Anolis Eminere Side 2 0 LED Lighting User Manual
- June 9, 2024
- ANOLiS
Table of Contents
Eminere Side 2 0 LED Lighting
User Manual Eminere Side ® 1/ Eminere Side ® 2
Eminere Side ® 3/ Eminere Side ® 4
Eminere Side 2 0 LED Lighting
QR code for user manual
https://www.anolislighting.com/resource/eminere-side-1234-user- manual
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE POWERING OR INSTALLING YOUR Eminere Side !
Save it for future reference.
This device has left our premises in absolutely perfect condition. In order to
maintain this condition and to ensure safe operation, it is absolutely
necessary for the user to follow the safety instructions and warnings written
in this manual.
The manufacturer will not accept liability for any resulting damages caused by
the non-observance of this manual or any unauthorized modification to the
device.
Unauthorized modification will void warranty.
Safety instructions
DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN
THIS UNIT!
This fixture should be operated only from the type of power source
indicated on the marking label. If you are not sure of the type of power
supplied, consult your authorized distributor or local power company.
Always disconnect the fixture from AC power before cleaning, servicing or
installing.
Make sure the data/power cable is not damaged by sharp edges. Check the
fixture and the power cord from time to time.
Do not install the unit near an open flame.
During operation the housing becomes hot.
Refer servicing to qualified service personnel.
This fixture falls under protection class I. Therefore this fixture has to
be connected to a mains socket outlet with a protective earthing connection.
Do not connect this fixture to a dimmer pack.
LED light emission. Risk of eye injury. Do not look into the beam from a
short distance without suitable protective eyewear. Do not look at LEDs with
magnifiers or similar optical instruments that may concentrate the light
output.
The fixture was designed for outdoor use. This fixture must not be used for
underwater installation.
When choosing the installation spot, please make sure that the fixture is not
exposed to extreme heat or dust.
Avoid using the unit in locations subject to possible impacts.
The fixture body never must be covered with cloth or other materials when the
fixture is under operation.
Only operate the fixture after having checked that the housing is firmly
closed and all screws are tightly fastened.
The fixture becomes hot during operation. Allow the fixture to cool
approximately 30 minutes prior to servicing or maintenance.
Operate the fixture only after having familiarized yourself with its
functions. Do not permit operation by persons not qualified to operate the
fixture. Most damages are the result of unprofessional operation!
Immunity of the equipment is designed for electromagnetic environments E1, E2,
E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility.
Product family standard for audio, video, audiovisual and entertainment
lighting control apparatus for professional use. Part 2: Immunity.
The installation company should check levels of possible interferences above
the tested levels E1,E2,E3 given by this standard (e.g. transmitters in
surrounding area) before installing the equipment.
Emission of the equipment complies with the standard EN55032 Electromagnetic
compatibility of multimedia equipment – Emission Requirements according to
class B.
Please consider that unauthorized modifications on the fixture are forbidden
due to safety reasons!
Please use the original packaging if the fixture is to be transported.
If this device will be operated in any way different to the one described in
this manual, the product may suffer damages and the warranty becomes void.
Furthermore, any other operation may lead to dangers like short-circuit,
burns, electric shock etc.
Fixture exterior view
- Transparent glass cover
- LED module
- Input connector
- Output connector
- Mounting brackets
- Aluminium base
Installation
3.1 Mounting the fixture
The Eminere Side can be arranged in any orientation on a flat, non-flammable
surface by means of two mounting brackets (5), the LED module (2) can be
tilted 120° to adjust desired beam position.
Ensure that the structure to which you are attaching the unit is secure.
3.2 Connection to mains
The unit must be installed by a qualified electrician in accordance with
all national and local electrical and construction codes and regulations.
This device falls under class one and must be grounded!
The Eminere Side is equipped with auto-switching power supply that
automatically adjusts to any 50-60Hz AC power source from 120-277 Volts.
Wiring of input/output connectors:
Input – panel connector (front view) | Output – panel connector (front view) |
---|---|
Fixture´s Amphenol connectors are dust and water protected according to IP 67
by mating with related Amphenol connectors.
They cannot stay disconnected outdoor.
The output panel connector at last fixture in the Eminere Side chain has to
always be covered with the watertight cap to keep declared IP rating.
The Eminere modules should be connected to the E-box which allows power supply
of the Eminere modules and their control.
