Overview

Package Contents

  • Device×1 Power Adapter×1 USB Cable×1 Battery×1
  • Wearable strap×2 Quick start guide×1

Battery Instruction

1、 Battery replacement

  1. a) Remove battery: press the battery release latches on both sides simultaneously: and pull the battery out (as shown)

Ring Scanner Instruction a) Ring scanner detachment:press the red button until you

b) Scanner installation:press the red button until the 2 plugs insert into the respective slots and scanner POGOPIN aligns with device POGO-PIN, free switch for different habits.

3、Charging
a) Type-C USB data cable charging.
b) The battery can be charged separately with battery charger.
4、Indicator LED

Power On Green Light up for 3s
Power Off Red Light up for 3s
Low Battery Red Blinking
Charging Red Light up
Full Battery Green Light up
Paired Scanning Green Light up for 1s
Scanning Timeout Red Light up for 1s
Successfully Paired Blue Light up for 3s
Pairing Failed Red/Green blinking for 3M
Disconnected Red/Green blinking for 3M
NFC Identification Light up for 1s

Precautions

N FCn can release the scanner(as shown )

  1. The battery can be charged separately with battery 4、Indicator LED

  2. Read all information in this guide before using the device to ensure safe and proper

  3. Please use the accessories that have been approved by MEFERI and corresponds to this Use of any power source, charger, battery, etc. that has not been approved by MEFERI may cause a fire, explosion, or other hazards.

  4. Please use device and accessories within the specified temperature Equipment failure may occur when the ambient temperature is too high or too low.

  5. Do not disassemble the product and its If the

  6. b) Battery Installation:Install the battery in the direction as

  7. b) Scanner installation:press the red button until the 2 plugs insert into the respective slots and scanner POGOPIN alignsequipment or any of its components are not working properly, please contact and consult our after-sales service center,or send

  8. If the battery shows signs of peculiar smell, overheat, color change, distortion or leakage remove the battery from the charger or the device immediately and stop using

The battery is made from a flammable and explosive material. Do not disassemble, squeeze, drop and make any other destructive operations on the battery. Do not place the battery in high temperature

Warranty Policy

Warranty Terms:

  1. Under normal circumstances, the warranty period of the device is 12 months (3 months for accessories), subject to the sales
  2. During the product warranty period, under the normal use conditions (determined by our technical staff), the user will be entitled to a free warranty for damaged or faulty warranty parts.
  3. During the warranty period, faults caused by repair, disassembly or modification of the product by a personnel other than our company, improper installation, improper use by the user (failure to follow instructions),serial number damage, accident or natural disaster, will not be covered under the
  4. The warranty will expire immediately if any alterations are made to the warranty
  5. Please show the equipment SN and purchase certificate for The company reserves the right to interpret the above contents.

NB

This product complies with the radio interference requirements of the European Community.
Product name: Wearable Ring Scanner
Product model: MS300R
Manufacturer: Meferi Technologies Co.,Ltd. Frequency Range: 2.4GHZ-2.48GHZ,
Max. Transmit Power: 4.44 dBm Max SIMPLIFIED EU DECLARATION OF CONFORMITY
The simplified EU declaration of conformity referred to in Article 10(9) shall be provided as follows:
Hereby, Targus International LLC declares that radio equipment type H566A3T is in compliance with Directive 2014/53/EU, and this product is allowed to be used in all EU member states.
The full text of the EU declaration of conformity is available at following company website:www.meferi.co

This product can be used across EU member states.
EUT Operating temperature: -10~40℃

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  • This device may not cause harmful interference, and
  • This device must accept any interference received, including interference that may cause undesired Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help
RF warning statement:

The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals