SPECIFICATIONS

Power supply 2xAAA1 5V battery, Alkaline preferred
Carrying case RC-100 in carrying case
Communication 940 nm Infrared Tx & Rx
Upload range Up to 15 m (50 ft. )
Op. temperature 0°C-50°C (32°F-122°F)
Dimensions 123 x 70 x 20.3 mm (4 . 84″ x 2.76″ x 0. 8″)

WARNING  Remove the batteries from compartment if the remote will not be used in 30 days.

OVERVIEW

The remote control Wireless IR Confiquration Tool is a handheld tool for remote confiquration of IR-enabled fixture integrated sensors. The tool enables device to modify via pushbutton without ladders or tools, and stores up to four sensor parameter modes to speed configuration of multiple sensors.
The remote control send sensor setting at mounting height up to 50 feet. The device can display previously established sensor parameters, copy parameters and send new parameters or store parameter profiles. For projects where identical settings may be desired across a large number of areas or spaces, this capability provides a streamlined method of configuration. Settings can be copied throughout a site, or in different sites.

LED INDICATORS

LED DESCRIPTION LED DESCRIPTION

BRIGHTNESS

|

High end trim turning function(To Set the output level of connected lighting during occupancy)

| | To select the current surrounding lux value as the daylight threshold. This feature enables the fixture to function well in any real application circumstances.

SENSITIVITY

|

To set the occupancy sensing sensitivity of the Sensor

| NICOR H12VSENSOR Sensors Remote Programmer \(2\)| The daylight sensor stops working, and all motion detected could turn on the lighting fixture, no matter how bright the natural light is.

HOLD TIME

|

The time that the Sensor will turn off(if you choose stand-by level is 0) or dim the light to a low level after the area is vacated

|

STAND-BY DIM

| To set the output level of connected lighting during vacancy. The sensor will regulate the lighting output at the set level. Setting the STAND-BY DIM level at O means light full off duringvacancy.
DAYLIGHT SENSOR| To represents various thresholds of natural light level for the Sensor .|

STAND-BY TIME

| To represents the time that the Sensor will keep the light at low dim level after the HOLD TIME elapsed.

Change multiple setting of sensors with smart photocell sensor Open

  1. Press Disp , the remote led indicators will show the latest parameters.
  2. Press UP or DOWN enter in the setting condition, the parameter Led indicators of remote control will flash tobe selected.
  3.  Press NICOR H12VSENSOR Sensors Remote Programmer \(8\),2 led indicators will flash in daylight sensor settings ,select daylight 10 30 50 as setpoint to light on Automatically, select daylight 100 300 500 as setpoint to light off Automatically.
  4. Press OK to confirm all setting and saving.
  5.  Aim at the target sensor and press SEND to upload the new parameter. The led light which the sensor

NOTE:NICOR H12VSENSOR Sensors Remote Programmer
\(8\) is disabled by default.

  1. Open or close the smart daylight sensor by pushNICOR H12VSENSOR Sensors Remote Programmer \(8\) when the remote control is in setting condition.
  2. When the smart daylight sensor open, 2 Led indicators are flash in daylight sensor setting. select daylight 10 30 50 as setpoint to light on Automatically, select daylight 100 300 500 as setpoint to light off automatically.When smart daylight sensor close, 1 Led indicator is flash i the daylight sensor setting for choose daylight sensor threshold.
  3. When the smart daylight sensor open, the stand-by time is only 8
  4. Smart daylight sensor takes place of normal outdoor daylight senor switch, working independently.
  5. See Daylight Sensor Function.

Corridor Function

This function inside the motion sensor to achieve tri-level control, for some areas which require a light change notice before switch-off. The sensor offers 3 levels of light: 100%–>dimmed light (natural light is insufficient)–>off; and 2 periods of selectable waiting time: motion hold-time and stand-by period; Selectable daylight threshold and freedom of detection area.

NICOR H12VSENSOR Sensors Remote Programmer \(3\)

  • With sufficient natural light, the light does not switch on when presence is detected.
  • With insufficient natural light, the sensor switches on the light automatically when presence is detected.
  • After hold-time, the light dims to stand-by level if the surrounding natural light is below the daylight threshold.
  • Light switches off automatically after the stand-by period elapses.

Daylight Sensor Function

Open the daylight sensor by pushNICOR H12VSENSOR Sensors Remote Programmer
\(8\) when remote control is in setting condition.