Do not connect (disconnect) Eminere Sides to the E-box or Booster box and
each other when they are under voltage!
When you change any setting of the E-box, disconnect the E-box from power
and connect it to power again to activate changes which you have made.
Examples of connection for various versions of the E-box.
Please read the E-box user manual for more information about its setting and
connection to Eminere modules.
Needed cables are stated in the chapter “Technical information“.
E-box Daisy
E-box Star
E-box Pro
E-box Lite
Number of connected Emineres Side to one E-box output depends on a cable
length, power voltage, type of and E-box.
The tables below state max. theoretical number of Emineres connected to the
one LED output of the E-box without Booster boxes. The following tables apply
for the Standard mode of E-boxes
EMINERE SIDE 1 | Voltage |
---|---|
**Cable length *** | 120V |
10 m | 83 |
20 m | 83 |
30 m | 58 |
50 m | 35 |
70 m | 25 |
100 m | 17 |
200 m | 9 |
EMINERE SIDE 2 | Voltage |
--- | --- |
**Cable length *** | 120V |
10 m | 41 |
20 m | 41 |
30 m | 28 |
50 m | 17 |
70 m | 12 |
100 m | 9 |
200 m | 4 |
EMINERE SIDE 3 | Voltage |
--- | --- |
**Cable length *** | 120V |
10 m | 28 |
20 m | 28 |
30 m | 19 |
50 m | 12 |
70 m | 8 |
100 m | 6 |
200 m | 3 |
EMINERE SIDE 4 | Voltage |
--- | --- |
**Cable length *** | 120V |
10 m | 21 |
20 m | 21 |
30 m | 15 |
50 m | 9 |
70 m | 6 |
100 m | 4 |
200 m | 2 |
- Cable length is a total cable length between E-box and last connected Eminere Side. Example: Total cable length=L1+L2+L3
Notice for the E-box Star: The tables above state max. total number of
Emineres Side connected to 6 LED outputs of the E-box Star (or max. number of
Emineres Side connected to one output if the rest of outputs is not
connected). The E-box Star has only one power input!
The table below states max. number of Emineres Side connected to the one LED
output of the E-box using Booster boxes (which compensate a voltage drop)
regardless voltage and cable length.
3.3 The Booster box
To compensate a voltage drop in large installation, the Booster boxes have to
be connected in the chain of Emineres Side at every LED output of the E-box.
The following tables give numbers of Emineres Side after which the Booster box
has to be installed in the chain of Emineres Side (at one LED output of the
E-box). The following tables apply for the Standard mode of E-boxes.
EMINERE
SIDE 1| Max. number of Emineres 1= 191
---|---
| Voltage
Cable length| 120V| 190V| 230V| 277V
10 m| 83,166| 131| 159| –
20 m| 83,166| 131| 159| –
30 m| 58,116,174| 131| 159| –
50 m| 35,70,105,140,175| 88,176| 128| 186
70 m| 25,50,75,100,125,150,175| ########| 92,184| 133
100 m| 17,34,51,68,85,102,119,136,153,170,187| 44,88,132,176| 64,128| 93,186
200 m|
9,18,27,36,45,54,60,72,81,90,99,108,117,126,135,144,153,162,171,180,189,|
22,44,66,88,110,132,154,176| 32,64,96,128,160| 47,94,141,188
EMINERE
SIDE 2| Max. number of Emineres 2= 94
---|---
| Voltage
Cable length| 120V| 190V| 230V| 277V
10 m| 41,82| 64| 78| –
20 m| 41,82| 64| 78| –
30 m| 28,56,84| 64| 78| –
50 m| 17,34,51,68,85| 43,86| 63| 91
70 m| 12,24,36,48,60,72,84| 31,62,93| 45,90| 65
100 m| 9,18,27,36,45,54,60,72,81,90| 21,42,63,84| 31,62,93| 46,92
200 m| 4,8,12,16,20,24,28,32,3640,44,48,52,56,60,64,68,7276,80,84,88,92|
11,22,33,44,55,66,77,88| 16,32,48,64,80| 23,46,69,92
EMINERE
SIDE 3| Max. number of Emineres 3= 64
---|---
| Voltage
Cable length| 120V| 190V| 230V| 277V
10 m| 28,56| 44| 53| –
20 m| 28,56| 44| 53| –
30 m| 19,38,57| 44| 53| –
50 m| 12,24,36,48,60| 29,58| 43| 62
70 m| 8,16,24,32,40,48,56| 21,42,63| 31.62| 44
100 m| 6,12,18,24,30,36,42,48,54,60| 15,30,45,60| 21,42,63| 31,62
200 m| 3,6,9,12,15,18,21,24,27,30,33,36,39,42,45,48,51,54,57,60,63|
7,14,21,28,35,42,49,56,63| 11,22,33,44,55| 16,32,48,
