Product description
The USB-Connector allows to easily connect a computer to a KNX-network. The
included software is installed on a Windows device that accesses the connected
KNX bus via the USB connector.
The included Bus Monitor and IP Router software enable the user to read or
send telegrams on the KNX bus. The included software also allows the
parameterization of actuators via the Engineering Tool Software (ETS).
The USB-Connector has a compact and robust plastic housing which enables
mobile use. The available connection adapters allow the flexible use of the
device.
1.1 Product properties
- Connections: USB 2.0, type A and D-Sub-9-Pin, male
- Adapter to KNX (optionally available)
- Cable length: 65 cm
- Power supply via USB
- Included Software: Bus-Monitor, IP-Router and ETS-Integration
- Extended operating temperature range from -40 ° C to 85 ° C
- Protection class: IP20 (inhouse use)
1.2 System requirements
- A USB port on a Windows device
- Operating system Windows 10, 8.1, 7 (32/64-bit)
- KNX Bus connection defined in KNX specification
- Ethernet connection (For the use of the IP Router)
Note: The USB-Connector only supports Windows as the operating system.PEAKnx does not guarantee that the software and hardware will function without problems in conjunction with other operating systems or software.
1.3 Delivery
-
USB-Connector
-
D-Sub-to-KNX-Adapter
− KNX-WAGO-243-211-Adapter (optional) (PNX21-10002)
− KNX-WAGO-243-211-Adapter, encapsulated (optional) (PNX21-10003)
− DIN rail (top hat) adapter set* (optional) (PNX21-10008)
− DIN rail (top hat) adapter (optional, as additional purchase option) (PNX21-10007) -
Included software (available on USB flash drive)
− Bus Monitor
− IP Router
− ETS Integration -
User manual (this document)
-
YOUVI Quick Start Guide (available on USB flash drive)
*Includes an adapter cable (length: 2 m) to connect the DIN rail adapter to the USB-Connector and a DIN rail adapter
Included software
The scope of delivery includes a USB flash drive containing all the software
needed to operate the USB-Connector.
The USB-Connector is available in two bundles with different software:
- USB-Connector and YOUVI: Bus Monitor, IP Router, visualization
- USB-Connector and standalone software: Bus Monitor and IP Router
2.1 YOUVI software package (Bus Monitor, IP Router, visualization)
The YOUVI Basic visualization software included in the scope of delivery is
used to control
KNX devices such as sockets, switches, lights, dimmers, RGB lights, heaters,
blinds or shutters.
Thanks to the IP Router included in the software package, YOUVIs visualization
can be connected to the KNX infrastructure of the house with the USB-Connector
and a Windows computer or server without additional components. Only an
Ethernet connection is necessary for the software to function. In addition to
visualization and IP Router, a Bus Monitor is also included in the scope of
delivery, which can record and filter the KNX traffic.
In addition to the basic functions for controlling KNX devices, YOUVI can be
extended via modules for IP camera connection, creation of logics, control via
app on the road or voice control.
Note: For the YOUVI installation, please pay special attention to the
YOUVI quick reference guide and the information on KNX project preparation to
enable the automatic reading of the project. This quick reference guide is
included in the delivery.
Note: When working with the YOUVI software, the Google Chrome Browser or
the Microsoft Edge Browser is recommended.
Further information about YOUVI can be found in the YOUVI Help, which can be
opened in the program YOUVI Dashboard > ? > Help. Here you will also find the
current range of functions of the software under: YOUVI Visu > Scope of
functions.
2.2 Standalone software (Bus Monitor, IP Router)
For the software installation procedure, please refer to the enclosed Quick
Start Guide or Section 5.1 Installing the Bus Monitor and IP Router software
Note: To be able to use the USB-Connector with the ETS without having the
IP Router software installed, it is necessary to execute the ETS Integration,
see section 5.2 Using the USBConnector exclusively with the ETS
2.2.1 Bus Monitor
The Bus Monitor in combination with the USB-Connector provides an overview of
the KNX bus.
Its tabular structure provides a clear overview of all telegrams sent via the
KNX bus. It can be used to log short telegram sequences or long-term
recordings over several days. Additionally any group addresses or KNX commands
can be sent. Further functions are the filter options as well as the data
export of CSV files. In the advanced filter settings different filters are
defined and saved, so that several filters can be applied in parallel. The Bus
Monitor enables the import and storage of ETS group addresses from several
projects at the same time. He supports 3-level, 2-level and free group address
styles. That way collected information of the bus communication between the
applications and the KNX network can be stored as log files.
