nVent RAYCHEM RayStat-M2 Thermostat Instruction Manual
- June 10, 2024
- nVent RAYCHEM
Table of Contents
RAYCHEM
RayStat-M2
nVent RAYCHEM RayStat-M2 is an electronic controller for economical ice and snow melting on outdoor areas and in gutters. Ice forms due to a combination of low temperature and moisture. RayStat-M2 detects temperature and moisture and the snow melting system will usually only be activated if snow or ice is present. RayStat-M2 is suitable for controlling electric heating cables.
Product program
RayStat-M2 | Controller. |
---|---|
RayStat-M2-G-Sensor | Ground sensor for detecting temperaturand moisture. |
RayStat-M2-R-Sensor | Gutter sensor for detecting moisture. |
RayStat-M2-A-Sensor | Ambient Temperature sensor. |
CE and UKCA marking
This product is manufactured in accordance with EU Council Directive
89/336/EEC on electromagnetic compatibility (and subsequent amendments) and EU
Council Directive 2006/95/EEC on electrical equipment designed for use within
certain voltage limits.
Applied standards
EN 61000-6-3, EN 61000-6-2, EN 60730-1 and EN 60730-2-9.
The product may only be used if the complete installation complies with
current directives.
The product carries a manufacturer’s warranty if installed in accordance with
these instructions and current regulations.
If the product has been damaged in any way, e.g. during transport, it must be
inspected and checked by authorised personnel before being connected to the
power supply.
WARNING – Important safety instructions.
Always disconnect the power supply before performing installation or
maintenance work on this control unit or any of the components connected to
it. This control unit and the components connected to it should only be
installed by qualified electricians. Electrical installation must be performed
in accordance with applicable local regulations.
Technical data
Controller RayStat-M2:
Supply voltage ……………………………………230 V AC ±10 %, 50-60 Hz
Output relay (NO) ……………………………………………………………… 16 A
On/off differential …………………………………………………………….0.4°C
Temperature Setting for Startup ……………………………………0/+10°C
Run-on time ………………………………………………………………. 0-5 hours
Ambient temperature ………………………………………………. –10/+50°C
Ambient air humidity ……………………………………………………..10-95 %
Enclosure rating …………………………………………………IP 20 / Nema 1
Power consumption ………………………………………………………….. 3 VA
Weight ………………………………………………………………………….. 200 g
Dimensions H/W/D …………………………………………….. 86/52/59 mm
Ground sensor type RayStat-M2-G-Sensor:
Designed to be embedded in outdoor areas.
Detection …………………………………………. Moisture and temperature
Mounting ……………………………………………………………..Outdoor area
Enclosure rating ………………………………………………………………. IP 68
Ambient temperature ………………………………………………. –50/+70°C
Dimensions ………………………………………………………….H32, Ø60 mm
Roof sensor type RayStat-M2-R-Sensor:
Designed to be mounted in gutter or downpipe. Is used together with outdoor
sensor RayStat-M2-A-sensor.
Detection …………………………………………………………………… Moisture
Mounting ………………………………………………………………………. Gutter
Enclosure rating ………………………………………………………………. IP 68
Ambient temperature ………………………………………………. –50/+70°C
Dimensions H/W/D …………………………………………………..105/30/13 mm
Outdoor temperature sensor type RayStat-M2-A-Sensor:
Detection …………………………………………………………….. Temperature
Mounting …………………………………………………………………………..Wall
Ambient temperature ………………………………………………. –50/+70°C
Dimensions H/W/D …………………………………………….. 86/45/35 mm
NOTE: The snow and ice melting system is deactivated in the event of sensor failure – regardless of sensor type.
Sensor installation
Ground sensor, fig. 1 & 3:
For installation in traced outdoor surfaces where ice and snow are a regular
problem. The sensor must be embedded horizontally with its top flush with the
surrounding surface.
The sensor cable must be installed in accordance with current regulations.
NOTE: We strongly recommend the use of cable pipes in order to protect
the sensor cable. Detailed installation instructions are supplied with the
sensor.
With RayStat-M2-G-Sensor, use the accompanying installation plate.
Roof sensor RayStat-M2-R-Sensor, fig. 2 & 4:
For installation in a gutter or downpipe on the sunny side of the building. It
is important to ensure that the sensor contact elements face against the flow
of melt water. Be aware that the pink (2) and grey (1) wire must not be
installed. Detailed installation instructions are supplied with the sensor.
Outdoor temperature sensor RayStat-M2-A-Sensor, fig. 2 & 4:
For use in conjunction with roof sensor RayStat-M2-R-Sensor. Can also be used
separately for the detection of temperature alone. The sensor should be
mounted on the wall under the eaves on the north side of the building.
Sensor cables
RayStat-M2-G-Sensor and RayStat-M2-R-Sensor are supplied with 10 m cable,
which can be extended up to approx. 200 m using standard installation cable:
6×1.5 mm² for RayStat-M2-G-Sensor and 4×1.5 mm² for RayStat-M2-R-Sensor. The
RayStat-M2-A- Sensor cable can be up to approx. 50 m in length. Sensor cables
must be installed in accordance with current regulations. They must never be
installed parallel to power cables as electrical interference may distort the
sensor signal.
Controller installation
The control unit should be DIN-rail mounted in an approved panel. Connect
supply voltage to terminals 1 and 2. Electrical installation must be performed
in accordance with applicable local regulations.
Setup
RayStat-M2 can be set up for ice and snow melting on outdoor areas in conjunction with RayStat-M2-G-Sensor sensors or in gutters/downpipes in conjunction with RayStat-M2-R-Sensor and RayStat-M2-A-Sensor sensors.
-
Electric heating control with RayStat-M2-G-Sensor (fig. 5 & 7):
Connect 1 RayStat-M2-G-Sensor sensor to terminals 8-14.
Connect heating cable to output relay according to fig. 7. -
Electric heating control with RayStat-M2-R-Sensor + RayStatM2-A-Sensor (fig. 6 & 7): Connect
1 RayStat-M2-R-Sensor sensor to terminals 1014. Note that the pink (2) and grey (1) wires must not be connected. Connect 1 RayStat-M2-A-Sensor sensor to terminals 8 and 9. -
Connect heating cable to output relay according to fig. 7.
How to program the sensitivity:
-
Turn off the power to the RayStat-M2.
-
Connect a wire between terminals 8 and 9
-
Connect a wire between terminals 10 and 11
-
Turn the TIME SET knob to max. (constantly on).
-
Turn the TEMP SET knob to max. (10).
-
Turn on the power. The LED for ON will flash.
a The LEDs for TEMP, MOIST and RELAY will light constantly, indicating the factory setting for sensitivity level. -
Program the sensitivity level by turning the TIME SET knob from 1-5 (1=min., 2=low, 3=normal/factory setting, 4=high, 5=max.).
a The combination of LEDs will indicate the programmed sensitivity (see matrix below). -
Turn off the power and select the required settings for temperature (TEMP SET) and after-run time (TIME SET).
-
Remove the wires connecting terminals 8 and 9 and terminals 10 and 11.
-
Install the temperature sensor and moisture sensor as normal.
Turn the TIME SET knob from 1-5. The combination of LEDs will indicate the programmed sensitivity:
TIME SETknob| Sensitivity level| LED for ”TEMP”| LED for ”MOIST”| LED for
”RELAY”
---|---|---|---|---
1| Minimum| ON| OFF| OFF
2| Low| ON| ON| OFF
3| Factory Setting| ON| ON| ON
4| High| OFF| ON| ON
5| Maximum| OFF| OFF| ON
Wiring
Terminal | Colour code | Wiring |
---|---|---|
1, 2 | Supply voltage, 230 V AC 50/60 Hz | |
5, 7 | Output relay, 16 A (fig.7) | |
8, 9 | grey/pink (1/2) | Temperature sensor 1, RayStat-M2-G-Sensor |
or RayStat-M2-A-Sensor
10, 11| yellow/white (5/6)| Moisture sensor, RayStat-M2-G-Sensor
or RayStat-M2-R-Sensor
13, 14| brown/green (3/4)| Sensor heating RayStat-M2-G-Sensor
or RayStat-M2-R-Sensor
Note that the pink (2) and grey (1) wires are not used with a
RayStat-M2-R-Sensor sensor.
Environment protection and recycling
Help protect the environment by disposing of the packaging and redundant
products in a responsible manner.
Product disposal
Products marked with this symbol must not be disposed of along with household
waste but must be delivered to a waste collection centre in accordance with
current local regulations.
Figures
At the end of this manual there are figures representing the installation and
there is a troubleshooting guide.
TROUBLESHOOTING
RAYSTAT-M2-G-Sensor
NTC 12 kΩ @ 25°C – RAYSTAT-M2-G-Sensor / RAYSTAT-M2-A-Sensor
–20ºC = 112246Ω| 11ºC = 22300Ω| 16ºC = 17750Ω| 21ºC = 14238Ω| 26ºC =
11506Ω| 35ºC = 7978Ω
---|---|---|---|---|---
–10ºC = 63929Ω| 12ºC = 21292Ω| 17ºC = 16974Ω| 22ºC = 13636Ω| 27ºC = 11035Ω|
40ºC = 6569Ω
0ºC = 37942Ω| 13ºC = 20335Ω| 18ºC = 16237Ω| 23ºC = 13064Ω| 28ºC = 10587Ω|
45ºC = 5442Ω
5ºC = 29645Ω| 14ºC = 19428Ω| 19ºC = 15537Ω| 24ºC = 12519Ω| 29ºC = 10159Ω|
50ºC = 4535Ω
10ºC = 23364Ω| 15ºC = 18567Ω| 20ºC = 14871Ω| 25ºC = 12000Ω| 30ºC = 9752Ω|
55ºC = 3800Ω
RAYSTAT-M2-A-Sensor: - > NTC 12 kΩ @ 25°C
Normal operation mode with ambient and gutter sensors – connections
Voltage-free operation using a contactor – connections
- Local regulations, standards and ordinances may prescribe the use of two or four-pole overcurrent or residual current circuit breakers.
**Depending on the application, single and and multi-field contactors can be used.
Danmark
Tel +45 70 11 04 00
salesdk@nVent.com| Deutschland
Tel 0800 1818205
Fax 0800 1818204
salesde@nVent.com| Italia
Tel +39 02 577 61 51
Fax +39 02 577 61 55 28
salesit@nVent.com| Nederland
Tel 0800 0224978
Fax 0800 0224993
salesnl@nVent.com| United Kingdom
Tel 0800 969 013
Fax 0800 968 624
salesthermalUK@nVent.com
---|---|---|---|---
©2023 nVent. All nVent marks and logos are owned or licensed by nVent Services
GmbH or its affiliates. All other trademarks are the property of their
respective owners. nVent reserves the right to change specifications without
notice.
RAYCHEM-IM-H82008-RaystatM2-ML-2303