  • Product: Control 12
  • Item Number: PNX12-20001
  • Touch-Panel with various features including microphone, camera, USB ports, Ethernet port, KNX-Wago installation clamp, USB C port, etc.
  • Panel Power Supply: 24V DC

Product Usage Instructions

Paneleinbau und -Installation

  • Before starting the installation, make sure to carefully read all safety instructions provided in the manual.

Vorbereitung

  • Prepare the necessary tools and components for the panel installation.

Einbau in Mauerwerk

  • For installation in solid walls, follow the step-by-step instructions provided in the manual.

Einbau in eine Hohlwand

  • For installation in hollow walls, follow the specific guidelines mentioned to ensure proper mounting.

Spannungsquelle montieren

  • Mount the power supply source as per the instructions provided.
  • Ensure correct polarity while connecting the power cables.

Erstinbetriebnahme und Bedienung

  • After successful installation, proceed with the initial setup and operation of the Control 12 panel.

Software

  • The panel can be operated with the included YOUVI software or other compatible Windows software. Follow the software setup instructions accordingly.

FAQ

Q: What should I do if I encounter issues with my Control 12?

A: In case of any problems, please contact the PEAKnx Support Team via email at [email protected] or create a support ticket at https://helpdesk.peaknx.com/ or call +49-6151-279 1825 for assistance.

Product Item number
Control 12 PNX12-20001
  • This user manual contains the most important information for safely operating Control 12.
  • Please study this manual carefully before using the device. This applies to all persons who come into contact with the device.

Warning symbols and signal words used in this manual

Warning Obey warning to avoid death or serious injury
Caution Obey instructions to avoid personal injury or damage to

property
Note| Instructions and facts to be followed
Tip| Additional, useful hints

Important safety instructions, please read before installation!

  • Warning The device may carry dangerous voltages if improperly installed!
  • Installation and commissioning may only be carried out by specially trained personnel (qualified electricians).

Caution Avoid damage to the panel!

  • Only use the panel in perfect condition, as well as under its intended use, in a way that is safe and aware of the hazards and in compliance with this manual!
  • Do not make any changes, attachments, or conversions to the device without the manufacturer’s permission!
  • In particular, faults that could impair safety are immediately eliminated!

Product Description

Touch panel, front viewPEAKNX-PNX12-20001-Control-12-Getting-Started-
fig-1

Position| Description|
---|---|---
1| 4 x intake for glass cover
2| Left: On/Off button, middle: activates status LED (C6), right: actuation > 5 s starts KNX reset
3| 4 x slotted holes for fixing the panel
4| Microphone
5| Camera
6| 2 x USB 2.0| Status LED:

▪   Panel shut down: Status LED lights up permanently in red

▪   Panel booted: Status LED off, middle button (C2) pressed: LED lights up green

▪   Blue: KNX reset is being carried out

7| Touchscreen
8| Windows Home button
9| Sensors: WLAN antenna, brightness sensor, and proximity sensor

Touch panel, rear viewPEAKNX-PNX12-20001-Control-12-Getting-Started-
fig-2

Position| Description|
---|---|---
1| 1000 Mbit Ethernet port
2| KNX-Wago 243-211 installation terminal
3| USB C 3.2 Gen2| Status LED:

▪   Green: voltage in the correct range

▪   Red: over- or undervoltage, remove the power supply!

▪   Off: no voltage or connected with reverse polarity

4| Panel power supply: 24 V DC, GND

Introduction

Note: Detailed instructions can be found on the supplied USB flash drive.

Intended use

  • Use as an operating panel (input via touch) for KNX-controlled devices
  • Intercom station for compatible door stations
  • Indoor operation, in landscape orientation, displays parallel to the wall
  • Do not use the device in safety-relevant, humid, dusty, or vibration-loaded environments and not under direct sunlight. Do not allow small children to operate the device!