EMINERE
SIDE 4| Max. number of Emineres 4= 48
---|---
| Voltage
Cable length| 120V| 190V| 230V| 277V
10 m| 21,42| 33| 40| –
20 m| 21,42| 33| 40| –
30 m| 15,30,45| 33| 40| –
50 m| 9,18,27,36,45| 22,44| 32| 47
70 m| 6,12,18,24,30,36,42| 16,32| 23,46| 38
100 m| 4,8,12,16,20,24,28,32,36,40,44| 11,22,33,44| 16,32| 23,46
200 m| 2,4,6,8,10,12,14,16,18,20,22.24.26,28,30,32,34,36,38,40,42,44,46|
5,10,15,20,25,30,35,40,45| 8,16,24,32,40| 12,24,36
Example: E-box Daisy, Power supply= 230V, Cable length=70m,
fixture=Eminere Side 2
The Booster box has to be connected after every 45th Eminere Side 2 (fixture
45 and fixture 90) from 94 fixtures.
3.4 The Booster box installation
ALWAYS DISCONNECT THE EMINERES SIDE FROM MAINS BEFORE CONNECTING/DISCONNECTING
THE BOOSTER BOX.
The Booster box falls under protection class I. Therefore, every Booster
box has to be connected to a mains socket outlet with a protective earthing
connection.
- Unscrew the four screws (1) from the cover (2) on the Booster box to get access to the terminal block (3) and two mounting holes of diameter of 4.6 mm (4).
- Screw the Booster box on a non-flammable flat surface and connect cables.The Cable gland M20x1.5 for Power IN (5) is intended for a cable of a diameter of 7-13mm.
Remove the end cap from the cable gland before passing the cable.
Power connection**| L| N| ****(earth)**
---|---|---|---
Core (EU)| Braun| Blue| Green/yellow
Core (US)| Black| White| Green
We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the gland body.
- Screw the cover (2) back on the Booster box.
3.5 Jumper cable assembling
-
Dismantle the connector and slide its parts onto the cable (6).
Use the seal with inner diameter of 14.5 mm for the Anolis cable (P/N 13053138 or P/N 13053139).
The seal with inner diameter of 14.5 mm serves for cable of diameter 10-14.5mm.
The seal with inner diameter of 10 mm serves for cable of diameter 8-10mm. -
Put the sealing circle (2) on the connector with screws (1).
-
Remove insulation from the cable (6) and from individual wires and fasten three terminals on data wires.
CE version US version -
Put parts of the connector on the cable (6) and connect wires to the connector. First connect power wires (L,N, Earth) and after that data wires (D+, D-, 0V). Avoid excessive torsion of data wires!
-
After connecting wires to the connector, tighten the three data wires (D+,D-, 0V) by means of the cable binder (7).
-
Screw the clamp ring (3) to the connector (1), insert the seal (4) to the clamp ring (3) and tighten the sealing nut (5) enough. During the steps DO NOT TWIST the cable (6).
-
Use the same procedure to assemble the connector on the second end of the cable.
IMPORTANT
Do not bend the cable near to the connector, minimum distance for bending is 50mm.
Software update
Software update of Eminere has to be done by means of the software ROBE
Uploaded running on PC.
The ROBE Uploaded is a software for automatized software update of ROBE
fixtures. The ROBE Uploaded switches Emineres to the update mode
automatically.
Please see https://www.robe.cz/robe-uploader/ for more information.
DMX or Ethernet connection via E-box
If the option Standard is selected from the menu E-box mode and LED modules
are connected in series, the E-box will be updated including connected Eminere
modules. You have to use the file EminereEbox.lib in
the ROBE Uploader for this operating mode.
If the option Pass-Thr is selected from the menu E-box mode and LED modules
are connected in series, you have to do the following steps to update Emineres
including the E-box:
- Set the E-box to the Standard mode and switch it off/on. Only E-box will be shown in the ROBE Uploaded. You have to use the file EminereEbox.lib in the ROBE Uploaded for software update of the E-box and connected LED modules.
