iO HVAC Controls ZP4-ESP 4 Zone Control Panel Owner’s Manual

June 9, 2024
iO HVAC Controls

ESP 4 ZONE PANEL
ZP4-ESP

ZONE CONTROL PANEL

The ZP4-ESP is a 4 zone panel that integrates our award winning ESP technology to completely eliminate the need to install a bypass damper. This 3H/2C zone panel comes with a static pressure sensor. The system works like any standard zone control system with one exception; a static pressure sensor continuously monitors the system static  pressure. If the static pressure goes above setpoint, the ESP panel will power the selected non-calling zone dampers open just enough to relieve the excess pressure. Tests indicate that bleeding a small amount of conditioned air for a short time into non-calling zones has little to no impact on the zone temperature.
The panel can be used with single-stage, multi-stage, heat pump or dual fuel equipment. A wide range of control options provide ultimate application flexibility including adjustable high/low limits, adjustable high/low balance point, and 2 zone, 2nd stage capacity control.

iO HVAC Controls ZP4 ESP 4 Zone Control Panel -

Static pressure sensor & panel cover included
*For ESP functionality, 3-wire MD dampers and static pressure sensor must be used

NO BYPASS REQUIRED!

Features and Benefits:

  • 4 zone universal panel with ESP capability
  • Smallest universal panel offered by iO
  • Up to 2H/2C conventional or 3H/2C heat pump and dual fuel
  • Auto changeover
  • First call priority with time share
  • 2 zone, 2nd stage capacity control
  • Purge cycle option
  • Adjustable high and low limits
  • Adjustable high and low balance points
  • Easy switch configuration
  • Fused protected inputs and outputs

Warranty:

  • 10 Years

Specifications:

Construction Aluminum enclosure with snap-on panel cover
Mounting Snap track with 2 back plate screws
Dimensions 8.75″ Height x 7″ Width x 1.5″ Depth
Operating Temperature -40° F to 150° F
Time Delays 5 minute changeover; 3 minute off on high or low limit 20 minute

time share
Discharge Air Limits| Low Limit (30° F to 55° F); High Limit (100° F to 180° F)

BOARD DIAGRAM

iO HVAC Controls ZP4 ESP 4 Zone Control Panel - BOARD
DIAGRAM

1.   3 AMP FUSE PROTECTS PRINTED CIRCUIT BOARD
2.   24 VOLT TRANSFORMER TERMINALS
3.   ZONE 1 DAMPER TERMINALS
4.   ZONE 2 DAMPER TERMINALS
5.   ZONE 3 DAMPER TERMINALS
6.   ZONE 4 DAMPER TERMINALS
7.   DISCHARGE AIR SENSOR TERMINALS
8.   OUTDOOR TEMPERATURE SENSOR TERMINALS
9.   STATIC PRESSURE SENSOR TERMINALS
10. SPARE 3 AMP FUSES
11. HVAC EQUIPMENT TERMINALS
12. 3 AMP FUSE PROTECTS THE RELAY CONTACTS
13. PANEL POWER LED
14. ZONE DAMPER 1 LED
15. ZONE DAMPER 2 LED
16. ZONE DAMPER 3 LED
17. ZONE DAMPER 4 LED
18. ESP LED
19. HIGH LIMIT POTENTIOMETER
20. LOW LIMIT POTENTIOMETER
21. DISCHARGE AIR SENSOR LED| 22. HIGH BALANCE POINT POTENTIOMETER
23. LOW BALANCE POINT POTENTIOMETER
24. OUTDOOR TEMPERATURE SENSOR LED
25. Y1 RELAY LED
26. Y2 RELAY LED
27. W1/AUX RELAY LED
28. W2/OB RELAY LED
29. G FAN RELAY LED
30. ZONE 1 BYPASS JUMPER
31. ZONE 2 BYPASS JUMPER
32. ZONE 3 BYPASS JUMPER
33. ZONE 4 BYPASS JUMPER
34. ZONE 1 THERMOSTAT TERMINALS
35. ZONE 2 THERMOSTAT TERMINALS
36. ZONE 3 THERMOSTAT TERMINALS
37. ZONE 4 THERMOSTAT TERMINALS
38. TIME DELAY SPEED UP LED
39. TIME DELAY SPEED UP BUTTON
40. SYSTEM CONFIGURATION SELECTOR SWITCHES
41. SYSTEM CONFIGURATION SWITCH DEFINITIONS
---|---

  5351 East Thompson Road Suite 142
Indianapolis, IN 46237
P: 888.359.0362
F:317.489.5204
For Technical
info@iOhvaccontrols.com
www.iOhvaccontrols.com
iO-04-1306-111022

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

iO HVAC Controls User Manuals

Related Manuals