Thank you for purchasing the PR-W3PI. Your new Power Distribution Unit (PDU) by Big Dog Power provides filtered AC power to your equipment. 3 individually controlled outlets provide up to 2380 Joules of surge protection. Wi-Fi and Wired LAN connections give flexibility with placement and network connectivity. The built-in Self-Healing functions of the PR-W3PI will keep your network-connected equipment going by automatically rebooting and maintaining the equipment. The PR-W3PI is designed to be used in an ITE Computer room or within an equipment rack. It can be surface mounted in many orientations such as to the inside of a rack, the underside of a rack shelf that has slots or drilled holes, or onto the wall of an IT or server room.

Features

  •  3 individually controlled outlets
  • Wall/Surface Mountable
  • Self-Healing functions for network-connected equipment
  •  2380 Joule Surge Protection (L-N Protection)
  • Web and Mobile app for remote management and notification
  •  IP automation integration
  • 120V/12A Rating

Anatomy
A. At a glance status LEDs
a. See LED functions for more information
B. Recessed Reset Button
a. Hold the button for 10 seconds to perform factory restore
C. Configurable Power Button
D. Outlet Status LEDs
a. See LED functions for more information
E. 15-amp Circuit Breaker
F. Wi-Fi Antenna
G. Ethernet Port
H. Individually controlled Outlets
I. IEC Power Input 120v
J. Surface mount ear attachment locations

LED Indicators

“G” or
Ground| On: PDU is grounded properly
Off: PDU is not grounded
---|---
“P” or
Power| Blue: Good / Protected and Clean power
Red: Bad, No Protection
“N” or
Network| Blinking Red: No Network Connection
Solid Blue: Good Network Connection
Rapid Blinking Red: PDU failure requires a reboot or reset
Outlet Status| On: Outlet is On
Off: Outlet is Off

INSTALLATION

Surface Mount
Step 1) Use the included screws to attach surface mount ears to PDU
a) Surface mount ears may be attached at 0°, 90°, 180°, and 270° to accommodate the desired mounting orientation
Step 2) Install appropriate surface mount screws (not included) through the surface mount ears into the desired surface.

CONNECTIONS and USE
Physical Connections
Step 1) Plug in all to be used connections Including:
a) Ethernet LAN
i) Skip the Ethernet cable if you will be using Wi-Fi
b) Connected equipment power cables
Step 2) Insert the female end of the included 6ft power cord into the PR-W3PI Step 3)
Plugin the Male end of the included 6ft power cord into the main outlet on the wall.

Wi-Fi Setup
If using the Wi-Fi connection, follow these instructions

Step 1) Plug in the included power cable to the PDU and to the AC mains outlet on the wall.
a) Wait approximately 15-30 seconds, and the power button will begin to flash.
Step 2) Scan for Wi-Fi on your Wi-Fi enabled device with a web browser
Step 3) Connect to the Wi-Fi SSID of the PDU
a) The SSID of the PDU will be “Metra-XXXX XXXX XXXX” where the “x” is the MAC address or device ID of the PDU.
i) Verify the code of the SSID matches the MAC address of the PDU with the Sticker that is attached to the bottom of the PDU.
Step 4) In a web browser go to “192.168.4.1”
Step 5) Go to “Network”
Step 6) Click “SCAN NETWORKS”
a) The network mode can also be changed before scanning. For ease of setup, we’ll use the default DHCP settings.
Step 7) Select the desired network SSID
NOTE: the PDU requires a 2.4Ghz Wi-Fi connection.
Step 8) If required enter the password for the Wi-Fi connection
Step 9) Click “Save”
a) The PDU will now connect and reboot. After it has rebooted it will attempt to connect to the Wi-Fi signal.
Step 10) Once the PDU has been connected to the network and has access to the web, proceed to the next steps

Cloud setup
Step 1) Log in to your MAVbase.com account
Step 2) Click the Add New button
a) Then click “ADD PDU”
Step 3) Add the PR-W3PI to your account using the MAC address of the PDU

