ikan LBX8 Lyra Low Profile Soft Panel LED Light User Guide

June 10, 2024
ikan

ikan LBX8 Lyra Low Profile Soft Panel LED Light

ikan-LBX8-Lyra-Low-Profile-Soft-Panel-LED-Light-
PRODUCT

Product Information Lyra Low Profile Soft Panel Light w DMX

The Lyra Low Profile Soft Panel Light w/ DMX is a reliable and sophisticated LED light fixture designed to provide high-quality lighting for indoor use. It comes with a power supply, yoke mount, power cord, and an easy-to-navigate system menu to control the DMX512 channel selection. The fixture has been thoroughly tested and must be grounded properly by qualified personnel for smooth operation.

Features

  • DMX512 channel selection
  • Local control from 10% to 100% brightness
  • Grounding for proper operation
  • Easy-to-navigate system menu
  • Thoroughly tested for reliability

Safety Instructions

  • Use indoor only and avoid exposing it to moisture
  • Do not plug the fixture into a dimmer pack
  • Disconnect from the main power source before servicing or cleaning
  • Handle the power supply by the plug end only
  • Replace the power cord immediately if it becomes frayed or damaged

Usage Instructions

  1. Carefully unpack the Lyra Low Profile Soft Panel Light w/ DMX and check for any shipping damage.
  2. Read and understand the safety instructions before operating the fixture.
  3. Ensure that the fixture is properly grounded by qualified personnel before use.
  4. Select the appropriate DMX512 channel by using the large yellow knob on the back of the fixture.
  5. Adjust the brightness level from 10% to 100% using the local control or the DMX board.
  6. Do not plug the fixture into a dimmer pack.
  7. Disconnect from the main power source before servicing or cleaning.
  8. Handle the power supply by the plug end only.
  9. Replace the power cord immediately if it becomes frayed or damaged.

Overall, the Lyra Low Profile Soft Panel Light w/ DMX is a reliable and easy- to-use LED light fixture that can provide high-quality lighting for indoor use. Follow the safety instructions and usage instructions carefully to ensure a smooth operation and longevity of the product.

What’s Included

  • 1 x Lyra Light Fixture
  • 1 x Power supply
  • 1 x Yoke Mount
  • 1 x Power Cord

General Information

Thank you for buying the Ikan Lyra DMX LED Lights. This fixture has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance. Every fixture has been throughly tested. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact. In the event damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not discard the shipping carton in the trash. Please recycle whenever possible.

Safety Instructions

This fixture is an extremely sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow the guidelines in this manual. The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual.
This device falls under PROTECTION CLASS 1. It’s essential this device be grounded properly. Only qualified personnel should perform all electrical connections. For proper operation, follow the Installation guidelines described in this manual. Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts (yoke) included with this fixture should be used for installation. Any modifications will void the original manufacturer’s warranty and increase the risk of damage and/or personal injury. Never look directly into the light source of this fixture to prevent risk of injury to your retina, which may induce blindness. Always disconnect from main power source before performing any type of service and/or cleaning procedure. Only handle the power supply by the plug end, never pull out the plug by tugging the wire portion of the cord. Do not operate this fixture if the power cord has become frayed, crimped and/or damaged. If the power cord is damaged, replace it immediately with a new one of similar power rating.

Fixture Overview

ikan-LBX8-Lyra-Low-Profile-Soft-Panel-LED-Light-FIG-1

Fixture Menu

ON-BOARD SYSTEM MENU
The fixture comes with an easy to navigate system menu. The next section will detail the functions of each command in the system menu.

LCD MENU CONTROL KNOB
The control knob allows for local control as well as control from DMX board. The local control gives the user adjustment from 10%-100% in brightness. The user can also adjust the DMX channels 1 thru 512 by pressing down on the large yellow dial.

DMX Channel
The DMX512 channel selection can be made from the back of the fixture using the large yellow knob to dial in the correct DMX number. When a DMX signal is detected on the fixture, all other controls are closed down and only DMX channel control can be selected on the rear of the fixture. Depending on the model, the DMX channel selected will require different channels for use on the DMX board. LBX8 will require two channels, one for brightness and one for color temperature. LWX8 will require one channel for brightness.

Light Channel Brightness Color
LBX8 (Bi-Color) 5 Ch 5 Ch 6
LWX8 (Daylight) 5 Ch 5 N/A

Cleaning & Maintenance

CAUTION! Disconnect power before cleaning or maintenance.

CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output, and an extended life. The frequency of cleaning depends on the environment in which the fixture operates: damp, smoky, or particularly dirty environments can cause greater accumulation of dirt on the fixture. Never use alcohol, solvents, or ammonia- based cleaners

MAINTENANCE
Regular inspections are recommended to insure proper function and extended life. There are no user serviceable parts inside this fixture. Please refer all other service issues to an authorized ikan service technician. Should you need any spare parts, please order genuine parts from your local ikan dealer.

Please refer to the following points during routine inspections:

  • Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall.
  • Check for any deformations on the housing, rigging hardware and rigging points (ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter into the fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person(s). Electric power supplies and cables must not show any damage or fraying. Never remove the ground prong from the power cable.

General Guidelines

NEVER OPEN THIS FIXTURE WHEN IN USE!
Please make sure there are NO FLAMMABLE MATERIALS close to the fixture while operating, to prevent any fire hazard. The fixture must be installed in a location with adequate ventilation, at least 1.5 feet (.5m) from adjacent surfaces. Be sure no air ventilation slots are blocked.

  • DO NOT attempt installation and/or operation without knowledge of how to do so.
  • DO NOT permit operation by persons who are not qualified to operate this type of fixture. Most damages are the result of operations by nonprofessionals. Consistent operational breaks may ensure the fixture will function properly for many years to come.
  • DO NOT shake fixture and avoid using brute force when installing and/or operating the fixture.
  • Always install the fixture with an appropriate safety cable. When installing the fixture in a suspended environment, always use correct mounting hardware that can be inserted into the Baby 1/8 in. or Junior 1-1/8 combo pin adapter.
  • Use the original packaging and materials to transport the fixture in for service.

LBX8 Specifications

Beam Angle 110 Degree
Head Type Bi-Color 3200K-5600K
Lens ½ Stop Soft DIffusion
Cooling System Passive Cooling
Control/Dimming Knob Control or DMX
Build Material Heavy Duty Resin Plastic, Aluminum
Yoke Baby 5/8″ — Junior 1 1/8″ Combo Pin
Fixture Size 24 x 6.8 x 1.75 in.
Fixture Weight 2.8lbs
Power Supply Input: 110-220VAC

Output: 24VDC 2.75A; 66W

Power Consumption| 50W

LBX8 Photometrics

5600K CRI: 97 TLCI: 98
DISTANCE FC LUX
--- --- ---
5ft. / 1.5m 65 695.5
10ft. / 3m 19 204
15ft. / 4.5m 9 101.5
4400K CRI: 96 TLCI: 98
--- --- ---
DISTANCE FC LUX
--- --- ---
5ft. / 1.5m 64 685.8
10ft. / 3m 18 195.5
15ft. / 4.5m 9 97.6
3200K CRI: 96 TLCI: 98
--- --- ---
DISTANCE FC LUX
--- --- ---
5ft. / 1.5m 57 609
10ft. / 3m 17 178.3
15ft. / 4.5m 8 88.4

LWX8 Specifications

Beam Angle 110 Degree
Head Type Daylight 5600K
Lens ½ Stop Soft DIffusion
Cooling System Passive Cooling
Control/Dimming Knob Control or DMX
Build Material Heavy Duty Resin Plastic, Aluminum
Yoke Baby 5/8″ — Junior 1 1/8″ Combo Pin
Fixture Size 24 x 6.8 x 1.75 in.
Fixture Weight 2.8lbs
Power Supply Input: 110-220VAC

Output: 24VDC 2.75A; 66W

Power Consumption| 50W

LWX8 Photometrics

5600K CRI: 97 TLCI: 98
DISTANCE FC LUX
--- --- ---
5ft. / 1.5m 67 721.1
10ft. / 3m 20 215.3
15ft. / 4.5m 10 107.6

Optional Accessories
Some other products that work well with the Lyra Lights available from Ikan include:

Learn More
More dynamic information at official website: www.ikancorp.com

Support
Contact email: [email protected]

CONDITIONS OF WARRANTY SERVICE

  • Free service for one year from the day of purchase if the problem is caused by manufacturing errors.
  • The components and maintenance service fee will be charged if the warranty period is expired.

Free Service will not be Provided in the Following Situations:(Even if the product is still within the warranty period.)

  • Damage caused by abuse or misuse, dismantling, or changes to the product not made by the company.
  • Damage caused by natural disaster, abnormal voltage, and environmental factors, etc.

www.ikancorp.com | 1.713.272.8822 | [email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ikan User Manuals

Related Manuals