Stalgast 880700V02 Lacquered Cooling Cabinet Instruction Manual
- June 10, 2024
- stalgast
Table of Contents
- Stalgast 880700V02 Lacquered Cooling Cabinet
- Product Information
- Technical Specifications
- Features
- Installation
- Product Usage Instructions
- SAFETY INSTRUCTIONS
- Product TECHNICAL SPECIFICATION
- PRODUCT CARD
- TRANSPORT AND STORAGE
- Product INSTALLATION
- CONTROL PANEL OPTION 1
- CONTROL PANEL OPTION 2
- CLEANING AND MAINTENANCE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Stalgast 880700V02 Lacquered Cooling Cabinet
Product Information
Cooling/Freezing Cabinet
Model Numbers
- 880700V02
- 880701V02
- 881400V02
- 881401V02
Technical Specifications
- Power Supply: 230V/50Hz
- Power Consumption: 353W – 510W
- Temperature Range: -10°C to +8°C
- Dimensions (WxDxH):
- 680x810x2000mm – Model 880700V02, 880701V02
- 1340x845x2000mm – Model 881400V02, 881401V02
- Climatic Class: 4
- Weight: 135kg – 180kg
Features
- Eco-friendly refrigerant: R600a or R290
- Net Volume: 376L – 770L (depending on model)
- Cooling and freezing functions available (depending on model)
- Control panel with various settings including temperature adjustment and defrost cycle control.
Transport and Storage
The device is protected with a protective foil, placed on a wooden pallet, packed in a cardboard box, and secured with straps.
Installation
The device should be installed as a freestanding unit against a wall. Before connecting the device to the electrical network,ensure that the voltage and frequency values on the identification plate match those at the installation site. If the device is installed in a high-humidity environment, a drip tray may be required to collect condensation.
Product Usage Instructions
- Ensure that the device is properly installed and connected to the electrical network.
- Use the control panel to set the desired temperature range for cooling or freezing (depending on model).
- Monitor the temperature display to ensure that the device is maintaining the desired temperature range.
- If the device is equipped with a defrost cycle, set the defrost cycle control according to your needs.
- If any issues arise with the device, consult the user manual for troubleshooting or contact a qualified technician for assistance.
Thank you for the purchase of our product. Please read this manual carefully before starting to operate the appliance. All rights reserved. No part of this manual may be reproduced by photocopy, printing or in any other way without prior consent from the manufacturer. Photographs and drawings are furnished by way of example and can vary from the pur-chased appliance.
NOTE: Keep the manual in a safe place accessible for the personnel.
The manufacturer reserves the right to change technical parameters of the
appliance at any time without advance notice.
SAFETY INSTRUCTIONS
- Incorrect operation and improper use can result in serious damage to the appliance or personal injury.
- Use this appliance solely for its intended use as described in this manual.
- The manufacturer cannot be held liable for any damage caused by incorrect operation and improper use of the ap-pliance.
- During operating keep the appliance and the plug away from water or other liquids. In case the appliance, as a result of carelessness, has been immersed in water or flooded by water immediately unplug the appliance from the wall socket and prior to further use contact a qualified technician for examination.
- Failure to observe instructions enclosed in this manual may result in the hazard of injury or death.
- Do not let unauthorized opening of the housing of the appliance.
- Do not insert any foreign objects into the housing of the appliance.
- Do not touch the plug and the power cord with damp hands.
- Regularly check the condition of the plug and the cord. If the power cord or the plug is damaged they should be replaced by the Authorized Technical Service personnel.
- In case the appliance is dropped or damaged in any other way before turning it on always contact the Authorized Technical Service for examination and repair.
- Any repairs and work on the appliance should be carried out solely by Authorized Technical Service, never by the end user as unauthorized tampering could prove highly dangerous for the user.
- Do not let the cord hang over or touch hot surfaces or sharp edges. Keep the cord away from naked fire. When disconnecting the appliance from the wall socket, pull on the plug, never on the cord.
- Do not let the cord (or extension cord) be inadvertently pulled on or tripped over.
- Check the operation of the appliance during usage.
- This appliance can be used by children in the age of eight and more or by persons with reduced physical, sensory or mental capabilities or lack of knowledge and experience in operating of the appliance, if they have been given supervision or instruction concerning use of the appliance in a safe way by a person responsible for their safety and they understand the hazards involved. Children should not play with the appliance. Children should not perform cleaning or maintenance of the appliance without supervision.
- Always switch off the appliance and unplug the power cord from the wall socket when the appliance is not in use and prior to cleaning operations. The disconnected plug should be sited in a visible place.
- Warning: The appliance’s power will remain ON unless unplugged.
- Turn off the appliance before pulling the plug out of the wall socket.
- Never pull the appliance on the cord.
- It is prohibited to store any explosive substances such as aerosol / flammable gas cans in the appliance.
- WARNING: Do not block or cover any ventilation openings in the equipment casing or in the built-in structure.
- WARNING: Do not use mechanical or any other means to accelerate the defrosting process other than recommended by the manufacturer.
- WARNING : Protect the refrigeration system from damage.
- WARNING: Do not use any type of electrical equipment other than recommended by the manufacturer inside the food storage chamber.
DESCRIPTION AND INTENDED USE OF THE APPLIANCE
- the cooling cabinet is intended for short-term storage of pre-chilled food products.
- the freezing cabinet are intended for storage of pre-frozen food products
- the housing of the appliance is made of stainless steel
- forced air circulation
- digital controller with temperature display
- automatic defrosting
Product TECHNICAL SPECIFICATION
Model | 880700V02 | 880701V02 | 881400V02 | 881401V02 |
---|---|---|---|---|
Voltage (V/Hz) | 230 / 50 | |||
Power (W) | 353 | 510 | 450 | 710 |
Temperature range (oC) | -2 / +8 | -10 / -20 | -2 / +8 | -10 / -20 |
Dimensions (WxDxH) (mm) | 680x810x2000 | 680x810x2000 | 1340x845x2000 |
1340x845x2000
**Climate class *| 4| 4| 4| 4
Weight** (kg)| 135| 135| 180| 180
- 4 – to + 30 °C / relative humidity 55 %
- 5 – to + 40 °C / relative humidity 40 %
The device contains R290 or R600a coolant – natural, ecological, flammable
gas.
Take special care when transporting and installing the device to avoid
damaging the cooling circuit.
If a leak is revealed, refrain from using devices/items that could cause
sparks or fire and ventilate the room. To avoid the formation of a flammable
gas mixture in the event of a leak from the refrigeration system, install the
device in a room with area of 1m3 per every 8 g of the coolant. The amount of
coolant is given in „TECHNICAL DATA / PRODUCT CARD” and on the nameplate.
PRODUCT CARD
Model | 880700v02 | 880701v02 | 881400v02 | 881401v02 |
---|---|---|---|---|
Intended use | storage | storage | storage | storage |
Operating temperature | cooling | freezing | cooling | freezing |
Category | vertical | vertical | vertical | vertical |
Refrigerants: | R600a, GWP=3 | R290, GWP=3 | R290, GWP=3 |
R290, GWP=3
Parameter| Value
Annual energy consumption AEC (kWh)| 434| 2054| 675| 3165
Coefficient of energetic efficiency EEI| 35.41| 61.78| 36.02| 60.1
Net capacity V N (L)| 376| 376| 770| 770
(where applicable)
Refrigeration capacity V NRef (L)| 376| 0| 770| 0
Freezing capacity V NFrz (L)| 0| 376| 0| 770
Amount of refrigerant (kg)| 0.085| 0.1| 0.11| 0.15
TRANSPORT AND STORAGE
The appliance is protected with a protective film, placed on a wooden pallet, packed in a cardboard box and secured with stripes.
- packaged appliance should be stored in a covered warehouse at an ambient temperature of 0 °C / + 55 °C and humidity of 30 – 95 %;
- it is forbidden to stack appliances;
- read the data on the appliance rating plate. In case of damage or loss of the rating plate it should be replaced immediately;
- do not unscrew the safety guards;
- after unpacking the appliance, carefully remove the protective film and other elements protecting the appliance during transport;
- while lifting the appliance with a lift, position the lift on the outside of the frame;
- transport the appliance and store it exclusively in a vertical position. Never place the appliance on its side or upside down, because it can damage the cooling system (not subject to warranty repair);
- after transporting or moving the appliance wait 2 hours before starting it;
- do not place the appliance in the vicinity of flammable products, outdoors or in a place subject to direct sunlight exposure.
Product INSTALLATION
POSITIONING OF THE APPLIANCE
The appliance should be placed in a dry, adequately ventilated room. In order
to ensure proper work do not place the appliance near a heat source and do not
expose it to direct sunlight. The optimal temperature range in the room in
which the appliance operates is between: + 16 °C and + 35 °C.
If you install the appliance in a room with high humidity level, you may need
to buy an additional tray for condensed water. Avoid placing the appliance in
rooms with a high chlorine and acids content in the air (e.g. at a pool), as
this may cause corrosion of the surface made of stainless steel.
The cooling cabinet is prepared to be positioned at a wall as a free-standing
appliance.
ELECTRICAL CONNECTION
The appliance should be connected to an AC power source.
Before connecting the appliance to the mains, make sure that the voltage and
frequency values given on the rating plate of the appliance correspond with
the voltage and frequency values at the place of installation.
The electrical outlet should be properly earthed and equipped with a
differential current protection device in accordance with legal provisions in
force.
CONTROL PANEL OPTION 1
Description:
Indicator light | Symbol | Status | Meaning |
---|---|---|---|
Settings indicator light | SET | The light is on | Parameter setting |
The light is off | Measurement and control | ||
The light flashes | Checking parameters, entering a |
password
Refrigeration indicator light| **| The light is on| Refrigeration
The light is off| Refrigeration stopped
The light flashes| Refrigeration delay enabled
Defrosting indicator light| **| The light is on| Defrosting
The light is off| Defrosting stopped
DESCRIPTION OF PARAMETERS
Code | Function | Setting range | Default value | Unit |
---|
F01
| Menu password| 00: butt 00-99 functions lock deleting| 55| NO
F02| Setting temperature value| -40 ~+50| 2| °C
F03| Setting temperature difference| 1 – 15| 4| °C
F04| Compressor activation time
delay
| 1 – 15| 3| min.
F05| Interior temperature calibration| -5 ~ +5| 0| °C
F06| Maximum defrosting time| 1 – 60| 20| min.
F07| Defrosting cycle| 1 – 30 units| 12| 1 unit = 30 min.
F08| Defrosting termination temperature| -20 ~+30| 7| °C
F09| Evaporator sensor activation or no activation| 00: not active
01: active
| 1| NO
BUTTONS FUNCTIONS
Buttons | Function |
---|---|
SET | Press to enter the password; Setting parameters mode; Changing between |
the menu and the parameter mode.
| Press to check the value of the set temperature; Selection of the menu
functions; Changing the setting of parameters and a password.
| Press to check the value of the evaporator sensor; Selection of the menu
functions; Changing the setting of parameters and a password.
| Exit from the parameter setting mode; Manual activation or stopping of
defrosting.
Temperature measurement and control mode
- Press the „SET” button and hold it for 3 seconds.
In case the keypad password has been set to „0”, the settings indicator light is on, the display shows „F1” code from the menu, there is no password confirmation and you should directly enter the menu mode to set the parameter.
If the keypad password has not been set to „0”, the indicator light flashes and the display shows „00”, press the „ ” and „ ”, buttons to enter the password, then press the „SET” button to confirm the password. If the password is correct, the system will go to the settings menu. If the password is not correct the settings indicator light will go off and the system will return to the normal temperature measurement and control mode.
Checking parameter settings:
Push the button „ ”. The settings indicator light „SET” starts to flash and
the display shows the set temperature value.
Push the button ”. The settings indicator light „SET” starts to flash and the
display shows the temperature value of the evaporator sensor.
After entering the settings menu, press the „ ”button and the „ ”, button to
select the desired menu function (from F01 to F09).
After selecting the desired menu function, press the „SET” button to set the parameter value, press the „ ” and „ ” „ and select the desired value of the parameter, then press the” SET „button again to return to the function selection from the menu.
In the settings selection mode, press the „ ” button or do not press any
buttons for 30 seconds, the system will save the set parameters values and
exit the parameters setting mode.
Press the „ ” button and hold it for 3 seconds to manually activate or
terminate defrosting.
COMPRESSOR OPERATION AND DEFROST FUNCTION CONTROL
-
Compressor
The compressor will be activated when the time of its activation delay expires if the temperature sensor indicates that the temperature is higher than „set temperature value + temperature difference value „.
The compressor will stop working when the temperature sensor detects that the temperature is lower than the set tem-perature value. -
Defrosting:
The system will start defrosting in accordance with the defrosting cycle set or when manual defrosting is activated.
If the evaporator sensor has been activated and the temperature detected by the evaporator sensor is higher than the temperature of the defrosting termination, it is not possible to activate the defrosting function manually.
Defrosting will be terminated when the temperature detected by the evaporator sensor reaches the value equal to the set value of the defrosting termination temperature or when the set defrosting time has elapsed or when the defrosting has been turned off manually.
If the evaporator sensor has not been activated or if an error occurs, defrosting will be interrupted when the set defrosting time elapses or the defrosting is turned off manually.
ERROR MESSAGES
Message | Cause | Solution |
---|---|---|
E1 | Chamber sensor error | Contact the Technical Service to replace the |
chamber sensor. After the fault has been repa- ired the system will again
calculate the compressor activation delay time.
E2| Evaporator sensor error
The temperature of defrosting termination is incorrect
| Contact the Technical Service to replace the evaporator sensor.
CONTROL PANEL OPTION 2
Button | Function |
---|
| Used to display the setting, in the programming cycle is used to select the
parameter or confirm the operation.
| With this arrow you can display the last alarm, in the programming cycle,
you can scroll through the parameters or increase the displayed value.
**| The arrow turned down is used to display the last alarm, during the
programming cycle, to scroll through the parameters, or to decrease the
displayed setting.
| This button is used to manually start the defrosting process.
Combinations of buttons
**| Used to lock and unlock the keyboard.
| Used to enter the programming mode.
| Return to display the temperature in the chamber.
DESCRIPTION OF INDICATOR LIGHTS
| On| The compressor is on.
---|---|---
| Flashes| The programming mode has been activated.
| On| The defrosting has been activated.
| Flashes| Programming mode, dripping in progress.
o F
o C
| On| Fahrenheit degrees Celsius degrees
HOW TO CHECK THE DURATION OF THE ALARM AND THE MINIMUM AND MAXIMUM TEMPERATURE
If an alarm symbol appears on the display, to see the type of alarm, min (max) temperature, the duration of the alarm,proceed as follows
-
Press the arrow up or arrow down button
-
The display will show the following message „HAL” for high-temperature alarm, „LAL” for low-temperature alarm.
Then „tIM” (time) displays the duration of the alarm in minutes -
The next step is to return to the temperature display
DELETING CONSTANTLY OCCURRING SAVED ALARM
- Press down the SET button and hold it for more than 3 seconds, in the meantime the saved alarm is displayed (the display will show the rSt message);
- To confirm the operation, „rSt” message will start flashing and the normal temperature will be displayed
HOW TO CHECK THE SETTINGS
Press the „SET” button and immediately release it, the display will show the
settings. After pressing and releasing the„SET” button or hold it down for 5
seconds to display the values of the sensor again.
HOW TO CHANGE THE SETTINGS
- Press the „SET” button and hold it down for more than 2 seconds to change the values;
- The value of the settings will be displayed and the LED indicator light will start flashing
- To change the settings, press or and hold it down for 10 seconds
- To save the new settings, press the „SET” button and hold it down for 10 seconds.
STARTING MANUAL DEFROSTING
To start manual defrosting process, press the „SET” button and hold it down
for 2 seconds, that will activate the defrost process.
CHANGING OF PARAMETERS VALUE
To change the parameters values, proceed as follows:
- Enter the programming mode by pressing the SET button and the arrow down button and holding them down for 3 seconds and the „SET” button will start flashing;
- Select the parameter
- Press he „SET” button to display the values
- Use the up or down arrows to change the settings;
- Press the „SET” button to save the new parameters;
- To exit, press the SET + arrow up buttons or wait for 15 seconds without pressing any buttons.
LOCKING OF THE KEYBOARD
- Press the buttons arrow up and arrow down and hold them down for 3 seconds.
- The POF message will appear on the display and the keyboard will be locked. Only information about maximum and minimum temperature can be displayed in this mode.
- If any button is pressed and held down for 3 seconds POF message will be displayed.
UNLOCKING OF THE KEYBOARD
Press the up and down arrow buttons and hold them down for 3 seconds until you
see the „Pon”. message.
CONTINUOUS MODE
If the defrosting process is not enabled, the continuous mode can be activated
by pressing and holding down the arrow up button for 3 seconds. The compressor
will start operating in continuous mode until the Cct parameter setting is
reached.
This process can be terminated before it ends by using the arrow up button and
holding it down for 3 seconds.
ALARMS
Message | Cause |
---|---|
P1 | Chamber sensor error |
P2 | Evaporator sensor error |
HA | Maximum temperature reached |
LA | Minimum temperature alarm |
CONTROL PANEL OPTION 3
**| Display of the setpoint, in the programming mode, parameter selection
and confirmation of changes
---|---
| Start manual defrost
| In programming mode, scrolling through the parameter list or increasing
the value.
**| In programming mode, scrolling through the parameter list or decreasing
the value.
Button combinations
+| Display of the setpoint, in the programming mode, parameter selection
and confirmation of changes
+| Start manual defrost
+| In programming mode, scrolling through the parameter list or
increasing the value.
DESCRIPTION OF INDICATOR LIGHTS
Symbol | Mode | Meaning |
---|---|---|
ON | Defrost active | |
FLASHING | Dripping active | |
ON | Compressor active | |
FLASHING | Activation of short cycle protection (AC parameter) | |
ON | Activation of the fan output | |
FLASHING | Delayed fan activation after defrost | |
ON | Units of measure | |
FLASHING | Programming mode | |
ON | Units of measure | |
FLASHING | Programming mode |
HOW TO DISPLAY THE SETPOINT VALUE
- Press the SET button briefly, the setpoint appears on the screen.
- Press the SET button briefly or wait 5 seconds to return to the standard
HOW TO CHANGE THE SETPOINT
- Hold down the SET button for 2 seconds to change the setpoint value;
- The value of the setpoint appears on the screen, the „C” or „F” LED
- To change the value, use the buttons **or .**
- To confirm the changes, press the SET button or wait 10s
HOW TO RUN A MANUAL DEFROST
Press the for at least 2 sec – manual defrosting will start
HOW TO CHANGE THE PARAMETER VALUE
To change the parameter value:
- Go to programming by simultaneously pressing the buttons SET+ ****for 3 sec (“°C” or “°F” LED flashes).
- Select the desired parameter. Press “SET” to display its value
- Change the value with the and/or .
- Press “SET” to confirm the entered value and move on to the next parameter.
To finish: simultaneously press SET+ or wait 15 seconds without pressing buttons.
Note: The value is stored even in case of exit after 15 seconds idle.
LOCKING THE KEYBOARD
- Press and hold for at least 3 seconds the buttons and.
