sonbus SM3102B industrial soil moisture temperature sensor User Manual

June 5, 2024
SONBUS

SM3102B
RS485 industrial soil moisture temperature sensor

sonbus SM3102B industrial soil moisture temperature
sensor User Manual
File Version: V21.9.4

SM3102B uses the standard RS485 bus MODBUS-RTU protocol, easy access to PLC, DCS, and other instruments or systems for monitoring soil moisture, and soil temperature state quantities. The internal use of high-precision sensing core and related devices to ensure high reliability and excellent long-term stability can be customized  S232, RS485, CAN,4-20mA, DC0~5V\10V, ZIGBEE, Lora, WIFI, GPRS and other output methods.

**Technical Parameters

**

 Technical parameter Parameter value
Brand SONBEST
Moisture measuring range 0~100%
Moisture measuring accuracy  ±3%  @25℃
Moisture Temperature range -30℃~80℃
Moisture Temperature accuracy ±0.5℃ @25℃
Communication Interface RS485
Default baud rate 9600 8 n 1
Power DC9~24V 1A
Running temperature -40~80°C
Working humidity 5%RH~90%RH

Product Size

sonbus SM3102B industrial soil moisture temperature sensor -
Fig

How to wiring?

sonbus SM3102B industrial soil moisture temperature sensor -
Fig1

sonbus SM3102B industrial soil moisture temperature sensor -
Fig2 Note: When wiring, first connect the positive and negative poles of the power supply and then connect the signal line.

Application solution

sonbus SM3102B industrial soil moisture temperature sensor -
Fig3

sonbus SM3102B industrial soil moisture temperature
sensor - Fig6Rapid measurement
Choose a suitable measurement location, avoid stones, dig out the top soil according to the depth required for measurement, maintain the original tightness of the underlying soil, hold the sensor vertically into the soil, and do not shake it left and right when inserting to ensure close contact with the soil

Burial survey
Dig a pit with a diameter of about 20cm verti-cally, and insert the steel needle of the sensor into the pit horizontally according to the measurement needs, compact the soil in the pit to ensure close contact with the soil. After the sensor is stable for a period of time, continuous long-term measurement and recording

How to use it?

sonbus SM3102B industrial soil moisture temperature sensor -
Protocol

Communication Protocol
The product uses RS485 MODBUS-RTU standard protocol format, all operation or reply commands are hexadecimal data. The default device address is 1 when the device is shipped, the default baud rate is 9600, 8, n, 1

  1. Read Data (Function id 0x03)

Inquiry frame (hexadecimal), sending example: Query 1# device 1 data, the host computer sends the
command:01 03 00 00 00 02 C4 0B .

Device ID Function id Start Address Data Length CRC16
1 3 0 2 C4 OB

For the correct query frame, the device will respond with data:01 03 04 00 7A 00 00 DB EA, the response format is parsed as follows.

Device ID Function id Data Length Data 1 Data 2 Check Code
1 3 4 79 00 7A DB EA

Data Description: The data in the command is hexadecimal. Take data 1 as an example. 00 79 is converted to a decimal value of 121. If the data magnification is 100, the actual value is 121/100=1.21. Others and so on.
Data Address Table

Address Start Address Description Data type Value range
40001 00 00 soil Moisture Read Only 0-65535
40002 00 01 soil temperature Read Only 0-65535
40101 00 64 model code read/write 0-65535
40102 00 65 total points read/write 1-20
40103 00 66 Device ID read/write 1-249
40104 00 67 baud rate read/write 0-6
40105 00 68 mode read/write 1-4
40106 00 69 protocol read/write 1-10

3 read and modify device address

  1. Read or query device address

If you don’t know the current device address and there is only one device on the bus, you can use the
command FA 03 00 64 00 02 90 5F Query device address.

Device ID Function id Start Address Data Length CRC16
FA 03 00 64 00 02 90 5F

FA is 250 for the general address. When you don’t know the address, you can use 250 to get the real device address, 00 64 is the device model register. For the correct query command, the device will respond, for example, the response data is: 01 03 02 07 12 3A 79, the format of which is as shown in the following table:

Device ID Function id Data Length Data 1 Data 2 Check Code
1 3 4 79 00 7A DB EA

The response should be in the data, the first byte 01 indicates that the real address of the current device is, 55 3C converted to decimal 20182 indicates that the current device’s main model is 21820, the last two bytes 00 01 Indicates that the device has a status quantity.
(2)Change device address
For example, if the current device address is 1, we want to change to 02, the command is:01 06 00 66 00 02 E8 14 .