NICOR H12VSENSOR Sensors Remote Programmer \(4\)

  • The light switches on at 100% when there is movement detected.
  • The light dims to stand-by level after the hold-lime.
  • The light remains in dimming level at night.

Settings on this demonstration:

  • Hold-time: 30min
  • setpoint to light on : 50lux
  • setpoint to light off: 300lux
  • Stand-by Dim: 10%
  • Stand-by period: +oo ( when the smart photocell sensor open, the stand-by time is only +oo )

BUTTON OPERATION

NICOR H12VSENSOR Sensors Remote Programmer \(5\)

SETTING

The SETTING Content contains all available settings and parameters for remote sensors. It allows you to change the available control, parameters, and operation of the sensor from factory default or current parameters.

Change multiple settings of sensor(s)

  1. Press Disp button, the remote control leds will show the latest parameters you set.
    NOTE: if you push ON/OFF button before, you must push Auto button to unlock the sensor.

  2. Press UP or DOWN enter in the setting condition, the parameter leds of remote control will flash to be selected, navigate to the desired setting by pressing UP DOWN LEFT ARROW RIGHT ARROW to select the new parameters.

  3. Press ok to confirm all setting and saving.

  4. Aim at the target sensor and press to upload the new parameter, the led light which the sensor connects will on/off as confirm.
    NOTE: The setting works key step is by UP or DOWN , enter in the setting condition.
    NOTE: The led light which the sensor connects to will flash on/off to confirm receiving the new parameters.
    NOTE: If you press Disp button, the remote led indicators will show the latest parameters which were sent.

NICOR H12VSENSOR Sensors Remote Programmer \(6\)

  • When the natural light level exceeds setpoint  off to light,the light will turn off even if when the space is occupied .
  • The light automatically turns on at 10% when natural light is insuffcient (no motion ).

NICOR H12VSENSOR Sensors Remote Programmer \(7\)

Corridor Function VS Daylight Sensor Function.

  1. ln corridor function, turn on the light MUST by natural light level lower daylight sensor setting and Occupancy. In smart daylight sensor function, turn on the light by natural light level lower daylight setpoint to light on even if vacancy.
  2. In corridor function, turn off light by stand-by time finish if vacancy. In smart daylight sensor function, turn off the light by natural light level higher than daylight setpoint to light off eve if occupancy.
  3. ln smart daylight sensor function, natural light level lighter/lower than daylight setpoint to light off/on MUST keep at least 1 mintue,that will turn off/on the light automatically.

About RESET and MODE(1,2,3,4) The remote control comes with 4 Scene MODES which are not default. You may make desired parameters and save as the new MODE(1,2,3,4) to configure the installed sensors.

RESET: all settings go back to settings of DIP Switch in sensor.

SCENE MODES(1 2 3 4)

Application| Scene Options| Brightness| DetectionArea| Hold Time| Stand-by Time| St nd-byDim Level| Daylight Sensor
---|---|---|---|---|---|---|---
Indoor| Mode1| 100%| 75%| 5min| 30min| 30| NICOR H12VSENSOR Sensors Remote
Programmer \(9\)
Indoor| Mode2| 100%| 75%| 1min| +oo| 3| NICOR H12VSENSOR Sensors Remote
Programmer \(9\)
Indoor| Mode3| 100%| 75%| mn| 30min| 30| 30LU
Outdoor| Mode4| 100%| 75%| 1m| +oo|  | (30LUX/300LUX)

Change the MODES:

  1. press Mode1/Mode2/Mode3/Mode4 button,the remote control Led indicators show existing parameters.
  2. press UP DOWN LEFT ARROW RIGHT ARROW to select the new parameters.
  3. Press OK to confirm all parameters and saving in the mode.

UPLOAD The upload function allows you to configure the sensor with all parameters in one operation. You may select CURRENT SETTING parameters or the MODE for uploading.

Current setting parameters or the MODE are displayed in Remote control . Upload the current parameters to sensor(s),and duplicate the sensor parameters form one to anther

  1. Press Disp button or press Mode1/Mode2/Mode3/Mode4 all parameters are displayed in Remote control.
    Note: check if all parameters are correct , if not, change them.

  2. Aim at the sensor and press Send button , the light that sensor connects will be on/off as confirm. Note: if other sensor need same parameters, just aim at the sensor and press Send button.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

NICOR User Manuals

Related Manuals