Note: The Bus Monitor is only compatible with the USB-Connector from PEAKnx.
2.2.2 IP Router
The IP Router software sets up a connection between the KNX bus and the IP
network using the USB-Connector. Therefore, any KNXnet/IP client can use the
IP Router to communicate with the KNX network (for example the ETS). This
means that multiple software distributions can access the USB-Connector at the
same time so that the Bus Monitor can be used simultaneously with the ETS.
Also actuator programming via the ETS is possible that way. From the KNX
specification the IP Router is represented as KNXnet/IP Router, a class B
KNXnet/IP device. It therefore supports the following service types:
- Core function of a KNXnet/IP Router
- Device Management
- Tunneling
- Routing
Power supply
The device is powered by the USB port and requires no external power supply. In general, the device is operated internally with a supply voltage of 5 V DC.
KNX bus connection
4.1 KNX connection adapter
The adapter with which the USB-Connector is connected to the KNX bus via the
D-Sub 9P plug, exists in an encapsulated version, without a plastic housing or
as DIN rail adapter.
4.1.1 KNX WAGO 243 211 adapter
The connection adapter forms a transition from the D-Sub-9-Pinconnector to a
WAGO 243 211 connector terminal. These have prevailed in most KNX
installations. The adapter is supplied as a simple circuit board construction
without housing and is suitable for installation in non-visible locations.
4.1.2 KNX WAGO 243 211 adapter, encapsulated
The KNX connection adapter from the D-Sub-9-Pin to the WAGO-243-211 connector
terminal with housing also connects the USB-Connector to the KNX bus. The
encapsulated model is especially suitable for the mobile use.
4.1.3 DIN rail adapter set
The KNX DIN rail adapter is connected to the KNX bus before use and installed
in the switch cabinet.
Afterwards the USB-Connector is connected to the KNX bus by means of the 2 m
extension cable (part of the set). While the inexpensive DIN-rail adapter can
be permanently installed at different locations, only one interface (the USB-
Connector) is needed for the KNX access, which can be connected to the KNX bus
on site without the need for additional tools.
Note: The USB-Connector can only be connected to the DIN rail adapter via the adapter cable.
Start-up
Note: If you want to operate more than one KNX-IP Router in the same KNX
network, the multicast addresses must be different. If they both communicate
over the same multicast address, this will result in a circulating message.
Note: Keep the USB-Connector away from water and moisture!
The software required to use the USB-Connector is located on the USB flash
drive supplied.
The software package includes an IP Router, a Bus Monitor and an ETS
integration tool that allows the use of the USB-Connector if the IP Router
software is not installed.
5.1 Installing the Bus Monitor and IP Router software
To install one or both components, proceed as follows:
- Run the “PEAKnx USB Connector” application stored on the USB flash drive to start the installation wizard.
- Open the tab “Install”.
- Run the “Setup Wizard”.
- Follow the installation instructions.
During installation, you will be asked whether you want to install the Bus Monitor software and/or the IP Router software, so you can also install only one of the two components.
5.2 Using the USB-Connector exclusively with the ETS
The ETS Integration is a small tool for a one-time run on a computer, which
configures the local ETS-Installation, so that it can be used together with
the KNX-USB-Connector. To do this, the ETS must already be installed on the
computer. It is automatically installed by the installation wizard when the IP
Router and Bus Monitor are installed. If you want to use the USB-Connector
exclusively with the ETS, you can also run the ETS integration tool on its
own.
For the installation proceed as follows:
- Close ETS.
- Run the “PEAKnx USB Connector” application stored on the USB flash drive to start the installation wizard.
- Open the tab “Install”.
- Click on “ETS Integration” > “Execute Now”.
This starts the automatic configuration.
After the completion, a summary of the configuration is shown.
5.3 Connecting and disconnecting the hardware
Connecting the hardware
- Connect the D-Sub-9P connector* of the USB-Connector to the KNX bus using a suitable adapter, see chapter 4 KNX bus connection.
- Connect the USB port of the USB-Connector to a Windows device.
*More information on the Pin-assignment of the D-Sub connector is located in the appendix under D-Sub-Pin-Assignment.
Disconnecting the hardware
You can unplug the adapter from the computer‘s USB port without preparation.
Operation
6.1 Status LED
The USB-Connector has an LED, which shows different colors and blinking
patterns, depending on the Connector‘s status.
