HORIZON S2200 Spektrum Smart Charger Instruction Manual

June 9, 2024
Horizon

HORIZON S2200 Spektrum Smart Charger

HORIZON-S2200-Spektrum-Smart-Charger-fig-1

Items Needed to Perform Updates on your Spektrum Smart Charger

  • A Windows Operang System PC (Windows 7 and up)
  • Spektrum SPMXCA100 Update Cable OR a USB to Micro USB cable
  • Any Spektrum Smart Charger or the XBC100 Smart Checker

How to Perform Update – Step by Step Guide

  1. See Page 2 – Find the latest update download for your Smart device and click the link to download
    • Click the download icon in top right corner to download the .zip file
  2. Once downloaded, please extract the .ZIP file to a locaon that you can easily find, we suggest the Desktop
  3. Locate the SCU.exe file and open/execute
  4. You will be presented with this screen
  5. Plug in power to your Smart Charger
  6.  Then plug in the XCA100 or USB Update cable into your PC and into the port on side of charger
  7. The lower poron of the screen will then display the Device and firmware version currently on your Smart Charger
    • IF the included driver package fails to install download this alternave version HERE – XCA100 Driver
  8. Click the Update buon to install the update on your Smart Charger. A progress bar will appear on your computer screen and the screen/indicator on your Smart Charger will nofy that an update is in progress.

HORIZON-S2200-Spektrum-Smart-Charger-fig-3

Latest Smart Charger Firmware Downloads

  • Smart AC powered chargers
    • S2200 Spektrum Smart S2200 AC Charger (SPMXC2010) – A: V1.0.0.21 B: V2.0.0.7 – Download
    • S1200 Spektrum Smart S1200 AC Charger (SPMXC2020) – A: V1.0.0.32 B: V2.0.0.11 – Download
    • S1100 Spektrum Smart G2 S1100 AC Charger (SPMXC2080) – A: V1.0.0.34 B: V2.0.0.11 – Download
    • S2100 Spektrum Smart G2 S2100 AC Charger (SPMXC2000) – V1.1.0.20 B: V2.0.0.7 – Download
    • S1400 Spektrum Smart S1400 AC Charger (SPMXC2040) – A: V1.0.0.33 B: V2.0.0.11 – Download
    • S155 Spektrum Smart S155 AC Charger, 1x55W (SPMXC2050) – V1.0.0.16 – Download
    • S2100 Spektrum Smart S2100 AC Dual Port Charger (SPMXC1010) – V1.1.0.17 – Download
    • S1100 Spektrum Smart S1100 AC Charger (SPMXC1080) – V1.0.0.32 – Download
  • Smart DC powered chargers
    • S1200 Spektrum Smart S1200 DC Charger (SPMXC1000) – V3.1.0.13 – Download
    • S1500 Smart S1500 DC Charger (SPMXC1050) – V1.1.0.10 – Download
    • S150 Smart S150 AC/DC Charger (SPMXC1070) – V1.0.0.28 – Download
    • S120 Spektrum Smart S120 USB-C Charger (SPMXC1020) – V1.0.2.4 and V1.0.0.17 – Download
  • Smart Checker
    XBC100 Smart Checker (SPMXBC100) – V1.0.0.21 – Download
    FIND ALL SMART DEVICE UPDATE FILES HERE (including some back logs if you wish to downgrade)

WARNING
IT IS EXTREMELY IMPORTANT THAT YOU CHOOSE THE CORRECT FIRMWARE FOR THE CHARGER YOU ARE UPDATING! INSTALLING THE INCORRECT FIRMWARE WILL CUASE THE CHARGER TO BECOME INOPERABLE! ONE COMMON MISTAKE IS INSTALLING THE S1200 AC FIRMWARE ON THE S1200 DC, WHICH ARE 2 DIFFERENT MODELS.

Smart Charger Firmware Change Logs

Please note – some firmware versions will have 2 available version numbers depending on your model’s hardware specificaons. For those models that have 2 different version numbers, they will be labeled Version A or B (ex. A: V1.0.0.21 B: 2.0.0.7). Funconally, these hardware and firmware variants are the same, but some of the internal components may be different depending on your version. The updater used for your Smart Charger will automacally recognize the hardware version and apply the correct update.

S2100 AC Smart Charger (SPMXC2000)
A: V1.0.0.20 B: V2.0.0.7

  • Fixes bug that disabled charging of standard non-Smart NiMH baeries
  •  Fixes backlight bug caused by volume control
  • Modified lower voltage NiMH charging
  • Baery Firmware Update for Spektrum Smart G1 and G2 baeries
    • This baery firmware update greatly decreases the energy consumpon of the integrated Smart chip.
    • To install baery updates –
    1. Update your Smart Charger
    2. Plug in your Smart baery while charger is powered on
    3. A prompt will appear advising there is an update for your baery
    4. Select Yes to install the update and wait for update to complete

