Mircom FX-2000 Series Analog Fire Alarm Control Panel Owner’s Manual

June 9, 2024
Mircom

Mircom FX-2000 Series Analog Fire Alarm Control Panel

Introduction

The FX-2000 Analog Fire Alarm Control Panel supports Programmable modules which can be connected either internally to the fire alarm panel or externally via the RAX-LCD Remote Shared Display. Connection to the RAX-LCD allows for unique configurations for a specific remote location.

RAX-LCD Remote Shared Display

The RAX-LCD Remote Shared Display is a remote annunciator that provides the same functions as the main display on the fire alarm control panel, less 16 zone LEDs. It is equipped with a large 4 line x 20 character back-lit alphanumeric LCD display which uses a simple menu system complete with a directional keypad and switches for Enter, Menu, Cancel and Info. It also has 4 Alarm Queue switches and LEDs as well as common control switches and LEDs for Signal Silence, Fire Drill, System Reset, Lamp Test, General Alarm and Acknowledge. The RAX-LCD can be programmed to show different points than the main panel. In addition to being a remote annunciator, the RAX-LCD can also be used as a driver module for standard LED annunciation or reduced zone annunciation (different from the main panel annunciation), graphic drivers programmed different from the main annunciators, programmable switch modules with their unique configuration and fan damper control also with their unique configuration. Each time a different type of annunciation configuration is required or a different location is required an additional RAX-LCD will be needed. The RAX-LCD allows for the control switches to be disabled on a per function basis (via laptop configurator) for areas that do not require certain Common Control functions to be remotely located from the Fire Alarm Control Panel. The RAX-LCD occupies one display position in the BB-1000 or BB-5000 enclosures.

RAX-1048TZDS Programmable Zone LED Annunciator Module

The RAX-1048TZDS Programmable Zone LED Annunciator Module provides 48 programmable bi-coloured LEDs. The RAX-1048TZDS is used if additional LED zone annunciation is required. The addressable points can be grouped together to light one LED, or they can be part of many groups and therefore may turn on many LEDs. The circuits can be selected as either Alarm to illuminate the red LED or for Supervisory to illuminate the amber LED. Any zone trouble condition will be displayed on the Shared Display. The RAX-1048TZDS can be connected to the main panel or it can be connected to the RAX-LCD Remote Shared Display if a programmable remote LED annunciator is required. It takes up two frames when connected to either the main or remote shared display. The RAX-1048TZDS is used in conjunction with the RAX-LCD when a different type of annunciation configuration or a different location is required. The RAX-1048TZDS occupies one display position in the BB-1000 or BB-5000 enclosures.

FDX-008W/KI Fan Damper Control Module

FDX-008W/KI Fan Damper Module provide configurable output circuits for fan or damper control. The FDX-008W has 8 switches, when FDX-008WKI provides 7 switches and a terminal block used to connect a key switch. Each circuit has a slide-in label, a three position selector switch, green “ON” (or open) LED, amber ‘OFF’ (or closed) LED, white ‘AUTO’ (or Normal) LED and a yellow ‘TROUBLE’ LED. The three-position selector switch has a center ‘AUTO’ position, a left ‘OFF’ (or closed) position and a right ‘ON’ (or open) position. In the ‘AUTO’ position the fan or damper follows the fire alarm programming when an alarm occurs. When the switch is turned to the ‘OFF’ position the fan or damper is turned off or closed. If the fan or damper is normally on or open, it will turn off or close when the switch is moved to the ‘OFF’ position. When the switch is moved to the ‘ON’ position the fan or damper is turned on or open. If the fan or damper is normally off or closed, it will turn on or open when the switch is moved to the ‘ON’ position. The ‘ON’, ‘OFF’ and the ‘AUTO’ positions are configurable to remote addressable output modules (MIX-M500CH) and can be configured for normally ‘on or off’ fans or normally ‘open or closed’ dampers. The LEDs can be controlled from the program or by proving switches through mini input modules (MIX-M501M). The FDX-008W/KI can be connected to the main panel or it can be connected to the RAX-LCD Remote Shared Display when a different type of fan/damper configuration or a different location is required. The FDX-008W/KI takes up one frame when connected to the main or remote shared display and occupies one display position in the BB-1000 or BB-5000 enclosures.

IPS-2424DS Programmable Input Switches Module

The IPS-2424DS Programmable Input Switches Module, which provides 24 programmable switches complete with bi-coloured LEDs and slide-in labels, can be configured for ancillary functions such as zone by-pass or added common control functions. In a zone by-pass configuration, a group of addressable devices or hardwired circuits can be assigned to a programmable switch and when the switch is operated, those devices or zones are by-passed. The switches operate in a toggle operation for on and off. There are two LEDs for each switch; one for selection, the other is bi-coloured to indicate point status when the switch is returned to normal (unbypassed) position. The bi- coloured LED will flash red to indicate an alarm or it will flash amber to indicate that a supervisory alarm will be processed when the switch is returned to normal (unbypassed) position. The IPS-2424DS can be connected to the main panel or it can be connected to the RAX-LCD Remote Shared Display if unique programmable input switches are required for a specific location. The IPS-2424DS takes up two frames when connected to the main or remote shared display. The IPS-2424DS occupies one display position in the BB-1000 or BB-5000 enclosures.

Ordering Information

Model Description Standby Alarm
RAX-LCD Remote Shared Display 100 mA 150 mA
RAX-1048TZDS Programmable Zone LED Annunciator Module 5 mA 100 mA
IPS-2424DS Programmable Input Switches Module 10 mA 144 mA
FDX-008W 8-Switch Fan Damper Control Module 15 mA 35 mA
FDX-008WKI 7-Switch Fan Damper Control Module with keys itch 15 mA 35 mA

Customer Support

Canada
25 Interchange Way
Vaughan, Ontario L4K 5W3
Telephone: 905-660-4655
Fax: 905-660-4113
Web page: http://www.mircom.com

U.S.A.
4575 Witmer Industrial Estates
Niagara Falls, NY 14305
Toll Free: 888-660-4655
Fax Toll Free: 888-660-4113
Email: mail@mircom.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Mircom User Manuals

Related Manuals