Quick Guide
Installation Environment
Indoor and outdoor installation is supported. If installing the device outdoors, please do not place the device under direct sunlight. If installing the device indoors, please keep the device at least 2 meters away from light, and at least 3 meters away from the window and door.
Attention:
Biometric recognition products may not be 100% accurate and applicable to all
scenarios and environments. For higher security purposes or scenarios, please
set up an access authentication combination.
Installation
Step 1:Wall-mounting Box or Flush-mounting Box Installation
Wall-Mounting
1. With 86×86 mm embedded junction box in the wall
| |
---|---|---
Fix the wall-mounting box onto the embedded
box (86) with two M4x30 Screws, mark the
positions of the four holes of the wall mounting
box at the hole center.| Take off the box and drill the four marked holes using
a 5 mm drill bit hand drill before inserting the plastic wall anchors into the
drilled holes.| Place the wall mounting box closely against the wall while
lining up its four holes with their corresponding drilled holes and then fix
the wall mounting box on the wall by tightening the four ST4 x 20 screws to
the plastic wall anchors.
2. Without an embedded junction box in the wall
| |
---|---|---
According to the position of the wire on the wall, put the wall-mounting box
closely onto the wall and mark the four positioning holes, while making sure
that relative positions between the wall-mounting box and the wiring hole are
correct.| Drill the marked holes using a 5 mm drill bit hand drill before
inserting plastic wall anchors into the drilled holes.| Place the wall-
mounting box closely against the wall while lining up its four holes with
their corresponding drilled holes and then fix the wall-mounting box on the
wall by tightening four ST x
20 screws to the plastic wall anchors.
Note: It is suggested that you move the bottom edge of the square hole 10 mm away from the wring hole on the wall as highlighted in green in the drawing.
Flush-Mounting
| |
|
---|---|---|---
Cut out a square hole with the dimension (heightwidthdepth = 33712343
mm).| Insert the flush-mounting box into the hole and mark the positions of the
four holes of the flush-mounting box on the wall,
then take off the box and drill the holes on the marked positions using 5 mm
drill bit hand drill
before inserting the plastic
anchors in to the drilled holes.| Break off the round knock-out wiring holes
and lead the wires through the corresponding hole into the flush-mounting box,
then press the flush-mounting box into the square hole. The upper and lower
folded edges of the
flush-mounting box must fit snugly against the wall. Then fix the box
using the four plastic wall anchors and the four ST4x20 screws.| Make sure
that the flush-mounting box are well tightened and its upper and lower folded
edges are fit snugly against the wall, fill in the gap between the wall and the
flush-mounting box using cement or non-corrosive structural adhesive and wait
until the cement is hardened before proceeding to the next step.
STEP 2: Back cover Installation
| | |
---|---|---|---
Hang the one end of the rope on
to the square hanger on the wall-mounting/flush-mounting box then hang the
other end of the rope onto the square hook on the device for the
the convenience of the later wire installation etc.| Connect the wires to the
terminal blocks as needed (for details, refer to “Device Wiring”), then insert
the terminal blocks into the corresponding interface of the mainboard as
indicated in the drawing according to the number of pins.
Note: The pry bar attached can be used to unplug the terminal blocks if
needed.| hoose a suitable size rubber plug (small, large and medium) to hold
down the wires, while tearing off the
adhesive sticker on the selected rubber plug and stick it onto the X915 back
cover and then tear off the
adhesive sticker on the other rubber plug of the same size and stick it on
to the back cover in the position as indicated in the drawing.| Press the X915
back cover silicone rubber sealing ring in to the corresponding groove
as indicated by the arrow and then tighten the back cover using the six M3x4
screws to
its corresponding holes.
STEP 3:Device Mounting
|
| |
---|---|---|---
Take off the rope and hang the device onto the two square hangers on the wall-
mounting/ flush-mounting box. Stick the plate removal key into the small hole
on the upper left corner of the card reader, touch the plate to pull out the
plate.| Drive the two Torx screws into their corresponding holes.| Press the
card reader touch plate into the card reader opening.| Installation is
completed.
Device Wiring.
Warning
When you connect a device containing a coil, such as a relay or an
electromagnetic lock, it is necessary to protect the intercom against voltage
peak while switching off the induction load. For this way of protection, we
recommend a diode 1 A / 200 V (included in the accessories) connected
antiparallel to the device.
Application Network Topology
Configuration
- IP address Checking: Press 9999 on the dial screen, then press 3888 to enter the system screen and click Info to check the device IP address. X915 uses DHCP by default.
- Account Registration: On the web interface, go to the path Account -> Basic page to register and fill in the account information. (please refer to the user manual for more information)
Operation
Make a call:
Enter the IP or SIP number and press the Dial tab to make a call.
Receive a call:
X915 supports Auto Answer by default. Incoming calls from the indoor devices
will be answered automatically.
Unlock by PIN:
Enter the PIN-code on the home screen for door access.
Unlock by RF Card:
Place the configured RF card on the RF card reader area for door access.
Unpacking
Before you be using the device, please check the version you obtained and
ensure that the following items are included in the shipped box:
Mainframe Accessories :
| X915 x 1| | Rubber Plug(Small)x2
---|---|---|---
| Rubber Plug(Large)x2| | Silicon Rubber Sealing Ring x 1
| Torx Wrench x 1| | Card Reader Touch Plate x 1
| 2 x 6 PIN Terminal Blockx 1| | 2 x 5 PIN Terminal Blockx 1
| Rubber Plug(Medium)x2| | Back Cover x 1
| M3x4 Screw x 6| | Torx Screw x 2
| Plate Removal Key x 1| | Rope x 1
| 2 PIN Terminal Block x 1| | Pry barx 1
| Diode x 3| |
Flush-mounting Accessories (Please find in In-Wall Installation Kit box):
| Flush-mounting box x 1
---|---
| ST4 x 20 screw x 4
| Plastic Wall Anchor x 4
Wall-mounting Accessories (Please find in On-Wall Installation Kit box):
| Wall-mounting box x 1
---|---
| M4 x 30 Screw x 2
| ST4 x 20 screw x 4
| Plastic Wall Anchor x 4
Product Overview
http://www.akuvox.com/ Notice Information
Information contained in this document is believed to be accurate and
reliable at the time of printing. This document is subject to change without
notice, any update
to this document can be viewed on Akuvox’ s website: http://www.akuvox.com ©
Copyright 2020 Akuvox Ltd. All rights reserved.
AKUVOX (XIAMEN) NETWORKS CO., LTD.
ADD: 10/F, NO.56 GUANRI ROAD, SOFTWARE PARK II, XIAMEN 361009, CHINA
www.akuvox.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>