PHILIPS LL234X CoreLine Trunking Gen2 Ceiling Light User Guide

June 9, 2024
Philips

LL234X Coralline Trucking Gen2 Ceiling Light
User Guide

LL234X Carelines Trucking Gen2 Ceiling Light

442710401344C

GLOW WIRE 850°C
**** Prevent water from entering on or in the illuminate at installation and during use of the luminaire.

Description LED module Final light source class
FO LED STRIP OC 2FT 2250LM 830 BC HV5 C
FO LED STRIP OC 2FT 2250LM 840 BC HV5 C
FO LED STRIP OC 2FT 2250LM 865 BC HV5 C
FO LED STRIP OC 2FT 2200LM 830 BC HV5 D
FO LED STRIP OC 2FT 2200LM 840 BC HV5 D
FO LED STRIP OC 2FT 2200LM 865 BC HV5 D
Luminare type System flux [lm]
L1 [mm]
--- ---
LL212X 30S PSU
53S PSU N/HE 5,300
80S PSU N/HE 8,000
30S PSD/SRD 3,000
53S PSD/SRD N/HE 5,300
80S PSD/SRD N/HE 8,000
45S PSU N/HE 4,500
LL217X 80S PSU
120S PSU N/HE 12,000
45S PSD/SRD 4,500
80S PSD/SRD N/HE 8,000
120S PSD/SRD N/HE 12,000
90S 2xPSU 9,000
160S 2xPSU N/HE 16,000
240S 2xPSU N/HE 24,000
90S 1xPSD/SRD 9,000
90S 2xPSD/SRD 9,000
160S 1xPSD/SRD N/HE 16,000
160S 2xPSD/SRD N/HE 16,000
240S 2xPSD/SRD N/HE 24,000

Installation – all steps

Drawin Accesorries
2a LL200Z MB-SW
2b LL200Z CB
2c LL200Z SMB
2d LL200Z PB
2e LL200Z SMB-TPM SET

Inrush current
* Warning! The values on the left are for 1.5 mm thick cables, the values on the right are for 2.5 mm thick cables
Maintenance instructions
To assure the lighting quality of this unique LED lighting concept there are a few instructions regarding the maintenance of this LED luminaire:

  1. Do not touch electronic components! Electronic components are under high voltage. Electronic components are ESD sensitive.
  2. During installation or when maintaining the luminaire please use static free gloves to avoid marks on the luminaire.
  3. To remove dirt and spots use the following: Dust: only use micro fiber cloths Fingerprints, etc.: use a cleaner for synthetic materials with antistatic properties.
  4. Do not stare into the LED light beam.
  5. To avoid scratches and dirt on optical parts remove protective foil after installation.
  6. The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements.
  7. The light source of this luminaire is not replaceable: when the light source reaches its end of life whole luminaire shall be replaced.
  8. Driver insulation: Basic according to IEC 61847-1.

ATTENTION OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES
Disconnect be for servicing
Luminaire has basic insulation between Low Voltage supply and control conductors.
The light source and/or control gear and/or the external flexible cable contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.

Printed in Poland
Data subject to change without notice
Keep for future reference: www.philips.com/lighting
442710401344
12/ 2022, Signify Holding All rights reserved

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Philips User Manuals

Related Manuals