- After updating, set the E-box to the Pass-Thorough mode and switch it off/on.
For more information about updating please see the E-box Lite/Daisy/Star user manual.
Technical specifications
Power supply
-
Electronic auto-ranging
-
Input voltage: 120 – 277V AC, 50-60 Hz
-
Power consumption:
Eminere Side 1: 25W
Eminere Side 2: 45W
Eminere Side 3: 65W
Eminere Side 4: 85W -
Inrush current:
Eminere Side 1: <70A/250µs
Eminere Side 2: <70A/250µs
Eminere Side 3: <100A/200µs
Eminere Side 4: <100A/200µs
Optic
-
Light source:
Eminere Side 1: 12 x high power LEDs
Eminere Side 2: 24 x high power LEDs
Eminere Side 3: 36 x high power LEDs
Eminere Side 4: 48 x high power LEDs -
Colour variants: RGBW, RGBA, single colour
-
Beam Angle:
Symmetric: 9°, 15°, 30°, 50°, 65°, 100°
Bi-symetrical: 10° x 30°, 30° x 10°, 10° x 60°, 60° x 10°, 35° x 70°, 70° x 35°, 15° x 90°, 90° x 15° Wall washer, Wide Wall washer -
Projected Lumen Maintenance: L90B10 >90.000 hrs, Ta = 25°C / 77°F
Compatible drivers
-
E-box Daisy
1 Output
1 Main power Input
Control: DMX, Art-Net, SACN , W-DMX control, RDM Pixel control (1px= 1ft)
120-277 V Input
Connection via terminal blocks, inlets via grommet IP67 -
E-box Star
6 outputs
1 Main power Input
Control: DMX, Art-Net, sACN , W-DMX control, RDM Pixel control (1px= 1ft)
120-277 V Input
Connection via terminal blocks, inlets via grommet IP67 -
E-box Pro
6 outputs
6 Main power Inputs
Control: DMX, Art-Net, SACN , W-DMX control, RDM Pixel control (1px= 1ft)
120-277 V Input
Connection via terminal blocks, inlets via grommet IP67 -
E-box Lite
1 output
1 Main power Input
Control: DMX, W-DMX control, RDM Pixel control (1px= 1ft)
120-277 V Input
Connection via screw terminal blocks, inlets via grommet IP67
Protection factor
- CE: IP 67
- US: Suitable for wet location
Impact rating
- CE: IK06
Operating ambient temperature range
- -20°C /+40°C (-4°F /+104°F)
Operating temperature
- +67°C @ Ambient +40°C (+153°F @ Ambient +104°F)
Connection
- Input: panel connector Amphenol ABAB-DMQ06000021-IN (P/N13052952)
- Output: panel connector Amphenol ABAB-DAQ06000021 (P/N13052953) + water-tight cap
Mounting method
- Via two L-shape brackets
- LED module “tilt” adjustment range: -105°/+15°
Sizes
- Eminere Side 1 (300 mm / 1ft)
- Eminere Side 2 (600 mm / 2ft)
- Eminere Side 3 (900 mm / 3ft)
- Eminere Side 4 (1200 mm / 4ft)
Housing
- Aluminium extruded body with diecasted end caps
- Tempered glass
Cooling system
- Convection
Total heat dissipation
- Eminere Side 1: 61 BTU/h (calculated)
- Eminere Side 2: 130 BTU/h (calculated)
- Eminere Side 3: 177 BTU/h (calculated)
- Eminere Side 4: 228 BTU/h (calculated
Weight
- Eminere Side 1: 2.95 kg (6.5 lbs)
- Eminere Side 2: 4.75 kg (10.47 lbs)
- Eminere Side 3: 7.0 kg (15.43 lbs)
- Eminere Side 4: 8.92 kg (19.67 lbs)
Dimensions (All dimensions in mm [inch])
- Eminere Side 1
- Eminere Side 2
- Eminere Side 3
- Eminere Side 4
- Booster box
Included items
- 1 x Eminere Side
- 1 x User manual
Optional accessories
CE Leader Cables FF:
- Leader Cable FF 2m (P/N 13053005)
- Leader Cable FF 5m (P/N 13053006)
- Leader Cable FF 10m (P/N 13053007)
- Leader Cable FF 25m (P/N 13053008)
- Leader Cable FF 50m (P/N 13053009)
US Leader Cables FF:
- Leader Cable FF 2m (P/N 13053010)
- Leader Cable FF 5m (P/N 13053011)