Scope of delivery

  • Control 12 panel
  • USB flash drive: YOUVI Basic software package, Control 12 user manual
  • Brief instructions for commissioning the panel and software
  • Network connector
  • Network patch cable

Panel mounting and installation

Important safety and handling information

  • Commissioning may only be carried out by qualified electricians!
  • Pay attention to the „Five Safety Rules“ (DIN VDE 0105, EN 50110).
  • Before installation, make sure that all connecting cables of the device are undamaged.

Avoid damage to the panel!

  • The panel may only be installed in landscape format and parallel to the wall to ensure ventilation of the computer in the panel by convection.
  • Tip: Further instructions for surface mounting or mounting using adapters are supplied with the respective surface-mounted frame or adapter.

Preparation

Note: We recommend securing the panel since in rare cases the panel must be completely disconnected from the power supply.

Necessary accessories for the installation of the panel:

  • Flush-mounted box (PNX12-10004) or surface-mounted frame (PNX12-10005)
  • Glass cover
  • The power supply unit 24 V DC for DIN rail (PNX12-10010) (recommended) or
  • The power supply unit 24 V DC for the flush-mounted box (PNX12-10011)

Flush-mounted installation

Tip: Choose the installation height of the panel according to the height of the primary user so that the top edge of the panel is at his/her eye level. A slightly lower screen prevents fatigue of the arms during operation.

Installation in brickworkPEAKNX-PNX12-20001-Control-12-Getting-Started-
fig-3

  1. Make a recess of H x W: 194 x 252 mm in the wall. Therefore, use the template provided. The flush-mounted box must later be flush with the plastered wall.
  2. Depending on the cable position, press the circular plates at the top or bottom out of the box and insert the supplied self-sealing grommets to prevent damage to the cable.
  3. When inserting the flush-mounted box, route the supply and communication cables (Ether-net, KNX) through different holes in the flush-mounted box to avoid possible interference.
  4. Use the template as a splash guard during the filling of the edges.

Installation in a cavity wallPEAKNX-PNX12-20001-Control-12-Getting-
Started-fig-4

  1. Make a recess of H x W: 194 x 252 mm in the wall. Therefore, use the template supplied. The flush-mounted box must later be flush with the plastered wall.
  2. Glue or screw the two wooden blocks supplied into the cavity wall.
  3. Depending on the cable position, press the circular plates at the top or bottom out of the box and insert the supplied self-sealing grommets to prevent damage to the cable.
  4. When inserting the flush-mounted box, route the supply and communication cables (Ether-net, KNX) through different holes in the flush-mounted box to avoid possible interference.
  5. Screw the flush-mounted box on the sides to the wooden blocks using the four screws.
  6. Use the template as a splash guard during the filling of the edges.

Mounting the voltage source

Note: In case a power supply unit is used in the flush-mounted box, you will find the corre-sponding instructions in the manual

Warning Avoid electric shock when touching live parts!

  • Disconnect all associated circuit breakers before working on the device.
  • Cover live parts in the surroundings.

Preparing the voltage source for the DIN rail (recommended)

  • Use a power source of the following specifi cation: 24 V DC, 2,5 A for the control cabinet, item number: PNX12-10010
  • Connect the cable wires of the power supply unit with the pluggable screw terminal included in the scope of delivery. Please pay attention to the polarity.
  1. Place the power supply unit (PNX12-10011) in the fl ush-mounted box.
  2. Connect the 24 V side of the power supply unit with the plug-in screw terminal included in the scope of delivery. Please pay attention to the polarity.
  3. Connect the mains cable to the 230 V side of the power supply unit.

Note: When using a third-party flush-mounted box or using a power supply unit in the fl ush-mounted box, please refer to the manual for further instructions on earthing.

