Before You Begin
Read These Instructions Completely and Carefully

Upgrade Instructions

Slipfitter Mount

  1. Disconnect power from the luminaire and follow proper lockout/tagout procedures before beginning installation or maintenance.

  2. Remove the existing luminaire. Dispose of the lamp(s) and ballast(s) per local requirements.

  3. Slipfitter mount fits a 2 3/8” OD tenon (A).

  4. Place slipfitter over the tenon and secure the fixture using the set screws (B) on the side of the slipfitter.
    NOTE: Take note NOT to pinch any wires when closing the wiring enclosure.

  5. To adjust the aim of the fixture, remove the round cover plate. (C)

  6. Loosen the locking bolt, aim the fixture as desired and then tighten the locking bolt. Secure the round cover plate. (C)

  7. Connect the fixture input leads (D) to the supply wire leads.
    (D) Wiring Diagram

  8. Each fixture is supplied with a twist lock shorting cap. For the fixture to function, the shorting cap MUST be installed.
    Note: An accessory twist lock photocell may also be installed in place of the shorting cap.

  9. Power can now be restored to the fixture.