HAYWARD ProChem Single Chemical Regulator User Guide
- June 1, 2024
- Hayward
Table of Contents
HAYWARD ProChem Single Chemical Regulator
Product Information
Specifications
- Power supply: W: 120, H: 258, D: 135 mm
- Consumption: Not specified
- Pump flow rate: Not specified
- Max. back-pressure : Not specified
- Pump state Measure scale : Not specified
- Device precision: Not specified
- Accuracy: Not specified
- Probe calibration : Not specified
- Weight : Not specified
- Dimensions : Not specified
Product Usage Instructions
Safety Instructions
- The equipment is intended for use only in swimming pools. Failure to comply with the instructions can cause injuries.
- Keep this document in a safe place and provide it to every pool user.
- Ensure installation complies with relevant electrical standards.
Installation
- Power the device via an isolating transformer or residual current device with a nominal operating residual current not exceeding 30 mA.
- Ensure adequate ventilation during installation.
Maintenance
- Disconnect the device from the power supply before carrying out any work inside the control panel.
- Replace damaged power cords with the help of after-sales service or qualified persons.
Pack Contents
-
* **A:** PVC Crystal 4×6
- B: Polyethylene
- C : FPM Lip suction hose (4 m) delivery hose (5m) valve (3/8 GAS)
Usage
- Follow the probe calibration instructions for accurate measurements.
- Ensure all components are securely connected before operation.
FAQ
- Q: What should I do if the device malfunctions?
- A : In case of malfunction, contact after-sales service or qualified persons to avoid danger.
- Q: How often should I calibrate the probes?
- A : Calibration frequency depends on usage, but regular calibration is recommended for accurate readings.
WARNING: Electrical hazard.
Failure to comply with these instructions can result in serious injuries or
death.
THE EQUIPMENT IS INTENDED TO BE USED ONLY IN SWIMMING POOLS
WARNING – Carefully read the instructions that appear in this manual and
on the device. Failure to comply with the instructions can cause injuries.
This document must be given to every pool user, who should keep it in a safe
place.
WARNING – Disconnect the equipment from the main supply before any
intervention.
WARNING – All electrical connections must be carried out by a qualified
approved electrician in accordance with the standards currently in force in
the country of installation or, failing this, in accordance with the
international
standard IEC 60334-7-702.
F | NF C 15-100 | GB | BS7671:1992 | |
---|---|---|---|---|
D | DIN VDE 0100-702 | EW | SIST HD 384-7-702.S2 | |
A | ÖVE 8001-4-702 | H | MSZ 2364-702:1994 / MSZ 10-533 1/1990 | |
E | UNE 20460-7-702 1993, REBT ITC-BT-31 2002 | M | MSA HD 384-7-702.S2 | |
IRL | IS HD 384-7-702 | PL | TS IEC 60364-7-702 | |
I | CEI 64-8/7 | CZ | CSN 33 2000 7-702 | |
LUX | 384-7.702 S2 | SK | STN 33 2000-7-702 | |
NL | NEN 1010-7-702 | SLO | SIST HD 384-7-702.S2 | |
P | RSIUEE | TR | TS IEC 60364-7-702 |
WARNING
- Check that the device is plugged into a power outlet that is protected against short circuits. The device must also be powered via an isolating transformer or a residual current device (RCD) with a nominal operating residual current not exceeding 30 mA.
- Ensure that children cannot play with the device. Keep your hands and any foreign object away from openings and moving parts.
- Check that the supply voltage required by the product corresponds to the voltage of the distribution network and that the power supply cables are suitable for the product power supply.
- Chemicals can cause internal and external burns. To avoid death, serious injury and/or damage to equipment, wear personal protective equipment (gloves, goggles, mask, etc.) when servicing or maintaining this device. This device must be installed in an adequately ventilated place.
- The unit shall not be operated when there is no water flow in the cell.
- To reduce the risk of electric shock, do not use an extension cable to connect the device to the mains. Use a wall socket.
- Use, cleaning or maintenance of the device by children over 8 years of age or by people with impaired physical, sensory or mental capacities, or a lack of experience or expertise, should only take place once they have received appropriate instruction and under adequate supervision of an adult who is responsible for them, to ensure the device is handled safely and avoid all risk of danger.
- Use only original Hayward® parts.
- If the power supply cable is damaged, it must be replaced by the manufacturer, the after-sales service or similarly qualified persons to avoid danger.
- The device must not be used if the power cord is damaged. An electric shock could occur. A damaged power cord must be replaced by the after-sales service or similarly qualified persons to avoid danger
GENERAL
Before carrying out ANY work inside the control panel of the ProChem device, make sure you disconnect it from the power supply. Failure to comply with the instructions contained in this manual could cause injury to people and/or damage to the appliance and the system
PACK CONTENTS
System
**Item***
| Single pump
---|---
ProChem pH (PRO-CHEM-SPH)| ProChem ORP (PRO-CHEM-SRXG)
A| 1| 1
B| 1| 1
C| 1| 1
D| 1| 1
E| 3| 3
F| 1| 1
G| 1| 1
H| 1| 1
I| 1| 1
L| 1| —
M| —| 1
N| 1| —
O| 1| —
P| —| 1
Q| 1| 1
R| 1| 1
S| 1| 1
T| 1| 1
NOTE: The values from the table represent the number of items inside the package.
SPECIFICATIONS
Specifications | PRO-CHEM-SPH / PRO-CHEM-SRXG |
---|---|
Power supply | 230 VAC 50-60 Hz |
Consumption | 20 Watt |
Pump flow rate | 1.5 l/h |
Max. back-pressure | 1.5 bar |
Pump state | Pause – Supply |
Measure scale | 0.0 ÷ 14.0 pH; 0 ÷ 1000 mV |
Device precision | ± 0.1 pH; ±10mV |
Accuracy | ±0.02pH, ±2mV |
Probe calibration | Automatic |
Weight | 1 Kg |
Dimensions | W: 120, H:258, D:135 mm |
Default parameters
n | Item | Value |
---|---|---|
1 | Language | EN |
2 | Set Point value | 7.4 pH |
3 | Dosing method | Acid (pH) |
4 | OFA Time | OFF |
5 | Calibration | Full |
6 | Circulation pump | ON |
7 | Flow Input | NO (normally open) |
8 | Power ON Delay | OFF |
9 | Flow Delay | OFF |
Measure alarm ranges default parameters
n | Item | Limits |
---|---|---|
1 | Temp. Measure min | + 10°C |
2 | Temp. Measure Max | + 38°C |
3 | pH Measure min | 6 pH |
4 | pH Measure Max | 8.0 pH |
5 | ORP Measure min | +450 mV |
6 | ORP Measure Max | +850 mV |
For the complete instruction manual, scan the QR code
Hayward® is a registered trademark of Hayward® Holdings, Inc. © 2023 Hayward® Holdings, Inc.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>