Stalgast 880700V02 Lacquered Cooling Cabinet Instruction Manual

June 10, 2024
stalgast

Stalgast 880700V02 Lacquered Cooling Cabinet

Stalgast-880700V02-Lacquered-Cooling-Cabinet

Product Information

Cooling/Freezing Cabinet

Model Numbers

  • 880700V02
  • 880701V02
  • 881400V02
  • 881401V02

Technical Specifications

  • Power Supply: 230V/50Hz
  • Power Consumption: 353W – 510W
  • Temperature Range: -10°C to +8°C
  • Dimensions (WxDxH):
    • 680x810x2000mm – Model 880700V02, 880701V02
    • 1340x845x2000mm – Model 881400V02, 881401V02
  • Climatic Class: 4
  • Weight: 135kg – 180kg

Features

  • Eco-friendly refrigerant: R600a or R290
  • Net Volume: 376L – 770L (depending on model)
  • Cooling and freezing functions available (depending on model)
  • Control panel with various settings including temperature adjustment and defrost cycle control.

Transport and Storage

The device is protected with a protective foil, placed on a wooden pallet, packed in a cardboard box, and secured with straps.

Installation

The device should be installed as a freestanding unit against a wall. Before connecting the device to the electrical network,ensure that the voltage and frequency values on the identification plate match those at the installation site. If the device is installed in a high-humidity environment, a drip tray may be required to collect condensation.

Product Usage Instructions

  1. Ensure that the device is properly installed and connected to the electrical network.
  2. Use the control panel to set the desired temperature range for cooling or freezing (depending on model).
  3. Monitor the temperature display to ensure that the device is maintaining the desired temperature range.
  4. If the device is equipped with a defrost cycle, set the defrost cycle control according to your needs.
  5. If any issues arise with the device, consult the user manual for troubleshooting or contact a qualified technician for assistance.

Thank you for the purchase of our product. Please read this manual carefully before starting to operate the appliance. All rights reserved. No part of this manual may be reproduced by photocopy, printing or in any other way without prior consent from the manufacturer. Photographs and drawings are furnished by way of example and can vary from the pur-chased appliance.

NOTE: Keep the manual in a safe place accessible for the personnel.
The manufacturer reserves the right to change technical parameters of the appliance at any time without advance notice.

SAFETY INSTRUCTIONS

  • Incorrect operation and improper use can result in serious damage to the appliance or personal injury.
  • Use this appliance solely for its intended use as described in this manual.
  • The manufacturer cannot be held liable for any damage caused by incorrect operation and improper use of the ap-pliance.
  • During operating keep the appliance and the plug away from water or other liquids. In case the appliance, as a result of carelessness, has been immersed in water or flooded by water immediately unplug the appliance from the wall socket and prior to further use contact a qualified technician for examination.
  • Failure to observe instructions enclosed in this manual may result in the hazard of injury or death.
  • Do not let unauthorized opening of the housing of the appliance.
  • Do not insert any foreign objects into the housing of the appliance.
  • Do not touch the plug and the power cord with damp hands.
  • Regularly check the condition of the plug and the cord. If the power cord or the plug is damaged they should be replaced by the Authorized Technical Service personnel.
  • In case the appliance is dropped or damaged in any other way before turning it on always contact the Authorized Technical Service for examination and repair.
  • Any repairs and work on the appliance should be carried out solely by Authorized Technical Service, never by the end user as unauthorized tampering could prove highly dangerous for the user.
  • Do not let the cord hang over or touch hot surfaces or sharp edges. Keep the cord away from naked fire. When disconnecting the appliance from the wall socket, pull on the plug, never on the cord.
  • Do not let the cord (or extension cord) be inadvertently pulled on or tripped over.
  • Check the operation of the appliance during usage.
  • This appliance can be used by children in the age of eight and more or by persons with reduced physical, sensory or mental capabilities or lack of knowledge and experience in operating of the appliance, if they have been given supervision or instruction concerning use of the appliance in a safe way by a person responsible for their safety and they understand the hazards involved. Children should not play with the appliance. Children should not perform cleaning or maintenance of the appliance without supervision.
  • Always switch off the appliance and unplug the power cord from the wall socket when the appliance is not in use and prior to cleaning operations. The disconnected plug should be sited in a visible place.
  • Warning: The appliance’s power will remain ON unless unplugged.
  • Turn off the appliance before pulling the plug out of the wall socket.
  • Never pull the appliance on the cord.
  • It is prohibited to store any explosive substances such as aerosol / flammable gas cans in the appliance.
  • WARNING: Do not block or cover any ventilation openings in the equipment casing or in the built-in structure.
  • WARNING: Do not use mechanical or any other means to accelerate the defrosting process other than recommended by the manufacturer.
  • WARNING : Protect the refrigeration system from damage.
  • WARNING: Do not use any type of electrical equipment other than recommended by the manufacturer inside the food storage chamber.