- An „OFF” message will appear indicating that the keypad is locked. Pressing a button for more than 3 seconds will cause the OFF message to appear.
UNLOCKING THE KEYBOARD
Press the buttons and hold for at least 3 seconds the buttons and ,the „on” message will.
ALARM
Alarm | Cause | Outputs |
---|---|---|
„P1” | Room sensor error | Compressor output depending on „Cy” and „Cn” |
„P2” | Evaporator sensor error | Defrosting completed by timeout |
„HA” | Maximum temp. alarm | Outputs without modifications |
--- | --- | --- |
„LA” | Minimum temp. alarm | Outputs without modifications |
“EA” | External alarm | Outputs without modifications |
“CA” | Serious external alarm | Disable all outputs |
“dA” | Opening the door | Restarting the compressor and fan |
CAUTION! In the event of the errors mentioned above, contact the service immediately and provide the alarm symbol.
CLEANING AND MAINTENANCE
Note: Before starting any maintenance procedure, always disconnect the
appliance from the power supply.
The appliance should be washed with water and dishwashing liquid. It is not
recommended to clean the appliance with detergents, because they can damage
the walls of the cabinet. Plastic parts of the appliance can be washed with
water at the maximum temperature of 85 °C.
During daily cleaning of the appliance, remember to thoroughly clean the
gasket from crumbs and sticky substances,because they can damage it.
The ventilation grate of the compressor (located on the back of the appliance)
should be cleaned regularly, as dirt and dust may block free air circulation.
PROCEDURE IN THE EVENT OF POWER FAILURE
In case the appliance is disconnected from the power supply (both due to a
failure or due to accidental removing of the plug from the electric socket),
the element controlling the work of the compressor will cause that the
restarted appliance will operate according to the current temperature control
knob setting.
DISPOSAL OF THE OLD APPLIANCE
Information for users on the rules concerning proper disposal of electrical
and electronic equipment at the end of its life.
- Leave your old equipment in the shop where you purchase a new appliance. Each store is obliged to accept old equipment free of charge if you buy there the new equipment of the same type and in the same quantity. The only condition is to deliver the old equipment to the store at your expense.
- Dispose of your old equipment at a collection point. Information about the location of the nearest collection point can be found on the local website or the notice board of the municipal office.
- Leave the equipment at a service point. If the repair of the equipment is unprofitable or impossible for technical reasons, the service is obliged to accept this appliance free of charge.
- Return the used equipment at the end of its life without leaving your home. If you do not have the time or ability to deliver your equipment to the collection point, you can use the services of specialized companies.
- Remember! Do not dispose of used equipment together with regular waste.
An illegal or incorrect disposal of the product will lead to high penalties being imposed.
The symbol of a crossed-out rubbish bin on the product, its packaging or its instruction manual means that at the end of its life the product must not be disposed of with regular waste. The user is obliged to deliver their used equipment to a designated collection point for proper processing.
GUARANTEE
The dealer of the appliance is liable under the guarantee.
The guarantee does not cover any damage resulting from the build-up of
limescale inside the appliance. The guarantee also does not cover: damage
caused by external forces such as atmospheric discharge, voltage change,
incorrect setting of electrical voltage, power supply from unsuitable power
outlet, any mechanical, thermal, chemical damage and defects resulting from
them.
Furthermore, the guarantee does not cover the replacement of exhaustible
parts, namely: light bulbs, rubber elements,heating elements damaged by
limescale, glass and other elements that are exposed to any form of wear or
usage, for example; burners, rubber units as well as any breakdowns or
mechanical damage of the appliance elements caused by incorrect storage,
transport, maintenance, installation or operation.
Stalgast Sp. z o.o.
Plac Konesera 9, Budynek O, 03-736 Warszawa
tel.: 22 517 15 75 fax: 22 517 15 77
www.stalgast.com
email: stalgast@stalgast.com
Tel.: +48 22 509 30 77
export@stalgast.com
www.stalgast.eu