LED | Blink pattern | Status |
---|---|---|
On | One-time blink | USB-Connector is plugged in, LED-Test |
Green | Slow blinking | USB-Connector is connected and drivers are loaded |
Green | Fast blinking | USB-Connector is receiving data |
Off | – | USB-Connector is not plugged in or out of order |
Technical support
If you experience problems with your USB-Connector, please contact our PEAKnx
Support Team:
− Mail: support@peaknx.com
− Create a Support Ticket: support.peaknx.com
− Tel.: +49-6151-279 1825
Technical data
Supply
USB-side| + 5 V DC
KNX-side| + 24 V DC
Max. Power usage USB| 100 mA
Ports
USB| 1 x USB-connector, type-A
Fieldbus| 1 x D-Sub-9-Pin, male
Software requirements
ETS compatible| ETS 5 – 6
Operating system| Windows 10, 8.1, 7 (32/64-Bit)
CPU| 1 GHz
Memory (RAM)| 1 GB (32 Bit)/2GB (64 Bit)
Hard disc space| 1 GB
Grafics| DirectX 9 or newer
.NET Version| ID 4.5.1 (included in Windows 8.1/10)
Measures
Size of the interface| 86 x 42.5 x 20.5 mm
Weight of the interface with USB cable| 86 g
Environment
Operating temperature| -40 °C to 85 °C
Temperature for transport and storage| -40 °C to 100 °C
Relative humidity| 15 to 90 %, no condensation
Environment
Protection class (DIN EN 60529)| IP20
Guidelines fulfilled| Directive 2014/30/EU (EMC): DIN EN
55024:2016-05 DIN EN 55032:2016-02;
Directive: 2011/65/EU (RoHS2): DIN EN IEC 63000:2019-05
Dimension drawing of the USB-Connector
D-Sub-Pin-Assignment
Subject to change without notice
Content changes in this documentation, which serve the technical progress, are
made without prior notice. This documentation has been prepared with great
care and will be revised at regular intervals. Nevertheless, we cannot
guarantee complete accuracy. All known errors are eliminated in new editions.
For any indication of errors in this documentation, we are always grateful.
Conformity
Conformity is confirmed by the attached CE label. The considered standards can
be found in Chapter 8 Technical data.
The complete declaration of conformity can be found on the following page.
Disposal notes
Do not dispose the old device in the household waste!
Observe the EU Directive 2012/19/EU on environmentally friendly disposal of
used electrical/electronic equipment.
Waste of electrical and electronic equipment can
- contain hazardous substances that are harmful to health and the environment.
- contain valuable substances that are to be reused.
Therefore, do not dispose of with household waste.
Waste of electrical and electronic equipment can be returned to public
collection points.
EU Declaration of Conformity
This declaration applies to the following product:
Product name: USB-Connector
Item number(s): PNX-005-A17-00001
Manufacturer: DOGAWIST Investment GmbH
Otto-Roehm-Strasse 69
64293 Darmstadt
Germany
**** We declare under our sole responsibility that the mentioned product is
in conformity with the following directives and the affiliated harmonized
standards:
EU Directive 2011/65/EU (RoHS 2) + 2015/863/EU (amended list of restricted
substances)
DIN EN IEC 63000:2019-05; VDE 0042-12:2019-05
Technical documentation for the assessment of electrical and electronic
products with respect to the restriction of hazardous substances (IEC
63000:2016); German version EN IEC 63000:2018
Electromagnetic Compatibility
- DIN EN 55024:2016-05; VDE0878-24:2016-05
- DIN EN 55032:2016-02; VDE 0878-32:2016-02
Darmstadt, 29. September 2020 Uwe Wilhelm, Managing Director
About PEAKnx
As a manufacturer of innovative hardware and software components, PEAKnx
develops products for future-proof building automation. For example,
individual front-end panels including visualization, which make all
information of an intelligent building available at a central point.
Great importance is attached to the longevity of the products and the
qualitative interaction of design and functionality.
As the newest division of the PEAK group headquartered in Darmstadt, Germany,
PEAKnx can draw from more than 30 years of experience in hardware and software
development. Through a broad network of certified partners, PEAKnx also offers
the associated services – from consulting to the installation and
implementation of automation projects. The goal is to make home and building
automation comfortable, cost-saving and future-proof through innovative
solutions.
The product names mentioned in this document may be brands or registered
trademarks of their respective owners. These are not explicitly labeled with
“™” or “®”.
© PEAKnx GmbH
Otto-Röhm-Strasse 69
64293 Darmstadt
Germany
www.peaknx.com
info@peaknx.com
Document version: 1.2.1
Date: 02.09.22
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>