DESCRIPTION AND INTENDED USE OF THE APPLIANCE

  • the cooling cabinet is intended for short-term storage of pre-chilled food products.
  • the freezing cabinet are intended for storage of pre-frozen food products
  • the housing of the appliance is made of stainless steel
  • forced air circulation
  • digital controller with temperature display
  • automatic defrosting

Product TECHNICAL SPECIFICATION

Model 880700V02 880701V02 881400V02 881401V02
Voltage (V/Hz) 230 / 50
Power (W) 353 510 450 710
Temperature range (oC) -2 / +8 -10 / -20 -2 / +8 -10 / -20
Dimensions (WxDxH) (mm) 680x810x2000 680x810x2000 1340x845x2000

1340x845x2000
**Climate class *| 4| 4| 4| 4
Weight** (kg)| 135| 135| 180| 180

  • 4 – to + 30 °C / relative humidity 55 %
  • 5 – to + 40 °C / relative humidity 40 %

Stalgast-880700V02-Lacquered-Cooling-Cabinet-1

The device contains R290 or R600a coolant – natural, ecological, flammable gas.
Take special care when transporting and installing the device to avoid damaging the cooling circuit.
If a leak is revealed, refrain from using devices/items that could cause sparks or fire and ventilate the room. To avoid the formation of a flammable gas mixture in the event of a leak from the refrigeration system, install the device in a room with area of 1m3 per every 8 g of the coolant. The amount of coolant is given in „TECHNICAL DATA / PRODUCT CARD” and on the nameplate.

PRODUCT CARD

Model 880700v02 880701v02 881400v02 881401v02
Intended use storage storage storage storage
Operating temperature cooling freezing cooling freezing
Category vertical vertical vertical vertical
Refrigerants: R600a, GWP=3 R290, GWP=3 R290, GWP=3

R290, GWP=3
Parameter| Value
Annual energy consumption AEC (kWh)| 434| 2054| 675| 3165
Coefficient of energetic efficiency EEI| 35.41| 61.78| 36.02| 60.1
Net capacity V N (L)| 376| 376| 770| 770
(where applicable)
Refrigeration capacity V NRef (L)| 376| 0| 770| 0
Freezing capacity V NFrz (L)| 0| 376| 0| 770
Amount of refrigerant (kg)| 0.085| 0.1| 0.11| 0.15

TRANSPORT AND STORAGE

The appliance is protected with a protective film, placed on a wooden pallet, packed in a cardboard box and secured with stripes.

  • packaged appliance should be stored in a covered warehouse at an ambient temperature of 0 °C / + 55 °C and humidity of 30 – 95 %;
  • it is forbidden to stack appliances;
  • read the data on the appliance rating plate. In case of damage or loss of the rating plate it should be replaced immediately;
  • do not unscrew the safety guards;
  • after unpacking the appliance, carefully remove the protective film and other elements protecting the appliance during transport;
  • while lifting the appliance with a lift, position the lift on the outside of the frame;
  • transport the appliance and store it exclusively in a vertical position. Never place the appliance on its side or upside down, because it can damage the cooling system (not subject to warranty repair);
  • after transporting or moving the appliance wait 2 hours before starting it;
  • do not place the appliance in the vicinity of flammable products, outdoors or in a place subject to direct sunlight exposure.

Product INSTALLATION

POSITIONING OF THE APPLIANCE
The appliance should be placed in a dry, adequately ventilated room. In order to ensure proper work do not place the appliance near a heat source and do not expose it to direct sunlight. The optimal temperature range in the room in which the appliance operates is between: + 16 °C and + 35 °C.
If you install the appliance in a room with high humidity level, you may need to buy an additional tray for condensed water. Avoid placing the appliance in rooms with a high chlorine and acids content in the air (e.g. at a pool), as this may cause corrosion of the surface made of stainless steel.
The cooling cabinet is prepared to be positioned at a wall as a free-standing appliance.

ELECTRICAL CONNECTION
The appliance should be connected to an AC power source.
Before connecting the appliance to the mains, make sure that the voltage and frequency values given on the rating plate of the appliance correspond with the voltage and frequency values at the place of installation.
The electrical outlet should be properly earthed and equipped with a differential current protection device in accordance with legal provisions in force.

CONTROL PANEL OPTION 1

Description:

Indicator light Symbol Status Meaning
Settings indicator light SET The light is on Parameter setting
The light is off Measurement and control
The light flashes Checking parameters, entering a

password

Refrigeration indicator light| **| The light is on| Refrigeration
The light is off| Refrigeration stopped
The light flashes| Refrigeration delay enabled
Defrosting indicator light| **| The light is on| Defrosting
The light is off| Defrosting stopped

DESCRIPTION OF PARAMETERS

Code Function Setting range Default value Unit

F01

| Menu password| 00: butt 00-99     functions lock deleting| 55| NO
F02| Setting temperature value| -40 ~+50| 2| °C
F03| Setting temperature difference| 1 – 15| 4| °C
F04| Compressor activation time

delay

| 1 – 15| 3| min.
F05| Interior temperature calibration| -5 ~ +5| 0| °C
F06| Maximum defrosting time| 1 – 60| 20| min.
F07| Defrosting cycle| 1 – 30 units| 12| 1 unit = 30 min.
F08| Defrosting termination temperature| -20 ~+30| 7| °C
F09| Evaporator sensor activation or no activation| 00: not active

01: active

| 1| NO

BUTTONS FUNCTIONS

Buttons Function
SET Press to enter the password; Setting parameters mode; Changing between

the menu and the parameter mode.
| Press to check the value of the set temperature; Selection of the menu functions; Changing the setting of parameters and a password.
| Press to check the value of the evaporator sensor; Selection of the menu functions; Changing the setting of parameters and a password.
| Exit from the parameter setting mode; Manual activation or stopping of defrosting.

Temperature measurement and control mode

  • Press the „SET” button and hold it for 3 seconds.
    In case the keypad password has been set to „0”, the settings indicator light is on, the display shows „F1” code from the menu, there is no password confirmation and you should directly enter the menu mode to set the parameter.
    If the keypad password has not been set to „0”, the indicator light flashes and the display shows „00”, press the „ ” and „ ”, buttons to enter the password, then press the „SET” button to confirm the password. If the password is correct, the system will go to the settings menu. If the password is not correct the settings indicator light will go off and the system will return to the normal temperature measurement and control mode.

Checking parameter settings:
Push the button „ ”. The settings indicator light „SET” starts to flash and the display shows the set temperature value.
Push the button ”. The settings indicator light „SET” starts to flash and the display shows the temperature value of the evaporator sensor.
After entering the settings menu, press the „ ”button and the „ ”, button to select the desired menu function (from F01 to F09).

After selecting the desired menu function, press the „SET” button to set the parameter value, press the „ ” and „ ” „ and select the desired value of the parameter, then press the” SET „button again to return to the function selection from the menu.

In the settings selection mode, press the „ ” button or do not press any buttons for 30 seconds, the system will save the set parameters values and exit the parameters setting mode.
Press the „ ” button and hold it for 3 seconds to manually activate or terminate defrosting.

COMPRESSOR OPERATION AND DEFROST FUNCTION CONTROL

  • Compressor
    The compressor will be activated when the time of its activation delay expires if the temperature sensor indicates that the temperature is higher than „set temperature value + temperature difference value „.
    The compressor will stop working when the temperature sensor detects that the temperature is lower than the set tem-perature value.

  • Defrosting:
    The system will start defrosting in accordance with the defrosting cycle set or when manual defrosting is activated.
    If the evaporator sensor has been activated and the temperature detected by the evaporator sensor is higher than the temperature of the defrosting termination, it is not possible to activate the defrosting function manually.
    Defrosting will be terminated when the temperature detected by the evaporator sensor reaches the value equal to the set value of the defrosting termination temperature or when the set defrosting time has elapsed or when the defrosting has been turned off manually.
    If the evaporator sensor has not been activated or if an error occurs, defrosting will be interrupted when the set defrosting time elapses or the defrosting is turned off manually.

ERROR MESSAGES

Message Cause Solution
E1 Chamber sensor error Contact the Technical Service to replace the

chamber sensor. After the fault has been repa- ired the system will again calculate the compressor activation delay time.
E2| Evaporator sensor error

The temperature of defrosting termination is incorrect

| Contact the Technical Service to replace the evaporator sensor.

CONTROL PANEL OPTION 2

Button Function

| Used to display the setting, in the programming cycle is used to select the parameter or confirm the operation.
| With this arrow you can display the last alarm, in the programming cycle, you can scroll through the parameters or increase the displayed value.
**| The arrow turned down is used to display the last alarm, during the programming cycle, to scroll through the parameters, or to decrease the displayed setting.
| This button is used to manually start the defrosting process.
Combinations of buttons
**
| Used to lock and unlock the keyboard.
| Used to enter the programming mode.
| Return to display the temperature in the chamber.

