sonbus SM3102B industrial soil moisture temperature sensor User Manual
- June 5, 2024
- SONBUS
Table of Contents
SM3102B
RS485 industrial soil moisture temperature sensor
User Manual
File Version: V21.9.4
SM3102B uses the standard RS485 bus MODBUS-RTU protocol, easy access to PLC, DCS, and other instruments or systems for monitoring soil moisture, and soil temperature state quantities. The internal use of high-precision sensing core and related devices to ensure high reliability and excellent long-term stability can be customized S232, RS485, CAN,4-20mA, DC0~5V\10V, ZIGBEE, Lora, WIFI, GPRS and other output methods.
**Technical Parameters
**
Technical parameter | Parameter value |
---|---|
Brand | SONBEST |
Moisture measuring range | 0~100% |
Moisture measuring accuracy | ±3% @25℃ |
Moisture Temperature range | -30℃~80℃ |
Moisture Temperature accuracy | ±0.5℃ @25℃ |
Communication Interface | RS485 |
Default baud rate | 9600 8 n 1 |
Power | DC9~24V 1A |
Running temperature | -40~80°C |
Working humidity | 5%RH~90%RH |
Product Size
How to wiring?
Note: When wiring, first connect the positive and negative poles of the power supply and then connect the signal line.
Application solution
Rapid measurement
Choose a suitable measurement location, avoid stones, dig out the top soil
according to the depth required for measurement, maintain the original
tightness of the underlying soil, hold the sensor vertically into the soil,
and do not shake it left and right when inserting to ensure close contact with
the soil
Burial survey
Dig a pit with a diameter of about 20cm verti-cally, and insert the steel
needle of the sensor into the pit horizontally according to the measurement
needs, compact the soil in the pit to ensure close contact with the soil.
After the sensor is stable for a period of time, continuous long-term
measurement and recording
How to use it?
Communication Protocol
The product uses RS485 MODBUS-RTU standard protocol format, all operation or
reply commands are hexadecimal data. The default device address is 1 when the
device is shipped, the default baud rate is 9600, 8, n, 1
- Read Data (Function id 0x03)
Inquiry frame (hexadecimal), sending example: Query 1# device 1 data, the host
computer sends the
command:01 03 00 00 00 02 C4 0B .
Device ID | Function id | Start Address | Data Length | CRC16 |
---|---|---|---|---|
1 | 3 | 0 | 2 | C4 OB |
For the correct query frame, the device will respond with data:01 03 04 00 7A 00 00 DB EA, the response format is parsed as follows.
Device ID | Function id | Data Length | Data 1 | Data 2 | Check Code |
---|---|---|---|---|---|
1 | 3 | 4 | 79 | 00 7A | DB EA |
Data Description: The data in the command is hexadecimal. Take data 1 as an
example. 00 79 is converted to a decimal value of 121. If the data
magnification is 100, the actual value is 121/100=1.21. Others and so on.
Data Address Table
Address | Start Address | Description | Data type | Value range |
---|---|---|---|---|
40001 | 00 00 | soil Moisture | Read Only | 0-65535 |
40002 | 00 01 | soil temperature | Read Only | 0-65535 |
40101 | 00 64 | model code | read/write | 0-65535 |
40102 | 00 65 | total points | read/write | 1-20 |
40103 | 00 66 | Device ID | read/write | 1-249 |
40104 | 00 67 | baud rate | read/write | 0-6 |
40105 | 00 68 | mode | read/write | 1-4 |
40106 | 00 69 | protocol | read/write | 1-10 |
3 read and modify device address
- Read or query device address
If you don’t know the current device address and there is only one device
on the bus, you can use the
command FA 03 00 64 00 02 90 5F Query device address.
Device ID | Function id | Start Address | Data Length | CRC16 |
---|---|---|---|---|
FA | 03 | 00 64 | 00 02 | 90 5F |
FA is 250 for the general address. When you don’t know the address, you can use 250 to get the real device address, 00 64 is the device model register. For the correct query command, the device will respond, for example, the response data is: 01 03 02 07 12 3A 79, the format of which is as shown in the following table:
Device ID | Function id | Data Length | Data 1 | Data 2 | Check Code |
---|---|---|---|---|---|
1 | 3 | 4 | 79 | 00 7A | DB EA |
The response should be in the data, the first byte 01 indicates that the real
address of the current device is, 55 3C converted to decimal 20182 indicates
that the current device’s main model is 21820, the last two bytes 00 01
Indicates that the device has a status quantity.
(2)Change device address
For example, if the current device address is 1, we want to change to 02, the
command is:01 06 00 66 00 02 E8 14 .
Device ID | Function id | Start Address | Destination | CRC16 |
---|---|---|---|---|
01 | 06 | 00 66 | 00 02 | E8 14 |
After the change is successful, the device will return information: 02 06 00 66 00 02 E8 27 , its format is parsed as shown in the following table:
Device ID | Function id | Start Address | Destination | CRC16 |
---|---|---|---|---|
01 | 06 | 00 66 | 00 02 | E8 27 |
The response should be in the data, after the modification is successful, the
first byte is the new device address. After the general device address is
changed, it will take effect immediately. At this time, the user needs to
change the query command of the software at the same time.
4 Read and Modify Baud Rate
(1) Read baud rate
The device’s default factory baud rate is 9600. If you need to change it, you
can change it according to the following table and the corresponding
communication protocol. For example, read the current device’s baud rate ID,
the command is:01 03 00 67 00 01 35 D5, and its format is parsed as follows.
Device ID | Function id | Start Address | Data Length | CRC16 |
---|---|---|---|---|
01 | 03 | 00 67 | 00 01 | 35 D5 |
Read the baud rate encoding of the current device. Baud rate encoding: 1 is
2400; 2 is 4800; 3 is 9600; 4 is 19200; 5 is 38400; 6 is 115200.
For the correct query command, the device will respond, for example, the
response data is: 01 03 02 00 03 F8 45, the format of which is as shown in the
following table:
Device ID | Function id | Data Length | Rate ID | CRC16 |
---|---|---|---|---|
01 | 03 | 02 | 00 03 | F8 45 |
coded according to baud rate, 03 is 9600, ie the current device has a baud
rate of 9600.
(2)Change the baud rate
For example, changing the baud rate from 9600 to 38400, ie changing the code
from 3 to 5, thecommand is: 01 06 00 67 00 05 F8 1601 03 00 66 00 01 64 15.
Device ID | Function id | Start Address | Target Baud Rate | CRC16 |
---|---|---|---|---|
01 | 03 | 00 66 | 00 01 | 64 15 |
Change the baud rate from 9600 to 38400, changing the code from 3 to 5. The
new baud rate will take effect immediately, at which point the device will
lose its response and the baud rate of the device should be queried
accordingly. Modified.
5 Read Correction Value
(1) Read Correction Value
When there is an error between the data and the reference standard, we can
reduce the display error by adjusting the correction value. The correction
difference can be modified to be plus or minus 1000, that is, the value range
is 0-1000 or 64535 -65535. For example, when the display value is too small,
we can correct it by adding 100. The command is: 01 03 00 6B 00 01 F5 D6 . In
the command 100 is hex 0x64 If you need to reduce, you can set a negative
value, such as -100, corresponding to the hexadecimal value of
FF 9C, which is calculated as 100-65535=65435, and then converted to
hexadecimal to 0x FF 9C. The correction value starts from 00 6B. We take the
first parameter as an example. The correction value is read and modified in
the same way for multiple parameters.
Device ID | Function id | Start Address | Data Length | CRC16 |
---|---|---|---|---|
01 | 03 | 00 6B | 00 01 | F5 D6 |
For the correct query command, the device will respond, for example, the response data is: 01 03 02 00 64 B9 AF, the format of which is as shown in the following table:
Device ID | Function id | Data Length | Data value | CRC16 |
---|---|---|---|---|
01 | 03 | 02 | 00 64 | B9 AF |
In the response data, the first byte 01 indicates the real address of the
current device, and 00 6B is the first state quantity correction value
register. If the device has multiple parameters, other parameters operate in
this way. The same, the general temperature, and humidity have this parameter,
the light generally does not have this item.
(2)Change correction value For example, the current state quantity is too
small, we want to add 1 to its true value, and the current value plus 100
correction operation command is:01 06 00 6B 00 64 F9 FD.
Device ID | Function id | Start Address | Destination | CRC16 |
---|---|---|---|---|
01 | 06 | 00 6B | 00 64 | F9 FD |
After the operation is successful, the device will return information: 01 06
00 6B 00 64 F9 FD, the parameters take effect immediately after a successful
change. Disclaimer
This document provides all information about the product, does not grant any
license to intellectual property, does not express or imply, and prohibits any
other means of granting any intellectual property rights, such as the
statement of sales terms and conditions of this product, other issues. No
liability is assumed. Furthermore, our company makes no warranties, express or
implied, regarding the sale and uof this product, including the suitability
for the specific use of the product, the marketability or the
infringement liability for any patent, copyright or other intellectual
property rights, etc. Product specifications and product descriptions may be
modified at any time without notice.
Contact Us
Company: Shanghai Sonbest Industrial Co., Ltd
Address: Building 8, No.215 Northeast Road, Baoshan District, Shanghai, China
Web: http://www.sonbest.com