HAYWARD EasyChem Single pH Dosing Pump User Guide
- June 1, 2024
- Hayward
Table of Contents
EasyChem Single | pH · ORP
QUICK START GUIDE
EasyChem Single pH Dosing Pump
WARNING: Electrical hazard.
Failure to comply with these instructions can result in serious injuries or
death.
THE EQUIPMENT IS INTENDED TO BE USED ONLY IN SWIMMING POOLS
WARNING – Carefully read the instructions that appear in this manual and
on the device. Failure to comply with the instructions can cause injuries.
This document must be given to every pool user, who should keep it in a safe
place.
WARNING – Disconnect the equipment from the mains supply before any
intervention.
WARNING – All electrical connections must be carried out by a qualified
approved electrician in accordance with the standards currently in force in
the country of installation or, failing this, in accordance with the
international standard IEC 60334-7-702.
F | NF C 15-100 | GB | BS7671:1992 |
---|---|---|---|
D | DIN VDE 0100-702 | EW | SIST HD 384-7-702.S2 |
A | ÖVE 8001-4-702 | H | MSZ 2364-702:1994 / MSZ 10-533 1/1990 |
E | UNE 20460-7-702 1993, REBT ITC-BT-31 2002 | M | MSA HD 384-7-702.S2 |
IRL | IS HD 384-7-702 | PL | TS IEC 60364-7-702 |
I | CEI 64-8/7 | CZ | CSN 33 2000 7-702 |
LUX | 384-7.702 S2 | SK | STN 33 2000-7-702 |
NL | NEN 1010-7-702 | SLO | SIST HD 384-7-702.S2 |
P | RSIUEE | TR | TS IEC 60364-7-702 |
WARNING – Check that the device is plugged into a power outlet that is
protected against short-circuits. The device must also be powered via an
isolating transformer or a residual current device (RCD) with a nominal
operating residual current not exceeding 30 mA.
WARNING – Ensure that children cannot play with the device. Keep your
hands and any foreign object away from openings and moving parts.
WARNING – Check that the supply voltage required by the product
corresponds to the voltage of the distribution network and that the power
supply cables are suitable for the product power supply.
WARNING – Chemicals can cause internal and external burns. To avoid
death, serious injury and/or damage to equipment, wear personal protective
equipment (gloves, goggles, mask, etc.) when servicing or maintaining this
device. This device must be installed in an adequately ventilated place.
WARNING – The unit shall not be operated when there is no water flow in
the cell.
WARNING – To reduce the risk of electric shock, do not use an extension
cable to connect the device to the mains. Use a wall socket.
WARNING – Use, cleaning or maintenance of the device by children over 8
years of age or by people with impaired physical, sensory or mental
capacities, or a lack of experience or expertise, should only take place once
they have received appropriate instruction and under adequate supervision of
an adult who is responsible for them, to ensure the device is handled safely
and avoid all risk of danger.
WARNING – Use only original Hayward® parts.
WARNING – If the power supply cable is damaged, it must be replaced by
the manufacturer, the after-sales service or similarly qualified persons to
avoid danger.
WARNING – The device must not be used if the power cord is damaged. An
electric shock could occur. A damaged power cord must be replaced by the
after-sales service or similarly qualified persons to avoid danger.
GENERAL
Before carrying out ANY work inside control panel of the EasyChem Single
device, make sure you disconnect it from the power supply.
Failure to comply with the instructions contained in this manual could cause
injury to people and/or damage to the appliance and the system.
PACK CONTENTS
Model
Item’
| EASY-CHEM-SPH| EASY-CHEM-SRXG| EASY-CHEM-SRXGS
---|---|---|---
A| 1| 1| —
B| 1| 1| —
C| 1| 1| —
D| 2| 2| 1
E| 1| 1| —
F| 1| 1| —
G| 1| 1| 1
H| 1| 1| 1
I| 1| —| —
J| —| 1| 1
K| 1| —| —
L| —| 1| 1
M| 1| 1| 1
N| 1| 1| —
*NOTE: The values from the table represent the number of items inside the package.
SPECIFICATIONS
Specifications| EASY-CHEM-SPH| EASY-CHEM-SRXG| EASY-CHEM-
SRXGS
---|---|---|---
Range| 3.8 ÷ 8.2 pH (1)| 400÷999 mV (1)| 400÷999 mV (*1)
Accuracy| ± 0.02 pH| ± 2 mV| ± 2 mV
Device precision| ± 0.1 pH| ± 10 mV| ± 10 mV
Pump flow rate| 1.5 l/h| 1.5 l/h| —
Power supply| 230 Vac 50-60Hz| 230 Vac 50-60Hz| 230 Vac 50-60Hz
Consumption| 13,5 Watt| 13,5 Watt| 9 Watt
Dosage method| Proportional Set Point adjustable| Constant dosing Set Point
adjustable
Display| 4 digits with 7 segments
Probe calibration| Automatic
Max. back-pressure| 1.5 Bar| 1.5 Bar|
Weight| 1.3 Kg| 1.3 Kg| 1.0 Kg
Dimensions (WxHxD)| 120 x 260 x 136 mm| 120 x 260 x 136 mm| 120 x 260 x 136 mm
(*1 ) The pump has galvanised electrical insulation and measure insulation.
Default parameters table
Item | Easy Chem SPH | Easy Chem SRXG | Easy Chem SRXGS |
---|---|---|---|
Set point | 7.4 pH | 750 mV | 750 mV |
Alr min | 6.2 pH | 450 mV | 450 mV |
Alr Max | 8.2 pH | 900 mV | 900 mv |
Over feed alarm | OFF | OFF | OFF |
Power On Delay | OFF | OFF | OFF |
For the complete instruction manual, scan the QR-code
https://bit.ly/easychem-single Hayward® is registered trademark of
Hayward®Holdings, Inc.
© 2023 Hayward® Holdings, Inc.
0000139977 · EasyChem Single | pH · ORP