Device ID Function id Start Address Destination CRC16
01 06 00 66 00 02 E8 14

After the change is successful, the device will return information: 02 06 00 66 00 02 E8 27 , its format  is parsed as shown in the following table:

Device ID Function id Start Address Destination CRC16
01 06 00 66 00 02 E8 27

The response should be in the data, after the modification is successful, the first byte is the new device address. After the general device address is changed, it will take effect immediately. At this time, the user needs to change the query command of the software at the same time.
4 Read and Modify Baud Rate
(1) Read baud rate
The device’s default factory baud rate is 9600. If you need to change it, you can change it according to the following table and the corresponding communication protocol. For example, read the current device’s baud rate ID, the command is:01 03 00 67 00 01 35 D5, and its format is parsed as follows.

Device ID Function id Start Address Data Length CRC16
01 03 00 67 00 01 35 D5

Read the baud rate encoding of the current device. Baud rate encoding: 1 is 2400; 2 is 4800; 3 is 9600; 4 is 19200; 5 is 38400; 6 is 115200.
For the correct query command, the device will respond, for example, the response data is: 01 03 02 00 03 F8 45, the format of which is as shown in the following table:

Device ID Function id Data Length Rate ID CRC16
01 03 02 00 03 F8 45

coded according to baud rate, 03 is 9600, ie the current device has a baud rate of 9600.
(2)Change the baud rate
For example, changing the baud rate from 9600 to 38400, ie changing the code from 3 to 5, thecommand is: 01 06 00 67 00 05 F8 1601 03 00 66 00 01 64 15.

Device ID Function id Start Address Target Baud Rate CRC16
01 03 00 66 00 01 64 15

Change the baud rate from 9600 to 38400, changing the code from 3 to 5. The new baud rate will take effect immediately, at which point the device will lose its response and the baud rate of the device should be queried accordingly. Modified.
5 Read Correction Value
(1) Read Correction Value
When there is an error between the data and the reference standard, we can reduce the display error by adjusting the correction value. The correction difference can be modified to be plus or minus 1000, that is, the value range is 0-1000 or 64535 -65535. For example, when the display value is too small, we can correct it by adding 100. The command is: 01 03 00 6B 00 01 F5 D6 . In the command 100 is hex 0x64 If you need to reduce, you can set a negative value, such as -100, corresponding to the hexadecimal value of
FF 9C, which is calculated as 100-65535=65435, and then converted to hexadecimal to 0x FF 9C. The correction value starts from 00 6B. We take the first parameter as an example. The correction value is read and modified in the same way for multiple parameters.

Device ID Function id Start Address Data Length CRC16
01 03 00 6B 00 01 F5 D6

For the correct query command, the device will respond, for example, the response data is: 01 03 02 00 64 B9 AF, the format of which is as shown in the following table:

Device ID Function id Data Length Data value CRC16
01 03 02 00 64 B9 AF

In the response data, the first byte 01 indicates the real address of the current device, and 00 6B is the first state quantity correction value register. If the device has multiple parameters, other parameters operate in this way. The same, the general temperature, and humidity have this parameter, the light generally does not have this item.
(2)Change correction value For example, the current state quantity is too small, we want to add 1 to its true value, and the current value plus 100 correction operation command is:01 06 00 6B 00 64 F9 FD.

Device ID Function id Start Address Destination CRC16
01 06 00 6B 00 64 F9 FD

After the operation is successful, the device will return information: 01 06 00 6B 00 64 F9 FD, the parameters take effect immediately after a successful change. Disclaimer
This document provides all information about the product, does not grant any license to intellectual property, does not express or imply, and prohibits any other means of granting any intellectual property rights, such as the statement of sales terms and conditions of this product, other issues. No liability is assumed. Furthermore, our company makes no warranties, express or implied, regarding the sale and uof this product, including the suitability for the specific use of the product, the marketability or the
infringement liability for any patent, copyright or other intellectual property rights, etc. Product specifications and product descriptions may be modified at any time without notice.

Contact Us
Company: Shanghai Sonbest Industrial Co., Ltd
Address: Building 8, No.215 Northeast Road, Baoshan District, Shanghai, China
Web: http://www.sonbest.com
SKYPE: soobuu
Email: sale@sonbest.com
Tel: 86-021-51083595 / 66862055 / 66862075 / 66861077

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

SONBUS User Manuals

Related Manuals