These are the original product instructions. This document is part of the product; retain it for the life of the product, passing it on to subsequent holders. Read this manual in full before attempting to assemble, operate, or maintain this product. Always use the latest version of the product manual. The latest version can be downloaded from drapertools.com/manuals

Stock No.| Part No.| Supply voltage| Wattage (W) per bulb| Lumens (lm) per bulb| Beam angle (°)| Colour temperature (K)
---|---|---|---|---|---|---
03195| 110V/TSL/10WT| 110V at 50Hz| 10| 1,100| 100| 6,000~6,500
03201| 110V/TSL/20WT| 110V at 50Hz| 20| 2,200| 100| 6,000~6,500
03203| 110V/TSL/30WT| 110V at 50Hz| 30| 3,300| 100| 6,000~6,500
03205| 110V/TSL/50WT| 110V at 50Hz| 50| 5,500| 100| 6,000~6,500
03211| 230V/TSL/10WT| 230V at 50Hz| 10| 1,100| 100| 6,000~6,500
03212| 230V/TSL/20WT| 230V at 50Hz| 20| 2,200| 100| 6,000~6,500
03213| 230V/TSL/30WT| 230V at 50Hz| 30| 3,300| 100| 6,000~6,500
03215| 230V/TSL/50WT| 230V at 50Hz| 50| 5,500| 100| 6,000~6,500
EU 04355| 230V/TSL20WTFOB| 230V at 50Hz| 20| 2,200| 100| 6,000~6,500
EU 04356| 230V/TSL50WTFOB| 230V at 50Hz| 50| 5,500| 100| 6,000~6,500

This light is rated IP65. It is fully protected against dust and is protected against low pressure jets of water from all directions (limited ingress permitted). This does not include the attached plug.

Health and Safety Information

Important: Read all Health and Safety instructions before attempting to operate, maintain or repair this product. Non-compliance with these instructions may result in injury or damage to the user or the product. Draper Tools accepts no responsibility for improper use of this device.

  • Inspect the product and electrical connections for signs of damage before every use.
    WARNING! Do not use the product if defects are present and withdraw it from service until it has been repaired. If the external power cable is damaged, it must be replaced by suitably qualified personnel or returned to Draper Tools for repair.If required, use an extension lead appropriate for both the product and the environment in which it is used.
    −−Ensure the extension lead is fully unwound regardless of the distance from the power supply to the light.
    −−Use a Residual Current Device (RCD) in damp environments.

  • Always ensure that the voltage rating on the product is appropriate for
    the power supply to be used and that the plug is fitted with the correct fuse.

  • Remove all packaging and wrapping before use.

  • Position the product appropriately.
    −−Use only on level surfaces.
    −−Ensure that the product is stable and unlikely to tip over.
    −−Apply weights to the tripod legs where necessary.
    −−To prevent tripping, clearly mark or place barriers around the base of the product where possible.
    −−This is a Class I appliance and requires an earth connection to protect against electric shock from accessible conductive parts in the event of failure of the basic insulation.

  • Ensure that all joints and attachments are securely fastened when the product is in use or stored.

  • Keep trailing cables and extension leads tidy and secured to avoid trip hazards

Risk of electric shock

Class I product, must be earthed

Replace any cracked protective shield

  • DO NOT carry the light by the cable or plug.

  • WARNING! This product gets hot when in use.
    −−NEVER place objects on the lamp area or hang objects on any part of this product.
    −−NEVER use the light near flammable or combustible substances or equipment.
    −−ALWAYS disconnect the power supply and allow at least ten minutes for the product to cool before attempting any maintenance or adjustment.

  • ALWAYS switch off the light before disconnecting the mains power.
    WARNING! Do not stare at the operating light source.

  • DO NOT pull on the cable to disconnect the light from mains power.

  • This product is certified for use in ambient temperatures of -20 to +45°C.

  • Replace any cracked protective shield.
    −−This product includes a 4mm glass shield rated IK08.

Maintenance and Troubleshooting

Important: Maintenance and repair, including replacement of the light source, must only be performed by qualified personnel with sufficient knowledge of the electrical circuits used in this device.

  • Always disconnect the power supply and allow the lamp to cool before cleaning.
  • Clean the lamp using a dry cloth ONLY.

CAUTION! Do not immerse this product in water.

  • Store the product in a clean and dry environment, out of reach of children, with all joints firmly secured.
    −−Use a Residual Current Device (RCD) in damp environments.
    If the light does not illuminate when switched on, check that all power connections are secured and active.

What’s in The Box?

Carefully remove the product from the packaging and examine it for any signs of damage that may have occurred during shipment

(A) Telescopic tripod
(B) Dual LED SMD site light attachment

  1. Mains power cable
  2. On/off button

Operation Instructions

Before use, check that all parts are present and not damaged

Depending on the Stock Number, the product shipped may differ slightly from the product illustrated in this document

Disposal

Do not dispose of electrical products with household waste. At the end of its working life, or when it can no longer be repaired, dispose of the site light according to local regulations.