DESCRIPTION OF INDICATOR LIGHTS

| On| The compressor is on.
---|---|---
| Flashes| The programming mode has been activated.
| On| The defrosting has been activated.
| Flashes| Programming mode, dripping in progress.
o F

o C

| On| Fahrenheit degrees Celsius degrees

HOW TO CHECK THE DURATION OF THE ALARM AND THE MINIMUM AND MAXIMUM TEMPERATURE

If an alarm symbol appears on the display, to see the type of alarm, min (max) temperature, the duration of the alarm,proceed as follows

  1. Press the arrow up or arrow down button

  2. The display will show the following message „HAL” for high-temperature alarm, „LAL” for low-temperature alarm.
    Then „tIM” (time) displays the duration of the alarm in minutes

  3. The next step is to return to the temperature display

DELETING CONSTANTLY OCCURRING SAVED ALARM

  1. Press down the SET button and hold it for more than 3 seconds, in the meantime the saved alarm is displayed (the display will show the rSt message);
  2. To confirm the operation, „rSt” message will start flashing and the normal temperature will be displayed

HOW TO CHECK THE SETTINGS
Press the „SET” button and immediately release it, the display will show the settings. After pressing and releasing the„SET” button or hold it down for 5 seconds to display the values of the sensor again.

HOW TO CHANGE THE SETTINGS

  1. Press the „SET” button and hold it down for more than 2 seconds to change the values;
  2. The value of the settings will be displayed and the LED indicator light will start flashing
  3. To change the settings, press or and hold it down for 10 seconds
  4. To save the new settings, press the „SET” button and hold it down for 10 seconds.

STARTING MANUAL DEFROSTING
To start manual defrosting process, press the „SET” button and hold it down for 2 seconds, that will activate the defrost process.

CHANGING OF PARAMETERS VALUE
To change the parameters values, proceed as follows:

  1. Enter the programming mode by pressing the SET button and the arrow down button and holding them down for 3 seconds and the „SET” button will start flashing;
  2. Select the parameter
  3. Press he „SET” button to display the values
  4. Use the up or down arrows to change the settings;
  5. Press the „SET” button to save the new parameters;
  6. To exit, press the SET + arrow up buttons or wait for 15 seconds without pressing any buttons.

LOCKING OF THE KEYBOARD

  1. Press the buttons arrow up and arrow down and hold them down for 3 seconds.
  2. The POF message will appear on the display and the keyboard will be locked. Only information about maximum and minimum temperature can be displayed in this mode.
  3. If any button is pressed and held down for 3 seconds POF message will be displayed.

UNLOCKING OF THE KEYBOARD
Press the up and down arrow buttons and hold them down for 3 seconds until you see the „Pon”. message.

CONTINUOUS MODE
If the defrosting process is not enabled, the continuous mode can be activated by pressing and holding down the arrow up button for 3 seconds. The compressor will start operating in continuous mode until the Cct parameter setting is reached.
This process can be terminated before it ends by using the arrow up button and holding it down for 3 seconds.

ALARMS

Message Cause
P1 Chamber sensor error
P2 Evaporator sensor error
HA Maximum temperature reached
LA Minimum temperature alarm

CONTROL PANEL OPTION 3

**| Display of the setpoint, in the programming mode, parameter selection and confirmation of changes
---|---

| Start manual defrost

| In programming mode, scrolling through the parameter list or increasing the value.
**
| In programming mode, scrolling through the parameter list or decreasing the value.
Button combinations

+| Display of the setpoint, in the programming mode, parameter selection and confirmation of changes
+| Start manual defrost
+| In programming mode, scrolling through the parameter list or increasing the value.

DESCRIPTION OF INDICATOR LIGHTS

Symbol Mode Meaning
ON Defrost active
FLASHING Dripping active
ON Compressor active
FLASHING Activation of short cycle protection (AC parameter)
ON Activation of the fan output
FLASHING Delayed fan activation after defrost
ON Units of measure
FLASHING Programming mode
ON Units of measure
FLASHING Programming mode

HOW TO DISPLAY THE SETPOINT VALUE

  1. Press the SET button briefly, the setpoint appears on the screen.
  2. Press the SET button briefly or wait 5 seconds to return to the standard

HOW TO CHANGE THE SETPOINT

  1. Hold down the SET button for 2 seconds to change the setpoint value;
  2. The value of the setpoint appears on the screen, the „C” or „F” LED
  3. To change the value, use the buttons **or .**
  4. To confirm the changes, press the SET button or wait 10s

HOW TO RUN A MANUAL DEFROST

Press the for at least 2 sec – manual defrosting will start

HOW TO CHANGE THE PARAMETER VALUE
To change the parameter value:

  1. Go to programming by simultaneously pressing the buttons SET+ ****for 3 sec (“°C” or “°F” LED flashes).
  2. Select the desired parameter. Press “SET” to display its value
  3. Change the value with the and/or .
  4. Press “SET” to confirm the entered value and move on to the next parameter.