Surge Protection

Protected Circuit(s)
Internal 2380 Total Joule Protection from the Line to Neutral circuit.
IMPORTANT SAFETY INSTRUCTIONS

Read and observe the following safety points at all times.
Notice
For indoor use only. Internal components are not sealed from the environment. The device can only be used in a fixed location such as a telecommunication center, or a dedicated computer room. When you install the device, ensure that the protective earthing connection of the socket-outlet is verified by a skilled person. Suitable for installation in Information Technology
Rooms to power ITE equipment such as Monitors, Computers, Etc.
Only use brackets/attachments/accessories specified by the manufacturer.
Do not place the device in an unstable position where it might fall and cause injuries. This equipment is not suitable for use in locations where children are likely to be present.
Do not cover this device with a cloth. Do not install it on a carpet or rug.

Caution – Potential injury
Do not use this product with extension cords, multioutlet power strips, multioutlet extenders, or UPS devices (other than a Big Dog Power UPS). The power capacity of these accessories can be overloaded by this product and may result in a risk of fire, or property damage.
Warning – Power sources, grounding, polarization
This plug is designed to be inserted into a NEMA 5-15 (three-prong grounded) outlet only. Do not force the plug into an outlet that is not designed to accept it. Never dismantle the plug or alter the power cord, and do not attempt to defeat the grounding feature by using a 3-to-2 prong adapter. If you have questions about grounding, consult your local power company or a qualified electrician.
This PDU requires a properly grounded outlet for safety. If you’re not sure if your home’s electrical wiring is properly grounded, have it checked by a qualified electrician.
If a rooftop device such as a satellite dish connects to the PDU, ensure that the device’s wires are also properly grounded.
Warning – Liquid: avoiding electrical shocks
Do not operate the PDU if liquid of any kind is spilled onto or inside the unit. Do not operate it near rain or water, even water that is contained (for example, bathtub or sink).
Warning – Power cord safety
Do not place the power cord near areas with heavy foot traffic (for example, hallways). Do not create a trip hazard with the power cord.
If the power cord’s protective jacket rips or frays, exposing the internal wiring or shielding, disconnect it from the power source and replace the power cord immediately. See the warranty section of the owner’s manual for details.
Warning – No user-serviceable parts inside
If the PDU is not operating properly, do not remove any part of the unit (cover, etc.) for repair. Unplug the unit and consult the warranty section of the owner’s manual.
Caution – Exposure to heat
Do not expose the PDU to direct sunlight or place it near-wall heaters, space heaters, or in an enclosed space prone to temperature increase.
Do not use the device in a confined, poorly-ventilated location; this can overheat the unit, possibly even causing a fire. If used in a small space other than an EIA-standard rack, ensure that there is adequate space around the device.
Caution – Proper cleaning
In general, the only cleaning necessary is a light dusting. Unplug the PDU from the wall outlet before cleaning it. Do not use liquid or aerosol cleaners.

FCC WARNING

WARNING!! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Notice : (1) An unshielded-type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television reception. It is essential that only the supplied power cord by using. (2) Use only shielded cables to connect I/O devices to this equipment.
Note: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
The Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulation.
Cet appareil numerique de la class B respecte toutes les exigencies du Reglement sur le materiel brouilleur du Canada.

FCC Part15C+RSS247
To assure continued FCC compliance:

  1. Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment.
  2.  This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.

This radio transmitter [27941-PRW3PI] has been approved by Innovation, Science, and Economic Development Canada to operate with the antenna types listed below, with the maximum permissible gain indicated. Antenna types not included in this list that have a gain greater than the maximum gain indicated for any type listed are strictly prohibited from use with this device.

NO.| Antenna
Type| Model
Name| Gain
(Peak)
---|---|---|---
1| Dipole| Q0211| 2 dBi

IC
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.

© Copyright 2022 Ethereal Home Theater, LLC.
The information contained herein is subject to change without notice. This document contains proprietary information protected by copyright law. No part of this document may be photocopied or reproduced without prior written consent.
metrahometheater.com
metraav.com
MAVBase.com
386-255-0234

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals