Mircom’s BPS-1002 is an extremely cost effective 10 amp voltage regulated remote power supply/battery charger. It may be connected to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notifi cation Appliance Circuit (NAC such as strobes and horns) expansion support to meet ADA requirements. It also provides auxiliary power to support system accessories. The unit delivers regulated and fi ltered 24 volt power to Class B or Class A NAC loop circuits. Additionally, a separate 1.0A auxiliary output with reset for four (4)-wire smoke detectors is available. The 10 amp max. alarm current can be divided between the four (4) outputs for powering NAC devices. Each output is rated at 2.5 amp max., and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). An individual output of 4 amp is achieved by paralleling 2 outputs. The BPS-1002 in non-alarm condition provides independent loop supervision for Class A and/or Class B FACP NAC circuits. In the event of a loop trouble, the FACP will be notifi ed via the steered input (input 1 or input 2). In addition, there are common trouble output terminals (N.C., C, N.O.) which are used to indicate general loop/system trouble. A common trouble input is provided for optional NC (normally closed) devices to report trouble to the FACP. Two (2) FACP signaling outputs can be employed and directed to control supervision and power delivery to any combination of the four (4) outputs. The unit also features “Loop Output” trouble memory indication to help identify trouble some sporatic problems.
Features
- Power input 115VAC 60 Hz, 4.4 amp.
- Two (2) Class A or two (2) Class B FACP inputs
- Field selectable 24VDC or 12VDC voltage regulated power limited outputs
- Two (2) NC dry contact trigger inputs
- 24VDC @10 amp max total alarm current
- 2.5 amp max current per output
- Separate 1 Amp auxiliary output with built-in and remote reset capability
- Two (2) outputs may be paralleled for more power on an indicating circuit
- Programmable supervised indicating circuit outputs: Up to Four (4) Class B or Two (2) Class A or One (1)
- Class A and Two (2) Class BThermal and short circuit protection with auto reset
- Built-in charger for sealed lead acid or gel type batteries
- Automatic switchover to stand-by battery when AC Fails
- Zero voltage drop when switching over to battery backup
- PTC battery protection
- AC fail supervision (form “C” contact, 1 amp / 28VDC). Factory set for 1 minute with optional 18 hour delay setting (fi eld selectable)
- Battery presence and low battery supervision (form “C” contact, 1 amp / 28VDC)
- Input and output status LED indicators
- 2 wire horn/strobe Sync mode allows audible notifi cation appliances (horns) to be silenced while visual notifi cation appliances (strobes) continue to operate
- Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notifi cation appliances circuit)
- Horn/Strobe sync protocols include Mircom, Amseco, Gentex, System Sensor, Faraday and Wheelock
- March Time
- Compatible with 12 or 24VDC fi re panels.
- Filtered and electronically regulated output
- Output loop supervision steered to input 1 or input 2
- Common trouble input and output
- Ground fault detection
- Unit includes power supply, red enclosure, cam lock, open frame transformer and battery leads
Power Supply Specifications
AC Input | 115VAC / 4.4 amp @ 60Hz |
---|---|
Output | 24VDC. Maximum 2.5 amp per output Total of 10 amp in Alarm |
Condition
Battery| For 12VDC operation use a 12VDC / 12AH battery
For 24VDC operation use two (2) 12VDC / 12AH or two (2) 12VDC / 7AH batteries connected in series
Stand-by/Alarm Current:| 90mA/175mA
EOL Resistor (end of line)| 2.2K (2200 ohm)
Standby Specifi cations
Standby Batteries| Standby Time| Alarm Output Total
Amp/Minutes| Aux Output Current
---|---|---|---
24VDC/12AH
(use two (2) 12VDC batteries in series)
| 24 Hours| 10 amp/15 Minutes| 50mA
60 Hours| 10 amp/5 Minutes| –
24VDC/7AH| 24 Hours| 10 amp/5 Minutes| –
24VDC/36AH Battery| 24 Hours| 10 amp/15 Minutes| 1 amp
12VDC/36AH Battery| 24 Hours| 10 amp/15 Minutes| 1 amp
Enclosure Dimensions
Ordering Information
Model | Description |
---|---|
BPS-1002 | 10 Amp Remote Power Supply |
NOT TO BE USED FOR INSTALLATION PURPOSES.
Canada
25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone:
905-660-4655 Fax:
905-660-4113
Web page: http://www.mircom.com
U.S.A.
4575 Witmer Industrial Estates Niagara Falls, NY 14305
Toll Free: 888-660-4655 Fax Toll Free:
888-660-4113
Email: mail@mircom.com
Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifi cations and models and also to discontinue models.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>