S1100 AC Smart Charger (SPMXC2080)
A: V1.0.0.34 B: V2.0.0.11

  • Fixes bug that disabled charging of standard non-Smart NiMH baeries
  • Fixes backlight bug caused by volume control
  • Modified lower voltage NiMH charging
  • Baery Firmware Update for Spektrum Smart G1 and G2 baeries
    • This baery firmware update greatly decreases the energy consumpon of the integrated Smart chip.
    • To install baery updates –
    1. Update your Smart Charger
    2. Plug in your Smart baery while charger is powered on
    3. A prompt will appear advising there is an update for your baery
    4. Select Yes to install the update and wait for update to complete
S2200 AC Smart Charger (SPMXC2010)

A: V1.0.0.21 B: V2.0.0.7

  •  Fixes bug that disabled charging of standard non-Smart NiMH baeries
  • Fixes backlight bug caused by volume control
  • Modified lower voltage NiMH charging
  • Baery Firmware Update for Spektrum Smart G1 and G2 baeries
    • This baery firmware update greatly decreases the energy consumpon of the integrated Smart chip.
    • To install baery updates –
    1. Update your Smart Charger
    2. Plug in your Smart baery while charger is powered on
    3. A prompt will appear advising there is an update for your baery
    4. Select Yes to install the update and wait for update to complet

V1.0.0.17
Bug Fix – Balance lead disconnecon error now works properly

V1.0.0.16

  • Displays Baery and Charger temps in both F and C
  • Added menu item: Auto Charge On/Off
  • Expanded end voltage range for LiPo and LiHV baery types
    • LiPo = 4.10V to 4.20V | LiHV = 4.18V to 4.35V
S1200 AC Smart Charger (SPMXC2020)

A: V1.0.0.32 B: V2.0.0.11

  • Fixes bug that disabled charging of standard non-Smart NiMH baeries
  • Fixes backlight bug caused by volume control
  •  Modified lower voltage NiMH charging
  • Baery Firmware Update for Spektrum Smart G1 and G2 baeries
    • This baery firmware update greatly decreases the energy consumpon of the integrated Smart chip.
    • To install baery updates –
    1. Update your Smart Charger
    2. Plug in your Smart baery while charger is powered on
    3. A prompt will appear advising there is an update for your baery
    4. Select Yes to install the update and wait for update to complete

V1.0.0.26
Bug Fix – Balance lead disconnecon error now works properly

V1.0.0.24

  • Displays Baery and Charger temps in both F and C
  • Added menu item: Auto Charge On/Off
  • Expanded end voltage range for LiPo and LiHV baery types
    • LiPo = 4.10V to 4.20V | LiHV = 4.18V to 4.35V
S1400 AC Smart Charger (SPMXC2040)

A: V1.0.0.33 B: V2.0.0.11

  • Fixes bug that disabled charging of standard non-Smart NiMH baeries
  • Fixes backlight bug caused by volume control
  • Modified lower voltage NiMH charging
  •  Baery Firmware Update for Spektrum Smart G1 and G2 baeries
    • This baery firmware update greatly decreases the energy consumpon of the integrated Smart chip.
    • To install baery updates –
    1. Update your Smart Charger
    2. Plug in your Smart baery while charger is powered on
    3. A prompt will appear advising there is an update for your baery
    4. Select Yes to install the update and wait for update to complete

V1.0.0.28

  • Bug Fix – Balance lead disconnecon error now works properly
  • Bug Fix – 1S Baery charging now funcons correctly

V1.0.0.26

  • Displays Baery and Charger temps in both F and C
  • Added menu item: Auto Charge On/Off
  • Expanded end voltage range for LiPo and LiHV baery types
    • LiPo = 4.10V to 4.20V | LiHV = 4.18V to 4.35V
S1200 DC Smart Charger (SPMXC1000)

V3.1.0.13

  • Fixes bug that disabled charging of standard non-Smart NiMH baeries
  • Fixes backlight bug caused by volume control
  • Modified lower voltage NiMH charging
  • Baery Firmware Update for Spektrum Smart G1 and G2 baeries
    • This baery firmware update greatly decreases the energy consumpon of the integrated Smart chip.
    • To install baery updates –
    1. Update your Smart Charger
    2. Plug in your Smart baery while charger is powered on
    3. A prompt will appear advising there is an update for your baery
    4. Select Yes to install the update and wait for update to complete

V3.1.0.12

  • Corrected Smart Auto Charging bug
  • Improved low voltage tolerance in NiMH charging mode

V3.1.0.9
Bug Fix – Balance lead disconnecon error now works properly

V3.1.0.8

  • Displays Baery and Charger temps in both F and C
  • Added menu item: Auto Charge On/Off
  • Expanded end voltage range for LiPo and LiHV baery types
    • LiPo = 4.10V to 4.20V | LiHV = 4.18V to 4.35V
  • Added menu opons to adjust Input Power Limit (Waage) and Minimum Input Power (Voltage)
    • Located in System Sengs Menu
  • Fixed Baery C rang bug
  • Fixed Smart NiMH charging bug