To finish: simultaneously press SET+ or wait 15 seconds without pressing buttons.

Note: The value is stored even in case of exit after 15 seconds idle.

LOCKING THE KEYBOARD

  1. Press and hold for at least 3 seconds the buttons and.
  2. An „OFF” message will appear indicating that the keypad is locked. Pressing a button for more than 3 seconds will cause the OFF message to appear.

UNLOCKING THE KEYBOARD

Press the buttons and hold for at least 3 seconds the buttons and ,the „on” message will.

ALARM

Alarm Cause Outputs
„P1” Room sensor error Compressor output depending on „Cy” and „Cn”
„P2” Evaporator sensor error Defrosting completed by timeout
„HA” Maximum temp. alarm Outputs without modifications
--- --- ---
„LA” Minimum temp. alarm Outputs without modifications
“EA” External alarm Outputs without modifications
“CA” Serious external alarm Disable all outputs
“dA” Opening the door Restarting the compressor and fan

CAUTION! In the event of the errors mentioned above, contact the service immediately and provide the alarm symbol.

CLEANING AND MAINTENANCE

Note: Before starting any maintenance procedure, always disconnect the appliance from the power supply.
The appliance should be washed with water and dishwashing liquid. It is not recommended to clean the appliance with detergents, because they can damage the walls of the cabinet. Plastic parts of the appliance can be washed with water at the maximum temperature of 85 °C.
During daily cleaning of the appliance, remember to thoroughly clean the gasket from crumbs and sticky substances,because they can damage it.
The ventilation grate of the compressor (located on the back of the appliance) should be cleaned regularly, as dirt and dust may block free air circulation.

PROCEDURE IN THE EVENT OF POWER FAILURE
In case the appliance is disconnected from the power supply (both due to a failure or due to accidental removing of the plug from the electric socket), the element controlling the work of the compressor will cause that the restarted appliance will operate according to the current temperature control knob setting.

DISPOSAL OF THE OLD APPLIANCE
Information for users on the rules concerning proper disposal of electrical and electronic equipment at the end of its life.

  • Leave your old equipment in the shop where you purchase a new appliance. Each store is obliged to accept old equipment free of charge if you buy there the new equipment of the same type and in the same quantity. The only condition is to deliver the old equipment to the store at your expense.
  • Dispose of your old equipment at a collection point. Information about the location of the nearest collection point can be found on the local website or the notice board of the municipal office.
  • Leave the equipment at a service point. If the repair of the equipment is unprofitable or impossible for technical reasons, the service is obliged to accept this appliance free of charge.
  • Return the used equipment at the end of its life without leaving your home. If you do not have the time or ability to deliver your equipment to the collection point, you can use the services of specialized companies.
  • Remember! Do not dispose of used equipment together with regular waste.

An illegal or incorrect disposal of the product will lead to high penalties being imposed.

The symbol of a crossed-out rubbish bin on the product, its packaging or its instruction manual means that at the end of its life the product must not be disposed of with regular waste. The user is obliged to deliver their used equipment to a designated collection point for proper processing.

GUARANTEE
The dealer of the appliance is liable under the guarantee.
The guarantee does not cover any damage resulting from the build-up of limescale inside the appliance. The guarantee also does not cover: damage caused by external forces such as atmospheric discharge, voltage change, incorrect setting of electrical voltage, power supply from unsuitable power outlet, any mechanical, thermal, chemical damage and defects resulting from them.
Furthermore, the guarantee does not cover the replacement of exhaustible parts, namely: light bulbs, rubber elements,heating elements damaged by limescale, glass and other elements that are exposed to any form of wear or usage, for example; burners, rubber units as well as any breakdowns or mechanical damage of the appliance elements caused by incorrect storage, transport, maintenance, installation or operation.

Stalgast Sp. z o.o.
Plac Konesera 9, Budynek O, 03-736 Warszawa
tel.: 22 517 15 75 fax: 22 517 15 77
www.stalgast.com
email: stalgast@stalgast.com

Tel.: +48 22 509 30 77
export@stalgast.com
www.stalgast.eu

References