Westfalia 860257 550W Submersible Sump Pump Instruction Manual

June 10, 2024
Westfalia

Submersible Sump Pump 550 W
Article No. 86 02 57
Original Instructions

860257 550W Submersible Sump Pump

Dear Customers
Instruction manuals provide valuable hints for using your new device. They enable you to use all functions, and they help you avoid misunderstandings and prevent damage.
Please take the time to read this manual carefully and keep it for future reference.

Overview

Carrying Handle
Retainer Clamp for Float Switch
Pump Housing
Float Switch
Universal Hose Adaptor
Water Outlet Opening
Suction Base

Using

Intended Use

  • The submersible sump pump has been designed for pumping clear and dirty water. It is not intended for delivering salt water, corrosive, easily flammable or explosive  liquids (e.g. petrol, paraffin, thinners, etc.), faeces, oil, heating oil or foodstuffs. The pump can be used for delivering water, containing floating organical particles such as leaves, paper, plant scraps or firm particles up to a diameter of 35 mm.
  • The submersible sump pump can be used for dry up garages, cellars, basements, swimming pools, tubs, tanks, springs, wells etc. When immersing the pump into a well,  make sure the diameter of the well is not smaller than 40 x 40 x 50 cm so the float switch (4) can float freely.
  • The pump is not designed for commercial continuous operation.
  • The intended use also includes an operation following the operating instructions. Any use beyond these parameters (different media, applying force) or any changes  (reconstruction, no original accessory) can lead to serious risks  and is regarded as use that is contrary to the intended purpose.

Before first Use
Unpack the submersible sump pump and check all parts for any damage in transit. Keep packaging materials out of reach of children.
There is risk of suffocation!
Preparation

  1. Before each use, check the pump and the power cord for any damages. Do not use the pump in case of damages.

  2. Screw the universal hose adaptor (5) on the water outlet opening (6).

  3. Tightly attach or screw on the hose (not included) to be used for pumping off the water to the hose connection (5) of the hose adaptor. If required, use Teflon tape for sealing.

  4. Set the pump on a flat surface into the water supply you want to pump off. Make sure that the pump cannot move during operation.
    Pay attention to the maximum submersion depth (refer to Technical Data). Always make sure that the suction opening is not blocked or obstructed during operation. If  necessary, place the pump on a brick or similar.

  5. When immersing the pump in a very deep pit or well, attach a sufficiently strong rope (water-proof) or chain to the carrying handle in order to guide the pump down.  Never use the power cord for immersing and lifting up the pump.

  6. A retainer clamp (2) is located on the side of the carrying handle. It serves the purpose of fixing the line of the float switch. Fix the float switch so that its leading edge  “solidly” touches the ground.

  7.  Run the vacuum hose. Observe the maximum delivery height (refer to the Technical Data).

Electrical Connection – Operation
Turning the pump on and off is done via the integrated float switch (4).
The pump automatically switches off if the unit is unplugged of if water level falls below a specified height.

  1. Insert the power plug into a protected socket.

  2. Pumping will start automatically as soon as the pump is plugged and the float switch (4) lies horizontally on the water.
    If the water level falls below 3.5 cm the pump will switch off automatically. This will effectively prevent the pump from running dry. If the water level rises again above a  certain level and the power cord is still plugged in, the pump will automatically turn on and start pumping.

  3. Pull the power plug to turn off the pump. Make sure that no particles bigger than approx. 35 mm get sucked as this can block the turbine wheel.

Thermal Switch – Overheat Protection
The pump is equipped with an automatic thermal protection, which prevents damage to the pump caused by overheating. If the pump becomes too hot during operating, it  will automatically switch off. Pull the plug of the pump and allow the pump to cool down for approx.
30 minutes before operating again.

Running Dry
Absolutely avoid dry running of the pump!
Dry running is operating the pump without water in the casing.

Vent Valve
The pump is equipped with a vent valve.
When inserting the pump into water the pump will automatically ventilate.

Manual Operation
For manual operation you have to reposition the float switch at a higher level or to keep the float switch up by hand. By doing this the water can be pumped up completely.  An automatic cutoff does not occur.
Do not operate the pump unsupervised during manual operation.
Disconnect the pump from power mains as soon as the water level falls below 3.5 cm. Otherwise, the pump will run dry long and can be damaged.
Maintenance, Cleaning, Storing and Transport

  • Unplug the power plug before undertaking any kind of maintenance work or before cleaning.
  • The pump does not require maintenance apart from occasionally cleaning the housing and the strainer.
  • When opening covers or removing casing parts you may expose live parts. Capacitors inside the device may still carry voltage even though they have been disconnected  from all voltage sources.
  • In case the pump pumped fluids, which leave residue, it should be thoroughly cleaned after use with clean water. Sand, mud or suspended sediment in the pumped water  can affect its delivery rate.
  • To thoroughly clean the turbine wheel, unscrew the screws and take apart the base from the upper housing. Clean dirt with a brush etc. Rinse the pump with clear water.
  • Never use corrosive or acidic cleaners to clean the pump.
  • Keep the suction base (7) free from dirt and blockages of any kind to prevent clogging.
  • Store the pump in a dry place that is protected from dust, dirt and frost. Make sure the pump is dry before storing it for long time.
  • The pump does not contain any parts serviceable by you. Do not disassemble the pump and do not try to repair it yourself. Repairs must be done by a professional only.
  • Carry the pump only by the carrying handle (1). Never carry, or lift up the pump by the power cord.

Technical Data

Operating Voltage 230 V~ 50 Hz
Rated Power 550 W
Protection Class I
Degree of Protection IPX8
Power Cord Length 10 m
Power Cord Type H07RN8-F3G1.0 mm2
Connection Sizes 1“, 1¼“, 1½“
Delivery Rate Qmax. 12000 l/h
Delivery Height Hmax. 6.5 m
Submersion Depth max. 7 m
Min. Water Level 3.5 cm
Particle Size max. 35 mm
Fluid Temperature max. 35° C
Dimensions Ø 16 x 34 cm
Weight approx. approx. 5.6 kg

EU Declaration of Conformity

We, the Westfalia Werkzeugcompany, Werkzeugstraße 1, D-58093 Hagen,
declare by our own responsibility that the product
Submersible Sump Pump
Article No. 86 02 57
is according to the basic requirements, which are defined in the European Directives and their amendments.
2011/65/EU
Restriction of the Use of certain hazardous Substances in electrical and electronic Equipment (RoHS)
2014/30/EU
Electromagnetic Compatibility (EMC)
EN 55014-1:2017+A11, EN 55014-2:1997+A1+A2+AC,
EN 61000-3-2:2014, EN 61000-3-3:2013
2014/35/EU
Low Voltage Directive (LVD)
EN 60335-1:2012+AC+A11+A13+A1+A14+A2,
EN 60335-2-41:2003+A1+A2, EN 62233:2008+AC
The technical documentations are on file at the QA department of the Westfalia Werkzeug-company.

Hagen, den 13. Oktober 2021
Hagen, 13th of October 2021

Thomas Klingbeil,
QA Representative

Customer Services
Schweiz
Westfalia
Wydenhof 3a
CH-3422 Kirchheim (BE)
Telefon: (034) 4 13 80 00
Telefax: (034) 4 13 80 01
Internet: www.westfalia-versand.ch

Disposal
Dear Customer,
Please help avoid waste materials.
If you at some point intend to dispose of this article, then please keep in mind that many of its components consist of valuable materials, which can be recycled.
Please do not discharge it in the rubbish bin, but check with your local council for recycling facilities in your area.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals