HAYWARD Salt Chlorinator type Salt and Swim 2.0 Plus 22g Owner’s Manual

June 9, 2024
Hayward

Salt Chlorinator type Salt and Swim 2.0 Plus 22

information-icon

OWNER’S MANUAL

HAYWARD POOL EUROPE – 1070 Allée des Chênes – CS 20054 Saint Vulbas – 01154 Lagnieu Cedex – France

PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE

WARNING: Electrical hazard.
Failure to comply with these instructions can result in serious injuries or death.
THE EQUIPMENT IS INTENDED TO BE USED ONLY IN SWIMMING POOLS

WARNING – Disconnect the equipment from the mains supply before any intervention.
WARNING – All electrical connections must be carried out by a qualified approved electrician in accordance with the standards currently in force in the country of installation.

F NF C 15-100 GB BS7671:1992
D DIN VDE 0100-702 EW

SIST HD 384-7-702.S2

A| ÖVE 8001-4-702| H|

MSZ 2364-702:1994 / MSZ 10-533 1/1990

E| UNE 20460-7-702 1993, REBT ITC-BT-31 2002| M|

MSA HD 384-7-702.S2

IRL| IS HD 384-7-702| PL|

TS IEC 60364-7-702

I| CEI 64-8/7| CZ|

CSN 33 2000 7-702

LUX| 384-7.702 S2| SK|

STN 33 2000-7-702

NL| NEN 1010-7-702| SLO|

SIST HD 384-7-702.S2

P| RSIUEE| TR|

TS IEC 60364-7-702

WARNING – Check that the device is plugged into a power outlet that is protected against
short-circuits. The device must also be powered via an isolating transformer or a residual current device (RCD) with a nominal operating residual current not exceeding 30 mA.
WARNING – Ensure that children cannot play with the device. Keep your hands and any
foreign object away from openings and moving parts.
WARNING – Check that the supply voltage required by the product corresponds to the voltage of the distribution network and that the power supply cables are suitable for the product power supply.
WARNING – Chemicals can cause internal and external burns. To avoid death, serious injury and/or damage to equipment, wear personal protective equipment (gloves, goggles, mask, etc.) when servicing or maintaining this device. This device must be installed in an adequately ventilated place.
WARNING – To reduce the risk of electric shock, do not use an extension cable to connect the device to the mains. Use a wall socket.
WARNING – Chemicals can cause internal and external burns. To avoid death, serious injury and/or damage to equipment, wear personal protective equipment (gloves, goggles, mask, etc.) when servicing or maintaining this device. This device must be installed in an adequately ventilated place.
WARNING – To reduce the risk of electric shock, do not use an extension cable to connect the device to the mains. Use a wall socket.
WARNING – Carefully read the instructions that appear in this manual and on the device. Failure to comply with the instructions can cause injuries. This document must be given to every pool user, who should keep it in a safe place.
WARNING – This appliance can be used by children aged 8 years and over and by people with reduced physical, sensory or mental capabilities, or those who lack experience or knowledge, if they are supervised correctly or if they have been given instructions concerning safe use of the appliance and understand the hazards involved. Children must not play with the device. User maintenance and cleaning must not be carried out by unsupervised children.
WARNING – Use only original Hayward parts.
WARNING – If the power supply cable is damaged, it must be replaced by the manufacturer, the after-sales service or similarly qualified persons to avoid danger.
WARNING – The device must not be used if the power cord is damaged. An electric shock could occur. A damaged power cord must be replaced by the after-sales service or similarly qualified persons to avoid danger.

USE ONLY GENUINE REPLACEMENT PARTS

OWNER’S MANUAL

From 3 g salt / l Self-cleaning Sea water

1. UNIT DESCRIPTION

Sanitization system and controller for swimming pools.
Sanitization: Chlorine is produced by electrolysis of salt water, using
salt water of low salinity.
Production of sodium hypochlorite in the electrolysis cell is achieved
with a minimum of 3g salt per litre. The chlorine combats and
eliminates bacteria, viruses and pathogenic agents, and oxidizes
organic matter present in the water. The used sodium hypochlorite
reconverts into salt after a few hours.

“Do It Yourself” equipment:
The cell connects to the outside outside of the electronic box, with no
need to open the cover. The cell cable is 1.5m long.
The electronic box can be mounted on the wall without being opened.

