COOPER Notification Strobe 355 Candela, Hazardous Location XB12 Owner’s Manual

June 9, 2024
COOPER Notification


Strobe – 355 candela, Hazardous Location XB12

Description:

These high output certified strobes have been designed for use in potentially explosive atmospheres and harsh environmental conditions. The enclosures are suitable for use offshore or onshore, where light weight combined with corrosion resistance is required.

The strobe housing is manufactured completely from a U.V. stable, glass reinforced polyester. Stainless steel screws and mounting bracket are incorporated ensuring a totally corrosion free product.

Units can be painted to customer specification and supplied with identification labels.

Features*:
  • UL Listed for USA and Canada
    -­ Hazardous locations:
    Class I, Div 2, Groups C & D.
    Class I, Zones 1 & 2, AExd IIB T4 & T5.
    -­ Ordinary locations: Visual-Signal Device
  • California State Fire Marshal (CSFM) Listed
  • ATEX approved
  • High Output 355 candela with clear lens
  • NEMA 4x & 6, IP66 and IP67
  • Certified temperature ­-67°F to +158°F (­-55°C to +70°C)
  • Corrosion resistant GRP
  • Optional stainless steel backstrap
  • Various lens colors
  • Optional lens guard
  • 4 wire monitored connection
  • 24 VDC, 110 & 240 VAC
  • Xenon
  • Twin replaceable tubes
Architects and Engineers Specifications

Strobes for hazardous locations and harsh environments shall be UL and cUL listed for Class I, Division 2, Groups C&D, and Class I, Zones 1&2, AExd IIB T4/T5 applications and shall be listed under UL Standard 1638 for Indoor/ Outdoor use. They shall be constructed of lightweight, UV stable glass reinforced polyester, shall be corrosion resistant, and shall meet NEMA 4x, NEMA 6, IP 66 & IP 67 environmental requirements over a temperature range of -67°F to +158°F (-55°C to +70°C).

The strobes shall be rated to flash at 1 Hz with 355 candela per flash. Rated current draw shall not exceed 1400 mA at 24 vdc. The strobe shall be capable of direct surface mounting in any direction.

Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock standard terms and conditions.

| DC| AC50/60 Hz
---|---|---
Voltage| 24| 110| 240
XB12 Tube Energy (Joules)| 21| 21| 21
Peak Current Consumption (mA)| 1400| 350| 185
Effective Intensity (Cd)| 355| 355| 355
NOTE: The Cd figures are for a clear lens @ 1Hz flash rate.

For Colored Lenses

Color Red Blue Amber Green Yellow
Multiplying Factor 0.15 0.12 0.51 0.49 0.86

The photometric data has been verified by BSI. A report is available if required.

Specification

Certification:| UL Listed for USA and Canada:
– Hazardous locations:
 Class I, Div 2 Groups C & D.
 Class I, Zones 1 & 2 AExd IIB T4/T5.
UL Listing No: E187894.
– Ordinary locations: Visual-Signal Device.
California State Fire Marshal (CSFM) Listed
UL listing No. S8128.
ATEX approved: EExd IIB T4/T5
Cert. No. 99 ATEX 2196
---|---
Material: | Body: – Glass reinforced polyester (GRP).
Lens: – Toughened Glass.
Cover Screws + Backstrap: – Stainless steel 316
Finish:| Natural black or painted to customer specification.
Weight:| 15.5 lb./7.0Kg.
Certified Temperature:| –67°F to +158°F (–55°C to +70°C) hazardous locations
–67°F to +131°F (–55°C to +55°C) ordinary locations
Ingress Protection:| NEMA 4x & 6, IP66 & IP67.
Terminals:| 6 x 10 AWG
Labels: | Duty/Tag Label optional.
Entries:| 2 x 1/2″ NPT

Configuration Options:

The following code is designed to help in the selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box.

COOPER Notification Strobe 355 Candela Hazardous Location XB12
2

A

Certification
UL
UL (ordinary locations)| Code
UL
UW
B
Voltage
24V d.c.
110V a.c.
240V a.c.| Code
024
110
240
C
Flash Rate
60/min
Other flash rates available, please specify.| Code
06
D
Color
Red
Blue
Green
Amber
Yellow
Clear| Code
R
B
G
A
Y
C
E
Guard
None
Yes| Code
N
Y
F
Unit Fixing
Direct Mounting
Backstrap| Code
D
B
G
Continuity
None| Code
N
H
Label
None
Yes
(Please specify) | N
Y

I
Options
Blanking Plug
None| Code
P
N
J
Finish
Natural Black
Red
Blue
Yellow
Grey
White
Special Finish| Code
N
R
B
Y
G
W
S

Standard Models

Series Model Number Order Code Description
XB12 XB12UL02406RNBNNNR 109204-001 Strobe, Red Lens, 355 candela, 24 VDC,

Red finish
XB12| XB12UL02406CNBNNNR| 109204-002| Strobe, Clear Lens, 355 candela, 24 VDC, Red finish
XB12| XB12UL02406RNBNNNN| 109204-003| Strobe, Red Lens, 355 candela, 24 VDC, Black finish
XB12| XB12UL11006ANBNNNR| 109204-005| Strobe, Amber Lens, 355 candela, 110VAC, Red finish
XB12| XB12UL11006RNBNNNR| 109204-006| Strobe, Red Lens, 355 candela, 110VAC, Red finish

WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY
XB12 07/07

NJ Location
273 Branchport Ave.
Long Branch, NJ 07740
P: 800-631-2148
F: 732-222-8707
www.coopernotification.com

FL Location
7565 Commerce Ct.
Sarasota, FL 34243
P: 941-487-2300
F: 941-487-2389

VA Location
P: 877-459-7726
F: 703-294-6560

Cooper Notification is Wheelock®

firealarmresources.com

Documents / Resources

| COOPER Notification Strobe 355 Candela, Hazardous Location XB12 [pdf] Owner's Manual
Strobe 355 Candela Hazardous Location XB12, Strobe 355 Candela, Hazardous Location XB12, XB12
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals