HALCYON R750 LED Recessed Luminaire Instruction Manual
- June 10, 2024
- HALCYON
Table of Contents
R750 LED Recessed Luminaire
Instruction Manual
INSTALLATION R750
Installation Directions
- Switch off mains power supply
- Connect Dimmable Driver to mains voltage cable (L, N) Do not connect downlight to driver if driver is live. Inrush current from live driver will cause instant downlight failure. Do not switch secondary side.
- Carefully install downlight into pre-cut 092mm hole.
- Turn on mains power and switch on lighting circuit.
Approved Clearances Note:
0mm required but 25mm always recommended for optimum product lifespan through
effective heat dissipation. Example 1:
0mm Approved Height Clearance. Building element abutting rear, insulation
abutting sides of fitting.
Example 2: 0mm Approved Side Clearance. Building element abutting side of
fitting, insulation abutting and covering fitting.
Driver is designed to be covered and abutted with IC / IC-F approved
insulation.
CLASSIFICATION SHEET
Manufacturer / Supplier | Halcyon Lighting Ltd |
---|---|
Product Code | R750 |
Product Type | LED Recessed Luminaire |
Primary Voltage | 220-240V-50/60Hz |
Secondary Voltage | 230mA 36VDC Constant Current |
Wattage | 9.5W |
Ingress Protection Rating | IP54 |
Classification |
continuously exposed to 90°C allowed to abut and cover the luminaire.
| IC-4 — building insulation that can safely be continuously exposed to 90°C
allowed to abut and cover the luminaire.
In the vicinity of the recessed luminaire, use an insulation product that:
(a) Maintains its dimensions and structural integrity when exposed to a
temperature of 90°C; and
(b) Withstands a 30-second needle flame test carried out in accordance with
AS/NZS 60695.11.5 with the flame applied to all surfaces of the sample.
Rear of fitting may abut structural members and building elements. Do not
install through or directly into joist, beam, rafter or ceiling batten.
Side Clearance from heatsink to building element (e.g. timber, joist or
batten)| SCB: 0mm
---|---
Height Clearance from heatsink to building element (e.g. timber, joist or
batten)| HCB: 0mm
Minimum insulation clearance to building element| MIC: 0mm
Recessed luminaires and their associated equipment may pose a risk of fire or
damage to property if not installed and maintained correctly. Halcyon
recommends a clearance of 25mm to building elements for optimum lifespan.
Halcyon IC rated luminaires are completely safe to install in sparked timber
ceiling linings. Halcyon accepts no responsibility if the timber used is not
treated correctly and dries out, crack or warps over time due to the constant
low heat from the aforementioned “IC Rated” LED recessed lighting.
This data sheet contains information necessary to ensure compliance with the
New Zealand Electrical Code of Practice for Installation and Maintenance of
Recessed Luminaires and Associated Equipment AS/NZS 60598.2.2:2001
Cutting of holes prior to receiving goods is entirely at the risk of the
installer.