project VC-E2 VC-S3 Record Cleaner Instructions
- June 9, 2024
- PROJECT
Table of Contents
VC-E2 VC-S3 Record Cleaner
Instructions
INSTRUCTIONS FOR USE
Pro-Jest VC-E2
VC-E2 VC-S3 Record Cleaner
Pro-Ject VC-E2
Controls, features and connections
- Vacuum arm* (adhesive velvet strips attached)
- Platter*
- Fixing screw *
- Ventilation outlet
- Main switch with mains power cord socket
- Vacuum on/off switch
- Motor on/off direction switch
- Motor shaft bushing
- Magnetic clamp*
- Cover for ventilation outlet
- Motor shaft
- Vacuum arm flange
- 2x pre-drilled holes for fixing of cover of ventilation outlet
Accessories (included, but not shown above)
- Wash it 2 vinyl cleaning fluid, 100ml bottle*
- Goat hair brush*
- Replacement adhesive strips for vacuum arm*
- AC power cord*
- 2x Washers for setting height of the platter*
Optional accessories (available on request)
- Wash it 2 cleaning fluid bottle sizes: 250ml/500ml/1l
- Goat hair brush
- Adhesive strips for vacuum arm
Dear music lover,
Thank you for purchasing a Pro-Ject Audio Systems record cleaning machine.
In order to achieve maximum performance and reliability, please study these
instructions carefully.
Warning of a hazard for the user, the unit or possible misuse.
Important notice.
During assembly and adjustment small parts can be easily lost if they are not
carefully placed in a suitable receptacle. Before beginning assembly, please
familiarize yourself with the parts listed above which are correspondingly
numbered in the technical diagram. Separately packed items are marked with an
asterisk*.
Safety instructions
This appliance is not to be used by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction.
AC outlet voltages vary from country to country. Before connecting to your
wall outlet, make sure that the voltage in your area meets the voltage
requirements printed on the device.
Hold the end of the plug when unplugging the power cord. Never handle the
power cord while your hands are wet or damp.
Never place any open flame sources, like burning candles, on or near the
device. Do not operate in damp or wet locations, such as near to a bathtub,
sink, swimming pool or any other similar locations.
Keep plastic bags away from children to prevent any risk of suffocation.
Do not cover any ventilation holes (one is located on the left side and others
are on bottom).
During operation this unit will generate loud noises, so we recommend the use
of hearing protectors during longer cleaning sessions. Check the unit after
transportation for signs of damage, if a damage is found, do not operate the
unit and contact your dealer!
The unit is capable of long time running however in such case platter spindle
may get hot and whole platter/clamp area as well as air coming out from the
unit may get warm. The temperature of the platter can´t damage vinyl records.
In order to keep the temperature as low as possible do not expose the unit to
direct sunlight.
Motor should not be turned on when not cleaning your records. Extended running
time outside of the guideline process can cause over-heating.
Setting up the unit
The unit requires a little assembling before use.
- Place cover for ventilation outlet (10) to its position above the outlet (4) and use the supplied screws to fix it into position like shown on the first picture, the holes (13) for the screws are pre-drilled on the top side of the unit.
- Platter assembling – Platter (2) is supplied already assembled together with the motor shaft bushing (8) and fixing screw (3).
Place the 2 pieces of supplied white plastic washers on the motor shaft (11) –
these set the correct height of the platter and then place on top of them the
assembled platter and use the supplied Allen key to tighten the platter on
the shaft.
This product is only for non-commercial use.
Using the unit
Please ensure that all assembly and set up steps have been followed as
outlined in this manual. All 3 rocker switches (“main switch”, “motor” and
“vacuum” should be in position “0”). Connect the power cord to the socket on
the rear side of the VC-E2 and turn the main switch to the “I” position.
Place a record on the platter and put the magnetic clamp on top it.
While the record is turning apply just enough of ready-to-use cleaning fluid
(3ml per side) to the record while holding the brush horizontally and gently
pressing against the record, spread the fluid across the surface of the
record. Use only the necessary amount of fluid, enough to cover the record,
not the machine!
Do not use cleaning fluids from other suppliers. Use only so little fluid that
it is not regularly getting on the surface of the machine. If this happens
remove the excess fluid with a tissue.
Cleaning efficiency can be significantly improved by applying appropriate
force on the cleaning brush. Even more cleaning improvement can be achieved by
using warmed-up Wash It 2 cleaning fluid. Wash It 2 can be warmed in a
microwave oven up to 40 degrees Celsius, please check temperature to avoid
record damage. Wash It 2 is non- flammable and non-toxic. Please note that you
are doing all this at your own risk.
The motor can turn in both directions or can be stopped during the application
of the fluid, depending on your personal preference. To change direction,
choose the “I” position for clockwise rotation or to the “II” position for
counter-clockwise rotation.
