ikan LWX20 Lyra Daylight Studio Light with DMX Control User Guide
- June 9, 2024
- ikan
Table of Contents
- ikan LWX20 Lyra Daylight Studio Light with DMX Control
- Product Information
- Safety Instructions
- Product Usage Instructions
- What’s Included
- General Information
- Product Safety Instructions
- General Guidelines
- Fixture Overview
- Cleaning & Maintenance
- Specifications
- Photometrics
- Optional Accessories
- CONDITIONS OF WARRANTY SERVICE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ikan LWX20 Lyra Daylight Studio Light with DMX Control
Product Information
The Ikan Lyra Bi-Color DMX LED Light is a high-quality studio light fixture designed to offer reliable performance for years when used according to the guidelines in the user manual. It comes with a power supply, yoke mount, power cord, and a Lyra Studio Light Fixture. The fixture has been throughly tested to ensure it is of optimal quality and free of any defects that may cause damage or safety concerns.
Safety Instructions
As an electronic device, it is important to follow the guidelines in the manual to guarantee a smooth operation and prevent any potential hazards. Here are some safety instructions:
- This device falls under PROTECTION CLASS 1, so it must be grounded properly.
- Only qualified personnel should perform all electrical connections.
- Indoor use only! Do not expose to rain and/or moisture.
- Do not plug the fixture into a dimmer pack.
- Never look directly into the light source of this fixture to prevent injury to your retina that may induce blindness.
- Always disconnect from the main power source before performing any type of service and/or cleaning procedure.
- Only handle the power supply by the plug end and never pull out the plug by tugging the wire portion of the cord.
Product Usage Instructions
Here are some guidelines on using this product:
- Carefully inspect the shipping carton for damage that may have occurred during shipping. If you find damage or missing parts, contact the customer support team for further instructions.
- Follow the installation guidelines described in the manual. Only qualified and certified personnel should perform the installation of this fixture.
- Use only the original rigging parts (yoke) included with this fixture during installation. Any modifications will void the original manufacturer’s warranty and increase the risk of damage and/or personal injury.
- Connect the power supply to the power source and then to the fixture.
- Turn on the light by pressing the power button.
- Adjust the brightness and color temperature accordingly using the control panel and DMX control.
- When finished, turn off the light and disconnect it from the power source.
By following these guidelines, you can enjoy the benefits of this high-quality studio light fixture while ensuring safety and reliability.
What’s Included
- 1 x Lyra Studio Light Fixture
- 1 x Power supply
- 1 x Yoke Mount
- 1 x Power Cord
General Information
Thank you for buying the Ikan Lyra Bi-Color DMX LED Lights. This fixture has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance.
Every fixture has been throughly tested. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact. In the event damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not discard the shipping carton in the trash. Please recycle whenever possible
Product Safety Instructions
This fixture is an extremely sophisticated piece of electronic equipment. To
guarantee a smooth operation, it is important to follow the guidelines in this
manual. The manufacturer of this device will not accept responsibility for
damages resulting from the misuse of this fixture due to the disregard of the
information printed in this manual.
This device falls under PROTECTION CLASS 1. It’s essential this device be
grounded properly. Only qualified personnel should perform all electrical
connections.
INDOOR USE ONLY!
DO NOT EXPOSE TO RAIN AND/OR MOISTURE!
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
For proper operation, follow the Installation guidelines described in this
manual. Only qualified and certified personnel should perform installation of
this fixture and only the original rigging parts (yoke) included with this
fixture should be used for installation. Any modifications will void the
original manufacturer’s warranty and increase the risk of damage and/or
personal injury.
Never look directly into the light source of this fixture to prevent risk of
injury to your retina, which may induce blindness.
Always disconnect from main power source before performing any type of service
and/or cleaning procedure. Only handle the power supply by the plug end, never
pull out the plug by tugging the wire portion of the cord.
Do not operate this fixture if the power cord has become frayed, crimped and/or damaged. If the power cord is damaged, replace it immediately with a new one of similar power rating
General Guidelines
NEVER OPEN THIS FIXTURE WHEN IN USE!
Please make sure there are NO FLAMMABLE MATERIALS close to the fixture while
operating, to prevent any fire hazard.
The fixture must be installed in a location with adequate ventilation, at least 1.5 feet (.5m) from adjacent surfaces. Be sure no air ventilation slots are blocked.
