Introduction
The FX-2000 Analog Fire Alarm Control Panel supports Programmable modules which can be connected either internally to the fire alarm panel or externally via the RAX-LCD Remote Shared Display. Connection to the RAX-LCD allows for unique configurations for a specific remote location.
RAX-LCD Remote Shared Display
The RAX-LCD Remote Shared Display is a remote annunciator that provides the same functions as the main display on the fire alarm control panel, less 16 zone LEDs. It is equipped with a large 4 line x 20 character back-lit alphanumeric LCD display which uses a simple menu system complete with a directional keypad and switches for Enter, Menu, Cancel and Info. It also has 4 Alarm Queue switches and LEDs as well as common control switches and LEDs for Signal Silence, Fire Drill, System Reset, Lamp Test, General Alarm and Acknowledge. The RAX-LCD can be programmed to show different points than the main panel. In addition to being a remote annunciator, the RAX-LCD can also be used as a driver module for standard LED annunciation or reduced zone annunciation (different from the main panel annunciation), graphic drivers programmed different from the main annunciators, programmable switch modules with their unique configuration and fan damper control also with their unique configuration. Each time a different type of annunciation configuration is required or a different location is required an additional RAX-LCD will be needed. The RAX-LCD allows for the control switches to be disabled on a per function basis (via laptop configurator) for areas that do not require certain Common Control functions to be remotely located from the Fire Alarm Control Panel. The RAX-LCD occupies one display position in the BB-1000 or BB-5000 enclosures.
RAX-1048TZDS Programmable Zone LED Annunciator Module
The RAX-1048TZDS Programmable Zone LED Annunciator Module provides 48
programmable bi-coloured LEDs. The RAX-1048TZDS is used if additional LED zone
annunciation is required. The addressable points can be grouped together to
light one LED, or they can be part of many groups and therefore may turn on
many LEDs. The circuits can be selected as either Alarm to illuminate the red
LED or for Supervisory to illuminate the amber LED. Any zone trouble condition
will be displayed on the Shared Display. The RAX-1048TZDS can be connected to
the main panel or it can be connected to the RAX-LCD Remote Shared Display if
a programmable remote LED annunciator is required. It takes up two frames when
connected to either the main or remote shared display. The RAX-1048TZDS is
used in conjunction with the RAX-LCD when a different type of annunciation
configuration or a different location is required. The RAX-1048TZDS occupies
one display position in the BB-1000 or BB-5000 enclosures.
FDX-008W/KI Fan Damper Control Module
FDX-008W/KI Fan Damper Module provide configurable output circuits for fan or
damper control. The FDX-008W has 8 switches, when FDX-008WKI provides 7
switches and a terminal block used to connect a key switch. Each circuit has a
slide-in label, a three position selector switch, green “ON” (or open) LED,
amber ‘OFF’ (or closed) LED, white ‘AUTO’ (or Normal) LED and a yellow
‘TROUBLE’ LED. The three-position selector switch has a center ‘AUTO’
position, a left ‘OFF’ (or closed) position and a right ‘ON’ (or open)
position. In the ‘AUTO’ position the fan or damper follows the fire alarm
programming when an alarm occurs. When the switch is turned to the ‘OFF’
position the fan or damper is turned off or closed. If the fan or damper is
normally on or open, it will turn off or close when the switch is moved to the
‘OFF’ position. When the switch is moved to the ‘ON’ position the fan or
damper is turned on or open. If the fan or damper is normally off or closed,
it will turn on or open when the switch is moved to the ‘ON’ position. The
‘ON’, ‘OFF’ and the ‘AUTO’ positions are configurable to remote addressable
output modules (MIX-M500CH) and can be configured for normally ‘on or off’
fans or normally ‘open or closed’ dampers. The LEDs can be controlled from the
program or by proving switches through mini input modules (MIX-M501M). The
FDX-008W/KI can be connected to the main panel or it can be connected to the
RAX-LCD Remote Shared Display when a different type of fan/damper
configuration or a different location is required. The FDX-008W/KI takes up
one frame when connected to the main or remote shared display and occupies one
display position in the BB-1000 or BB-5000 enclosures.
IPS-2424DS Programmable Input Switches Module
The IPS-2424DS Programmable Input Switches Module, which provides 24
programmable switches complete with bi-coloured LEDs and slide-in labels, can
be configured for ancillary functions such as zone by-pass or added common
control functions. In a zone by-pass configuration, a group of addressable
devices or hardwired circuits can be assigned to a programmable switch and
when the switch is operated, those devices or zones are by-passed. The
switches operate in a toggle operation for on and off. There are two LEDs for
each switch; one for selection, the other is bi-coloured to indicate point
status when the switch is returned to normal (unbypassed) position. The bi-
coloured LED will flash red to indicate an alarm or it will flash amber to
indicate that a supervisory alarm will be processed when the switch is
returned to normal (unbypassed) position. The IPS-2424DS can be connected to
the main panel or it can be connected to the RAX-LCD Remote Shared Display if
unique programmable input switches are required for a specific location. The
IPS-2424DS takes up two frames when connected to the main or remote shared
display. The IPS-2424DS occupies one display position in the BB-1000 or
BB-5000 enclosures.
Ordering Information
Model | Description | Standby | Alarm |
---|---|---|---|
RAX-LCD | Remote Shared Display | 100 mA | 150 mA |
RAX-1048TZDS | Programmable Zone LED Annunciator Module | 5 mA | 100 mA |
IPS-2424DS | Programmable Input Switches Module | 10 mA | 144 mA |
FDX-008W | 8-Switch Fan Damper Control Module | 15 mA | 35 mA |
FDX-008WKI | 7-Switch Fan Damper Control Module with keys itch | 15 mA | 35 mA |
Customer Support
Canada
25 Interchange Way
Vaughan, Ontario L4K 5W3
Telephone: 905-660-4655
Fax: 905-660-4113
Web page: http://www.mircom.com
U.S.A.
4575 Witmer Industrial Estates
Niagara Falls, NY 14305
Toll Free: 888-660-4655
Fax Toll Free: 888-660-4113