- Leader Cable FF 10m (P/N 13053012)
- Leader Cable FF 25m (P/N 13053013)
- Leader Cable FF 50m (P/N 13053014)
Jumper Cables FF/FM:
- Jumper Cable FF/FM 0,25m (P/N 13053052)
- Jumper Cable FF/FM 0,5m (P/N 13053053)
- Jumper Cable FF/FM 1m (P/N 13053054)
- Jumper Cable FF/FM 2m (P/N 13053055)
- Jumper Cable FF/FM 3m (P/N 13053056)
- Jumper Cable FF/FM 5m (P/N 13053057)
- Jumper Cable FF/FM 10m (P/N 13053058)
Waterproof Cover Cap FM ZAHB-0006 (P/N 17031173)
Field Installable Connector FF (P/N 13053003)
Field Installable Connector FM (P/N 13053004)
E-boxes:
- E-box Daisy (P/N 10063655)
- E-box Daisy/W (P/N 10063638)
- E-box Lite (P/N 10063657)
- E-box Lite/W (P/N 10063653)
- E-box Star (P/N 10063656)
- E-box Star/W (P/N 10063644)
Booster box (P/N 10063712)
- Shield for Eminere 1 RAL9011 (P/N 10980488)
- Shield for Eminere 2 RAL9011 (P/N 10980489)
- Shield for Eminere 3 RAL9011 (P/N 10980490)
- Shield for Eminere 4 RAL9011 (P/N 10980491)
Cleaning and maintenance
DANGER !
Disconnect from the mains before starting any maintenance or cleaning
work
Rinse off loose dirt with low pressure water spray. Wash the housing with a
soft brush or sponge and a mild, nonabrasive washing detergent. Rinse it.
Maintenance and service operations are only to be carried out by a qualified
person.
Should you need any spare parts, please use ROBE OEM parts.
6.1 Disposing of the product
To preserve the environment please dispose or recycle this product at the end
of its life according to the local regulations and codes.
Change Log
This section summarizes changes in the user manual.
Version of the manual | Date of issue | Description of changes |
---|---|---|
1.1 | 10/07/2020 | Voltage range changed |
1.2 | 23/07/2021 | Optional accessories changed |
1.3 | 19/08/2021 | Jumber cables changed in Optional accessories |
1.4 | 19/10/2021 | Technical specifications changed |
1.5 | 26/11/2021 | Optional accessories changed |
1.6 | 20/12/2021 | Jumper cable mounting added |
1.7 | 06/01/2022 | Jumper cable mounting changed |
1.8 | 23/02/2022 | Sealing circle added to jumper cable mounting |
1.9 | 19/05/2022 | QR code added |
2.0 | 10/01/2023 | Software update description |
Specifications are subject to change without notice.
January 10, 2023
Copyright © 2019-2023 Robe Lighting – All rights reserved
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701
Valasske Mezirici
DMX protocol
Eminere 1/2/3/4 and Eminere Side 1/2/3/4 – DMX protocol
Eminere In ground 2/4 – DMX protocol
Eminere Remote 1/2/3/4 – DMX protocol
Version: 3.1 (23 modes in total), software version 3.0 and higher|
Mode/Channels in all| Mode 1: RGBW(A)-8bit, Mode 2: RGB 8-bit, Mode 3:
full RGBW(A)|
1| 2| 3| 4| 5| 6| 7-10| Mode 4: White-
full control, Mode 5: Reduced RGBW(A)|
4| 3| 12| 3| 6| 8| Reserved| Mode 6- Reduced RGBW(A)+white control|
| | | | | | | RGBW(A) / RGB modes|
Mode/channels| DMX Value| Function| Type of control
1| 2| 3| 4| 5| 6
1| 1| 1| –| 1| 1| | Red|
| | | | | | 0 – 255| Red LEDs saturation control (0-100%)| proportional
–| –| 2| –| –| –| | Red Fine|
| | | | | | 0 – 255| Red LEDs saturation control fine| proportional
2| 2| 3| –| 2| 2| | Green|
| | | | | | 0 – 255| Green LEDs saturation control (0-100%)| proportional
–| –| 4| –| –| –| | Green Fine|
| | | | | | 0 – 255| Green LEDs saturation control fine| proportional