- DO NOT attempt installation and/or operation without knowledge of how to do so.
- DO NOT permit operation by persons who are not qualified to operate this type of fixture. Most damages are the result of operations by nonprofessionals. Consistent operational breaks may ensure the fixture will function properly for many years to come.
- DO NOT shake fixture and avoid using brute force when installing and/or operating the fixture.
- Always install the fixture with an appropriate safety cable. When installing the fixture in a suspended environment, always use correct mounting hardware that can be inserted into the Baby 1/8 in. or Junior 1-1/8 combo pin adapter.
- Use the original packaging and materials to transport the fixture in for service.
Fixture Overview
Fixture Menu
-
ON-BOARD SYSTEM MENU
The fixture comes with an easy-to-navigate system menu. The next section will detail the functions of each command in the system menu. -
LCD MENU CONTROL KNOB
The control knob allows for local control as well as control from DMX board. The local control gives the user adjustment from 10%-100% in brightness. The user can also adjust the DMX channels 1 thru 512 by pressing down on the large yellow dial. -
DMX Channel
The DMX512 channel selection can be made from the back of the fixture using the large yellow knob to dial in the correct DMX number. When a DMX signal is detected on the fixture, all other controls are closed down and only DMX channel control can be selected on the rear of the fixture.
Depending on DMX channel selected the light will require one channel for use on the DMX board. For example if set to channel 5, channel 5 will control the brightness.
Cleaning & Maintenance
CAUTION! Disconnect power before cleaning or maintenance.
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light
output, and extended life. The frequency of cleaning depends on the
environment in which the fixture operates: damp, smoky, or particularly dirty
environments can cause greater accumulation of dirt on the fixture.
Never use alcohol, solvents, or ammonia-based cleaners
MAINTENANCE
Regular inspections are recommended to insure proper function and extended
life. There are no user-serviceable parts inside this fixture. Please refer
all other service issues to an authorized ikan service technician. Should you
need any spare parts, please order genuine parts from your local ikan dealer.
Please refer to the following points during routine inspections:
Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall.
Check for any deformations on the housing, rigging hardware and rigging points (ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter into the fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person(s). Electric power supplies and cables must not show any damage or fraying. Never remove the ground prong from the power cable.
Cooling System
When the fan switch on the back of the light is switched to OFF the light will
be in passive cooling mode. In this mode the light will only go to a max of
80% brightness. When the fan switch is to ON the light will be in active
cooling mode, which enables the light to be used at 100% brightness.
Specifications
Head Type | Daylight 5600K |
---|---|
Lens | ½ Stop Soft Diffusion |
Beam Angle | 110° |
Control/Dimming | DMX & Local Knob Control |
Build Material | Metal & Plastic Shell |
Cooling System | Fan Off: Passive Fan On: Active |
Yoke | Baby 5/8” – Junion 1-1/8” Combo Pin |
Fixture Size | 20 x 5 x 29” |
Fixture Weight | 18 lbs |
Power Supply | Input: 100-220VAC |
Output: 27.2VDC
Fixture Power Consumption| 205 Watts
Photometrics
DISTANCE | FC | LUX | BEAM SPREAD |
---|---|---|---|
5ft. / 1.5m | 240 | 2585 | 12ft. / 3.6m |
10ft. / 3m | 64 | 687 | * |
15ft. / 4.5m | 30 | 323 | * |
beam spread may be too large to measure at a certain distance
Optional Accessories
Some other products that work well with the Lyra Lights available from Ikan include:
- KCP-703 Stage Clamp with 16mm Stud
- ROLLR-STND10 2-Stage Roller Stand 10 ft 6 in
- SW-04 Safety Wire
- IDX-096 96 Channel DMX Console
Learn More
More dynamic information at official website:
www.ikancorp.com
Support
Contact email: support@ikancorp.com
CONDITIONS OF WARRANTY SERVICE
- Free service for one year from the day of purchase if the problem is caused by manufacturing errors.
- The components and maintenance service fee will be charged if the warranty period is expired.
Free Service will not be Provided in the Following Situations:
(Even if the product is still within the warranty period.)
- Damage caused by abuse or misuse, dismantling, or changes to the product not made by the company.
- Damage caused by natural disaster, abnormal voltage, and environmental factors, etc.
©2022 Ikan International. All rights reserved.
www.ikancorp.com
1.713.272.8822
sales@ikancorp.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>