K4| 0 to 400 °C| ◯| –| –| –| –
K8| 0 to 800 °C| ◯| –| ◯| –| –
KA| 0 to 999 °C| ◯| –| –| ◯| –
KC| 0 to 1200 °C| –| ◯| –| –| –
J2| J(IC)| 0 to 200 °C| ◯| –| –| –| –
J4| 0 to 400 °C| ◯| –| ◯| ◯| ◯
J5| 0 to 500 °C| ◯| ◯| –| –| –
RF| R(PR)| 600 to 1600 °C| –| –| –| –| ◯
PO| RTD| DPt100C)| -99.9 to 99.9 °C| ◯| –| –| –| –
PO| -99.9 to 199.9 °C| –| ◯| –| –| ◯
PO| -99 to 199 °C| –| –| –| ◯| –
P1| 0 to 99.9 °C| ◯| –| ◯| –| –
P2| 0 to 200 °C| ◯| –| –| –| –
P4| 0 to 400 °C| ◯| ◯| ◯| ◯| ◯

  • Contact us for temperature unit ℉ model.

Product Components

  • Product (+ bracket)
    [T4YI] Product, bracket × 2

  • Instruction manual

Sold Separately

  • 8 pin socket: PG-8, PS-8 (N)
  • Terminal protection cover: RMA / RHA / RLA Cover

Initial Display When Power is ON
When power is supplied, all display parts turn ON for 1 sec. After displaying model type, it returns to RUN mode.

1. All display| 2. Digit, alarm/option output| 3. Control output, input and temperature range| 4. RUN mode
---|---|---|---
| | |

Errors

Display Description Troubleshooting
Flashes when input sensor is disconnected or sensor is not connected.

Check input sensor status.
| Flashes when PV is higher than input range.| When input is within the rated input range, this display disappears.
| Flashes when PV is lower than input range.

Specifications

Series T3, T4 Series
Power supply 100 – 240 VAC∼ 50/60 Hz ±10% (T3NI: 12 -24 VDC ****±10%)
Power consumption ≤ 5 VA (T3NI: ≤ 1 W)
Input specification Refer to ‘Ordering Information: Input type and using

range’.
Display accuracy 01)| • At room temperature (23 ℃ ±5 ℃): (PV ±0.5% or ±1℃ higher one) ±1 digit
• Out of room temperature range: (PV ±0.5% or ±2 ℃ higher one) ±1 digit
Display type| 7 Segment (red), LED type
Dielectric strength| Between input terminal and power terminal: 2,000 VAC∼ 50/60 Hz for 1 min
Vibration| 0.75 mm amplitude at frequency of 10 to 55 Hz (for 1 min) in each X, Y, Z direction for 2 hours
Insulation resistance| ≥ 100 MΩ (500 VDC ****megger)
Noise immunity| ±2 kV square shaped noise (pulse width 1 ㎲) by noise simulator R-phase, S-phase
Ambient temperature| -10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
Ambient humidity| 35 to 85%RH, storage: 35 to 85%RH (no freezing or condensation)
Accessory| Bracket
Approval|
Unit weight (packaged)| • T3NI: ≈ 25 g (≈ 48 g)
• T4WI: ≈ 140 g (≈ 231 g)
• T3HI: ≈ 137 g (≈ 203 g)
• T4LI: ≈ 185 g (≈ 274 g)
• T4YI: ≈ 123 g (≈ 181 g)
• T3SI: ≈ 80 g (≈ 120 g)
• T4MI: ≈ 137 g (≈ 202 g)

  1. In case of T3NI, T3SI Series and the decimal point display models
    At room temperature (23 ℃ ±5 ℃): (PV ±0.5% or ±2 ℃ higher one) ±1 digit
    Out of room temperature range: (PV ±0.5% or ±3 ℃ higher one) ±1 digit

Dimensions

  • Unit: mm, For the detailed drawings, follow the Autonics website.
  • Below is based on T3SI Series.

■ Panel cut-outAutonics T3 T4 Series 1 Channel Digital Temperature
Indicators - Dimensions

| Body| Panel cut-out
---|---|---
A| B| C| D| E| F| G| H| I| J
T3NI| 48| 24| 4| –| 48| 21| ≥ 55| ≥ 37| |
T4YI| 72| 36| 7| –| 93| 30| ≥ 91| ≥ 40| |
T4WI| 96| 48| 12| –| 100| 45| ≥ 116| ≥ 52| |
T3SI| 48| 48| 10.5| 12.3| 77.8| □ 45| ≥ 65| ≥ 65| |
T3HI| 48| 96| 13| –| 70| 91.5| ≥ 65| ≥ 115| |
T4M1| 72| 72| 11.8| 14.3| 75| □ 67.5| ≥ 90| ≥ 90| |
T4LI| 96| 96| 12.5| –| 70| □ 91.5| ≥ 115| ≥ 115| |

■ Bracket

Autonics T3 T4 Series 1 Channel Digital Temperature Indicators -
Bracket

Connections

Autonics T3 T4 Series 1 Channel Digital Temperature Indicators - Connections
1| Autonics T3 T4
Series 1 Channel Digital Temperature Indicators - Connections
2
---|---

Crimp Terminal Specifications

  • Unit: mm, Use the crimp terminal of follow shape.

|
---|---
Fork crimp terminal| Round crimp terminal

18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan,
Republic of Korea, 48002
www.autonics.com
+82-51-519-3232
sales@autonics.com
DRW170783AB

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Autonics User Manuals

Related Manuals