3| 3| 5| –| 3| 3| | Blue|
| | | | | | 0 – 255| Blue LEDs saturation control (0-100%)| proportional
–| –| 6| –| –| –| | Blue Fine|
| | | | | | 0 – 255| Blue LEDs saturation control fine| proportional
4| –| 7| –| 4| 4| | White (Amber)|
| | | | | | 0 – 255| White LEDs saturation control (0-100%)| proportional
–| –| 8| –| –| –| | White (Amber) Fine|
| | | | | | 0 – 255| White LEDs saturation control fine| proportional
–| –| 9| 1| –| 5| | Green correction|
| | | | | | 0| Uncorrected white| step
| | | | | | 1-127| Minus green –> uncorrected white| proportional
| | | | | | 128| Uncorrected white (128=default)| step
| | | | | | 129-255| Uncorrected white –> Plus green| proportional
–| –| 10| 2| –| 6| | Colour temperature
correction (CTC)|
| | | | | | 0| No function (0 – default)| step
| | | | | | 1 – 10| Tungsten dimming 2700 K| step
| | | | | | 11 – 20| Tungsten dimming 3200 K| step
| | | | | | 21-255| Colour temperature changing from 1800 K –> 6500 K|
proportional
| | | | | | | (21-1800K, 66-2700K, 91-3200K,141-4200K, 211-5600K, 255- 6500K)|
–| –| 11| 3| 5| 7| | Dimmer|
| | | | | | 0 – 255| Light intensity coarse (0-100%)| proportional
–| –| 12| –| 6| 8| | Dimmer Fine|
| | | | | | 0 – 255| Light intensity fine| proportional
| | | | | | | |
Copyright © 2022 Robe Lighting s.r.o. – All rights reserved|
All Specifications subject to change without notice|
| | | | | | | |
Eminere 1/2/3/4 and Eminere Side 1/2/3/4 – DMX protocol
Eminere Inground 2/4 – DMX protocol
Eminere Remote 1/2/3/4 – DMX protocol
Version: 3.1 (23 modes in total)| | |
Mode/Channels in all| Mode 11: TW – White selection + Dimmer, Mode 12:
TW – WW + CW|
11| 12| 13| 14-16| Mode 13: PW – Dimmer|
3| 4| 2| Reserved| |
| | | | TW and PW modes|
Mode/channels| DMX Value| Function| Type of control
11| 12| 13
1| –| –| | White colour selection|
| | | 0 – 255| White from 2700 K – 6500 K| proportional
–| 1| –| | Warm White|
| | | 0 – 255| Warm White LEDs saturation control (0-100%)| proportional
–| 2| –| | Cool White|
| | | 0 – 255| Cool White LEDs saturation control (0-100%)| proportional
2| 3| 1| | Dimmer|
| | | 0 – 255| Light intensity coarse (0 – 100%)| proportional
3| 4| 2| | Dimmer Fine|
| | | 0 – 255| Light intensity fine| proportional
| | | | |
Copyright © 2022 Robe Lighting s.r.o. – All rights reserved|
All Specifications subject to change without notice|
| | | | |
Eminere 1/2/3/4 and Eminere Side 1/2/3/4 – DMX protocol
Eminere Inground 2/4 – DMX protocol
Eminere Remote 1/2/3/4 – DMX protocol
Version: 3.1 (23 modes in total)| | |
Mode/Channels in all| Mode 16: RGBW(A) pixels, Mode 17 RGB pixels,
Mode 18: TW pixels,
17| 18| 19| 20| 21-23| Mode 19- PW dimmer
pixels|
16| 12| 8| 8| Reserved| |
| | | | | Pixel modes|
Mode/channels| DMX Value| Function| Type of
control
17| 18| 19| 20
1| 1| –| –| | Red 1 -Eminere 1/2/3/4|
| | | | 0 – 255| Red LEDs saturation control (0-100%)| proportional
2| 2| –| –| | Green 1-Eminere 1/2/3/4|
| | | | 0 – 255| Green LEDs saturation control (0-100%)| proportional
3| 3| –| –| | Blue 1-Eminere 1/2/3/4|
| | | | 0 – 255| Blue LEDs saturation control (0-100%)| proportional
4| –| –| –| | White (Amber) 1-Eminere 1/2/3/4|
| | | | 0 – 255| White LEDs saturation control (0-100%)| proportional
5| 4| –| –| | Red 2 -Eminere 2/3/4|
| | | | 0 – 255| Red LEDs saturation control (0-100%)| proportional
6| 5| –| –| | Green 2-Eminere 2/3/4|
| | | | 0 – 255| Green LEDs saturation control (0-100%)| proportional
7| 6| –| –| | Blue 2-Eminere 2/3/4|
| | | | 0 – 255| Red LEDs saturation control (0-100%)| proportional
8| –| –| –| | White (Amber) 2-Eminere 2/3/4|
| | | | 0 – 255| White LEDs saturation control (0-100%)| proportional
9| 7| –| –| | Red 3-Eminere 3/4|
| | | | 0 – 255| Red LEDs saturation control (0-100%)| proportional
10| 8| –| –| | Green 3-Eminere 3/4|
| | | | 0 – 255| Green LEDs saturation control (0-100%)| proportional
11| 9| –| –| | Blue 3-Eminere 3/4|
| | | | 0 – 255| Blue LEDs saturation control (0-100%)| proportional
12| –| –| –| | White (Amber) 3-Eminere 3/4|
| | | | 0 – 255| White LEDs saturation control (0-100%)| proportional
13| 10| –| –| | Red 4-Eminere 4|
| | | | 0 – 255| Red LEDs saturation control (0-100%)| proportional
14| 11| –| –| | Green 4-Eminere 4|
| | | | 0 – 255| Green LEDs saturation control (0-100%)| proportional
15| 12| –| –| | Blue 4-Eminere 4|
| | | | 0 – 255| Blue LEDs saturation control (0-100%)| proportional
16| –| –| –| | White (Amber) 4 -Eminere 4|
| | | | 0 – 255| White LEDs saturation control (0-100%)| proportional
–| –| 1| –| | Warm White 1 -Eminere 1/2/3/4|
| | | | | Warm White LEDs saturation control (0-100%)| proportional
–| –| 2| –| | Cool White 1-Eminere 1/2/3/4|
| | | | 0 – 255| Cool White LEDs saturation control (0-100%)| proportional
–| –| 3| –| | Warm White 2-Eminere 2/3/4|
Mode/channels| DMX Value| Function| Type of
control
---|---|---|---
17| 18| 19| 20
| | | | 0 – 255| Warm White LEDs saturation control (0-100%)| proportional
–| –| 4| –| | Cool White 2-Eminere 2/3/4|
| | | | 0 – 255| Cool White LEDs saturation control (0-100%)| proportional
–| –| 5| –| | Warm White 3-Eminere 3/4|
| | | | 0 – 255| Warm White LEDs saturation control (0-100%)| proportional
–| –| 6| –| | Cool White 3-Eminere 3/4|
| | | | 0 – 255| Cool White LEDs saturation control (0-100%)| proportional
–| –| 7| –| | Warm White 4 -Eminere 4|
| | | | 0 – 255| Warm White LEDs saturation control (0-100%)| proportional
–| –| 8| –| | Cool White 4 -Eminere 4|
| | | | 0 – 255| Cool White LEDs saturation control (0-100%)| proportional
–| –| –| 1| | Dimmer 1|
| | | | 0 – 255| Light intensity coarse (0 – 100%)| proportional
–| –| –| 2| | Dimmer Fine 1|
| | | | 0 – 255| Light intensity fine| proportional
–| –| –| 3| | Dimmer 2|
| | | | 0 – 255| Light intensity coarse (0 – 100%)| proportional
–| –| –| 4| | Dimmer Fine 2|
| | | | 0 – 255| Light intensity fine| proportional
–| –| –| 5| | Dimmer 3|
| | | | 0 – 255| Light intensity coarse (0 – 100%)| proportional
–| –| –| 6| | Dimmer Fine 3|
| | | | 0 – 255| Light intensity fine| proportional
–| –| –| 7| | Dimmer 4|
| | | | 0 – 255| Light intensity coarse (0 – 100%)| proportional
–| –| –| 8| | Dimmer Fine 4|
| | | | 0 – 255| Light intensity fine| proportional
| | | | | |
Copyright © 2022 Robe Lighting s.r.o. – All rights reserved|
All Specifications subject to change without notice| |
| | | | | |
Version 2.0
Documents / Resources
|
Anolis Eminere Side 2 0 LED
Lighting
[pdf] User Manual
Eminere Side 2 0 LED Lighting, Eminere Side 2 0, LED Lighting, Lighting
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>