V3.1.0.5
G2 Baery Update will push to baery firmware if out of date

V3.1.0.4

  • Updated Generaon 2 (G2) user interface
  • New features included with G2 Interface
    • Automac Start with Smart Baeries
    • Esmated Charge Time Remaining
    • Charge and Balance Smart G2 Baeries
S2100 AC Smart Charger (SPMXC1010)

V1.1.0.17
Bug Fix – Balance lead disconnecon error now works properly

V1.1.0.11

  • Displays Baery and Charger temps in both F and C
  • Added menu item: Auto Charge On/Off
  • Expanded end voltage range for LiPo and LiHV baery types
    • LiPo = 4.10V to 4.20V | LiHV = 4.18V to 4.35V
  • Fixed Baery C rang bug
  • Fixed Smart NiMH charging bug

V1.1.0.7
G2 Baery Update will push to baery firmware if out of date

V1.1.0.3

  • Updated Generaon 2 (G2) user interface
  • New features included with G2 Interface
    • Automac Start with Smart Baeries
    • Esmated Charge Time Remaining
    • Charge and Balance Smart G2 Baeries
S1500 DC Smart Charger (SPMXC1050)

V1.1.0.10

  • Fixes bug that disabled charging of standard non-Smart NiMH baeries
  • Fixes backlight bug caused by volume control
  • Modified lower voltage NiMH charging
  • Baery Firmware Update for Spektrum Smart G1 and G2 baeries
    • This baery firmware update greatly decreases the energy consumpon of the integrated Smart chip.
    • To install baery updates –
    1. Update your Smart Charger
    2. Plug in your Smart baery while charger is powered on
    3. A prompt will appear advising there is an update for your baery
    4. Select Yes to install the update and wait for update to complete

V1.1.0.9

  • Corrected Smart Auto Charging bug
  • Improved low voltage tolerance in NiMH charging mode

V1.1.0.6
Bug Fix – Balance lead disconnecon error now works properly

V1.1.0.5

  • Displays Baery and Charger temps in both F and C
  • Added menu item: Auto Charge On/Off
  • Expanded end voltage range for LiPo and LiHV baery types
    • LiPo = 4.10V to 4.20V | LiHV = 4.18V to 4.35V
  • Added menu opons to adjust Input Power Limit (Waage) and Minimum Input Power (Voltage)
    • Located in System Sengs Menu
  • Fixed Baery C rang bug

V1.1.0.3
G2 Baery Update will push to baery firmware if out of date

V1.1.0.2

  • Updated Generaon 2 (G2) user interface
  • New features included with G2 Interface
    • Automac Start with Smart Baeries
    • Esmated Charge Time Remaining
    • Charge and Balance Smart G2 Baeries
S1100 AC Smart Charger (SPMXC1080)

V1.0.0.32

  • Displays Baery and Charger temps in both F and C
  • Added menu item: Auto Charge On/Off
  • Expanded end voltage range for LiPo and LiHV baery types
    • LiPo = 4.10V to 4.20V | LiHV = 4.18V to 4.35V

V1.1.0.3

  • G2 Baery Update will push to baery firmware if out of date
  • Fixes G2 balance lead required error

V1.0.0.29
Improved G2 UI and Time Remaining Calculaons

S155 AC Smart Charger (SPMXC2050)

V1.1.0.16
Fixes bug that disabled charging of standard non-Smart NiMH baeries

V1.1.0.15

  • Modified lower voltage NiMH charging
  • Baery Firmware Update for Spektrum Smart G1 and G2 baeries
    • This baery firmware update greatly decreases the energy consumpon of the integrated Smart chip.
    • To install baery updates –
    1. Update your Smart Charger
    2. Plug in your Smart baery while charger is powered on
    3. A prompt will appear advising there is an update for your baery
    4. Select Yes to install the update and wait for update to complete

V1.0.0.14
Improved low voltage tolerance in NiMH charging mode

V1.0.0.12
Corrected the screen off bug when “Blacklight” changed to “Low”

S150 AC/DC Smart Charger (SPMXC1070)

V1.0.0.28
NiMh mode only chargers Spektrum Smart NiMh baeries

V1.0.0.26

  • Improved NiMH Charging Calculaons
  • G2 Baery Charging
S120 USB Powered Smart Charger (SPMXC1020)

V1.02.4 or V1.0.0.17 (depending on hardware version)
Improved low voltage tolerance in NiMH charging mode

V1.0.2.2

  • Improved NiMH Charging Calculaons
  • G2 Baery Charging
XBC100 Smart Checker (SPMXBC100)

V1.0.0.19

  • Now displays connected Smart Baeries Firmware Version on main dashboard
  • Baery Firmware Update for Spektrum Smart G1 and G2 baeries
    • This baery firmware update greatly decreases the energy consumpon of the integrated Smart chip.
    • To install baery updates –
    1. Update your Smart Checker
    2. Plug in your Smart baery while charger is powered on
    3. A prompt will appear advising there is an update for your baery
    4. Select Yes to install the update and wait for update to complete

V1.0.0.19
Displays Baery temps in both F and C

V1.0.0.18

  • Fixed voltage miscalculaon
  • G2 Baery Update will push to baery firmware if out of date

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Horizon User Manuals