NOVUS NVIP-8VE-6201 Vandal Proof IP Camera Instruction Manual

June 4, 2024
Novus

NOVUS NVIP-8VE-6201 Vandal Proof IP Camera

**NVIP- 8VE-6201**

IMPORTANT SAFEGUARDS AND WARNINGS

THE PRODUCT MEETS THE REQUIREMENTS CONTAINED IN THE FOLLOWING DIRECTIVES:

| DIRECTIVE 2014/30/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (OJ L 96, 29.3.2014, p. 79–106, with changes)
---|---
| DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic equipment (WEEE) (OJ L 197, 24.7.2012, p. 38–71, with changes)
| DIRECTIVE 2011/65/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (OJ L 174, 1.7.2011, p. 88–110, with changes)

Information

The device, as a part of professional CCTV system used for surveillance and control, is not designed for self installation in households by individuals without technical knowledge.

Excluding of responsibility in case of damaging data on a disk or other devices:

The manufacturer does not bear any responsibility in case of damaging or losing data on a disk or other devices during device operation.

WARNING!
PRIOR TO UNDERTAKING ANY ACTION THAT IS NOT DESCRIBED FOR THE GIVEN PRODUCT IN USER’S MANUAL AND OTHER DOCUMENTS DELIVERED WITH THE PRODUCT, OR IF IT DOES NOT ARISE FROM THE USUAL APPLICATION OF THE PRODUCT, MANUFACTURER MUST BE CONTACTED UNDER THE RIGOR OF EXCLUDING THE MANUFACTURER’S RESPONSIBILITY FOR THE RESULTS OF SUCH AN ACTION.

| Pictures in this publication showing camera views can be simulations. Actual camera images may vary depending on the type, model, settings, observation area, or environmental conditions.
---|---

WARNING!
THE KNOWLEDGE OF THIS MANUAL IS AN INDESPENSIBLE CONDITION OF A PROPER DEVICE OPERATION. YOU ARE KINDLY REQUSTED TO FAMILIRIZE YOURSELF WITH THE MANUAL PRIOR TO INSTALLATION AND FURTHER DEVICE OPERATION.

WARNING!
USER IS NOT ALLOWED TO DISASSEMBLE THE CASING AS THERE ARE NO USER -SERVICEABLE PARTS INSIDE THIS UNIT. ONLY AUTHORIZED SERVICE PERSONNEL MAY OPEN THE UNIT INSTALLATION AND SERVICING SHOULD ONLY BE DONE BY QUALIFIED SERVICE PERSONNEL AND SHOULD CONFORM TO ALL LOCAL REGULATIONS

  1. Prior to undertaking any action please consult the following manual and read all the safety and operating instructions before starting the device.
  2. Please keep this manual for the lifespan of the device in case referring to the contents of this manual is necessary;
  3. All the safety precautions referred to in this manual should be strictly followed, as they have a direct influence on user’s safety and durability and reliability of the device;
  4. All actions conducted by the servicemen and users must be accomplished in accordance with the user’s manual;
  5. The device should be disconnected from power sources during maintenance procedures;
  6. Usage of additional devices and components neither provided nor recommended by the producer is forbidden;
  7. You are not allowed to use the camera in high humidity environment (i.e. close to swimming pools, bath tubs, damp basements);
  8. Mounting the device in places where proper ventilation cannot be provided (e. g. closed lockers etc.) is not recommended since it may lead to heat build-up and damaging the device itself as a consequence;
  9. Mounting the camera on unstable surface or using not recommended mounts is forbidden. Improperly mounted camera may cause a fatal accident or may be seriously damaged itself. The camera must be mounted by qualified personnel with proper authorization, in accordance with this user’s manual.
  10. Device should be supplied only from a power sources whose parameters are in accordance with those specified by the producer in the camera technical datasheet. Therefore, it is forbidden to supply the camera from a power sources with unknown parameters, unstable or not meeting producer’s requirements;

Due to the product being constantly enhanced and optimized, certain parameters and functions described in the manual in question may change without further notice.
We strongly suggest visiting the www.novuscctv.com/en website in order to access the newest full manual