Connecting and mounting the panel

Preparation

  1. Place the screws (M3x12) included in the scope of delivery within reach for fi xing the panel within the fl ush-mounted box.
    • Connecting the panel
  2. Connect the Ethernet cable to the panel.
  3. Plug the KNX cable with the colors red (+) and black (-) into the KNX-terminal, as indicated on the panel.
  4. Push the prepared 24 V connector terminals into the appropriate connectors in the panel. Pay attention to the polarity.
    • Fastening the panel
  5. Install the panel in the fl ush-mounted box. For doing so, use the four countersunk screws (M3x12) for fi xing it in the slotted holes.
  6. Place the glass cover with the magnetic holders into the four intakes provided and continue until the glass rests against all four corners of the touch screen.
  7. Ensure that the opening for the camera is positioned on the upper screen.

Initial commissioning and operation

Caution Avoid damage to the panel due to early commissioning!

  • Note the climatic conditions at the installation site!
  • Before switching on the mounted device, the device must have adapted to the climatic conditions at the installation site.
  • Temperature and humidity differences can cause damage to the unit.

Caution Avoid damage to the glass cover and display!

  • The touch-sensitive surface can easily be damaged! Only use your fingers or a touchpad to operate the panel. Do not use sharp or pointed objects.
  • Do not use harsh detergents, scouring agents, acids, or organic solvents. Do not use any sharp objects for cleaning.
  • Do not let any moisture get into the unit. Do not spray cleaning agents directly onto the surface of the touchscreen.

Switching the Control 12 on and off

  • The Control 12 starts automatically after being connected to a power supply.
  • Note: In the delivery state, the panel automatically logs on with the user name Control 12 without a password.
  • After the Login, additional users can be added at any time or further settings may be changed in the Windows Settings.

Switching On

  • Remove the glass cover: To do so, use both hands to take the glass cover on both sides and carefully pull the glass cover away from the panel towards yourself (magnetic mount).
  • The On/Off button is now accessible.
  • Press the On/Off button to switch on. The operating system will boot.

Switching Off

  • Tap the Windows logo on the Windows Start screen, select the On/Off icon, and select the option “Shut down”.
  • Note: You will find more detailed information on touch and keyboard input in the manual.

Software

  • The panel can be operated both with the supplied YOUVI software and with other Windows-compatible software.
  • Tip: After commissioning and setting up the panel, we recommend that you create a backup using the optionally available recovery stick from PEAKnx.

Operating system

  • The operating system used is Microsoft Windows 10 IoT Enterprise. Other drivers and programs for the visualization of building information and building control can be installed later.
  • Note: PEAKnx provides no service and no warranty for software products from other companies and in case of OS driver updates.

YOUVI Software package

  • The YOUVI Basic visualization software included in the scope of delivery is used to control KNX devices such as sockets, switches, lights, dimmers, RGB lights, heaters, blinds, or shutters.
  • Thanks to the IP router included in the software package, the panel can run YOUVI‘s visualize-on without an external server or additional bus coupler.
  • Only the connection to the IP network and the KNX bus (via the integrated KNX connection on the panel) is necessary.

Setting up the visualization

  • After commissioning, set up the visualization as described in the enclosed quick start quide. It is assumed that all KNX actuators have already been parameterized via the ETS.

Technical support

  • If you experience problems with your Control 12, please contact our PEAKnx Support Team:
  • Mail:[email protected]
  • Create a Support Ticket: https://helpdesk.peaknx.com/
  • Phone: +49-6151-279 1825
  • www.peaknx.com
  • The product names mentioned in this document may be brands or registered trademarks of their respective owners.
  • These are not explicitly labeled with “™” or “®”.
  • © PEAKnx GmbH
  • Otto-Röhm-Strasse 69
  • 64293 Darmstadt
  • Germany
  • www.peaknx.com
  • [email protected]
  • Document version: 3.0.0
  • Date: 06.12.23

Documents / Resources

| PEAKNX PNX12-20001 Control 12 Getting Started [pdf] User Guide
PNX12-20001 Control 12 Getting Started, PNX12-20001, Control 12 Getting Started, Getting Started, Started
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PEAKnx User Manuals

Related Manuals