Visual information:
The current disinfection status is shown by the colour of the box (blue,
green, purple, yellow, orange).

ELECTRONIC BOX

CELL

2. UNIT INSTALLATION

A. Filtration pump timer
B. Silex / glass / diatom filter
C. Recirculation pump
1. Electronic box
2. Electrolysis cell (always vertical)

Electricity consumption
Use of a 16 A time delay circuit breaker is recommended
with this equipment. Where the power supply is shared
with other devices, please consult a technician for correct
sizing of your installation.

Product| Maximum
consumption| g Cl2/h
---|---|---
8 Gr/h| 80 W| 8
16 Gr/h| 130 W| 16
22 Gr/h| 145 W| 22
33 Gr/h| 165 W| 33

3. WALL-MOUNTING THE EQUIPMENT

mount tools

Step 1: Without opening the unit cover, screw the 4 suspension eyes to the box from behind.
Step 2: Mark the positions of the 4 eyes using the drilling template.
Step 3: Drill and insert the 4 rawl plugs into the wall.
Step 4: Screw in the 4 wall screws and hang up the unit.

USE ONLY GENUINE REPLACEMENT PARTS

4. ASSEMBLY AND CONNECTION OF THE CELL0

Step 1: Install the cell in a vertical position.
Step 2: Install the cell on by-pass.
Step 3: Install the cell at the highest point of the installations.
Step 4: Connect the cell and the gas detector to the electronic box.
N.B.: If the unit is being installed for a pool that has already
been treated with chlorine, we recommend total renewal of all
water in the pool so that the cyanuric acid (chlorine stabiliser)
does not distort measurements made by the rX (redox) probe.

5. ELECTRICAL CONNECTIONS TO ELECTRONIC BOX

sensor connecting

6. ELECTROLYSIS (from 3 g salt/L)

During normal operation, the LEDs light up blue.
The equipment has 5 production levels, with each level featuring 2 LEDs.
Adjust the production, in grams of chlorine/hour, using the buttons ‘+’ and ‘-’.
The levels increase in increments of 20%.
Example : For a 22 Gr Cl2/h unit:

Selected level(s) 1,3,5

% of production 20 % 60 % 100 %

g Cl2/h 4.4 g Cl2/h 13.2 g Cl2/h 22 g Cl2/h

USE ONLY GENUINE REPLACEMENT PARTS

7. CHLORINATION BOOST MENU

1. Press and hold the ‘+’ button for 3 seconds to enter the menu dedicated to chlorination boost.
2. The LEDs light up green.
3. Adjust the boost production using the buttons ‘+’ and ‘-’.

From this moment on, production will be maintained for 24h as long as water is flowing through the unit. After this time period, the unit will return to its previous production situation.

8. ‘LOW’ ALERT

If the LEDs light up yellow, the unit has not reached the desired production.
This may be due to various factors:
– Lack of salt.
– Scaled-up cell.
– Exhausted cell.
– Low water temperature.
Blue LEDs show the configured production and yellow LEDs show the actual production

9. WATER FLOW ALARM

If the 3 LEDs in the centre are flashing orange, the unit is not producing.
This means that there is no water flow inside the installation. Check
– Flow switches,
– Configuration (see section 11),
– For correct flow.

10. REDUCING PRODUCTION USING THE COVER

1. Connect the cover to the box (see section 5).
2. Press and hold the ‘-’ button for 3 seconds to enter the menu dedicated to reduction
of production.
3. The LEDs light up purple.
4. Adjust to the desired production using the buttons ‘+’ and ‘-’.
5. The reduction is applied to the production already configured.
6. Save the configuration by pressing the ‘+’ button until you return to the previous
menu.

When the cover contact is closed, the LEDs will automatically light up purple and
prodution will be limited to the programmed setpoint.

11. SELECTING THE FLOW SWITCH

1. Connect the mechanical flow switch to the box (see section 5).
2. Press the ‘-’ and ‘+’ buttons simultaneously and hold for 3 seconds to enter the menu.
3. Select the position using the buttons ‘+’ and ‘-’.
Position 1: Gas sensor only.
Position 3: Flow switch only.
Position 5: Gas sensor + flow switch.
4. Save the configuration by pressing the ‘+’ button until you return to the previous menu.

USE ONLY GENUINE REPLACEMENT PARTS

Hayward is a registered trademark
of Hayward Industries, Inc.
© 2020 Hayward Industries, Inc.