FOREWORD INFORMATION

General Characteristics
  • Sensor resolution: 8 megapixels
  • Mechanical IR cut filter (IR operation capability)
  • Min. Illumination from 0 lx with IR LED on
  • Wide Dynamic Range (WDR) for enhanced image quality in diverse light conditions
  • Digital Noise Reduction (DNR)
  • Defog function (F-DNR)
  • Highlight Compensation (HLC)
  • Back Light Compensation (BLC)
  • Reduction of image flicker (Antiflicker)
  • Lens type: varifocal, f = 2.8mm/F1.6
  • Built-in LED illuminator
  • Built-in webserver: camera configuration through the website
  • Video compression: H.264, H.265, H.264+, H.265+, MJPEG / G711
  • Max. video resolution up to 3840×2160
  • Multi streaming: compression, resolution, speed and quality defined individually for each video stream
  • ROI functions
  • Motion detection
  • Private Zones
  • RTSP protocol support for video transmission
  • Schedule
  • Micro SD card up to 256GB
  • Built-in microphone
  • Wide range of responses to alarm events: e-mail with attachment, saving file on FTP server, saving file on microSD card
  • Electronic Shutter from 1/3 s to 1/10000 s.
  • Supports up to 3 streams
  • ONVIF Protocol Support
  • Software: NMS (NOVUS MANAGEMENT SYSTEM) for video recording, live monitoring, playback and remote IP devices administration
  • Power supply: 12 VDC / PoE
Technical specification

IMAGE

Image Sensor| 8 MPX CMOS sensor 1/2.8” SONY STARVIS
Number of Effective Pixels| 3864 (H) x 2192 (V)
Min. Illumination| 0.06 lx/F1.6 – color mode, 0 lx (IR on) – B/W mode
Electronic Shutter| auto/manual: 1/3 s ~ 1/10000 s
Digital Slow Shutter (DSS)| up to 1/3 s
Wide Dynamic Range (WDR)| yes (double scan sensor), 120dB
Digital Noise Reduction (DNR)| 2D, 3D
Defog Function (F-DNR)| yes
Highlight Compensation (HLC)| yes
Back Light Compensation (BLC)| yes
Reduction of image flicker (Antiflicker)| yes
LENS
Lens Type| fixed focal, f=2.8 mm/F1.6
DAY/NIGHT
Switching Type| mechanical IR cut filter
Switching Mode| auto, manual, time
Switching Level Adjustment| yes
Switching Delay| 2 ~ 120 s
Switching Schedule| yes
Visible Light Sensor| yes
NETWORK
Stream Resolution| 3840 x 2160 (4K Ultra HD), 3072 x 2048, 2592 x 1944, 2560 x 1440 (QHD), 1920 x 1080 (Full HD), 1280 x 720 (HD), 704 x 576, 704 x 480, 480 x 240, 352 x 288 (CIF), 352 x 240
Frame Rate| 20 fps for 3840 x 2160, 3072 x 2048, 30 fps for 2592 x 1944 and lower resolutions
Multistreaming Mode| 3 streams
Video/Audio Compression| H.264, H.264+, H.265, H.265+, MJPEG/G.711
Number of Simultaneous Connections| max. 10
Bandwidth| 40 Mb/s in total
Network Protocols Support| HTTP, IPv4, IPv4/v6, UDP, HTTPS, FTP, DHCP, DDNS, NTP, RTSP, RTP, UPnP, SNMP, QoS, IEEE 802.1X, PPPoE, SMTP, RTCP, ICMP
ONVIF Protocol Support| Profile S/G
Camera Configuration| from Internet Explorer browser languages: Polish, English, Russian, and others
Compatible Software| NMS, N Control 6000
Mobile applications| SuperLive Plus (iPhone, Android)
OTHER FUNCTIONS
Privacy Zones| 4 video mask type: single color
Motion Detection| yes
Region of interest (ROI)| 3
Video Content Analysis (VCA)| tamper, line cross, zone entrance, Scene Change, Video Blurred, Video Color Cast
Image Processing| 180˚image rotation, sharpening, mirror effect, corridor mode, vertical flip, horizontal flip, lens distortion correction
Prealarm/Postalarm| up to 6 s/up to 120 s
System Reaction to Alarm Events| e-mail, e-mail with attachment, saving file on FTP server, saving file on SD card
Restoring default settings| via web browser, using reset button, via NMS IPTool software
IR LED
LED Number| 1
Range| 30 m
Smart IR| yes (software support)
INTERFACES
Audio Input/Output| 1 x Jack (3.5 mm)/- built-in microphone
Network Interface| 1 x Ethernet – RJ-45 interface, 10/100 Mbit/s
Memory Card Slot| microSD – capacity up to 256GB
INSTALLATION PARAMETERS
Dimensions (mm)| 95 (Ф) x 83 (H)
Weight| 0.5 kg
Degree of Protection| IP 67 (details in the user’s manual)
Enclosure| vandalproof IK10 impact rating aluminium, white
Power Supply| PoE, 12 VDC
Surge protection| TVS 4000 V
Power Consumption| 6 W, 10 W (IR on)
Operating Temperature| -30°C ~ 60°C
Humidity| max. 95%, relative (non-condensing)

Camera dimensions (mm)

Camera NVIP-8VE-6201

Package contents

After opening the package make sure that the following elements are inside:

  • IP camera
  • Accessories bag
  • Short version of user’s manual

If any of this elements has been damaged during transport, pack all the elements back into the original box and contact your supplier for further assistance.

CAUTION!
It is forbidden to use – as the camera power source – PoE equipment (adapters, etc.) not compatible with IEEE 802.3af standard (items called “passive PoE power supply”). Damages caused by the usage of improper power supply source are not covered by the warranty.

START-UP AND INITIAL IP CAMERA CONFIGURATION

CAUTION!
If the device was brought from a location with lower temperature, please wait until it reaches the temperature of location it is currently in. Turning the device on immediately after bringing it from a location with lower ambient temperature is forbidden, as the condensing water vapour may cause short- circuits and damage the device as a result.

Before starting the device familiarize yourself with the description and the role of particular inputs, outputs and adjusting elements that the device is equipped with.

Description of connectors and control tools

  1. 100 Mb/s Ethernet port (PoE RJ-45 connector)
  2. Audio input (Jack 3.5 mm)
  3. Power supply 12VDC
  4. Counter nut
  5. Base of camera
  6. Built-in microphone
  7. MicroSD card slot
  8. Reset button
Ethernet cable connecting

To maintain tightness of ethernet cable connection, please follow instruction below:

  1. Unscrew the nut (1) from the connector cover (2).
  2. Route the network cable (without the RJ-45 plug) through the components (1) and (2),  than crimp theRJ-45 connector.
  3. Plug the RJ-45 connector into the hermetic socket (3), screw the connector cover (2), and than the nut (1).

CAUTION!
The declared degree of protection of the camera relates to its housing and does not take into account the possibility of moisture infiltration into the camera by connection cables. Connection cables protection through i.e. sealing up is the camera installer duty. The manufacturer is not liable for any camera damages caused as a result of failing in performing that activity by installer, which also means that camera damaged in that way is not subject to warranty repairs.
CAUTION!
Camera power supply connector is not hermetic. Installer should seal this connector by himself.
Camera can be supplied using external power supply unit corresponding with the camera parameters or by using RJ45 network socket and PoE (802.3af) power supply unit. If you’re using external power supply please connect wires according to polarisation shown on picture:

Scheme of 12VDC power supply connector
NVIP-8VE-6201 Vandal Proof IP Camera Overview

CAUTION!
In order to provide protection against voltage surges/lightning strikes, usage of appropriate surge protectors is advised. Any damages resulting from surges are not eligible for service repairs.

Camera mounting

To mount a camera please follow the instructions below:

  • Unscrew the counter screw (4).
  • Remove the camera cover (3), remove the camera from the base (5).
  • Put the bracket to the wall in a desired mounting place (with cable hole). Take the drill pattern and mark future drilling holes for screws and wires.
  • Drill holes for screws, wires and base.
  • Mount the camera base (5) using the supplied plugs and screws.
  • If necessary, unscrew the camera service panel (1), mount microSD card in the socket (2) and screw the camera service panel (1).
  • Connect the camera wires, put camera on the base (5), attach the cover (3) and pre-tighten the counter screw (4).
  • Adjust camera position.
  • Tighten to the stop counter screw (4).
    NVIP-8VE-6201 Vandal Proof IP Camera Overview

CAUTION!
Please note that the wall or ceiling must have enough strength to carry the IP Camera.
CAUTION!
In order to obtain declared degree of protection please seal the camera bracket to prevent water getting inside. Furthermore, when installing the bracket on rough/uneven surfaces, please additionally seal the junction with appropriate sealing mass. Please pay special attention to any mounting holes and if they are a loop-through ones, seal them too.

Starting the IP camera

To run NOVUS IP camera you have to connect ethernet cable between camera and network PoE switch with PoE support (IEEE 802.3af).
You can also power it from 12VDC power supply compatible with camera power supply specification.
The recommended way to start an IP camera and perform its configuration is a direct connection to the network switch which is not connected to other devices. To obtain further information about network configuration parameters (IP address, gateway, network mask, etc.) please contact your network administrator.

  • Connection using network switch with PoE support
    Starting the IP camera

  • Connection using external power supply and network switch
    Starting the IP camera

  • Connection using external power supply directly to the computer
    Starting the IP camera

Information:
Power supply adapter is not included. Please use power adapter with parameters specified in user ‘s manual.

Initial configuration via the web browser

The default network settings for NVIP-8VE-6201 camera are :

  1. IP address= 192.168.1.200
  2. Network mask – 255.255.255.0
  3. Gateway – 192.168.1.1
  4. User name – root
  5. Password – pass

Knowing the camera’s IP address you need to appropriately set PC IP address, so the two devices can operate in one network subnet ( e.g. for IP 192.168.1.1, appropriate address for the camera ranges from 192.168.1.2 to 192.168.1.254, for example 192.168.1.60). It is not allowed to set the same addresses for camera and PC computer.

You can either set a network configuration (IP address, gateway, net mask, etc.) of NOVUS IP camera yourself or select DHCP mode (DHCP server is required in this method in target network) by using web browser or by NMS software. When you use DHCP server check IP address lease and its linking with camera MAC address to avoid changing or losing IP address during device operation or network/DHCP server breakdown. You have to remember to use a new camera IP address after changing network parameters.

After network setting configuration has been done, the camera can be connected to a target network.

Security recommendations for network architecture and configuration

CAUTION!
Below are shown security recommendations for network architecture and configuration of CCTV systems that are connected to the Internet to reduce the risk of unauthorized interference with the system by a third party.

  1. Absolutely change the default passwords and user names (if the device gives this possibility) of all applied network devices (recorders, cameras, routers, network switches, etc.) to the severely complexity password. Use lowercase and uppercase letters, numbers, and special characters if there is such possibility.

  2. Depending on the available functionality in the order to restrict access to the used network devices at the administrator account level, it is recommended to configure the users accounts accordingly.

  3. Do not use DMZ function (Demilitarized zone) in your router. Using that function you open the access to recorder system from the Internet on all ports, which gives possibility for an unauthorized interference with the system.
    Instead of DMZ use port forwarding redirect only the ports which are necessary for the performance of the connection (detailed information about ports of communication in different models of recorders, cameras, etc. can be found in the operating instructions).

  4. Use routers with firewall function and make sure it is enabled and properly configured.

  5. It is recommended to change the default network communication port numbers of used devices if there is such possibility.

  6. If used network devices has a UPnP feature and it is not used, turn it off.

  7. If used network devices has a P2P feature and it is not used, turn it off.

  8. If used network devices support HTTPS protocol for connection, it is recommended to use it.

  9. If used network devices support IP filtering for authorized connections function, it is recommended to use it.

  10. If used recorder has two network interfaces it is recommended to use both of them to physically separate network for cameras and network for Internet connection. The only device in the system, accessible from Internet will be recorder – there will be no physically access directly to any camera.

NETWORK CONNECTION USING WEB BROSWER

Recommended PC specification for web browser connections

Requirements below apply to connection with an IP camera, assuming smooth image display in 3840×2160 resolution and 20 fps speed.

  1. CPU Intel i7 3 GHz
  2. RAM Memory min. 6 GB
  3. VGA card Nvidia GeForce 1GB
  4. Operating System Windows 10
  5. Network card 100/1000 Mb/s
Connection with IP camera via web browser

CAUTION!
To maintain correct operation as snapshot or video recording you must run the browser as an administrator.

You have to enter camera IP address in the web browser address bar. If IP address is correct user login window will be displayed:
Connection with IP camera via web browser

In the Language box you can change the display language. Available languages: Polish, English and others.
Connection with IP camera via web browser

CAUTION!
Default user is root and default password is pass. The camera will ask you to change the default
password during the first login (recommended). To do this, check the Modify password option and then enter and confirm the new password. In order to log into the camera without changing the password, press the OK button. The message will be displayed each time you log in, until you change your password, or select the Do not show again option.

If you’re first time running the camera, you will see the screen as below.
Connection with IP camera via web browser

To correctly camera working, you need a NetIPCamera plugin. You have to download and install it.
To do it just click Save button, then Run, close IE browser, choose the language, click Install button and at the end click Finish button. After installation run IE browser.

CAUTION!
In Windows Vista/7/8/8.1/10 the ActiveX applet may be blocked by Windows Defender or User account control. In such case you should allow to run this applet, or simply disable these functions.

CAUTION!
If the installation fails, changing security settings for the IE browser is required. In order to do that, please select Enable for Initialize and script ActiveX controls not marked as safe and Download unsigned ActiveX controls option.

WWW INTERFACE – WORKING WITH IP CAMERA

Displaying live video

Displaying live video

  1. Camera menu
    • Live – opens the camera live video
    • Config – opens the camera configuration menu
    • Search – opens the camera playback
    • Logout – button used to log out the current user

  2. The buttons for changing the displayed stream and fluency – allow to change the displayed stream to Main stream, Sub stream and also allow you to choose between Real-time, Balanced and Fluent fluency.

  3. Alarm icons – icons showing the current status of some camera alarms.

  4. Live video window

  5. Image settings buttons – these buttons change the picture display mode in the live video preview:
    Camera-Function-icons

  6. Function buttons – these buttons allow you to enable / disable some of functions:

ELECTRIC CONNECTORS AND ACCESORIES

MicroSD card installation

Camera supports microSD cards up to a maximum size of 256GB. In order to install the card properly, please follow the instructions below:

  • Turn off the camera power.
  • Unscrew the camera service panel (1).
  • Mount microSD card in the socket (2).
  • Screw the camera service panel (1).
  • Turn on the camera.
  • Check the SD card by checking its capacity in the “System” -> “SD Card” tab.

NVIP-8VE-6201 Vandal Proof IP Camera Overview

FACTORY SETTINGS RESTORING

Restoring factory settings of the IP camera restores all default settings. This process takes about two minutes. NOVUS NVIP-8VE-6201 cameras allow to restore defaults via:

  • software (via web browser )
  • software (via NMS IPTool)
  • hardware (using reset button (RST))
Software factory settings restoring via web browser

Restoring factory settings via web browser allows you to optionally keep some settings, such as network settings. To restore default settings go to: “Maintenance -> Backup and Restore” tab.

Software factory settings restoring via NMS IPTool

NMS IPTool (version 3.5 or later) allows to restore factory settings. To restore settings via NMS IPTool, find the camera in the list of available devices and then, on the right side of the row click , .
Then within 30 seconds disconnect power of the camera. After reconnecting the camera, all settings are factory default.
Software factory settings restoring via NMS IPTool

Hardware factory settings restoring

In order to restore factory settings using reset button (RST), please follow the instructions below:

  • Unscrew the camera service panel (1).
  • Press the reset button (2) and hold on for 10 seconds.
  • Release button
  • Screw the camera service panel (1).
  • Log on after 2 minutes using default IP address (http://192.168.1.200) and default user name (root) and password ( pass ).

Hardware factory settings restoring

AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
431 Pulawska St., 02-801 Warsaw, Poland
tel.: +4822 546 0 546, [email protected]
www.novuscctv.com

NOVUS-Logo.png

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Novus User Manuals

Related Manuals