DEFA MultiCharger 1x12A
The DEFA MultiCharger 1x12A is a modern switch-mode charger that represents the latest technology within battery charging. It is designed to provide batteries with optimum life and is well-suited to battery sizes up to approximately 150Ah. The charger can maintenance charge the battery for an unlimited time and can stand parallel charging up to 6A parallel consumption while charging the batteries. The charging voltage is temperature-compensated with an external sensor.
Technical Information
Article Number | 706700 |
---|---|
Input Voltage (VAC) | 230 |
Temperature range (°C) | -35 to +50 |
Charging Voltage S1 (VDC) | 14.4 |
Maintenance Voltage S2 (VDC) | 13.5 |
Recommended Maximum Battery Size (Ah) | 150 |
Ingress Protection Rating (IP) | 44 |
Weight (kg) | 1 |
Dimensions (mm) | 138x98x53 |
Approvals | EN60335-1, EN60335-2-29, EN55014-1, EN55014-2, EN61003-3/2 |
Item number | 706700 |
--- | --- |
Mains Voltage [VAC] | 230 |
Temperature Range [ºC] | -35 +50 |
Charging Voltage* S1 [VDC] | 14,4 |
Maintenance S2 [VDC] | 13,5 |
Current Max. [A] | 12 |
Battery Size Max. [Ah] | 150 |
IP rating [IP] | 44 |
Weight [kg] | 1 |
Measure (H/W/D) [mm] | 138x98x53 |
Acceptance | EN60335-1, EN60335-2-29, EN55014-1, EN55014-2, EN61003-3/2 |
Available Accessories
Article Number | Name |
---|---|
705294 | 5m Remote LED Panel, 1 channel |
705295 | 10m Remote LED Panel, 1 channel |
705296 | 20m Remote LED Panel, 1 channel |
705463 | Schuko cable for charger |
Charge Process
See picture on page 3 of the user manual for a graph of the charge process, showing voltage (V) and current (I) over time (t). The LED on the front of the charger shows the charger status:
- Green pulse – Charging
- Solid green – Fully charged
- Red pulse – Error
Installation
Read the user manual carefully. Wrong installation can result in damage to the equipment and possible injury. If there are any uncertainties, please contact DEFA or a qualified person. Fix the charger properly where it is to be installed. See drill guide on page 2. Connect red wire to (+) end black wire to (-) The charger is intended for use with lead/acid, AGM and GEL batteries, but the battery manufacturers recommendations should always be taken into consideration. The temperature sensor should be placed on the battery or close to the battery for optimal functionality. The fuse on the charging cable is 15A. The charger has to be installed with the connectors facing downwards to maintain IP rating 44. A starter kill wire (See picture on page 3) or a remote LED panel can be connected to the center connector.
- To ensure correct charging voltages, do not shorten or lengthen the charging cables.
- Route the cables onto the contacts on the battery charger as straight as possible to prevent the PlugIn contacts from being bent or twisted.
NOTE : To make sure the correct charging voltages the charging cables must not we shortened or made longer.
NOTE : Route the cables onto the contacts on the battery charger (Page 2, picture 1) so that they are straight, in order to prevent the PlugIn contacts from being bent or twisted (Page 2, picture 2).
Maintenance
The charger is maintenance-free. All batteries should be inspected monthly as a minimum to achieve the best possible safety. The charging process is such that the batteries remain fully charged without further water consumption than normal evaporation. The charger is maintenance free. All batteries should be inspected monthly as a minimum to achieve the best possible safety. The charging process is in such way that the batteries remain fully charged without further water consumption than normal evaporation.
Warranty
For information on warranty, refer to the DEFA website. The guarantee applies to faults in production and materials for 2 years from date of purchase. The customer must deliver the product back to the place of purchase together with the receipt. The guarantee shall cease to apply if the charger is handled negligently, opened or repaired by someone other than DEFA or an authorized representative of DEFA. DEFA has no other guarantee than this and will not be responsible for other costs than those referred to, i.e. no possible additional costs. Neither is DEFA bound by any other guarantee.
Product Usage Instructions
- Ensure that the charger is installed correctly according to the user manual instructions.
- Connect the charger to the battery to be charged, ensuring that the cables are routed as straight as possible onto the contacts on the charger.
- Turn on the power supply to the charger.
- The charger will automatically start charging the battery. Refer to the user manual for information on the charge process.
- Inspect the battery monthly to ensure it is functioning properly.
Note : For further information on accessories or troubleshooting, refer to the user manual or contact DEFA customer support.
SAFETY
- Please read the manual carefully before use.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Do not attempt to charge no-rechargeable batteries.
- After use, disconnect the mains power before disconnecting from the battery.
- Only use the charger in well-vented area and on vented batteries.
- This charger has to be repaired by professionals.
- The charge output is protected against short circuiting and wrong connections.
- The charger does not draw current from the battery when the main power is not connected.
- Do not install the charger in a highly flammable environment.
- Do not charge a damaged battery.
- During charging, battery gas which is very explosive can be developed. Take care not to have sparks, open flames, cigarettes or similar in the vicinity of the battery.
- The acid in the battery is corrosive and harmful. It damages clothes, metal and varnish. In case of spillage and contact with skin, wash and rinse thoroughly with water and consult a doctor.
- Lead and other chemicals that are used in batteries are toxic. Wash skin and hands thoroughly after working with batteries
Temperature-compensated approx 5,0 mV/oC/cell. Ref. 25 oC. DEFA confirms that these chargers satisfy relevant safety requirements according to prevailing regulations and standards