It is recommended that you use the brush to spread the Wash it 2 cleaning
fluid on the record in both directions before vacuuming. For better dissolving
of impurities, wait a few seconds (longer in the case of heavily soiled
records) before starting the vacuuming process.
Once the fluid covers the entirety of the record, turn the motor switch to the
“I” position (if not already at that position) and place the vacuum arm above
the record pointing at the spindle until it reaches its lock position.
Turn the Vacuum motor to the “I” position at the same time as you set the arm
down onto the record. After the cleaning fluid has been thoroughly vacuumed,
switch off the vacuum, followed by the motor (we recommend one rotation on
the “I” setting and afterwards another rotation on the “II” setting). Return
the vacuum arm into its rest position and wait a few seconds for the record
to dry thoroughly. Remove the clamp, turn the record over and repeat steps for
the opposite side of the record.
The VC-E2 is equipped with automatic overheating protection, which switches
the motor off in case of excessive usage. After a cool-down period, the VC-E2
will return to its fully operational status.
After use tip: We highly recommend to remove the vacuum arm from its
position on the flange and switch the vacuum motor on for 15-30s in order to
blow away all the remaining liquid from the motor and the whole system. This
will help to keep all internal parts of the unit dry and significantly lower
the possibility to be affected with rust. For the same reason it is also not
recommended to pack the VC-E2 back into its plastic bag from original
packaging.
Maintenance and cleaning
Your record cleaning machine requires little to no regular maintenance.
The internal tank has a substantial capacity and subsequently takes a very
long time to reach full capacity. Common home use of the unit does not require
to empty the tank (the vacuumed liquid evaporates during the vacuuming
process and as it rests in the tank). In rare cases the tank can be emptied:
- Disconnect the mains cable
- Turn the VC-E2 up side down to drain the unit reservoir to a big container.
- Clean the liquid on the body of the unit using a cloth
Regularly check the velvet strips on the arm. Make sure they are clean, no
dirt or debris is present.
Prior to maintenance, always disconnect the record cleaning machine from the
power outlet!
How to replace vacuum arm strips
Remove the old strip from the vacuum arm and clean the residue of the glue. A transparent plastic tool is included with the strips in the accessory box, insert the tool fully into the groove and it will help you to place the new strip into its position on the arm.
Technical specifications Vinyl Cleaner VC-E2
Nominal speed | 30 r.p.m. |
---|---|
Power consumption | 230V/800W, 120V/360W, 100V/250W |
Dimensions (W x D x H) | 310 x 210 x 266 mm (fully assembled) |
Weight | 6,5kg (nettop) |
Fuse | T6,3A |
Potential incorrect use and fault conditions
Pro-Jest products are manufactured to the highest standards and undergo strict
quality controls before leaving the factory. Faults that may possibly occur
are not necessarily due to material or production faults but can sometimes be
caused by incorrect use. Some of these faults are as follows:
The platter doesn’t turn although the unit is switched on:
- The power cord is not connected to the unit
- The power cord is not plugged in to the AC wall outlet
- Broken fuse in the main switch
- Overheating protection is active
Service
Should you encounter a problem which the above information does not able to
alleviate or identify, please contact your dealer for assistance.
Guarantee repairs will only be affected if the unit is returned correctly
packaged. For this reason we recommend keeping the original packaging.
Never return a record cleaning machine without making sure that is it safely
disassembled and correctly packaged in the original packaging.
Warranty
The manufacturer accepts no responsibility for damage caused by not adhering
to these instructions for use and/or by transportation without the original
packaging. Modification or change to any part of the product by unauthorized
persons will void the manufacturer’s warranty. Most Pro-Jest products – unless
expressly advertised otherwise – are intended for domestic use only. Using
them for business applications are done so at your own risk.
Project Audio Systems is a Registered Trademark of H. Lichtenberger.
This guide was produced by: Project Audio Systems
Copyright© 2022. All rights reserved.
The information was correct at the time of printing. The manufacturer reserves
the right to make changes to the technical specification without prior notice
as deemed necessary to uphold the ongoing process of technical development.
Declaration of Conformity
We, declare under our responsibility that the product is in conformity with
the provisions of Directives:
2014/35/EU including amendments
2014/30/EU including amendments
The following harmonised standards were applied:
EN 60335-1:02+A1:04+A11:04+A2:06+A12:06+A13:08+A14:10+A15:11
EN 60335-2-2:10+A11:12+A1:13
EN 55014-1:06+A1:09+A2:11
EN61000-3-2:14
EN61000-3-3:13
EN55014-2:97+A1:01+A2:08
Pro-Jest Audio Systems a division of Audio Tuning GmbH
1050 Vienna, Austria, Demonstrativeness 98
info@project-audio.com
© Pro-Jest Audio Systems
· VC-E2 · Revision 2022.11.07